Home

Huawei S5700-28C-PWR-EI

image

Contents

1. 3700 amp S5700 amp S6700 Series Ethernet Switches V200R001C01 Quick Start Issue 02 Date 2012 09 10 Wz HUAWEI TECHNOLOGIES CO LTD HUAWEI Copyright Huawei Technologies Co Ltd 2012 All rights reserved No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co Ltd Trademarks and Permissions uawa and other Huawei trademarks are trademarks of Huawei Technologies Co Ltd All other trademarks and trade names mentioned in this document are the property of their respective holders Notice The purchased products services and features are stipulated by the contract made between Huawei and the customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the preparation of this document to ensure accuracy of the contents but all statements information and recommendations in this document do not constitute a warranty of any kind express or implied Huawei Technologies Co Ltd Address Huawei Industrial Base Bantian Longgang Shenzh
2. Set the authentication method to AAA user name to huawei and password to huawei Set the service type to telnet and user level to 15 Configure AAA authentication for the users at the vty 0 to vty 4 levels SwitchA aaa SwitchA aaa local user huawei password simple huawei SwitchA aaa local user huawei service type telnet SwitchA aaa local user huawei privilege level 15 SwitchA aaa quit SwitchA user interface vty 0 4 SwitchA ui vty0 4 authentication mode aaa SwitchA ui vty0 4 return lt SwitchA gt 7 Verify the configuration CO note When the administrator logs in to SwitchA through Telnet ensure that the PC of the administrator and SwitchA are reachable at the network layer lt SwitchA gt telnet 127 0 0 1 Teying 127 030 Press CTRL T to abort Connected to 127 0 0 1 KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK i All rights reserved 2005 2007 Without the owner s prior written consent x no decompiling or reverse engineering shall be allowed Notice E This is a private communication system Unauthorized access or use may lead to prosecution KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK Login authentication Username huawei Password Note The max number of VTY users is 15 and the current number of VTY users on line is 3 lt SwitchA gt Issue 02 2012 09 10 Huawei Proprietary and Confidential 60 Copyright
3. Pe mee UNUM EA e T AE weer ere Vem ree vewg A E ey tear reer strat ere Vers A Perera teary Ramer trey men wer E eer Z T ETEO a a deen sey aacumonaateinddnes ei aacoeseesncneaatiece wads acey cu teens cuearaaevencen 9 24 S3700 Indicator Desert aeiae aoaea r ae tea a A AEA AAAA EE REA 10 23 aa 00 adicaor Descrip Oieee EAEE E ee eRe 13 ZD O Nr DE Re i a T sau tacglonaun Sasa bactuanuameshcenesesseca 42 3 Device staan ion ea anaes 47 4 Powering on the Device inucsietsinccunsiininiemnninnn eens 48 11 Checking Belore Power Oi gach iha cea acd eaien ee Lawn dae ae Ga ee OR 49 Aaronon onie DEN On ie eee enn Inte PEE CRT Meer eere eer e CeeT TPP Te Ter oR RC rete TUR R 53 A3 Checking Aiter Powe HO Lis i iat cacsstenc a a aE a aa Ea A ERE EE A EERE A ASIER 53 amp Locsin intothe Dorie osisssa a E SS 54 5 1 Logging In to th Swatch Through the Console nterlace oe c cis aicavescassseuss snseeshvossarseevseanct eons essersttwas ans sienai an 5 2 Example for Configuring to Manage the SwitchThrough Telnet ceceeessecseeeeceseeeeeeceaeeecaecaseeeeaeeaeeaeens 58 So Loro me ah Tee This Ve Ss ete ANGEL ccc ceaccesandsccodantentoiqasycaaeaceGh wads eE E RA 61 6 Service Deploy metoren ene 63 7 Op taini e Documenta O seiras aaia iaia iaaa kEi 64 Issue 02 2012 09 10 Huawei Proprietary and Confidential iv Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 1 Overview 1 Overview This
4. Orange If a single power supply unit is installed the PoE power is out of range If two power supply units are installed the card power or PoE power is out of range System status The system is not indicator operating Green The system is not operating properly or is starting Orange The system is performing self check during startup Blinking green The system is operating properly After registering the system does not operate properly or a power alarm fan alarm or temperature alarm is generated The service interface indicator is in the default mode STAT indicator Issue 02 2012 09 10 Huawei Proprietary and Confidential 34 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction The service interface indicator indicates the interface speed After 45 seconds the service interface indicator automatically restores to off The service interface indicator indicates the PoE status After 45 seconds the service interface indicator automatically restores to off The service interface indicator indicates the stack ID After 45 seconds the service interface indicator automatically restores to off As shown in Figure 2 9 the button marked 5 is the mode switching button On an S5700 you can press the mode switching button to switch the display modes of interface indicators The status of
5. automatically restores to STAT Issue 02 2012 09 10 Huawei Proprietary and Confidential 38 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Mode MODE When you press switching the button once button the SPED indicator turns green and the service interface indicators show the speed status of interfaces When you press the button for a second time the STCK indicator turns green and the service interface indicators show the stack status of interfaces When you press the button for a third time the PoE indicator turns green and the service interface indicators show the PoE status When you press the button for a fourth time the STAT indicator turns green If you do not press the button within 45 seconds the indicators restore to the default status That is the STAT indicator turns green and the SPED STCK and PoE indicators are off Issue 02 2012 09 10 Huawei Proprietary and Confidential 39 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Service GE The meanings of interface electrical service interface Green indicator interfaces be indicators vary The first Blinking green according to the indicator indicator status For shows the details see Table status of 2 18 the bottom left inter
6. to off The following table describes the meanings of indicators M note PWR is at the side of the chassis Table 2 20 Description of indicators in different modes STAT The interface is not connected or has been shut down The interface is connected Blinking green The interface is sending or receiving data Off The interface is not connected or has been shut down a interface speed is 1000 Mbit Blinking green The interface speed is 10 Gbit s Stack The stack ID of the member switch is not the number of the interface in the off state Green The device is a not a command switch Ifthe indicator of an interface is always on the number of this interface is the stack ID of the device If the first nine interface indicators of the device are always on the stack ID of the device is 0 Issue 02 2012 09 10 Huawei Proprietary and Confidential 45 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Blinking green The device is a command switch Ifthe indicator of an interface blinks the number of this interface is the stack ID of the device If the first nine interface indicators of the device blink the stack ID of the device is 0 Issue 02 2012 09 10 Huawei Proprietary and Confidential 46 Copyright Huawei Technologies Co Ltd S3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 3 Device I
7. 10 Gbit s SFP optical interfaces working in auto sensing mode and changing to GE interfaces S 5710 28C PWR LI 28 There are twenty 10 100 1000BASE T Ethernet interfaces four GE combo interfaces 10 100 1000BASE T 100 1000BASE X and four interfaces on the front subcard Issue 02 2012 09 10 Huawei Proprietary and Confidential 6 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Produ ct Series 5710 52C PWR LI 5710 28C LI 5710 52C LI S5700S S5700S 28P LI AC S5700S 52P LI AC Naming Rules Maximum Number of Interfaces 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four interfaces on the front subcard 28 There are twenty 10 100 1000BASE T Ethernet interfaces four GE combo interfaces 10 100 1000BASE T 100 1000BASE X and four interfaces on the front subcard 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four interfaces on the front subcard 28 There are twenty four 10 100 1000BASE T Ethernet interfaces and four 1 OOOBASE X Ethernet optical interfaces 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four 1 OOOBASE X Ethernet optical interfaces The following are the naming rules of the 5710 28C EI S5700S 52P LI AC S5700 48TP PWR SI S5700 28C EI 24S and S5700 28C HI Issue 02 2012 09 10 Huawei Proprietary and Co
