Home
Dell Wyse X90cw WES7 software
Contents
1. Continue with Installing WES7 Firmware 3 Installing WES7 Firmware This chapter includes the requirements and procedures you need to install and use Wyse USB Firmware ToolTM to update your mobile thin client to WES7 firmware Requirements Windows XP Professional SP3 or Windows 2003 Server USB key size should be 4 GB or larger up to 16 GB tested see USB Keys Troubleshooting Boot Issues Procedures Step 1 Copy the X Class WES7 Conversion Image Folder to Your Local Hard Drive Navigate to the X Class WES7 Conversion Image folder contained on the Conversion Software Assembly DVD ROM and copy it to your local hard drive Step 2 Install Wyse USB Firmware Tool 1 10 1 Navigate to the Wyse USB Firmware Tool v1 10_GA exe contained on the Conversion Software Assembly DVD ROM and double click it to execute the file and open the WinZip Self Extractor dialog box Figure 6 Extract files to your hard drive C USBFT110 2 Enter C USBFT110 in the Unzip to folder box and then click Unzip to extract all files from the Wyse USB Firmware Tool v1 10_GA exe file into the C USBFT110 directory The default directory for the extracted files is Wyse USB Firmware Tool Caution It is not recommended to use your desktop for the destination directory as there are several files that will be extracted from the exe file 3 Create a shortcut on the desktop for the Wyse USB Firmware Tool exe file 8 Chapter 3 Step 3 Us
2. 1 800 800 9973 option 1 or 1 408 473 1200 option 1 Installing WES7 Firmware 13 Troubleshooting This section contains general troubleshooting information USB Keys Troubleshooting Boot Issues Due to different manufacturing processes on USB keys and the variety of them not all brands have been tested with the Wyse USB Firmware Tool If you experience problems booting from a configured USB key it is recommended that you try a different brand of USB key The following list of USB keys have been successfully tested with the Wyse USB Firmware Tool Kingston Data Traveler 4 GB Kingston Data Traveler 8 GB SanDisk Cruzer micro 4 GB SanDisk Cruzer micro 8 GB SanDisk Cruzer micro 16 GB Transcendent 4GB SanDisk Cruiser Flash Drives Troubleshooting Partition Issues Problem How can I properly use a SanDisk Cruiser flash drive to image supported devices using the Wyse USB Firmware Tool KB17735 Solution SanDisk flash drives come with support for U3 for details on U3 see http www u3 com When you initially use these drives you are prompted to select the use for the drive Apps and Storage or only Storage If you select the Apps and Storage option the drive will create two partitions one of which is identified as a CD and is a read only partition This partition sometimes prevents the Wyse USB Firmware Tool to properly prepare the USB key for imaging a device To resolve this problem you
3. 5 9 Remove the screw from the RAM cover using a small Phillips Screwdriver as shown in Figure 4 Figure 4 Removing the RAM cover screw 10 Lift the RAM cover to remove it and expose the RAM module as shown in Figure 5 Notice that the front of mobile the thin client is positioned at the bottom of the photo Warning RAM modules may be susceptible to damage by Electro Static Discharge ESD All industry standard cautions should be followed to avoid ESD Before you remove or install a module touch any metal part of the chassis and keep that contact with the chassis during the installation process 11 Remove the existing RAM module Use your fingers to unlock the two retaining clips at either side of the RAM module by pushing in the direction of the arrows shown in Figure 5 The module should pop up from its socket Lift out the RAM module Figure 5 Removing the existing RAM module 6 Chapter 2 12 Install the new RAM module in the reverse order of removing the original RAM module Carefully press down on the RAM module until its retaining clips lock it into place 13 Replace the RAM cover in the reverse order as described in steps 10 and 9 Caution Do not turn on the mobile thin client The mobile thin client is ready to re image however the flash module does not contain an operating system Turning on power to your mobile thin client without firmware will display the error message NO OPERATING SYSTEM FOUND What s Next
4. Installation Guide Wyse X Class Conversion to WES7 Wyse USB Firmware ToolTM Release 1 10 Issue 102910 PN 883887 19L Rev B Copyright Notices 2010 Wyse Technology Inc All rights reserved This manual and the software and firmware described in it are copyrighted You may not reproduce transmit transcribe store in a retrieval system or translate into any language or computer language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise any part of this publication without express written permission End User License Agreement License A copy of the Wyse Technology End User License Agreement is included in the software and provided for your reference only The License at http www wyse com license as of the purchase date is the controlling licensing agreement By copying using or installing the software or the product you agree to be bound by those terms Trademarks The Wyse logo and Wyse are trademarks of Wyse Technology Inc Other product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies Specifications subject to change without notice Restricted Rights Legend You acknowledge that the Software is of U S origin You agree to comply with all applicable international and national laws that apply to the Software including the U S Export Administration Regulations as w
