Home

AMX UPC20+

image

Contents

1. Remote Sensor Control mode The UPC20 can also be controlled via the serial output from an AMX IR sensor Remote sensor mode is selected by setting jumper JP1 to the Remote position jumper on the left 2 pins as shown in FIG 3 The jumper must be in position when power is applied to the UPC20 Contact closure Remote sensor mode mode FIG 3 JP1 mode settings If motors of any kind are used do not set to a Power Control mode When a Power Control mode is selected both relays can be on at the same time Motors can be severely damaged if this happens When controlled by a remote sensor the UPC20 is in 2 3 button timer motor control mode When the timing potentiometer R8 adjusted to zero ohms no time delay the remote sensor provides momentary control A 3 bit code radio code set on DIP switch S2 associates an AMX handheld remote control with a UPC20 This allows up to 8 UPC20 and IR sensors to be used in the same room without interfering with one another It is possible to control 2 separate UPC20 s with one handheld remote control The 4th switch of DIP switch S2 on the PCB selects between the two UPC20 s The table below lists the results of the 16 possible DIP switch selections in remote sensor mode The following table lists the DIP switch settings for Remote Sensor Mode DIP Switch Settings for Remote Sensor Mode Sw 1 Sw 2 Sw 3 Sw 4 Rad
2. UPC20 Control Mode Functions for Inputs 3 and 4 Control Mode S2 Switch R8 Motor Input 1 Input 2 Setting Time Delay P2 pin 5 to GND P2 pin 6 to GND Pot Motor Single But On On Off On Minimum Not used Not used ton Minimum Not used Not used Motor 2 3 Button Off Off Off On Minimum Not used Not used Maximum Not used Not used Motor Momentary Off On Off On Minimum Not used Not used Maximum Not used Not used Power Momentary On On On On Minimum Not used Not used Maximum Not used Not used Power Latching Off On On On Minimum Not used Not used Maximum Not used Not used gg UPC20 Control Mode Functions for Inputs 3 and 4 Cont Control Mode S2 Switch R8 Motor Input 1 Input 2 Setting Time Delay P2 pin 5 to GND 2 pin 6 to GND Pot Power Two Button On Off Off On Minimum Push 3 load 1 off Push 4 load 2 off Release 3 load 1 Release 4 load 2 off still off Maximum Push 3 load 1 off Push 4 load 2 off Release 3 load 1 Release 4 load 2 off still off Power Momen On Off On On Minimum Not used Not used 3 1 Latching Maximum Not used Not used Power Latching On Off On On Minimum Not used Not used 1 Momentary 2 Maximum Not used Not used High Voltage Wiring Options Single circuit 120 240 VAC Single circuit connections FIG 4 are for most motor and sc
3. DIP Switch S2 Provides selection of control mode options See Motor Control Mode DIP Switch S2 Positions table on page 4 and Control Input Wiring to Connector P2 Terminals table on page 4 for control mode settings Enclosure Metal with black matte finish knockouts for conduit Dimension HWD 8 5 10 5 including flange x 4 5 x 2 2 220 mm 270 including flange x 110 mm x 60 mm Weight 3 0 Ibs 1 4 kg with flange Options 12 VDC power supply for 277 VAC applications NOTE Control Options Modes ATTENTION INSTALLER FACTORY SET TO INOPERATIVE MODE UNIT WILL NOT WORK UNTIL DIP SWITCHES ARE SET SEE CHART ON LID TO SET DIP SWITCHES FOR ACTIVE MODE FIG 2 UPC20 inoperative mode warning label If UPC 20 is powered up when changes are made to Dip Switch settings then power must be cycled before changes can take effect Motor Control mode The table list options and connections for motor control DIP switch settings provide 1 2 or 3 button remote control contact arrangements This mode is typically used for screen and drape motor control In motor control mode only one power relay motor can be energized at a time When switching from one direction to another the first motor is automatically turned off and a half second delay is inserted before the other motor will turn on Once a motor is turned on it will automatically be turned off after the amount of time