8. Product Hardware Introduction The service interface indicator indicates the stack ID After 45 seconds the service interface indicator automatically restores to off As shown in Figure 2 5 the button marked 5 is the mode switching button When you press the mode switching button once the mode indicator turns green and the related interface indicator enters the speed state When you press the mode switching button for a second time the mode indicator turns red and the related interface indicator represents the stack status When you press the mode switching button for a third time the mode indicator restores to the default state off If you do not press the mode switching button within 45 seconds the mode indicator automatically restores to off The following table describes the meanings of indicators Table 2 8 Description of indicators in different modes STAT Off The interface is not connected or has been shut down The intertic s connected Blinking green The interface is sending or receiving data SO S interface is not connected or SO S been shut down 10M 100M 1000M interface The interface is operating at 10 100 Mbit s 1000M 10G interface The interface is operating at 1000 Mbit s Blinking green 10M 100M 1000M interface The interface is operating at 1000 Mbit s 1000M 10G interface The interface is operating at 10 Gbit s Stack Off The stack ID of the member switch is not the number of the i
9. a mode indicator represents the display mode of the related interface indicator For example the mode indicator of S5700 28C PWR EI is off and the interface indicators are in STAT state by default When you press the mode switching button once the mode indicator turns green and the related interface indicator enters the speed state When you press the mode switching button for a second time the mode indicator turns orange and the related interface indicator represents the PoE power status When you press the mode switching button for a third time the mode indicator turns red and the related interface indicator represents the stack status When you press the mode switching button for a fourth time the mode indicator restores to the default state off If you do not press the mode switching button within 45 seconds the mode indicator automatically restores to off The following table describes the meanings of indicators Table 2 16 Description of indicators in different modes STAT Off The interface is not connected or has been shut down The ntertie i comedted Issue 02 2012 09 10 Huawei Proprietary and Confidential 35 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Blinking green The interface is sending or receiving data Off The interface is not connected or has been shut down 10M 100M 1000M interface The interface is operating
10. number of this interface is the stack ID of the device If the first nine interface indicators of the device blink the stack ID of the device is 0 2 6 S6700 Indicator Description This section describes the indicators on the S6700 front panel Indicators of S6700 Switch In the following description the indicators of S6700 24 EI are described as an example Issue 02 2012 09 10 Huawei Proprietary and Confidential 42 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Figure 2 11 S6700 24 EI indicators Table 2 19 Description of S6700 24 EI indicators 1 Power The power supply indicator units are not present or the power supply is abnormal when a single power supply unit is used Two power supply units are installed properly but not switched on The power supply units are switched off The power supply units are faulty Power The power supply indicator units are not present or the power supply is abnormal when a single power supply unit is used Green The power supply is normal Issue 02 2012 09 10 Huawei Proprietary and Confidential 43 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Two power supply units are installed properly but not switched on The power supply units are switched off
11. operating at 1000 Mbit s 1000M 10G interface The interface is operating at 10 Gbit s Off The interface does not provide PoE power Green The interface is providing PoE power Orange The PoE function on the interface is disabled Blinking orange A PoE fault occurs For example an incompatible cable or PD is connected to the interface or the PoE power supply unit is faulty Issue 02 2012 09 10 Huawei Proprietary and Confidential 41 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Blinking green and orange The interface cannot provide alternately power to PDs The possible reasons including The power of a connected PD exceeds the interface s powering capability or upper power supply threshold The power provided by the switch has reached the powering capability of the switch The PoE power function is not enabled on the interface in manual power management mode Stack Off The stack ID of the member switch is not the number of the interface in the off state Green The device is a not a command switch Ifthe indicator of an interface is steady on the number of this interface is the stack ID of the device If the first nine interface indicators of the device are steady on the stack ID of the device is 0 Blinking green The device is a command switch Ifthe indicator of an interface blinks the
12. or the power supply is the right abnormal when a single power supply unit is used Green The switch is powered on Orange Possible causes are as follows Two power supply units are installed but not switched on The power supply units are not connected properly A power supply unit is faulty From the rear PWR2 The power supply view power units are not present indicator on or the power supply is the left abnormal when a single power supply unit is used Green The switch is powered on Orange Possible causes are as follows Two power supply units are installed but not switched on The power supply units are not connected properly A power supply unit is faulty 3 System status SYS The system is not indicator operating Issue 02 2012 09 10 Huawei Proprietary and Confidential 27 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Blinking green The system is starting quickly 4 Hz Blinking green The system is slowly 0 5 Hz operating properly Blinking orange The system is 0 5 Hz sleeping The system does not operate properly or a power alarm fan alarm is generated The indicator is not in indicator the STAT mode The service interface indicator is in the default mode STAT The indicator is not in indicator the speed mode Green The service interface indicator indica
13. password for authentication when you relog in to the system in password authentication mode using this user interface End Follow up Procedure Ifthe prompt lt Quidway gt is displayed on the screen it indicates that the Command Line Interface CLI is displayed In this case you can enter commands to configure or manage the 3700 S 5700 S6700 For details on configuration procedures see the following sections 5 2 Example for Configuring to Manage the SwitchThrough Telnet Issue 02 2012 09 10 Huawei Proprietary and Confidential 58 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 5 Logging in to the Device Networking Requirements As shown in Figure 5 5 SwitchA is newly added to the network SwitchA and SwitchB are connected through a trunk link To enable the network administrator to manage SwitchA remotely you need to configure the Telnet service and set the device name on SwitchA Figure 5 5 Networking diagram of managing SwitchA through Telnet administrator SwitchB GE 0 0 1 RS 232 serial port Console port a x Console cable PC SwitchA GE 0 0 1 Configuration Roadmap The configuration roadmap is as follows 1 Log in to SwitchA through the console interface 2 Set the device name 3 Configure a management VLAN 4 OnSwitchA set the type of the interface that connects SwitchA and SwitchB to trunk Add the interface t