5. can do one of the following Go to http www sandisk com search in the SanDisk Knowledge Base for document 2550 and then follow the instructions in the documentation Go to http www sandisk com DriverDownload driverList asp select USB Flash Drives from the Select Product Type list click Find Driver select U3 LaunchPad Remover click Continue and then download and use the U3 Launchpad Remover according to the instructions Installation Guide Wyse X Class Conversion to WES7 Issue 102910 Written and published by Wyse Technology Inc October 2010 Created using FrameMaker and Acrobat
6. e Conversion Labels you must attach a Wyse label to each converted mobile thin client Microsoft License Labels you must attach a COA label to each converted mobile thin client Figure 1 Kit contents items may look different or not be included in your kit 2 Chapter 1 The Conversion Software Assembly DVD ROM contains A PDF of this Reference Guide Wyse USB Firmware Tool Release 1 10 X Class WES7 Conversion Image folder containing the following files bios img cmos img commandsXml xml CRC Txt initrd pxe mbr img par1 img vmlinuz Overview To convert your X class mobile thin clients to WES7 1 Optional If you need to perform a hardware installation install new flash and RAM complete Installing X90cw Mobile Thin Client Flash and RAM 2 Required Complete Installing WES7 Firmware Wyse Technical Support To access Wyse technical resources visit http www wyse com support If you still have questions you can submit your questions using the Wyse Self Service Center on the Wyse com home page go to Support gt Knowledge Base gt Home tab or call Customer Support at 1 800 800 WYSE toll free in U S and Canada Hours of operation are from 6 00 A M to 5 00 P M Pacific Time Monday through Friday To access international support visit http www wyse com global Related Documentation and Services Fact Sheets containing the features
7. e Wyse USB Firmware Tool to Configure a Single USB Key to Install Firmware 1 Double click the shortcut to run the tool and open the Wyse USB Firmware Tool wizard the welcome page provides the product version and description and a link to view the Wyse end user license agreement Figure 7 Wyse USB Firmware Tool wizard 2 Click Next to open the Select an Option dialog box Figure 8 Configuration options 3 Select the Configure a single USB key to Copy or Update firmware option and then click Next to open the Select the Configuration dialog box Figure 9 Update firmware options Installing WES7 Firmware 9 4 Select the Windows Embedded Standard 7 OS type option 5 Select the Update Firmware operation to perform option Tip Although the Preserve data partition check box is automatically selected to preserve any existing data partition you can clear the check box if you want to remove the existing data in the data partition 6 Select all three contents options OS Image BIOS and CMOS 7 Click Next to open the browse dialog box Figure 10 Browse for image file 8 Click Browse Figure 11 Browse to select commandsXml xml 9 Navigate to the X Class WES7 Conversion Image folder on your hard drive this is the location you selected in Step 1 Copy the X Class WES7 Conversion Image Folder to Your Local Hard Drive click on the commandsXml xml file to select it and then click Open Caution Do not use the com
8. ell as end user end use and country destination restrictions issued by U S and other governments For additional information on exporting the Software see http www microsoft com exporting Ordering Information For availability pricing and ordering information in the United States and Canada call 1 800 GET WYSE 1 800 438 9973 or visit us at http www wyse com In all other countries contact your sales representative Contents 1 Introduction 1 Kit Contents 1 Overview 2 Wyse Technical Support 2 Related Documentation and Services 2 Wyse Online Community 2 2 Installing X90cw Mobile Thin Client Flash and RAM 3 Requirements 3 Procedures 3 What s Next 6 3 Installing WES7 Firmware 7 Requirements 7 Procedures 7 Troubleshooting 13 USB Keys Troubleshooting Boot Issues 13 SanDisk Cruiser Flash Drives Troubleshooting Partition Issues 13 iv Contents This page intentionally blank 1 Introduction This guide provides step by step instructions to convert X90cw mobile thin clients from WES2009 to WES7 Caution WES7 firmware requires X class mobile thin clients to have a minimum of 4 GB flash and 2 GB RAM Tip After converting your mobile thin clients obtain any available firmware update at http www wyse com serviceandsupport support downloads asp Kit Contents The conversion kit can include Conversion Software Assembly DVD ROM Flash module RAM module Wys
9. mandsXml xml file directly from the Conversion Software Assembly DVD ROM 10 In the browse dialog box click Next to open the Prepare the USB Drive dialog box 10 Chapter 3 Figure 12 Prepare USB drive 11 Select the USB key onto which you want the configurations you can use Refresh as needed to recognize an inserted USB key and then click Next The progress bars show the overall progress and task progress 12 After configuration click Finish to close the wizard and then remove the configured USB key for use you will use the configured USB key on your target devices Caution Before using any configured USB key on a target device to push firmware you must configure the target device to boot from the configured USB key as described in Step 4 Use the Configured USB Key to Install Firmware on Each Mobile Thin Client Step 4 Use the Configured USB Key to Install Firmware on Each Mobile Thin Client On each mobile thin client you want to convert you must enter and change the BIOS Setup Utility Attach the configured USB key to the mobile client be sure it is shut down During boot press and hold the F2 key Enter the password Fireport this is case sensitive and press Enter Select the Boot option and press Enter Select the Legacy option and press Enter Select the Normal Boot Menu option and press Enter Select the option displaying your USB key vendor name and move it to the 1 position by using the key Save the BIOS setti