4. an EAM Operation Reference Guide UPC20 Universal Power Controller Control System Accessories Last Revised 09 12 2007 AMX Limited VVarranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three 3 years from the date of purchase from AMX Corporation vvith the follovving exceptions Electroluminescent and LCD Control Panels are warranted for three 3 years except for the display and touch overlay components that are warranted for a period of one 1 year Disk drive mechanisms pan tilt heads power supplies MX Series products and KC Series products are warranted for a period of one 1 year Unless otherwise specified OEM and custom products are warranted for a period of one 1 year e Software is warranted for a period of ninety 90 days Batteries and incandescent lamps are not covered under the warranty This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform This includes any lost profits lost savings incidental damages or consequential damages AMX Corporation is not liable for any claim made by a third party or by an AMX Dealer for a third party This limitation of liability applies whether damages are sought or a claim is made under this warranty or as a tor
5. 123456789 D D 5 0 0 00D 0 D 12VDC 9 8 3 Y External Power to Circuit Remove emove e Terminal Board Electronics Board Line o Block P1 Power FIG 6 Low voltage and 277 VAC high voltage wiring If motors of any kind are used do not set to a power control mode When a power control mode is selected both relays can be on at the same time Motors can be severely damaged if this happens Wiring The UPC20 to Either The IRX DM Or IRX SM Wire the UPC20 to the sensor as shown in FIG 7 1 2 3 PWR IN GND UPC20 IRX DM or IRX SM connector 2 C 1PWR e 2 AUX OUT 3 OUT ED 4GND Top view FIG 7 Wiring diagram for UPC20 to IRX DM or IRX SM Wireless IR Sensor Connection The wireless IR sensor connections are located on P2 terminals 1 3 Terminal 1 is 12 VDC out terminal 2 is serial data in and terminal 3 is GND The 12 VDC is short circuit protected and the output supplies up to 25 mA for the remote sensor For dual circuit 277 VAC operation remove both 12 AWG wire jumpers Installing the UPC20 To install the UPC20 unit 1 Mount the UPC20 on a wall or solid surface in the location where it will be used it can be mounted either horizontally or vertically Remove the cover Prepare terminal block P1 a Set power switch S1 b Config
6. Off On Minimum Push 1 load 1 on Not used gle Button Release 1 load 1 off Push 1 again load 2 off Minimum Push 1 load 1 on Not used Release 1 load 1 off after delay time out Push 1 again load 2 on Release 1 again 7 load 2 off after time out Note pushing again restarts cycle Motor 2 3 Off Off Off On Minimum Push 1 load 1 on Push 2 load 2 on Button Release 1 load 1 off Release 2 load 2 off Maximum Push 1 load 1 on Push 2 load 2 on Release 1 load 1 off Release 2 load 2 off after time out after time out Note both loads cannot be On at the same time Motor Off On Off On Minimum Push 1 load 1 on Push 2 load 2 on Momentary Release 1 load 1 off Release 2 load 2 off Maximum Push 1 load 1 on Push 2 load 2 on Release 1 load 1 off Release 2 load 2 off Note No delay on release Power On On On On Minimum Push 1 load 1 on Push 2 load 2 on Momentary Release 1 load 1 off Release 2 load 2 off Maximum Push 1 load 1 on Push 2 load 2 on Release 1 load 1 off Release 2 load 2 off Power Off On On On Minimum Push 1 load 1 on Push 2 load 2 on Latching Release 1 load 1 still Release 2 load 2 still on on Push 2 again load off Push 1 again load off Release 2 again load Release 1 again 7 load still off still off Maximum Push 1 load 1 on Push 2 load 2 on Release 2 load 2 s
7. 240 277 VAC Spade terminal block P1 Power and Motor control relays t i Test switches with aw status LEDs 7 vy per Ne DI N 1 e MAE O Motor Time Delay j Potentiometer 47 MOTOR Ogg gi i EL 25 Cia Jumper JP1 CS lt EA MADE IN USA 55 JP1 LISTED IND CONT EQ 68WF SSSS 88 a US 1 234 567 89 3 8 e 822228 UPC20 Low voltage sa J terminal and wiring RECEIVER CONTROL t label 5 fi parve arrangement labe Ig tess cron Bos as s 8 SEE INSIDE COVER FOR DETAILED WIRING Richardson Texas n AND DIP SWITCH INFORMATION 800 222 0193 NOTE NO HIGH VOLTAGE THIS CONNECTION 469 624 8000 The UPC cover contains information on high voltage wiring low voltage wiring and DIP switch settings NOTE Specifications UPC20 Specifications Power Self powered when used with 110 220 VAC Power input for control board 1201240V 50 60 Hz 0 05 0 025A Or 12 VDC 0 2A max Power output per relay 20A 120 240V 50 60 Hz RESISTIVE LOAD 6A 277V 50 60 Hz FLUORESCENT BALLAST 1 HP 120V 50 60 Hz INDUCTIVE LOAD 2 HP 240V 50 60 Hz INDUCTIVE LOAD Total Current through both relays CAN NOT exceed 20 amp Maximum operating ambient temperature 55 C Approvals UL C UL CE Includes 1 2 a
