1. NXD 500i Setup and System Connection 1 Carefully remove the panel from the shipping box peel the protective plastic cover from the LCD and apply power to the panel via the PoE Injector 2 From below the LCD press the Front Bezel button for 9 seconds passing over the Setup page to access the Calibration setup page and follow the on screen instructions to return to the main Setup page 3 Press the on screen Protected Setup button on the Setup page 4 Enter the panel password into the on screen keypad default is 1988 5 Press the Device Number field to open the on screen Device Number keypad and enter a value for the panel default is 32007 6 Press the System Connection button to open the System Connection page 7 Toggle the DHCP Static field to DHCP 8 Toggle the Type field to Ethernet 9 Toggle the Mode field to URL 10 Enter both the System Number and IP Address of the target Master 11 Enter a valid Username and Password if the target Master is secured 12 Press the Back button and then press the on screen Reboot button to save any changes and cycle power to the panel Installation of the NXD 500i While the NXD 500i is designed to fit into pre existing NXD CV5 touch panel sites the actual installation differs from that of the NXD CV5 is several significant ways The NXD 500i can be installed either directly into the optional CB TP5 I Rough In Box or another solid surface environment using either solid s
2. af EFA For more detailed installation configuration programming file transfer and operating instructions refer to the NXD 500i Operation Reference Guide available online at www amx com Microphone Touch screen LEL AA i o z50228 5 288688 Speaker Front Bezel Button Pugon Tini Ring FIG 1 NXD 500i 5 Modero Widescreen WallMount Touch Panel Overview The NXD 500i FG2261 02 widescreen color panel includes a built in microphone speakers a mini USB port for programming and audio output and one NetLinx programmable button All power is supplied via Power Over Ethernet PoE utilizing a PS POE AF PoE Injector FG423 80 or equivalent PoE device The NXD 500i supports Intercom functionality which allows two communicating panels controlled by the NetLinx Master to transmit full duplex audio signals over a network in order to be used as an Intercom system Specifications NXD 500i FG2261 02 Specifications Dimensions HWD NXD 500i with faceplate 4 15 x 5 59 x 1 97 10 50 cm x 14 20 cm x 5 cm e CB TP5 Rough In Wallbox optional 4 27 x 5 14 x 3 40 10 86 cm x 13 06 cm x 8 64 cm Power e PoE Powered No local Power Supply needed Requirements e Max power draw 5 5W Memory Factory e 128 MB SDRAM default e 256 MB integrated Flash Memory not upgradeable factory programmed Certifications e FCC Part 15 Class B e CE IEC 60950 RoHS Panel LCD Parameters Aspect ratio 1
3. installed flush against the mounting surface e Refer to SP 2261 02 for detailed installation dimensions e Cutting out the surface slightly smaller than what is outlined in the installation drawings in order to make any necessary cutout adjustments is highly recommended 1 Prepare the area by removing any screws or nails from the surface before beginning the cutout process Cut out the surface for the NXD 500i Remove the Faceplate bezel from the NXD 500i 4 Gently unscrew the lower right hand screw attaching the NXD 500i to its back box These are at the bottom of the device underneath the touch screen Gently remove the NXD 500i from the back box 5 Thread the incoming Ethernet and USB wiring from their terminal sources through the surface opening Leave enough slack in the wiring to accommodate any re positioning of the panel 6 Connect the Ethernet and USB connectors to their corresponding locations along the left side of the un powered NXD 500i touch panel The USB connectors can be from either a USB extension cable or a wireless USB RF transmitter NOTE Do not disconnect the connectors from the touch panel The unit must be installed with the necessary connectors before being inserted into the solid surface T Carefully slide the main unit into the cutout until the Mounting Tabs of the NXD 500i lie flush against the wall 8 Insert and secure three 4 Mounting Screws not included into the corresponding holes located alo
4. with removal if necessary 8 Insert both connectors into their corresponding locations along the left side of the NXD 500i touch panel 9 Test the incoming wiring by attaching the panel connections to their terminal locations and applying power via the PoE Injector Verify that the panel is receiving power and functioning properly to prevent repetition of the installation NOTE Do not disconnect the connectors from the touch panel The unit must be installed with the attached connectors before being inserted into the drywall 10 Insert the NXD 500i back into the back box 11 The microphone cable is taped to the back box Connect the microphone cable to its connector making sure that the cable does not interfere with reattachment of the Faceplate 12 Carefully replace the two Plastite screws holding the device to the back box 13 Place the Faceplate Trim Ring assembly back onto the device Make sure to align the Microphone Light and PIR Motion sensor locations to their respective openings on the front faceplate bezel 14 Reconnect the terminal Ethernet and USB to their respective locations on either the Ethernet port or NetLinx Master Installing the NXD 500i into a Flat Surface using 4 screws Three 4 mounting screws not included are secured through circular holes located at the left and right sides of the NXD 500i The most important thing to remember when mounting the NXD 500i is that the outer frame Mounting Tabs must be
