Home

Premier CMF flat panel wall mount

image

Contents

1. Electronic Stud Finder Ys Drill Bit Hand Held Drill Pencil Phillips Tip Screwdriver Tape Measure Hammer Parts List Make sure none of the Premier Mounts parts are missing and or damaged before beginning installation If there are stop the installation and call Premier Mounts at 800 368 9700 CMF Components 10 x 1 M4 x 20mm Wood Screw Pan Combo Screw Qty 2 Qty 4 M5 x 20mm M6 x 20mm Pan Combo Screw Pan Combo Screw CMF Qty 1 Qty 4 Qty 4 M4 Spacer M5 Spacer Qty 4 Qty 4 M8 x 20mm Bolt Spindle Pan Combo Screw Bolt Spindle with Kickstand Spindle Extension Mansy Qty 4 Qty 1 Qty 1 Qty 4 Black Vinyl Cap M5 Security Allen Qty 4 Wrench Qty 1 Installation Instructions Visit the Premier Mounts website at http www premiermounts com Page 3 gt 4 22 CMF Premier Mounts Low Profile Cable Mount for Flat Panels up to 55 CMF makes installing a flat panel as simple as hanging a picture frame The CMF s slim design and patent pending magnetically assisted installation feature MagnaGuide makes it the ideal flat panel accessory for fast and simple installations This cable mount easily installs on a single stud and to hold flat panel displays up to 55 or up to 65 Ibs with a 200 x 200mm to 600 x 400mm VESA mounting pattern Use the collapsible wall stand off leg included on one of the bottom flat panel anchors to prop up the flat panel for easy A V and pow
2. Insert one 1 10 x 1 wood screw into each mounting hole of the mount sliding plate Figure 4 A Do not overtighten the wood screws Go to the Attaching the Bolt Spindles to the Flat Panel section on page 6 Figure 3 Installation Instructions Visit the Premier Mounts website at http www premiermounts com Page 5 gt lt 4 24 CMF Attaching the Bolt Spindles to the Flat Panel Refer to the flat panel installation instructions to determine the type of screws you will use in the mounting installation fy M4 M5 M6 and M8 screws are supplied with the CMF _ Pan Combo Screw Insert the appropriate screw and spacer into each bolt spindle Figure 1 Bolt Spindle If the flat panel has a rear protrusion greater than Spacer the depth of the bolt spindles attach one 1 spindle extension to each of the bolt spindles Figure 2 The spindle extensions add 7 in depth Figure 1 Attach the two 2 bolt spindles that are attached to the cable mounting plate to the top two 2 mounting locations on the back of the flat panel Figure 3 You may need to loosen the cabling by simultaneously pushing down the lever on the back of the cable mounting plate and pulling the bolt SG spindle cabling Figure 4 Bolt Spindle Attach the two 2 loose bolt spindles to the bottom two Figure 2 2 mounting locations on the back of the flat panel Figure 5 Continue on page 7 Fi
3. INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO INABILITY TO USE ITS PRODUCTS OR LABOR COSTS FOR REMOVING AND REPLACING DEFECTIVE PRODUCTS OR PARTS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to the address below within thirty 30 days Proof of purchase an original sales receipt from the original consumer purchaser must accompany all warranty claims Warranty claims must also include a description of the problem the purchaser s name address and telephone number General inquiries can be addressed to Premier Mounts Customer Service at 1 800 368 9700 Warranty claims will not be accepted over the phone or by fax Premier Mounts Attn Warranty Claim 3130 East Miraloma Ave Anaheim CA 92806 How State Law Applies THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE Premier Mounts intends to make this manual accurate and complete However Premier Mounts makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document
4. CMF Low Profile Cable Mount for Flat Panels up to 55 INSTALLATION INSTRUCTIONS cD PREMIER Cat MOUNTS CREATING POSITIVE CUSTOMER EXPERIENCES 9531 058 001 00 V R O z T Weight EiMiti messes eE E E E E a E aaa 2 Vamig Seme asa a S E O Cees tee E NS 2 Installation TOONS isna a a den T a a E E A EEE 3 Pans ENS tiesvscissaccaacanasaavdeusvanaarsde hanmataneexsanasteasiacacasies sand a aaa N a a ATN 3 Feature Sirna n EEE a AA a a a Aa a a aa 4 Installing the Mount Sliding Plate to a Wood Stud sicisisosiosiii ii inieriiiiii aE aANT EA 5 Usma the KICKS tanden S OAN 8 Technical Specifications eenegen iaa a a a A E RAE 8 AE N E A E A E E A E E E E E E E A 9 Weight Limit THE WALL STRUCTURE MUST BE CAPABLE OF l l SUPPORTING AT LEAST FIVE TIMES THE WEIGHT OF Maximum Flat Panel Weight 6 5 bs THE FLAT PANEL IF NOT THE WALL STRUCTURE MUST BE REINFORCED Warning Statements PRIOR TO THE INSTALLATION OF THIS PRODUCT THE INSTALLATION INSTRUCTIONS MUST BE READ AND v COMPLETELY UNDERSTOOD KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED AS OUTLINED IN THESE INSTALLATION INSTRUCTIONS FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE SERIOUS PERSONAL INJURY OR EVEN DEATH SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT USE PROPER SAFETY EQUIPMENT AND TOOLS
5. FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS AND IS NOT RESPONSIBLE FOR ANY DAMAGES CLAIMS DEMANDS SUITS ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM ARISING OUT OF OR IN ANY MANNER RELATING TO ANY SUCH USE ATTACHMENTS OR MODIFICATIONS Be aware of the mounting environment If drilling and or cutting into the mounting surface always make sure that there are no electrical wires in wall Cutting or drilling into an electrical line may cause serious personal injury Make sure there are no water or natural gas lines inside the wall where the mount is to be located Cutting or drilling into a water or gas line may cause severe property damage or personal injury This product is intended for indoor use only Use of this product outdoors could lead to product failure and or serious personal injury Do not install near sources of high heat Do not install on a structure that is prone to vibration movement or chance of impact Contact Premier Mounts with any questions 800 368 9700 techsupport mounts com Page 2 Visit the Premier Mounts website at http www premiermounts com Installation Instructions 4 CMF D2 Installation Tools The following tools may be required depending on your installation r
6. er access Add spacers which are included with the cable mount kit to align the display or to create more room between the display and wall Page 4 MagnaGuide Simplifies flat panel hanging by aligning the cable mounting plate and mount sliding plate together behind the display Bolt Peg Connects cabling to the back of the display Cable Braided steel cable Kickstand Holds the flat panel up to 4 from the wall making it easy to connect A V components from the back Visit the Premier Mounts website at http www premiermounts com Installation Instructions CMF 22 Installing the Mount Sliding Plate to a Wood Stud Remove the mount sliding plate from the cable mounting plate Figure 1 Use a stud finder and pencil to mark the center of a wall stud Place the mount sliding plate on wall and align its screw holes with the center mark The visual centering diamond on the mount Goble Mounting sliding plate will help you determine where the center of the flat panel will be on the wall Figure 1 Use a pencil to mark the two 2 screw hole locations along the stud Figure 2 Visual Centering Remove the mount sliding plate Diamond Drill two 2 holes in the center of each screw hole location using a power drill and a 1 drill bit Figure 3 A Only use a drill bit when drilling holes aay Mount Sliding Figure 1 Place the mount sliding plate against the wall and align it with the holes
7. gure 3 Back view of cable mounting plate Figure 4 Figure 5 Page 6 Visit the Premier Mounts website at http www premiermounts com Installation Instructions CMF Attaching the Bolt Spindles to the Flat Panel con d Attach one 1 black vinyl cap to each of the bolt spindles Figure 1 Pull on the crimp at the end of the cables to tighten the tension on the bolt spindle cabling Figure 2 Wrap the excess cabling around the teeth on the cabling mounting plate then tuck the crimp inside Figure 3 Continue to the Attaching the Flat Panel to the Wall section below Crimp Flat panel not shown Figure 2 Attaching the Flat Panel to the Wall Slide the flat panel and cable mounting plate into the mount sliding plate on the wall Figure 1 At least two qualified persons are needed to perform this step Use the CMF s MagnaGuide feature to easily align the plates together Use the M5 security Allen wrench and pre installed M5 x 16mm security screw to secure the cable mounting plate to the mount sliding plate Figure 2 Go to the Using the Kickstand section on page 8 Installation Instructions Visit the Premier Mounts website at http www premiermounts com M5 x 16mm security screw Bolt Spindle Figure 1 Wrap excess cabling around the plastic teeth Figure 3 Page 7 b a Ce CMF Using the Kickstand Use the kickstand on
8. is subject to change without notice or obligation of any kind Premier Mounts makes no representation of warranty expressed or implied regarding the information contained herein Premier Mounts assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Contact Us NORTH AMERICA EUROPE 3130 East Miraloma Avenue Unit 3 The Moorings Business Park eat E USA Channel Way Longford and Canada ET T ETTE Coventry CV6 6RH UK Prone 1 800308 900 Phone 44 0 24 7664 4105 Fax 1 800 832 4888 Other Locations Phone 001 714 632 7100 Fax 001 714 632 1044 Fax 44 0 24 7664 4165 Premier Mounts 2011 Installation Instructions Visit the Premier Mounts website at http www premiermounts com Page 9
9. the lower bolt spindle to prop up the flat panel for easy power and cable management Kick Stand Side view of flat panel and bolt spindles Technical Specifications All measurements are in inches millimeters 1 28 3 52 3243 89 39 Page 8 Visit the Premier Mounts website at http www premiermounts com Installation Instructions UN CMF e PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original owner of this product The limited warranty is valid only for the original purchaser of the product What Premier Mounts Will Do At the sole option of Premier Mounts Premier Mounts will repair or replace any product or product part that is defective If Premier Mounts chooses to replace a defective product or part a replacement product or part will be shipped to you at no charge but you must pay any labor costs What is Not Covered Limitations PREMIER MOUNTS DISCLAIMS ANY LIABILITY FOR DAMAGE TO MOUNTS ADAPTERS DISPLAYS PROJECTORS OTHER PROPERTY OR PERSONAL INJURY RESULTING IN WHOLE OR IN PART FROM IMPROPER INSTALLATION MODIFICATION USE OR MISUSE OF ITS PRODUCTS PREMIER MOUNTS DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE PREMIER MOUNTS IS NOT RESPONSIBLE FOR