8. Options 10 Single circuit 120 240 VAC sissies dost r sud s suk eper sd eko v ren esi od nds poet ode add eines 10 Dual circuit 120 240 VAGC eec 10 Dual circuit 277 c 11 Wiring The UPC20 to Either The IRX DM 5 11 Wireless IR Sensor Connection teu 11 Installing the UPOZOJ 12 Table of Contents ti UPC20 Un Product Information t NOTE The UPC20 Universal Power Control is a dual 20 Amp AC power and motor controller designed for conduit installation The UPC20 is housed in a compact metal wall mount enclosure and is configurable for a wide variety of power and motor control modes Low voltage contact closures open collector inputs or serial data from an AMX IR receiver enable control by simple wall panels remote systems or hand held transmitters A test switch with an LED indicator for each relay is provided for local control and status indication Using Motor Control mode the UPC20 output alternates between two relays providing a brief pause in between relay contacts to protect the motor A timing adjustment potentiometer is user adjustable for automatic release of the relays The range is 0 to 90 seconds 1 2 and 3 button control modes are selectable In Power Control mode the UPC20 provides power control for two indepen
9. demarks of AMX Corporation In Canada doing business as Panja Inc Last Revision 09 12 07
10. dent circuits with a combined total load of 20 Amps Single button momentary latching and 2 button latching modes are selectable e Momentary Power Relay contacts are closed only as long as a closure from input to common is maintained e Latching Power Relay contacts are toggled from open to closed and closed to open each time a closure from input to common is momentarily pulsed All functions and capabilities of the UPC20 including information on high voltage wiring low voltage wiring and DIP switch settings are described on a sticker installed inside the enclosure FIG 1 shows the UPC20 inside view The UPC20 will work the NXC I O10 input output control card Povver svvitch 115 230 VAC DIP switch controls mode and function Low voltage and IR remote control connections FIG 1 UPC20 im GND RISK OF ELECTRIC SHOCK MORE THAN ONE DISCONNECT SWITCH MAY BE REQUIRED TO DE ENERGIZE THE EQUIPMENT BEFORE SERVICING IMPORTANT GQ G G3 1 GS SWITCH MUST 6 5 4 3 2 1 P1 MATCH INPUT EJ VOLTAGE PRIOR ua e us TO APPLYING hu POWER TO UNIT TO CIRCUIT BD BLK 12ANG ELECTRONICS P USE COPPER ONLY 75 C INSULATION BLK 12AWG 6 NG y JS QKA pi c E High voltage terminal and wiring arrangement label High voltage wiring 120
11. determined by the motor time delay potentiometer R8 Delay time can range from 0 to 90 seconds It is typically set to allow direction limit switches to operate or to reach the desired position Motor Control Mode DIP Switch S2 Positions 1 2 3 4 Control Mode On On Off On Single button Off Off Off On 2 button Off On Off On Momentary On Off e Single Button Mode operates with one pushbutton in a sequence Up Stop Down Stop and so on for each successive button press e Two Three Button Mode operates with two pushbuttons one for Up and one for Down e Momentary On Off operates only when the button is pressed Control Input Wiring to Connector P2 Terminals 4 5 6 7 8 Control Mode Common Up Down Stop N A Two three button Common Up Stop Down N A N A N A Single button D CAUTION Power Control mode The tables below specify the DIP switch settings for momentary latching 2 button On Off and momentary or latching operation of K1 and K2 Power Control Mode DIP Switch Positions S2 1 2 3 4 Control Mode On On On On Momentary On Off Off On On On Latching On Off On Off Off On Two Button On Off On Off On On 1 Momentary 2 Latching Off Off On On 1 Latching 2 Momentary 4 5 6 7 8 Control Mode Common 1 On Off 2 On Off N A N A Momentary Latch On Off Common 1 On 2 On 1 Off 2 Off Two Button On Off
12. ical Code ANSI NFPA 70 1987 as well as all local codes In the European community the UPC20 unit must be wired by an authorized elec trician in accordance with all applicable European codes A readily accessible disconnect device shall be incorporated into the fixed wiring An insulated earthing conductor that is identical in size insulation material and thickness to be earthed and unearthed branch circuit supply conductors except that it is green with or without one or more yellow stripes is to be installed as part of the branch circuit which supplies the unit or system The earthing conductor described is to be connected to earth at the service equipment or supplied by a separately derived system at the supply transformer or motor generator set Table of Contents UPC20 Wiring Requirements sci sdin 3 Product Information gjin 1 era 3 Control Options Modes 4 Motor Control mode eren ho nane Eee ege Eo SEEN eee rre 4 Power Control mode tirer creen a ERN 5 Remote Sensor Control mode Leeeeeee nenen ee enen neve neve veseve e eese esee essa 5 Channel codes Remote Sensor MOde cccssssecccsssccccsesccccsssccccesccecsssscceeesscecescceeesseces 6 esc Pe 7 P1 Terminal Connections oorr hrs SINE 7 P2 Terminal 7 Control Mode atv a eus 7 High Voltage Wiring
