Contents
1. POSSIBLE CAUSES SUGGESTION Battery voltage is too low below 10V DC Recharge battery The inverter is overload Reduce load to 150 Watts PINV1 300 Watts PINV2 and 400 Watts PINV3 maximum to maintain regulation SYMPTOM THE LOW BATTERY 15 MEASURED POSSIBLE CAUSES SUGGESTION The poor battery condition Recharge battery Inadequate power of excessive voltage drop Check condition of battery clips and terminals Clean or replace as necessary SPECIFICATIONS AC output voltage 1 2 115 Volts AC DC input voltage 10 15 Volts DC Maximum Continuous AC output power 150 Watts PINV1 300 Watts PINV2 400 Watts PINV3 Maximum AC output Surge nnenesersensensnnnennnnnnnnnennnnnnnn nennen nnnnennnnnnnn 300 Watts PINV1 E E O 600 Watts PINV2 ASAS A EA tl 800 Watts PINV3 AC Output OUEN iniciar noes 60 Hz 2 Hz AG output Waveform modified sine wave No load current draw ns nennen less than 0 3A PINV1 NN less than 0 5A PINV2 O AS less than 0 7A PINV3 MT TT 12 8 20 AMP PINV1 e ets 25 6 40 AMP PINV2 53 0 60 AMP PINV3 Optimum Sic comuna 90 Ambient operating
2. PINV1 300 Watts PINV2 or 400 Watts PINV3 the overload shutdown occurred Use the product with a total power rating less than 150 Watts PINV1 300 Watts PINV2 and 400 Watts PINV3 The connected AC products are rated at less than 150 Watts PINV1 300 Watts PINV2 or 400 Watts PINV3 the high Use the product not exceeds the inverter s surge capacity 300 Watts PINV1 600 starting surge causes the overload shutdown The battery 15 discharged alarm sounds Watts PINV2 and 800 Watts PINV3 Recharge battery The inverter overheated Turn off the inverter and allow to cool for 15 minutes Clear blocked fan PINV2 PINV3 or remove the objects covering the ventilation SYMPTOM B NO AC POWER OUTPUT NO LED LIGHTS ARE ON POSSIBLE CAUSES SUGGESTION The lighter socket or 12 Volt outlet has been poor contacted Press plug into socket firmly The lighter socket or 12 Volt may require ignition to be on Turn key to accessory position The fuse of cigarette lighter or 12 Volt outlet is blown The fuse of inverter is blown Check vehicle fuses and replace Check to make sure the inverter is connected to a power source with correct voltage and polarity Replace fuse The inverter has been connected with reverse DC input polarity The inverter needs repairment if the probable damage has occurred SYMPTOM C THE LOW OUTPUT OF INVERTER IS MEASURED
3. a 12 Volt battery please use the provided battery clip cables PINV2 PINV3 to connect the inverter directly to the 12 Volt power source the PINV1 is not suitable for operating at power requirement are over than 150 Watts While using the battery clip cable of PINV2 PINV3 please follow these steps A Cut the lighter plug off the PINV2 PINV3 power cord B Turn off the power switch and be sure no flammable fumes are present C Connect the BLACK cable to the black post and RED cable to the red post on the rear of the PINV2 PINV3 Then connect the BLACK battery chip to the NEGATIVE terminal and RED battery chip to the POSITIVE terminal of the battery The reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter Do not use the system with positive electrical grounding D Be sure to fasten all connections between battery chips and terminals The LED indicators A GREEN It indicates the inverter is power on the cooling fan PINV2 PINV3 is also activated and power will be delivered to the AC outlet RED It indicates the inverter shutdown caused by low voltage overload or excessive temperature The ON OFF switch It enables output AC power at the AC outlet when switched ON It also acts as a manual reset for overload low battery voltage and overheat fault conditions Reset occurs by switching OFF for 5 seconds after automatic shout down then back ON again Thi
4. Ax2 OPERATION CAUTION DO NOT USE THIS INVERTER WITH THE FOLLOWING e Small battery operated appliances such as RECHARGEABLE FLASHLIGHTS SOME RECHARGEABLE SHAVERS and NIGHT LIGHTS that are plugged directly into as RECEPTACLE TO RECHARGE BATTERY CHARGERS used with certain power tool battery packs These chargers will have a WARNING LABEL stating that DANGEROUS VOLTAGE ARE PRESENT AT THE CHARGERS BATTERY TERMINALS WARNING Batteries contain corrosive materials and present an Energy Hazard To prevent irritation and burns wear protective wear and clothing and take special care to ensure no metal tools or personal objects contact the battery terminals The Power Source Connection The power source must provide between 10 3 to 15 6 Volts DC and must be able to supply the necessary current to operate the load The power source may be a battery or a well regulated 12V 30A DC power supply To obtain the power source must deliver in amperes you can divide the power consumption of the load in watt by 12 the input voltage For example the load is rated at 150 Watts the power source must be able to deliver 150 12 12 5 Amp The inverter is equipped with a heavy duty DC lighter plug that fits standard vehicle cigarette lighter and DC power outlets With this lighter plug the inverter can power loads up to 150 Watts When continuously powering loads rated higher than 150 Watts connect the inverter directly to