14. 8C HI 24S 5700 28C HI S 5700 28C PWR SI 5700 52C PWR SI S5700T S5700 24TP SI AC P 5700 24TP SI DC S5700 48TP SI AC S 5700 48TP SI DC S5700 24TP PWR SI S5700 48TP PWR SI Maximum Number of Interfaces 28 There are twenty four 100 1000BASE X Ethernet optical interfaces and four interfaces on the front subcard 28 There are twenty four 10 100 1000BASE T Ethernet interfaces and four interfaces on the front subcard 28 There are twenty 10 100 1000BASE T Ethernet interfaces four GE combo interfaces 10 100 1000BASE T 100 1000BASE X and four interfaces on the front subcard 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four interfaces on the front subcard 24 There are twenty 10 100 1000BASE T Ethernet interfaces and four GE combo interfaces 10 100 1000BASE T 100 1000BASE X 24 There are twenty 10 100 1000BASE T Ethernet interfaces and four GE combo interfaces 10 100 1000BASE T 100 1000BASE X 48 There are forty four 10 100 1000BASE T Ethernet interfaces and four GE combo interfaces 10 100 1000BASE T 100 1000BASE X 48 There are forty four 10 100 1000BASE T Ethernet interfaces and four GE combo interfaces 10 100 1000BASE T 100 1000BASE X 24 There are twenty 10 100 1000BASE T Ethernet interfaces and four GE combo interfaces 10 100 1000BASE T 100 1000BASE X 48 There are forty four 10 100 1000BASE T Ethernet interfaces and four GE combo interfa
15. Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 5 Logging in to the Device Configuration Files SwitchA sysname SwitchA vlan batch 1 vlan 1 description admin_VLAN interface Vlanifl ip address 10 10 10 10 255 255 255 0 interface GigabitEthernet0 0 1 port link type trunk port trunk allow pass vlan 1 aaa local user huawei password simple huawei local user huawei service type telnet local user huawei privilege level 15 authentication scheme default authorization scheme default accounting scheme default domain default user interface con 0 user interface vty 0 4 authentication mode aaa return 5 3 Logging In to the Web System Client Before configuring the switch you must log in to the Web system client Context Procedure Step 1 Step 2 Before logging in to the Web system client ensure that the switch has been commissioned and the Web system server is enabled on the switch The Web system client connects to the switch through HTTP therefore you must log in to the Web system client through HTTP It is recommended that the Web system client should run the Windows XP operating system because other operating systems may be imcompatible with the web system And the Web system client supports the Microsoft Internet Explorer 6 0 IE6 and Firefox 3 0 or later versions The Web system client described in this document uses the IE6 Open Micr
16. S5700 24TP SI AC S5700 24TP SI DC S5700 48TP SI AC and S5700 48TP SI DC have redundant power supply RPS indicators Figure 2 5 5700 24TP SI AC indicators Issue 02 2012 09 10 Huawei Proprietary and Confidential 15 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Table 2 7 Description of S5700 24TP SI AC indicators The switch is powered indicator off Green The switch is powered on Orange The power supply unit is faulty and the external RPS system has started oe The RPS is not connected to the switch or the RPS is faulty Green The RPS is connected to the switch System status SYS The system is not indicator operating Green The system is not operating properly or is starting Orange The system is performing self check during startup Blinking green The system is operating properly After registering the system does not operate properly or a power alarm fan alarm or temperature alarm is generated The service interface indicator indicator is in the default mode STAT Green The service interface indicator indicates the interface speed After 45 seconds the service interface indicator automatically restores to off Issue 02 2012 09 10 Huawei Proprietary and Confidential 16 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2
17. The power supply units are faulty The system is not operating Green The system is not operating properly or is starting Orange The system is performing self check during startup Blinking green The system is operating properly System status indicator Mode indicator The service interface indicator is in the default mode STAT Green The service interface indicator indicates the interface speed After 45 seconds the service interface indicator automatically restores to off The service interface indicator indicates the stack ID After 45 seconds the service interface indicator automatically restores to off After registering the system does not operate properly or a power alarm fan alarm or temperature alarm is generated Issue 02 2012 09 10 Huawei Proprietary and Confidential 44 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction As shown in Figure 2 11 the button marked 5 is the mode switching button When you press the mode switching button once the mode indicator turns green and the related interface indicator enters the speed state When you press the mode switching button for a second time the mode indicator turns red and the related interface indicator represents the stack status If you do not press the mode switching button within 45 seconds the mode indicator automatically restores
18. at 10 100 Mbit s 1000M 10G interface The interface is operating at 1000 Mbit s Blinking green 10M 100M 1000M interface The interface is operating at 1000 Mbit s 1000M 10G interface The interface is operating at 10 Gbit s The interface does not provide remote power Green The interface is providing remote power Blinking green The power of the powered device PD exceeds the power supply capability of the port or exceeds the threshold The stack ID of the member switch is not the number of the interface in the off state The device is a not a command switch Ifthe indicator of an interface is steady on the number of this interface is the stack ID of the device If the first nine interface indicators of the device are steady on the stack ID of the device is 0 Issue 02 2012 09 10 Huawei Proprietary and Confidential 36 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Blinking green The device is a command switch Ifthe indicator of an interface blinks the number of this interface is the stack ID of the device If the first nine interface indicators of the device blink the stack ID of the device is 0 Figure 2 10 S5700 28P PWR LI AC indicators Table 2 17 Description of S5700 28P PWR LI AC indicators Power The switch is indicator powered off Green The switch is powered o
19. awei Proprietary and Confidential 24 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Green The service interface indicator indicates the interface speed After 45 seconds the service interface indicator automatically restores to off Red The service interface indicator indicates the stack ID After 45 seconds the service interface indicator automatically restores to off As shown in Figure 2 7 the button marked 5 is the mode switching button When you press the mode switching button once the mode indicator turns green and the related interface indicator enters the speed state When you press the mode switching button for a second time the mode indicator turns red and the related interface indicator represents the stack status When you press the mode switching button for a third time the mode indicator restores to the default state off If you do not press the mode switching button within 45 seconds the mode indicator automatically restores to off The following table describes the meanings of indicators Table 2 12 Description of indicators in different modes STAT Off The interface is not connected or has been shut down Green The interface is connected Blinking green The interface is sending or receiving data Speed Off The interface is not connected or has been shut down Green 10M 100M 1000M interface The interfa
20. cators of a PoE 5700 The 5700 28C PWR EI and S5700 28P PWR LI AC are PoE switches Figure 2 9 5700 28C PWR EI indicators Issue 02 2012 09 10 Huawei Proprietary and Confidential 32 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Table 2 15 Description of 5700 28C PWR E I indicators Power The power supply indicator units are not present or the power supply is abnormal when a single power supply unit is used Green The power supply is normal Red Two power supply units are installed properly but not switched on The power supply units are switched off The card power and PoE power are abnormal If a single power supply unit is installed the PoE power is out of range If two power supply units are installed the card power or PoE power is out of range Power PWR2 Off The power supply indicator units are not present or the power supply is abnormal when a single power supply unit is used Green The power supply is normal Issue 02 2012 09 10 Huawei Proprietary and Confidential 33 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Two power supply units are installed properly but not switched on The power supply units are switched off The card power and PoE power are abnormal