13. io UPC20 Code Off Off Off Off 0 First On Off Off Off 1 First Off On Off Off 2 First On On Off Off 3 First Off Off On Off 4 First On Off On Off 5 First Off On On Off 6 First On On On Off 7 First Off Off Off On 0 Second On Off Off On 1 Second Off On Off On 2 Second On On Off On 3 Second Off Off On On 4 Second On Off On On 5 Second Off On On On 6 Second On On On On 7 Second Channel codes Remote Sensor mode The table below lists the 5 AMX channel codes and their function in the UPC20 when in Remote Sensor mode Channel Codes and Functions Channel Function 6 Stop K1 and K2 0 1 up K1 1 1 down K2 7 2 up K1 2 2 down K2 Installation P1 Terminal Connections Low voltage power see the table below for internal circuitry is provided from an on board transformer powered by an external 120 or 240 VAC source An onboard switch is used to select input voltage When using the UPC20 for 277 VAC control the on board internal circuitry is powered by a separate 120 240 VAC line or from an optional 12 VDC power supply P1 Terminal Connections Terminal Input Output Function 1 Output Load 1 out 2 Input Line 1 in 3 Output Load 2 out 4 Input Line 2 in 5 Input Neutral to transformer on PCB which supplies low voltage 6 Input Line to transformer on PCB which supplies low voltage K1 and K2 are the power and motor control relay con
14. nd 3 button logic modes Local test switches with status LEDs 120 240 and 277 VAC control capability Inputs 4 closure inputs operation defined by mode One IR remote sensor input Motor Control mode alternates between the timed operation of the two power relays Power Control mode allows independent control of both power relays Control Ports Two 2400 W power relays Total combined current through both relays is 20 Amps Input Power Switch S1 Set this switch according to the high voltage wiring that will be connected to terminals 5 and 6 on P1 Refer to theP1 Terminal Connections section on page 7 Set switch S1 to the line input voltage value used before applying power to the UPC20 High Voltage Terminal Block P1 High voltage input and output wiring for motor or power control Low voltage and Control Terminal Block P2 Contact closure open collector or CMOS logic level remote control wiring Inputs 5 8 are referenced to the common connection at pin 4 Jumper JP1 Sets control mode of the unit to contact closure or remote sensor serial data Test Switches PB1 and PB2 Provides local operation of relays K1 and K2 for testing power circuits or motors connected to the relay terminals An LED indicates relay power applied Motor Time Delay Potentiometer R8 Only used in motor control modes User adjusted for setting relay release time between 0 and 90 seconds
15. nections to P1 terminals 1 and 2 3 and 4 respectively Each relay is capable of switching the following loads e Resistive Load 20 Amps at 120 240 VAC e Fluorescent Ballast 6 Amps at 277 VAC e Inductive Load 1 HP The maximum total combined current through both relays is 20 Amps There are two 12 gauge jumpers that are wired to supply board power at 120 240 VAC and to connect the common terminals of the relays The jumpers are removed as needed according to the wiring options selected P2 Terminal Connections The table below defines the inputs and outputs for Terminal P2 P2 Low Voltage Terminal Inputs Outputs Terminal Input Output 1 12 VDC out Serial data in IR sensor Ground Ground common Input 1 Input 2 Input 3 Input 4 12 VDC in OO Ol NI OD a AJ OJN Control Mode The table below defines the control mode functions for Inputs 1 and 2 The UPC20 Control Mode Functions for Inputs 3 and 4 table on page 9 defines the control mode functions for Inputs 3 and 4 i UPC20 Control Mode Functions for Inputs 1 and 2 Release 1 load 1 still on Push 1 again load off Release 1 again load still off Note Both loads can be On at the same time time delay does not affect Control S2 Switch R8 Motor Input 1 Input 2 Mode Setting Time Delay P2 pin 5 to GND P2 pin 6 to GND Pot Motor Sin On On