5. PYLE PINV2 PINV3 OWNER S MANUAL POWER INVERTER PINV1 150WATT PINV2 300WATT PINV3 400WATT www pyleaudio com INTRODUCTION Thank you for purchasing the PYLE View DC to AC Power Inverter The PINV1 PINV2 PINV3 will deliver an efficient power to a wide variety of household AC products or electronic appliance reliably from the 12 volt outlet in your vehicle or boat or directly from a 12 Volt battery to serve such as most TVs VCRs Play Stations Work Lights Soldering Irons etc Please pay your special attention to all CAUTION and WARNING statements Improper use of this inverter can cause personnel injury property damage and or loss of life WARNING Shock Hazard Keep away from children e The PINV1 PINV2 PINV3 Generates the same potentially lethal AC power as normal household wall outlet Treat it with the same respect that you would do to any AC outlet e The PINVI PINV2 1 is designed for indoor use only and not recommended for use with inductive loads such as florescent lamps compressors amp pumps Ensure to maintain at least 2 inch 5cm air space on all sides of this inverter as its housing may become uncomfortably warm reaching 140 F 60 C under extended high power e Disconnect power to the inverter when it is not in use e Do not expose this inverter to water rain snow or spray e Do not insert foreign objects into this inverter s AC outlets e Do not leave this inverter or any de
6. he charge level of the battery its capacity and the power level drawn by the particular AC load The operating time of two to three hours can be expected with a 100 to 150 Watt load the operating time of 1 hour or more can be expected with a 300 Watt load The vehicle batteries are not intended for constant deep discharge they are designed to provide brief periods of very high current needed for engine starting lt is strongly recommended to start the vehicle every hour or two to recharge battery before its capacity drops too low Operating the inverter from a vehicle battery until the low voltage alarm sounds will shorten the battery s life The inverter can operate whether or not the vehicle s engine is running but the normal voltage drop that occurs during starting may trigger the inverter s low voltage shutdown feature The use of a deep discharge battery is strongly advised for longer operating times Its capacity should be selected based on the desired operating time PROTECTION SYMPTOMS The input reverse polarity The low voltage battery below DC 10V The high input voltage over DC 15 6V The overload The overheat PROTECTION The fuse blown The unit auto shutdown The alarm sounds The RED LED lights The unit auto shutdown The RED LED lights TROUBLE SHOOTING SYMPTOM A NO AC POWER OUTPUT THE RED LED LIGHTS POSSIBLE CAUSES SUGGESTION The connected AC products are rated at more than 150 Watts
7. s manual reset feature prevents unexpected or hazardous restarting of connected AC loads The AC outlet Single and dual AC outlets are provided on one end of the PINV1 PINV2 and PINV3 make sure of the power consumption required before plug in A When operated from a vehicle cigarette lighter PINV1 PINV2 PINV3 A consumption of 150 Watts or less for PINV1 and any combination of 115 Volt AC products with a total power consumption of 150 Watts or less for PINV2 PINV3 B When operated from the directly connection to a 12 Volt battery PINV2 PINV3 Any combination of 115 Volt AC products with a total power consumption of 300 Watts or less for PINV2 PINV3 CAUTION Do not connect AC DISTRIBUTION WIRING The inverter is designed for connection directly to standard electrical and electronic equipment e Do not connect the inverter to household or RV AC distribution wiring Do not connect the inverter to any AC load circuit in which the neutral conductor is connected to ground earth or to the negative of DC battery source The fuse replacement If the inverter is overload and the spade type fuse is blown open the fuse replacement cover at the rear of inverter and replace the blown fuse with a new spade type fuse 20A for PINV1 35A for PINV2 and 30A X 2 for PINV3 Determine the cause of the short circuiting before restarting the inverter BATTERY OPERATING TIME The operating time of battery will vary depending on t
8. temperature 0 C 40 C 32 F 100 F Low battery alarm trigger point 10 5 Volts Low battery shut down point 9 8 10 4 Volts High battery shut down point 15 Volts Number of ac receptacles rsssusnsorneseenasnnusesnsonennennnonnsnonessennnennssennnenneonen 1 PINV1 2 PINV2 2 PINV3 ai 0 62 kgs 1 37 Ibs PINV1 1 02 kgs 2 25 Ibs PINV2 ARANA ARE tn lada 1 30 kgs 2 86 Ibs PINV3 Dimensions W H D 121x53x118 PINV1 A ROO 121x53x170 PINV2 e ad a ak Lo 121x53x214 PINV3 Specifications are typical individual units might vary Specifications are subject to change and improvement without notice 8
9. vice operating unattended to avoid property damage potentially e Do not use or place this inverter near flammable materials or any places which accumulate flammable fumes e Do not connect this inverter to power utility AC distribution wiring under any circumstance Check the input and output connectors of this inverter are tight regularly The loose connections can generate harmful heat and of damage the inverter or power source CAUTION e Do not connect any AC product to this inverter whose neutral conductor is connected to ground e Do not expose this inverter to temperature in excess of 100 F 40 C e This inverter must be connected only to batteries with a normal output voltage of 12 Volts This unit will not operate from a 6 Volt battery and will be damaged if it is connected to a 24 Volt battery FEATURES PINV1 1 AC OUTLET 2 ON OFF SWITCH 3 POWER ON LED 4 PROTECTION LED 5 LIGHTER PLUG PINVI FRONT PANEL a 000000000 5 O O O O O O O 000000006 PINV2 PINV3 1 AC OUTLET 2 ON OFF SWITCH 3 POWER ON LED 4 PROTECTION LED 5 BINDING POST TERMINAL REAR PANEL O 000000 00000000 00000000 900000009 000000 PINV2 REAR PANEL PINV3 REAR PANEL FUSE 30