21. ce is operating at 10 100 Mbit s 1000M 10G interface The interface is operating at 1000 Mbit s Issue 02 2012 09 10 Huawei Proprietary and Confidential 25 Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction a o Green Blinking green Figure 2 8 5710 28C EI indicators 10M 100M 1000M interface The interface is operating at 1000 Mbit s 1000M 10G interface The interface is operating at 10 Gbit s The stack ID of the member switch is not the number of the interface in the off state The device is a not a command switch Ifthe indicator of an interface is steady on the number of this interface is the stack ID of the device If the first nine interface indicators of the device are steady on the stack ID of the device is 0 The device is a command switch Ifthe indicator of an interface blinks the number of this interface is the stack ID of the device If the first nine interface indicators of the device blink the stack ID of the device is 0 Issue 02 2012 09 10 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 26 S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Table 2 13 Description of 5710 28C EI indicators From the rear PWR1 The power supply view power units are not present indicator on
22. ces 10 100 1000BASE T 100 1000BASE X Issue 02 2012 09 10 Huawei Proprietary and Confidential 5 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Produ Model Maximum Number of Interfaces ct Series S5700P S5700 28P LI AC 28 There are twenty four 10 100 1000BASE T Ethernet interfaces and four 1 OOOBASE X Ethernet optical interfaces S 5700 28P LI DC 28 There are twenty four 10 100 1000BASE T Ethernet interfaces and four 1 OOOBASE X Ethernet optical interfaces S 5700 52P LI AC 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four 1 OOOBASE X Ethernet optical interfaces S 5700 52P LI DC 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four 1 OOOBASE X Ethernet optical interfaces S5700 28P PWR LI AC 28 There are twenty four 10 100 1000BASE T Ethernet interfaces and four 1 OOOBASE X Ethernet optical interfaces S5700 52P PWR LI AC 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four 1 OOOBASE X Ethernet optical interfaces S5710 S5710 28C EI 28 There are twenty 10 100 1000BASE T Ethernet interfaces four GE combo interfaces 10 100 1000BASE T 100 1000BASE X and four 10 Gbit s SFP optical interfaces working in auto sensing mode and changing to GE interfaces S5710 52C EI 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four
23. ction has an The Mini USB port is arrowhead not in use This pointing to the indicator is steady CON port green unless the Mini USB port is accessed Table 2 10 Description of service interface indicators in different modes STAT Off The interface is not connected or has been shut down The interface is connected Blinking green The interface is sending or receiving data The interface is not connected or has been shut down 10M 100M 1000M interface The interface is operating at 10 100 Mbit s 1000M 10G interface The interface is operating at 1000 Mbit s Blinking green 10M 100M 1000M interface The interface is operating at 1000 Mbit s 1000M 10G interface The interface is operating at 10 Gbit s The stack ID of the member switch is not the number of the interface in the off state The device is a not a command switch Ifthe indicator of an interface is steady on the number of this interface is the stack ID of the device If the first nine interface indicators of the device are steady on the stack ID of the device is 0 Issue 02 2012 09 10 Huawei Proprietary and Confidential 22 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Blinking green The device is a command switch Ifthe indicator of an interface blinks the number of this interface is the stack ID of the device If th
24. d version Downlink interface type The value 24S indicates that 24 downlink interfaces of the S5700 28C EI 24S are optical interfaces NOTE If this letter is not displayed all downlink interfaces are electrical interfaces Powering mode AC alternating current power DC direct current power 2 3 S6700 Introduction This section describes device models and naming rules of the S6700 Device Models To meet diverse customer requirements the S6700 provides a variety of models Table 2 3 lists these device models You can select a device model as required Table 2 3 Device models Maximum Number of Interfaces S6700 S6700 24 EI Twenty four 10G SFP optical interfaces Issue 02 2012 09 10 Huawei Proprietary and Confidential 9 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Produ Maximum Number of Interfaces ct Series La S6700 48 EI Forty eight 10G SFP optical interfaces Naming Rules The following are the naming rules of the S6700 48 EI Figure 2 3 Naming rules S6700 48 El Ide Description ntifi ee B Product series 67 indicates the 6700 series 0 series 67 indicates the S6700 series Maximum number of interfaces The number of interfaces on an S6700 can be 24 or 48 depending on the device model Software version type EI enhanced version supporting enhanced featu
25. document helps you quickly learn how to use the S3700 S5700 S6700 Figure 1 1 shows the quick start contents This section provides an overview of quick start Figure 1 1 Quick start contents Describes switch models and Indicators on each model Provides reference for device installation Describes precautions to take before and after you power on a switch Describes how to log in to a switch Provides reference for deploying services on a switch Obtaini Helps you obtain product documentation quickly Docume Issue 02 2012 09 10 Huawei Proprietary and Confidential 1 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Product Hardware Introduction About This Chapter This section describes models and indicators of low end switches 2 1 3700 Introduction This section describes device models and naming rules of the 3700 2 2 5700 Introduction This section describes device models and naming rules of the 5700 2 3 S6700 Introduction This section describes device models and naming rules of the S6700 2 4 3700 Indicator Description This section describes the indicators on the S3700 front panel 2 5 5700 Indicator Description This section describes the indicators on the S5700 front panel 2 6 S6700 Indicator Description This section describes the indicators on the S6700 front panel Issue 02 2012 09 10 Huawei Pro
26. e first nine interface indicators of the device blink the stack ID of the device is 0 The 5700 28C EI and 5710 28C EI are non PoE switches with dual power supply units Figure 2 7 5700 28C EI indicators Table 2 11 Description of 5700 28C EI indicators Power The power supply indicator units are not present or the power supply is abnormal when a single power supply unit is used Two power supply units are installed properly but not switched on The power supply units are switched off The power supply units are faulty Issue 02 2012 09 10 Huawei Proprietary and Confidential 23 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction The power supply indicator units are not present or the power supply is abnormal when a single power supply unit is used Two power supply units are installed properly but not switched on The power supply units are switched off The power supply units are faulty System status Off The system is not indicator operating The system is not operating properly or is starting The system is performing self check during startup After registering the system does not operate properly or a power alarm fan alarm or temperature alarm is generated The service interface indicator indicator is in the default mode STAT Issue 02 2012 09 10 Hu
27. ecking After Power on Check the following items after the device is powered on The sound of fan rotating can be heard and that the air exhaust from the air vents can be felt The indicators of the power modules run normally Normally the INPUT and OUTPUT indicators are on The indicators of the fan modules run normally Normally the STATUS indicator is on Issue 02 2012 09 10 Huawei Proprietary and Confidential 53 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 5 Logging in to the Device Logging in to the Device About This Chapter This section describes how to log in to the device 5 1 Logging In to the Switch Through the Console Interface 5 2 Example for Configuring to Manage the SwitchThrough Telnet 5 3 Logging In to the Web System Client Before configuring the switch you must log in to the Web system client Issue 02 2012 09 10 Huawei Proprietary and Confidential 54 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 5 Logging in to the Device 5 1 Logging In to the Switch Through the Console Interface Context When establishing the configuration environment through the console interface you can log in to the 3700 S5700 S6700 through the HyperTerminal in Windows Procedure Step 1 Start the HyperTerminal Choose Start gt All Program gt Accessories gt Communications
