Contents

1. individually Device DIP Relay switch LEDs 1 8 AxLink LED NS 2d AxLink Relay contacts 5 8 Relay contacts 1 4 connector discrete commons shared commons Ji gt poe ae fo fe TIN Ge Gp L axtink S sid FIG 2 AXB REL8 front and rear views Installation Guide AXB REL8 Relay Controller Installation Setting the DEVICE DIP Switch Note Use the DIPSwitch 2 0 application available for free download from AMX to quickly figure out DIP Switch settings for all types of DIP Switches Set the device number on DEVICE DIP switch located on the front of the AXB REL8 The device can be 1 of the 255 devices in an Axcess control system The device number must match the device assignment in the Axcess program Device numbers are assigned into the following three segments e Cards 1 through 95 e Boxes 96 through 127 e Panels 128 through 255 Set the device number by setting the device DIP switches The device number is the total of all of the switches in the ON position and take effect by cycling the power DEVICE DIP Switch Settings pomos E 2 P ET ee vawe j je e je je e e a Wiring Preparing and Connecting Captive Wire
2. Connect the control system s AxLink connector to the AxLink connector on the rear panel of the AXB REL8 as shown in FIG 4 PWR Local 12 VDC power supply coming from the PSN power supply GND PW PWR AXP TX AXP TX AXM RX AXM RX GND GND AXB REL8 Central Controller FIG 4 Wiring AxLink with Optional 12 VDC power supply Use a 12 VDC power supply when the distance between the control system and AXB REL8 exceeds the limits described in the Wiring Guidelines at 170 mA table or the power supply current capacity cannot accommodate the 170 ma max draw of the AXB REL8 e Make sure to connect the GND and 12 VDC wire on the AXB REL8 AxLink connector end e Do not connect the optional 12 VDC power supply wire to the control system s power supply side of the AxLink connector FIG 4 Checking The Installation After set up is complete 1 Check continuity of relay wiring 2 Check cable numbers and wiring interfaces and sources against supplied documentation 3 Install tab strips to jumper between shared commons and clip off excess tabs 4 Insert relay wiring terminals into AXB REL8 Relay connections The relay specification is 1 A VAC or VDC FIG 5 shows the relay wiring diagram for the AXB REL8 The dotted lines are used to indicate commons Install supplied tab strips to jumper between shared commons Clip off excess tabs and b
3. AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 e 800 222 0193 fax 469 624 7153 technical support 800 932 6993 e www amx com System Worksheet AXB REL8 Dealer ID Dealer PO Job SO Description Serial g 7 5 s 4 3 2 1 D x rN LN LN EN EN ION ONTO a2 amp BABABABABABABABA feleT l f t s1 1 1 5 Nc Device Wiring Function Color Pin AMX Cable Infc Source oH L_ df a A oH __ dt eee ES ce oh _ Ed cg ee rs 7 E P E aH dE S S tHL _ EE P ruru gt PO rproro gt 6 B CLN meee A d sf Oh I S E FIG 6 AXB REL8 System Worksheet 93 5774 01 REV A Bl Fak
4. af EAA Overview The AXB REL8 FG5774 controls closure activated devices acting as an eight channel relay control port on the AxLink bus Relay a nirollar Maos f af af gt AXlink FIG 1 AXB REL8 Specifications Ta 1 51 x 5 55 x 5 45 3 84 cm x 14 10 cm x 13 84 cm e With all 8 relays On 170 mA 12 Ge max Included Accessories Metal tab strips included for external adjacent relay com muning 1 51 x 5 55 x 5 45 3 84 cm x 14 10 cm x 13 84 cm FromPeniconpenene AxLink Status indicator AxLink LED green and blinks to indicate AxLink communication activity and power Full Off indicates no power is being received or the controller is not functioning properly One blink per second indicates power is active and AxLink communication is functioning Full On indicates there is no AxLink control or activity but power is On An eight position DIP switch is used to set the device number for the AXB REL8 Illuminate when associated relay is closed Relay LED s should match panel control function AxLink connector Four pin captive wire receives power and information via the AxLink bus and AxLink system controller Device DIP switch Relay LEDs 1 8 Red Relay contacts Eight normally open isolated two pin relay contacts 1 A 28 VAC or VDC e Relays 1 4 can share a common if use jumper A pins with a tab strip e Relays 5 8 use discrete commons wire commons
5. end strip up away from other wiring TA 1 N B wr A CT 2 B LL TA 3 RELAYS SHARING A COMMON B Jumper A pins with tab strip Pi A T 4 o B S A N B P A af 6 B D A CL RELAYS WITH DISCRETE COMMONS 7 i Wire commons individually A 8 i B Z FIG 5 Relay wiring diagram Testing The Installation 1 Check AxLink status LED it should blink once per second see Specifications table for AxLink status LED Relay LED lights but source does not activate Check wiring continuity Check jumpers used for shared commons Check cable and source against supplied documentation Check operational status of interface or source Rack Mounting the AXB REL8 optional To rack mount the AXB REL8 into the optional AC RK Accessory Rack Kit Remove any connected relay and AxLink connectors from the rear panel Remove the two screws on the front panel of the AXB REL8 Remove the front panel and the space bracket behind the panel Place the unit in the appropriate opening in the AC RK Place the front panel of the AXB REL8 on the front of the rack over the unit Fasten the front panel to the rack and to the unit with the two screws you removed oF Or Qh Sl I For full warranty information refer to the AMX Instruction Manual s associated with your Product s 5 12 2012 AMX All rights reserved AMX and the
6. s 1 Strip 0 25 inch of wire insulation off all wires 2 Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section 3 Tighten the screws to secure the wires Do not tighten the screws excessively doing so may strip the threads and damage the connector Wiring Guidelines The interface requires a 12 VDC power to operate properly The interface uses a PSN2 8 power supply The Central Controller supplies power via the AxLink cable or external 12 VDC power supply The maximum wiring distance between the Central Controller and interface is determined by power consumption supplied voltage and the wire gauge used for the cable The table below lists wire sizes and maximum lengths allowable between the REL8 and Central Controller The maximum wiring lengths for using AxLink power are based on a minimum of 13 5 volts available at the Central Controller s power supply Wiring Guidelines at 170 mA Wire Size Maximum Wiring Length AxLink Data and Power Connections Connect the control system s AxLink connector to the AxLink connector on the rear panel of the AXB REL8 for data and 12 VDC power as shown in FIG 3 PWR ut PWR AXP TX MMMM AXP TX AXM RX AXM RX GND GND AXB REL8 Central Controller FIG 3 AxLink wiring Wiring AxLink With Optional 12 VDC Power Supply

Download Pdf Manuals

image

Related Search

Related Contents

画像解析用機能拡張オプションをお使いのお客様へ - psn  HP 465A User's Manual  StarTech.com 0.3m (11in) Short White Apple 8-pin Lightning Connector to USB Cable for iPhone / iPod / iPad    Samsung Delbar varmluftsovn 65 liter BF3Q4W098 Brugervejledning  Philips PSC805 Washer/Dryer User Manual  02 06 08 OWNER'S MANUAL TROUBLESHOOTING  Gebruiksaanwijzing  Atlantic Wall Mount Game Rack  Transmetteur Cond 7050 e Manuel d`instructions  