16. reen control applications Load Load or or MotorLine Motor 2 1 T Terminal Block P1 Neut Line 1 Line 2 and Line to transformer are common 9 FIG 4 Single circuit 120 240 VAC power wiring Dual circuit 120 240 VAC Dual circuit connections provide power from two 120 240 VAC supply systems FIG 5 shows a dual circuit 120 240 VAC power wiring Refer to FIG 1 on page 2 for the location of the Terminal Block P1 on the circuit board Neut Line Load Line Load 1 2 2 1 1 SERE 5 4 3 2 1 Line 1 in and Line to transformer are common Line 2 in is an independent circuit ej 6 Terminal E 5 Block P1 Power U FIG 5 Dual circuit 1207240 VAC povver vviring CAUTION Dual circuit 277 VAC Dual circuit connections provide power from 277 VAC for fluorescent ballasts FIG 6 Circuit board power is provided by a separate 120 240 VAC high voltage circuit or 12 VDC connected to terminals 1 and 6 on the low voltage terminal block For dual circuit 120 240 VAC operation remove the short 12 AWG wire jumper For Dual 277 VAC Circuits Power Circuit Board Electronics From 12 VDC or 120 240 VAC 120 240 i Line Neut Line Load Line Load i i 2 2 1 1 Line 1 in Line 2 in and Line to transformer are all independent Terminal Block P2
17. t claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be waived or amended by any person This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such dam ages This limitation of liability however will not apply to claims for personal injury Some states do not allow a limitation of how long an implied warranty last Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products In such states the limitation or exclusion of the Limited Warranty may not apply This Limited Warranty gives the owner specific legal rights The owner may also have other rights that vary from state to state The owner is advised to consult applicable state laws for full determination of rights EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY AMX CORPORATION MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AMX CORPORATION EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY gt gt UPC20 Wiring Requirements In the United States the UPC20 must be wired by an authorized electrician in accordance with the National Electr
18. till on Push 2 again load off Release 2 again load still off UPC20 Control Mode Functions for Inputs 1 and 2 Cont Control S2 Switch R8 Motor Input 1 Input 2 Mode Setting Time Delay P2 pin 5 to GND P2 pin 6 to GND Pot Povver 2 On Off Off On Minimum Push 1 load 1 on Push 2 load 2 on Button Release 1 load 1 still Release 2 load 2 still on on Maximum Push 1 load 1 on Push 2 load 2 on Release 1 load 1 still Release 2 load 2 still on on Note Both loads can be On at the same time Power On Off On On Minimum Push 1 load 1 on Push 2 load 2 on Momentary Release 1 load 1 off Release 2 load 2 still on 1 Latch Push 2 in load 2 off ing 42 ush 2 again loa o Release 2 again load 2 still off Maximum Push 1 load 1 on Push 2 load 2 on Release 1 load 1 off Release 2 load 2 still on Push 2 again load 2 off Note Delay time does not Release 2 again load 2 effect loads still off Power Minimum Push 1 load 1 on Push 2 load 2 on Momentary Release 1 load 1 still Release 2 load 2 off 1 Latch on ing 2 Push 1 again load 1 off Release 1 again load 1 still off Maximum Push 1 load 1 on Push 2 load 2 on Release 1 load 1 still Release 2 load 2 off on Push 1 again load 1 off Release 1 again load 1 still off Note Delay time does not affect loads
19. ure jumpers according to high voltage wiring requirements Install conduit Provide conduit for high voltage low voltage and control wiring requirements using the 0 5 inch or 0 75 inch conduit connector knockouts Connect high voltage wiring to the terminal block PI Connect control wiring a Set control mode DIP switch S2 and control jumper JP1 Refer to the Control Options Modes section on page 4 for more detailed information b Install wiring for contact closure or remote control mode Test low voltage and high voltage wiring Conduct tests to confirm proper installation and functions of desired control modes Installation TM AMX reserves the right to alter specifications vvithout notice at any time ARGENTINA AUSTRALIA BELGIUM BRAZIL CANADA CHINA ENGLAND FRANCE GERMANY GREECE HONG KONG INDIA INDONESIA ITALY JAPAN LEBANON MALAYSIA MEXICO NETHERLANDS NEW ZEALAND PHILIPPINES PORTUGAL RUSSIA SINGAPORE SPAIN SWITZERLAND THAILAND TURKEY USA ATLANTA BOSTON CHICAGO CLEVELAND DALLAS DENVER INDIANAPOLIS LOS ANGELES MINNEAPOLIS PHILADELPHIA PHOENIX PORTLAND SPOKANE TAMPA 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA 800 222 0193 469 624 8000 469 624 7153 fax 800 932 6993 technical support www amx com 041 004 2236 9 07 2007 AMX Corporation All rights reserved AMX the AMX logo the building icon the home icon and the light bulb icon are all tra