5. 6 x 9 Maximum brightness luminance 200 cd m2 Channel transparency 8 bit Alpha blending Contrast ratio 250 1 Display colors 256 thousand colors 18 bit color depth Dot pixel pitch 0 14 mm Panel type TFT Color Active Matrix Screen resolution 800 x 480 pixels HV 60 Hz frame frequency Viewing dimensions 4 3 x 2 58 109 2 mm x 65 2 mm 4 25 x 2 55 10 80cm x 6 48cm Viewing Angles e Up Down Left Right 85 85 85 85 IR Reception Angle Horizontal 25 left and right from center e Vertical 15 up and down from center Supported Audio e 48000Hz 44100Hz 32000Hz 24000Hz 22050Hz 16000HZ 12000Hz 11025Hz and 8000Hz Sample Rates e Full duplex VoIP capabilities e Light Sensor Photosensitive light detector for automatic adjustment of the panel brightness e Motion Sensor PIR Proximity Infrared Detector to wake the panel when panel is approached Front Bezel Button Provides both access to the Setup and Calibration pages and toggles the panel between a sleep or wake state This button is also user programmable Microphone Frequency response of 300 to 3400Hz used for intercom applications Speaker Output of 40hm 2 Watts with a 300Hz low cutoff frequency Intercom Front Panel Components Installation Guide NXD 500i 5 Modero Wall Flush Mount Touch Panel NXD 500i Specifications Cont Side Panel Connectors e Ethernet 10 100 Port RJ 45 port for 10 100 Mbps c
6. d with your Product s 2 10 margin for error if the opening needs to be expanded Too little wall material removed is always better than too much 3 Remove the Faceplate bezel from the NXD 500i 4 Gently unscrew the two screws attaching the NXD 500i to its back box These are at the bottom of the device underneath the touch screen Carefully remove the NXD 500i from the back box NOTE While the screws are loosened you can adjust the LCD to ensure it is parallel to the sides of the backbox if necessary While adjusting the LCD is possible it is not required in most cases 5 Thread the incoming Ethernet and mini USB wiring if mini USB access is desired from their terminal locations through the surface opening Leave enough slack in the wiring to accommodate any re positioning of the panel 6 Push the back box into the wall opening Insure that the locking tabs lie flush against the back box 7 Extend the locking tabs on the sides of the back box by tightening the screws inside the box until snug Not all of the tabs must be extended to lock the back box in place but extending a minimum of the top and bottom tabs is highly recommended Apply enough pressure to the screw head to keep the box flush with the wall this ensures that the locking tabs will tighten up against the inside of the wall The back box is clear to allow visual confirmation that the tabs have been extended and are gripping the wall as well as in assisting
7. e of the four faces missing only on the face containing the space for the connections to help lock the backbox to the wall These locking tabs are only extended AFTER the backbox is inserted into the wall WARNING When installing the backbox make sure that the assembly is in the correct position and in the correct place Once the locking tabs are extended and locked into place removing the backbox may be difficult without having access to the back of the wall or causing damage to the wall Note In order to guarantee a stable installation of the NXD 500i the thickness of the wall material must be a minimum of 50 inches 1 27cm and a maximum of 875 inches 2 22cm WARNING The maximum recommended torque to screw in the locking tabs on the plastic back box is 5 IN LB 56 N CM Applying excessive torque while tightening the tab screws such as with powered screwdrivers can strip out the locking tabs or damage the plastic back box 1 Prepare the area by removing any screws or nails from the drywall before beginning the cutout process 2 Cutout the surface for the back box Refer to the dimensions in the NXCD 500i Operation Reference Guide available from www amx com for more information CAUTION Making sure that the actual cutout opening be slightly smaller than the provided dimensions is highly recommended This action provides the installer with a For full warranty information refer to the AMX Instruction Manual s associate