28. ed as follows Boldface The keywords of a command line are in boldface Italic Command arguments are in italics Items keywords or arguments in brackets are optional x y Optional items are grouped in braces and separated by vertical bars One item is selected xly Optional items are grouped in brackets and separated by vertical bars One item is selected or no item is selected Optional items are grouped in braces and separated by vertical bars A minimum of one item or a maximum of all items can be selected Optional items are grouped in brackets and separated by vertical bars Several items or no item can be selected The parameter before the amp sign can be repeated 1 to n times A line starting with the sign is comments Change History Updates between document issues are cumulative Therefore the latest document issue contains all changes made in previous issues Changes in Issue 02 2012 09 10 Some contents are modified according to updates in the product such as features and commands Changes in Issue 01 2012 07 25 Initial commercial release Issue 02 2012 09 10 Huawei Proprietary and Confidential iii Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start Contents Contents About This Docimeabasvssrasanaa ii TOVON IOW A ean 1 2 Product Hardware Intoductioi ssena NE 2 ec RPO a C TEIN 2223 ac da cod aban r E R E 3
29. en 518129 People s Republic of China Website http www huawei com Email support huawei com Issue 02 2012 09 10 Huawei Proprietary and Confidential i Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start About This Document About This Document Intended Audience This document describes how to verify basic functions of the 3700 S5700 and S6700 during the deployment to ensure stable and reliable running of the S3700 S5700 and S6700 on the network This document is intended for Data configuration engineers Commissioning engineers Network monitoring engineers System maintenance engineers Symbol Conventions The symbols that may be found in this document are defined as follows Indicates a hazard with a high level of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium or low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance degradation or unexpected results Issue 02 2012 09 10 Huawei Proprietary and Confidential ii Copyright Huawei Technologies Co Ltd S3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start About This Document Command Conventions The command conventions that may be found in this document are defin
30. face The indicators correspond to the interfaces from bottom to top and from left to right GE optical interfaces Each optical interface has a correspond ing indicator above it Mini USB The indicators Off The Mini USB port is indicator for the Mini not in use USB port and B CON port are Green The Mini USB port is close to each 1n use other The Mini USB indicator has an arrowhead pointing to the Mini USB port CON The indicators The Mini USB port is indicator for the Mini in use USB port and CON port are close to each other The CON indicator Issue 02 2012 09 10 Huawei Proprietary and Confidential 40 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction has an The Mini USB port is arrowhead not in use This pointing to the indicator is steady CON port green unless the Mini USB port is accessed Table 2 18 Description of service interface indicators in different modes STAT Off The interface is not connected or has been shut down The interface is connected Blinking green The interface is sending or receiving data OO E l interface is not connected or C E l been shut down 10M 100M 1000M interface The interface is operating at 10 100 Mbit s 1000M 10G interface The interface is operating at 1000 Mbit s Blinking green 10M 100M 1000M interface The interface is
31. forming self check during startup Blinking green The system is operating properly Red After registering the system does not operate properly or a power alarm fan alarm or temperature alarm is generated Mode Off The service interface indicator indicator is in the default mode STAT The service interface indicator indicates the interface speed After 45 seconds the service interface indicator automatically restores to off The service interface indicator indicates the stack ID After 45 seconds the service interface indicator automatically restores to off As shown in Figure 2 4 the button marked 5 is the mode switching button When you press the mode switching button once the mode indicator turns green and the related interface indicator enters the speed state When you press the mode switching button for a second time the mode indicator turns red and the related interface indicator represents the stack status When you press the mode switching button for a third time the mode indicator restores to the default state off If you do not press the mode switching button within 45 seconds the mode indicator automatically restores to off The following table describes the meanings of indicators Table 2 5 Description of indicators in different modes STAT Off The interface is not connected or has been shut down Issue 02 2012 09 10 Huawei Proprietary and Confidential 12 Copyright Huawei Tech
32. g ETH indicator daia has an arrowhead pointing to the ETH port Table 2 14 Description of service interface indicators in different modes STAT The interface is not connected or has been shut down The interface is connected Blinking green The interface is sending or receiving data The interface is not connected or has been shut down 10M 100M 1000M interface The interface is operating at 10 100 Mbit s 1000M 10G interface The interface is operating at 1000 Mbit s Blinking green 10M 100M 1000M interface The interface is operating at 1000 Mbit s 1000M 10G interface The interface is operating at 10 Gbit s Issue 02 2012 09 10 Huawei Proprietary and Confidential 31 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction The stack ID of the member switch is not the number of the interface in the off state The device is a not a command switch Ifthe indicator of an interface is steady on the number of this interface is the stack ID of the device If the first nine interface indicators of the device are steady on the stack ID of the device is 0 Blinking green The device is a command switch Ifthe indicator of an interface blinks the number of this interface is the stack ID of the device If the first nine interface indicators of the device blink the stack ID of the device is 0 Indi
33. gt HyperTerminal to start the HyperTerminal in Windows XP Step 2 Set up a connection See Figure 5 1 Enter the name of the new connection in the Name text box and then choose one icon Then click OK Figure 5 1 Setting up a connection Connection Description a New Connection Enter a name and choose an ican for the connection Step 3 Configure an interface for connection In the Connect To dialog box as shown in Figure 5 2 select an interface from the drop down list box according to the actual interface on the PC or terminal Next click OK Issue 02 2012 09 10 Huawei Proprietary and Confidential 55 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 5 Logging in to the Device Figure 5 2 Configuring the interface for connection Connect To B COMM1 Enter details for the phone number that you want to dial Country region Area code Phone number Step 4 Set communication parameters When the COM1 Properties dialog box is displayed as shown in Figure 5 3 specify the parameters listed in Table 5 1 QO note In other Windows operating systems bits per second may be described as baud rate and data stream control may be described as traffic control Issue 02 2012 09 10 Huawei Proprietary and Confidential 56 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 5 Logg
34. he switch is sleeping pressing the MODE button can waken the switch The system does not operate properly or a power alarm fan alarm is generated Red STAT STAT Off The indicator is not in indicator the STAT mode Green The service interface indicator is in the default mode STAT ff Speed SPED O The indicator is not in indicator the speed mode Green The service interface indicator indicates the interface speed After 45 seconds the service interface indicator automatically restores to STAT STCK Off The indicator is not in indicator the stack mode Green The service interface indicator indicates the stack information After 45 seconds the service interface indicator automatically restores to STAT Issue 02 2012 09 10 Huawei Proprietary and Confidential 19 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Blinking green The indicator indicates the active device in a stack ora device not added toa stack Mode MODE When you press switching the button once button the SPED indicator turns green and the service interface indicators show the speed status of interfaces When you press the button for a second time the STCK indicator turns green and the service interface indicators show the stack status When you press the button for a third time the STAT indicator turns green If you do no