10. ngs and reboot Follow the process prompts Caution There is no one time boot menu If needed you can return your default BIOS configurations after completing your mobile thin client conversions Tip When booting a target device from the configured USB key containing the contents to be pushed to a target device you will be prompted to continue with the push process to continue type y and press Enter Once the push process is complete you will be prompted to reboot to reboot press Enter and remove the USB key Installing WES7 Firmware 11 Step 5 Verifying Mobile Thin Client Operation After the mobile thin client reboots you can verify the Version and that your general client information is correct Figure 13 Client Information blank example 1 On the General tab of the Client Information window Start gt All Programs gt Wyse Client Information verify the following Version is 9 01 Build 0806 2 Click OK to close the Client Information window The mobile thin client is ready for operation and setup by an administrator Tip For security automatic logon to a User desktop is enabled on the mobile thin client by default and is a member of the User group not a member of the Administrator group To log on as a different user or an administrator Use the Log off button Start gt Log off to log off the current desktop while holding down the SHIFT key until the Log On window displays Log on as follows pas
11. of hardware models are available on the Wyse Web site Go to http www wyse com products click the Thin Computing Hardware link click the link for your hardware model and then click the link for the Fact Sheet Administrator and other documentation for your thin client model are available at http www wyse com manuals Wyse Online Community Wyse maintains an online community where users of our products can seek and exchange information on user forums Visit the Wyse Online Community forums at http community wyse com forum 2 Installing X90cw Mobile Thin Client Flash and RAM This chapter contains information for users of Wyse X90cw mobile thin clients who must install new flash and RAM If you are installing firmware only you can skip this chapter and proceed to Installing WES7 Firmware Requirements Small Phillips screwdriver Optional Container for holding screws Warning Flash and RAM modules may be susceptible to damage by Electro Static Discharge ESD All industry standard cautions should be followed to avoid ESD Before you remove or install a module touch any metal part of the chassis and keep that contact with the chassis during the installation process Procedures Caution Follow all precautions listed in the Quick Start Guide that came with your mobile thin client for disconnecting and reconnecting the mobile thin client 1 Perform a proper shutdown of the mobile thin client by closing all file
12. s and ending your session and then pressing the power button to turn off the mobile thin client 2 Unplug the power cord and power adapter and remove any other cables from the mobile thin client 3 Position the mobile thin client to access the bottom flash and RAM covers 4 Remove the screws from the flash cover using a small Phillips screwdriver as shown in Figure 2 4 Chapter 2 Figure 2 Removing the flash cover screws 5 Lift the flash cover to remove it and expose the flash module as shown in Figure 3 Notice that the front of mobile the thin client is positioned at the bottom of the photo Warning Flash modules may be susceptible to damage by Electro Static Discharge ESD All industry standard cautions should be followed to avoid ESD Before you remove or install a module touch any metal part of the chassis and keep that contact with the chassis during the installation process 6 Remove the existing flash module Locate the flash module and push its retaining clip out of the way in the direction of the arrow shown in Figure 3 Lift the flash module out of the socket Figure 3 Removing the existing flash module 7 Install the new flash module in the reverse order of removing the original flash module Carefully press down on the flash module until its retaining clip locks it into place 8 Replace the flash cover in the reverse order as described in steps 5 and 4 Installing X90cw Mobile Thin Client Flash and RAM
13. swords are case sensitive Administrators default Username is administrator and default Password is Wyse 123 Users default Username is user and default Password is Wyse 123 Administrator and other documentation for your mobile thin client model are available at http www wyse com manuals 12 Chapter 3 Step 6 Attach a Wyse Conversion Label and Microsoft License Label on Each Converted Mobile Thin Client The conversion kit is supplied with Wyse Conversion Labels and Microsoft License Labels that must be attached to each mobile thin client as shown in Figures 14 and 15 Be sure you have purchased the amount of labels you need Caution Failure to install the labels may cause delays in service and support The serial number must be given to a Customer Support Technician to validate entitlement to support and service from Wyse Failure to do so will result in the original operating system being loaded on the device and is in breach of your license agreement Figure 14 Placement of Wyse label on the X90cw Figure 15 Placement of COA label on the X90cw Step 7 Obtain a Firmware Update After converting your mobile thin clients obtain any available firmware update at http www wyse com serviceandsupport support downloads asp Warning Use of the Software on more than one device requires that you first purchase from Wyse additional copies of or licenses to the Software Contact your local Wyse distributor or Wyse Inside Sales at