8. ng the sides of the NXD 500i using a grounded Phillips head screwdriver until the unit is secure and flush against the wall 9 The microphone cable is taped to the back box Connect the microphone cable to its connector making sure that the cable does not interfere with reattachment of the Faceplate 10 Carefully replace the two Plastite screws holding the device to the back box 11 Place the Faceplate Trim Ring assembly back onto the device Make sure to align the Microphone Light and PIR Motion sensor locations to their respective openings on the front Faceplate bezel 12 Reconnect the terminal Ethernet and USB to their respective locations on either the Ethernet port or NetLinx Master oN 93 2261 02 REV H 2010 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com ag Aa R LF
9. ommunication The Ethernet port automatically negotiates the connection speed 10 Mbps or 100 Mbps and whether to use half duplex or full duplex mode Power is supplied through Power Over Internet PoE NXD 500i panels communicate with the NetLinx Master using the ICSP protocol over Ethernet LEDs show communication activity connections speeds and mode information L A link activity Yellow LED lights On when the Ethernet cables are connected and terminated correctly and then blinks when receiving Ethernet data packets SPD speed Green LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps e Mini USB Connector 5 pin Mini USB connector used for programming firmware update and touch panel file transfer between the PC and the target panel The connector is also used for providing audio output for external speakers Operating Storage Environments e Operating Temperature 0 C 32 F to 40 C 104 F e Operating Humidity 5 85 relative humidity non condensing e Storage Temperature 20 C 4 F to 60 C 140 F e Storage Humidity 5 85 RH Included e NXD 500i Installation Guide 93 2261 02 Accessories e Front Bezel 60 2261 11 Other AMX e CB TP5i Rough In Wallbox FG038 11 Equipment e Back Cover for the CB TP5i Rough In Wallbox FG038 12 e PS POE AF PoE Injector FG423 80 e CC USB Type A to Mini B 5 wire programming cable FG10 5965 e USB to Headphone Adapto
10. r FG5966 23 e NXA BEZP 500 BL Black Portrait Bezel Kit for NXD 500i FG2261 10 e NXA BEZP 500 SL Silver Portrait Bezel Kit for NXD 500i FG2261 11 e NXA RK5 Rack Mount Kit for 5 Wall Mount panels FG2904 55 5 Rackmount Four Screws 10 32 x 625 PH Truss BLK Four Washers 10 Black Nylon Three Screws 4 40 x 250 PPH BLK Panel Connectors and Wiring FIG 2 shows the connectors located on the NXD 500i Modero panel The mini USB port is used both for programming the touch panel and for audio output The mini USB port automatically detects the presence of a headphone adaptor allowing the port to be used for headphone connectivity Ethernet 10 100 port Mini USB port Back box FIG 2 Connector layout on the NXD 500i Touch Panels For more information on connection and use of the Panel Connectors as well as information on programming and headphone connectivity please refer to the NXD 500i Operation Reference Guide available at www amx com Front Bezel Button The NXD 500i has only one button on the front of the device in the center of the button trim ring This button has several uses e Press the button once to start a previously programmed function or to turn off the display if not previously programmed e Press and hold the button for 6 seconds to put the device into Setup Mode e Press and hold the button for 9 seconds to enter Calibration Mode e Press and hold the button for 20 seconds to reboot the panel
11. urface screws or the included locking tabs for different mounting options For more information please refer to the NXD 500 Operation Reference Guide available at www amx com The NXD 500i is contained within a clear outer housing known as the back box FIG 3 This back box is removed when installing the device into a wall or into a Rough In Box Locking tab screws Locking tabs Closed Locking tabs Open FIG 3 NXD 500i backbox with closed and open locking tabs Removing the Faceplate In certain circumstances the Faceplate must be removed and replaced with a new faceplate Because the device is installed against a wall the faceplate must be removed carefully to prevent the two top prongs from being broken To remove the faceplate 1 Gently lift up on the faceplate from the bottom Do NOT pull up from the sides or the top 2 Let the faceplate fall forward from the top of the device and let it pivot from the bottom 3 Remove the faceplate from the two bottom prongs and install the new trim ring as necessary 4 When reattaching the faceplate to the device make sure to align the Microphone Light and PIR Motion sensor locations on the device to their respective openings on the Faceplate assembly Installing the NXD 500i into a wall Unlike most AMX touchpanels the NXD 500i comes with a clear plastic backbox FIG 7 designed to attach the panel to most standard wall materials This backbox has a locking tab on thre