35. i Proprietary and Confidential 50 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 4 Powering on the Device The card is installed and removed easily The screws on the panel should be appropriately tightened and easily disassembled The spring wire is intact The cabinet surface must be tidy and clean the components of the cabinet cannot be distorted all identifiers are correct clear and complete The cabinet is kept clean and there are no excessive binding straps and other articles in the cabinet The ESD wrist straps are connected the ESD jack in the chassis 11 Blank panels are installed in all empty slots Cable Installation Checklist Table 4 2 describes the cable installation checklist Table 4 2 Cable installation checklist 1 The power cables and ground cables must be the copper wires and have no splice The cables are safely connected complying with standards Issue 02 2012 09 10 Huawei Proprietary and Confidential 51 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 4 Powering on the Device 2 The power cables and ground cables are connected safely The spring washer of the ground cable terminal is on the flat washer 3 The lugs of the power cables and ground cables are soldered or crimped tightly The power cables and ground cables are not crossed and are separated fro
36. ication It is recommended that you use your work email to register as an equipment customer for login to Huawei support website For any help contact Huawei technical support engineers Obtain the product documents from http enterprise huawei com by choosing Support gt Documentation Center gt IP Network amp Security gt Switches Online Help The online help is integrated and released with the product software You can view the online help by Issue 02 2012 09 10 Huawei Proprietary and Confidential 64 Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 7 Obtaining Documentation Selecting Help on the NMS interface Pressing F1 on any interface of the NMS Release Documents Release documents are released with the software package You can apply to Huawei technical support personnel for the documents Issue 02 2012 09 10 Huawei Proprietary and Confidential 65 Copyright Huawei Technologies Co Ltd
37. icator shows the status of the bottom left interface The indicators correspond to the interfaces from bottom to top and from left to right GE optical interfaces Each optical interface has a correspond ing indicator above it Service interface indicator Green Mini USB indicator USB port CON port and ETH port are close to each other The Mini USB indicator has an arrowhead pointing to the Mini USB port Green Blinking green The meanings of service interface indicators vary according to the indicator status For details see Table 2 14 The indicators Off The Mini USB port is for the Mini not in use The Mini USB port is in use The Mini USB port is in use 10 CON The indicators indicator for the Mini USB port CON port and ETH port are close to each Issue 02 2012 09 10 Huawei Proprietary and Confidential 30 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction other The The Mini USB port is CON indicator not in use This has an indicator is steady arrowhead green unless the Mini pointing to the USB port is accessed CON port 11 ETH The indicators Off The interface is not indicator for the Mini connected USB port 7 7 CON port and Green The interface is ETH port are connected close to each Blinking green The interface is other Tie sending or receivin
38. ing in to the Device Figure 5 3 Specifying parameters COM1 Properties Port Settings Bits per second Data bits Parity Stop bits Flow control Table 5 1 Parameters Bit per second baud rate 9600 Data bit Parity check Stop bit Flow control traffic control Step 5 After the HyperTerminal starts choose FileAttributes to display the COMM1 Properties dialog box as shown in Figure 5 4 On the Setting tab select VT100 in the Emulation drop down list box Click OK to complete the setting Issue 02 2012 09 10 Huawei Proprietary and Confidential 57 Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 5 Logging in to the Device Figure 5 4 Selecting the terminal type COMM1 Properties Connect To Settings Function arrow and ctrl keys act as Terminal keys O Windows keys Backspace key sends Cth Del Cti H Space Ctri H Telnet terminal ID VT100 Backscroll buffer lines 500 C Play sound when connecting or disconnecting Input Translation ASCII Setup Step 6 Press Enter At the following command line prompt set an authentication password The system automatically saves the set password Please configure the login password maximum length 16 Enter Password Confirm Password QO note After the password for the user interface is set successfully during the first login you must enter this
39. m other The redundant part of the power cables and ground cables should be cut The cables cannot be circled Labels are filled and attached to power cables and PGND cables power cables and PGND cables including power distribution switches are labeled correctly and clearly Labels are attached 20 mm from the connector The clearance between the power cable PGND cable and signal cable must be more than 30 mm Table 4 3 describes the cabinet cable checklist Table 4 3 Cabinet cable checklist mo um O a Cables are correctly connected 2 Cable ties are not overlapped and connectors are smooth Table 4 4 describes the signal cable checklist Issue 02 2012 09 10 Huawei Proprietary and Confidential 52 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 4 Powering on the Device Table 4 4 Signal cable checklist 3 1 All the signal cables to be deployed pass the continuity check 2 No signal cable is placed on the heat dissipation holes of the cabinet 3 The bent part of a signal cable cannot be too tight 4 The cables in the cabinet cannot be crossed and the cables outside the cabinet are bound The two ends ofa signal cable are clearly identified by labels and the texts on the labels are in the same direction The bolts that fix the cables are tightened 4 2 Powering on the Device Turn on the power module of the device 4 3 Ch
40. mer requirements the S5700 provides a variety of models Table 2 2 lists these device models You can select a device model as required Table 2 2 Device models Produ ct Series S 5700 28C EI S 5700 28C EI 24S S 5700 52C EI S5700 28C PWR EI S 5700 52C PWR EI 5700 28C SI 5700 52C SI Maximum Number of Interfaces 28 There are twenty four 10 100 1000BASE T Ethernet interfaces and four interfaces on the front subcard 28 There are twenty 100 1000BASE X Ethernet optical interfaces four GE combo interfaces 10 100 1000BASE T 100 1000BASE X and four interfaces on the front subcard 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four interfaces on the front subcard 28 There are twenty four 10 100 1000BASE T Ethernet interfaces and four interfaces on the front subcard 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four interfaces on the front subcard 28 There are twenty 10 100 1000BASE T Ethernet interfaces four GE combo interfaces 10 100 1000BASE T 100 1000BASE X and four interfaces on the front subcard 52 There are forty eight 10 100 1000BASE T Ethernet interfaces and four interfaces on the front subcard Issue 02 2012 09 10 Huawei Proprietary and Confidential 4 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Produ ct Series S5700 2
41. n The power supply unit is faulty and the external RPS system has started System status Off The system is not indicator operating Blinking green The system is starting quickly 4 Hz Blinking green The system is slowly 0 5 Hz operating properly Blinking orange The system is 0 5 Hz sleeping Issue 02 2012 09 10 Huawei Proprietary and Confidential 37 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Red The system does not operate properly or a power alarm fan alarm is generated STAT STAT Off The indicator is not in indicator the STAT mode Green The service interface indicator is in the default mode STAT 4 Speed SPED Off The indicator is not in indicator the speed mode Green The service interface indicator indicates the interface speed After 45 seconds the service interface indicator automatically restores to STAT 5 Stack STCK E indicator is not in indicator E stack mode The service interface indicator indicates the stack ID After 45 seconds the service interface indicator automatically restores to STAT Blinking green The indicator indicates the active device in a stack or a device not added to a stack PoE indicator PoE Off The indicator is not in the PoE mode The service interface indicator indicates the PoE status After 45 seconds the service interface indicator
42. nfidential Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Figure 2 2 Naming rules 95710 28C El ABC EFH 95 700S 52P LI AC ABCDEFH J S5700 48TP PWR SI E GH S5700 28C El 24S S5700 28C HI H Ide Description ntifi er B Product series 57 indicates the S5700 series Product subseries D The value S indicates business model E Maximum number of interfaces NOTE The number of interfaces on an S5700 can be 24 28 48 or 52 depending on the device model Issue 02 2012 09 10 Huawei Proprietary and Confidential 8 Copyright Huawei Technologies Co Ltd S3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Description Uplink interface type C A device supports interface subcards There can be two four or eight uplink interfaces an interface subcard TP A device has combo interfaces supporting optical and electrical interfaces P A device has optical interfaces The 5700 supports Power over Ethernet PoE NOTE If this letter is not displayed PoE is not supported Software version type EI enhanced version supporting enhanced features SI standard version supporting basic features HI advanced version supporting high performance Operation Administration and Maintenance OAM and built in real time clock RTC LI simplifie
43. nologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction The intertie is connected Blinking green The interface is sending or receiving data Off The interface is not connected or has been shut down Green The interface is operating at 10 100 Mbit s Blinking green The interface is operating at 1000 Mbit s Off The stack ID of the member switch is not the number of the interface in the off state The device is a not a command switch Ifthe indicator of an interface is always on the number of this interface is the stack ID of the device If the first nine interface indicators of the device are always on the stack ID of the device is 0 Blinking green The device is a command switch Ifthe indicator of an interface blinks the number of this interface is the stack ID of the device If the first nine interface indicators of the device blink the stack ID of the device is 0 2 5 S5700 Indicator Description This section describes the indicators on the S5700 front panel The indicator meanings of the S5700 vary with models as listed in Table 2 6 Issue 02 2012 09 10 Huawei Proprietary and Confidential 13 Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Table 2 6 Indicator meanings and corresponding models Device Model Indicator T
44. nstallation 3 Device Installation This section describes how to install the S3700 S5700 S6700 For details on device installation see the 2700 amp 3700 amp 5700 amp 6700 Quick Installation Guide CI note You can obtain the paper documentation of the quick start from delivered accessories To obtain the electronic documentation of the quick start see Where to Obtain Documentation Issue 02 2012 09 10 Huawei Proprietary and Confidential 47 Copyright Huawei Technologies Co Ltd S3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 4 Powering on the Device Powering on the Device About This Chapter This section describes the check items and the procedure for powering on and powering off the device 4 1 Checking Before Power on After hardware installation is complete you need to check the device installation and cable installation 4 2 Powering on the Device 4 3 Checking After Power on Issue 02 2012 09 10 Huawei Proprietary and Confidential 48 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 4 Powering on the Device 4 1 Checking Before Power on After hardware installation is complete you need to check the device installation and cable installation M note Before power on you need to check the device cabinet cables connectors sockets labels and on site environment Device Installation Checklist A CAUTION Befo
45. nterface in the off state Issue 02 2012 09 10 Huawei Proprietary and Confidential 17 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Green The device is a not a command switch Ifthe indicator of an interface is steady on the number of this interface is the stack ID of the device If the first nine interface indicators of the device are steady on the stack ID of the device is 0 Blinking green The device is a command switch Ifthe indicator of an interface blinks the number of this interface is the stack ID of the device If the first nine interface indicators of the device blink the stack ID of the device is 0 Figure 2 6 5700 28P LI AC indicators Table 2 9 Description of S5700 28P LI AC indicators Power The switch is indicator powered off Green The switch is powered on The power supply unit is faulty and the external RPS system has started Issue 02 2012 09 10 Huawei Proprietary and Confidential 18 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction System status SYS Off The system is not indicator operating Blinking green The system is starting quickly 4 Hz Blinking green The system is slowly 0 5 Hz operating properly Blinking orange The system is 0 5 Hz sleeping NOTE When t
46. o the management VLAN in trunk mode 5 Configure the management IP address of SwitchA 6 Configure the Telnet service Data Preparation To complete the configuration you need the following data ID ofthe management VLAN Management IP address of SwitchA Number of the interface that connects SwitchA and SwitchB on SwitchA J Authentication mode user name and password Configuration Procedure 1 Log in to SwitchA through the console port For details see Logging In to the Switch Through the Console Interface Issue 02 2012 09 10 Huawei Proprietary and Confidential 59 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 5 Logging in to the Device 2 Set the device name of SwitchA lt Quidway gt system view Quidway sysname SwitchA 3 Configure a management VLAN SwitchA vlan 1 SwitchA vlanl description admin VLAN 4 OnSwitchA set the type of the interface that connects SwitchA and SwitchB to trunk Add the interface to the management VLAN in trunk mode SwitchA interface Gigabitethernet 0 0 1 SwitchA GigabitEthernet0 0 1 port link type trunk SwitchA GigabitEthernet0 0 1 port trunk allow pass vlan 1 SwitchA GigabitEthernet0 0 1 quit 5 Configure the management IP address of SwitchA SwitchA interface vlanif 1 SwitchA Vlanifl ip address 10 10 10 10 255 255 255 0 SwitchA Vlanifl quit 6 Configure the Telnet service on SwitchA
47. osoft Internet Explorer 6 0 on the client Enter the universal resource locator URL of the Web system client in the address bar and press Enter The User Login dialog box is displayed as shown in Figure 5 6 The URL is in the format http IP view login html for example http 10 164 19 131 view login html Issue 02 2012 09 10 Huawei Proprietary and Confidential 61 Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 5 Logging in to the Device Figure 5 6 User Login User Login w v v HUAWEI User Name admin Password eeeceee Verify Code x5wy XSWY Change Language English x l Save my password Login Reset Step 3 Enter values in User Name Password and Verify Code The local switch provides a default account The user name and password of the account are admin To create change or delete user names and passwords choose Security gt AAA gt User Management Users at levels 0 1 and 2 have only visit level rights and can view only the Ping and Tracert pages after logging in to the client Step 4 Choose a language for example English The Web system client of the current version supports Chinese and English After logging in to the client you can select another language from the Language drop down list on the top right corner of the page Step 5 Click Login CO note If you select Save my password before clicking Login you do no
48. prietary and Confidential 2 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction 2 1 S3700 Introduction This section describes device models and naming rules of the 3700 Device Models Currently S3700 only has one model as described in Table 2 1 Table 2 1 Device models Maximum Number of Interfaces 26 S 3700 26C HI There are twenty two 10 100BASE T Ethernet interfaces two GE combo interfaces 10 100 1000BASE T 100 1000BASE X and two interfaces on the front subcard Naming Rules Figure 2 1 describes the naming rules of the 3700 26C HI Figure 2 1 Naming rules 3700 26C HI Ide Description ntifi er A Product series 37 indicates the S3700 series Maximum number of interfaces Uplink interface type C A device supports interface cards There can be two uplink interfaces on an interface subcard E Software version type HI advanced version supporting high performance Operation Administration and Maintenance OAM and built in real time clock RTC Issue 02 2012 09 10 Huawei Proprietary and Confidential 3 Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction 2 2 5700 Introduction This section describes device models and naming rules of the S5700 Device Models To meet diverse custo
49. re power on all the power distribution cabinets and power distribution frames must be off Table 4 1 describes the device installation checklist Table 4 1 Device installation checklist 1 The cabinet is installed according to the Check the cabinet according to the dimensions on the design paper project design document 2 The expansion bolts for fixing the cabinet or base support to the ground are fastened The plain washer spring washer and nut bolt are installed correctly Issue 02 2012 09 10 Huawei Proprietary and Confidential 49 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 4 Powering on the Device The installation holes on the support and Use the multimeter to measure the the expansion bolts adapt to each other resistance between the bolt and the to ensure insulation between the support ground bolt of the rack The resistance and the ground and between the floor bracket and the guide rail The surfaces of the cabinets in the same row should be on the same plane The cabinets are arranged closely and tidily The cabinets on the sides of the main path are aligned The position error should be less than 5 mm The accessories of the front and rear doors are completely installed and the connection board is installed for combining cabinets The front door of a cabinet can be opened and closed easily Issue 02 2012 09 10 Huawe
50. res 2 4 S3700 Indicator Description This section describes the indicators on the 3700 front panel S3700 26C HI is a non PoE switch that supports two power supply units Figure 2 4 3700 26C HI indicators Issue 02 2012 09 10 Huawei Proprietary and Confidential 10 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Table 2 4 Description of S3700 26C HI indicators Power No power supply unit indicator is installed or the power supply is abnormal when a single power supply unit is used Green The power supply is normal Red Two power supply units are installed properly but not switched on The power supply units are switched off The power supply units are faulty Power WR2 Off The power supply indicator units are not present or the power supply is abnormal when a single power supply unit is used Red Two power supply units are installed properly but not switched on The power supply units are switched off The power supply units are faulty System status SYS Off The system is not indicator operating Green The system is not operating properly or is starting Issue 02 2012 09 10 Huawei Proprietary and Confidential 11 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction The system is per
51. t need to enter the user name and password at next login After you log in to the Web system the main page is displayed For details about the main page see Window Layout End Issue 02 2012 09 10 Huawei Proprietary and Confidential 62 Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 6 Service Deployment Service Deployment This section describes service deployment For details on service deployment see the corresponding configuration guides Issue 02 2012 09 10 Huawei Proprietary and Confidential 63 Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 7 Obtaining Documentation 7 Obtaining Documentation You can obtain product documentation online help and release documents in various ways Product Documents Table 7 1 shows how to obtain product documents Table 7 1 Obtaining product documents How to Obtain Documentation HedEx Library Single Electronic Document Installation From the electronic From http ia ere delivered with support huawei com the equipment From http From http enterprise huawei com support huawei com From the local Huawei representative office Version upgrade From http support huawei com From the local Huawei representative office M note Obtain the product documents from http support huawei com by choosing Documentation gt Data Commun
52. t press the button within 45 seconds the indicators restore to the default status That is the STAT indicator turns green and the SPED and STCK indicators are off Issue 02 2012 09 10 Huawei Proprietary and Confidential 20 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Service GE The meanings of interface electrical service interface Green indicator interfaces be indicators vary The first Blinking green according to the indicator indicator status For shows the details see Table status of 2 10 the bottom left interface The indicators correspond to the interfaces from bottom to top and from left to right GE optical interfaces Each optical interface has a correspond ing indicator above it Mini USB The indicators Off The Mini USB port is indicator for the Mini not in use USB port and B CON port are Green The Mini USB port is close to each 1n use other The Mini USB indicator has an arrowhead pointing to the Mini USB port CON The indicators The Mini USB port is indicator for the Mini in use USB port and CON port are close to each other The CON indicator Issue 02 2012 09 10 Huawei Proprietary and Confidential 21 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introdu
53. tes the interface speed After 45 seconds the service interface indicator automatically restores to STAT Stack The indicator is not in indicator the stack mode The service interface indicator indicates the stack information After 45 seconds the service interface indicator automatically restores to STAT Blinking green The indicator indicates the active device in a stack ora device not added toa stack Issue 02 2012 09 10 Huawei Proprietary and Confidential 28 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Mode MODE When you press switching the button once button the SPED indicator turns green and the service interface indicators show the speed status of interfaces When you press the button for a second time the STCK indicator turns green and the service interface indicators show the stack status When you press the button for a third time the STAT indicator turns green If you do not press the button within 45 seconds the indicators restore to the default status That is the STAT indicator turns green and the SPED and STCK indicators are off Issue 02 2012 09 10 Huawei Proprietary and Confidential 29 Copyright Huawei Technologies Co Ltd 3700 amp S5700 amp S6700 Series Ethernet Switches 2 Product Hardware Introduction GE electrical interfaces The first ind
54. ype Non PoE S 5700 24TP Take S5700 24TP SI AC for example See Figure 2 5 switch SI AC supporting a single power supply S5700 24TP SI DC S5700 48TP SI AC S5700 48TP SI DC S 5700 28P LI Take S5700 28P LI AC for example See Figure 2 6 AC 5700 28P LI r Q S 5700 52P LI AC S 5700 52P LI S5700S 28P LI AC S5700S 52P LI AC Non PoE S 5700 28C EI Take S5700 28C EI for example See Figure 2 7 switch supporting two power supplies S5700 28C SI 5700 28C EI 24S S 5700 52C EI 5700 52C SI 5700 28C HI 5700 28C HI 24S 5710 28C LI 5710 52C LI S5710 28C EI Take 5710 28C EI for example See Figure 2 8 5710 52C EI Issue 02 2012 09 10 Huawei Proprietary and Confidential 14 Copyright Huawei Technologies Co Ltd S 3700 amp S5700 amp S6700 Series Ethernet Switches Quick Start 2 Product Hardware Introduction Device Model Indicator Type PoE switch S 5700 28C Take S5700 28C PWR EI for example See Figure 2 9 supporting PWR EI two power supplies 5700 52C PWR EI S5700 24TP PWR SI S5700 48TP PWR SI 5700 28C PWR SI S 5700 52C PWR SI 5710 28C PWR LI 5710 52C PWR LI PoE switch S 5700 28P Take S5700 28P PWR LI AC for example See Figure supporting a PWR LI AC 2 10 single power apply 5700 52P PWR LI AC Indicators of a Non PoE 5700 S 5700 24TP SI AC and S5700 28P LI AC are non PoE switches CO note Only

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - LIXIL  MASTERVOLT Powerbook 2015 - Nordwest-Funk  APPENDIX E OPTION 750 Operating Instructions for the Multiple  XorPlus CLI User Guide and Reference Manual  Orlando MY2014  Manuel d`utilisation Séries WV-SFR6 Séries WV - psn  2 - PlayStation  Dell Dimension 5100C (D51CL1) PC Desktop  L-PAK250 ハイバキュームユニット取扱説明書  