1. m Humidity 0 to 85 AC DC Power Adapter O Power Input AC 100 240V 50 60Hz 0 1A O Power Output 5 V 1 0A SMPS DC power Adapter O Cord DC Jack Core is 5V and outer is GND 1 6 Product Specifications Warranty Information 1 One Year Warranty Opticis warrants this optical DP extension cable to be free from defects in workmanship and materials under normal use and service for a period of one 1 year from the date of purchase from Opticis or its authorized resellers If a product does not work as warranted during the applicable warranty period Opticis shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of Opticis Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the reminder of the initial warranty period whichever is longer Opticis shall not be responsible for any software firmware information or memory data of customer contained in stored on or integrated with any products returned to Opticis for repair under warranty or not Warranty Limitation and Exclusion Opticis shall have no further obligation under the foregoing limited warranty if the product has been damaged due to abuse misuse neglect accident unusu
2. Monitors to be connected m No special requirements of memory size CPU speed and chipsets if you ve already properly installed your DP systems or DP graphic cards O Software requirements m No special restrictions if you ve already properly installed your DP systems O AC DC Power Adapter Technical Advisory The M1 5000 is designed to use only 5V external power To plug the power either Tx module or Rx module makes each modules supplied over a copper wire of the hybrid cable 1 2 System Requirements for Setup Installation Important Please use the installation procedure below Improper or no operation may result if the start up sequence is not correctly followed Step 1 Carefully unpack the contents of the shipping group Step 2 Plug directly the DP plug of the Tx side of M1 5000 into the DP receptacle of DP source PC or Graphic Source Do NOT recommend to use any intermediate cable or adapter between them It may deteriorate the signal transmission performance he Tx of M1 5000 lt 5 DP input q PC Figure 2 Tx Module of M1 5000 Cable Step 3 As shown in Figure 3 plug the 5V power adaptor in the shipping group to the Tx module or Rx Module Connecting 5V power adaptor to M1 5000 Cable is indispensable procedure for working DP Input ON pe O Figure 3 Tx Module of M1 5000 Cable with power adapter 1 3 Installation Step 4 Plug the DP plug of the Rx side of M1 5000 int
3. amp pric s Stretch DisplayPort User s Manual M1 5000 Manual Contents Manual Contents VVelcomel Product Description System Requirements for Setup Installation Troubleshooting Maintenance Technical Support Product Specifications Warranty Information Regulatory Statements Pictorials Figure 1 Optical DisplayPort Extension Cable M1 5000 Figure 2 Tx Module of M1 5000 Cable Figure 3 Tx Module of M1 5000 Cable with adapter Figure 4 Rx Module of M1 5000 Cable Frgure5 Whole Connection of M1 5000 Cable 1 0 Manual Contents b ii QO O1 O VVelcomel Congratulations on your purchase of the Stretch DisplayPort M1 5000 Optical DisplayPort Extension Cable This manual contains information that will assist you in installing and operating the product Product Description Shipping Group O M1 5000 Optical DisplayPort Cable One 1 unit length as your request DisplayPort Copper Cable Two 2 units 0 5M O 5V AC DC power adapter One 1 unit Users Manual Up to 100m with auxilliary signals DP Input PC Display Figure 1 Optical DP extension Cable M1 5000 1 1 Welcome Product Description System Reguiremenis for Setup O Hardware requirements m You have to have a DisplayPort multimedia systems PC DVD AV Receiver STB Displaying Monitor etc or graphic cards It should support the maximum graphic resolution feature of
4. protection against ingress of water as detailed in the current edition of IEC 529 IPXO ordinary equipment e This equipment is not suitable for use in the presence of flammable anesthetics or oxygen Mode of operation continuous operation Certification of Eye Safety This laser product is inside implemented by using 1300 1550nm optical module manufactured by Opticis Co Ltd which are all certified by IEC EN60825 1 referred in Accession Number 07 1334 0217 as classified in Laser Class1 1 9 Regulatory Statements 2009 Opticis Co Ltd All Rights Reserved Revision 1 1 Jul 06 2011 Opticis Locations Headquarters Opticis Co Ltd 304 Byucksan Technopia 434 6 Sangdaewon Dong Chungwon Ku Sungnam City Kyungki Do 462 716 South Korea Tel 82 31 737 8033 8 Fax 82 31 737 8079 www opticis com For order support please contact your Distributor or Reseller For technical support check with the Opticis web site www opticis com or contact techsupp opticis com
5. al physical or electrical stress unauthorized modifications tampering alterations or service other than by Opticis or its authorized agents causes other than from ordinary use or failure to properly use the Product in the application for which said Product is intended Dispose of Old Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate systems This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative a consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product 1 7 Warranty Information FCC CE Statement This device complies with part 15 of FCC Rules and EN 55022 55024 61000 3 for CE certification Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that
6. may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 and 2 of FCC Rules and EN 55022 55024 61000 3 for CE certification These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction guide may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult a service representative for help Properly shielded and grounded cables and connectors must be used in order to comply with FCC CE emission limits Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment UL Statement This device has c
7. o the DP receptacle of a Display Do NOT recommend to use any intermediate cable or adapter between them It may deteriorate the signal transmission performance Rx of M1 5000 DP Output Display Figure 4 Rx Module of M1 5000 Cable Step 5 Power ON the device of a DP source and a Monitor Note M1 5000 must be connected by 5V power adaptor To plug it into Tx module makes the Rx module supplied over a copper wire in the hybrid cable Up to 100m with auxilliary signals Be Ta P DP Output A Display DP Input b a PC Figure 5 Whole Connection of M1 5000 Cable Step 7 If the system does not work properly go to page 1 5 trouble shooting 1 4 Installation continued Troubleshooting The display shows oniy black screen Ensure that all AC and DC plugs and jacks used by external power supplies both Opticis and others are firmly connected Ensure that power bars are live Ensure that the DP ports are firmly plugged in to the DP source PC and Monitor TV Ensure that the Tx and Rx module parts plug correctly to the DP source PC and Monitor respectively Check if the DP source PC and Monitor are powered on and properly booted Reset the system by de plugging and re plugging the Tx DP port or Rx DP port or by de plugging and re plugging the power cord plugs of Tx module Re boot up the system while connecting the optical DP cable system Screen is distorted or displays noises Ensure connecti
8. ompleted a UL Commercial Inspection and Testing Services for the multimode DVI cable complied with VW 1 under UL 758 It is validated by the UL file number SV2038 and project number 04CA05353 1 8 Regulatory Statements UL IEC Statement This equipment has been tested and found to comply with the limits for medical devices in IEC 60601 1 1994 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to other devices which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving device Increase the separation between the equipment Connect the equipment into an outlet on a circuit different from that to which the other device s are connected Consult the manufacturer or field service technician for help Type of protection against electric shock Class equipment Degree of protection against electric shock Not classified no applied parts e Classification according to the degree of
9. ons of both plugs while disconnecting and reconnecting the optical DP cables or DC power adapters Maintenance No special maintenance is required for the optical DP cables and power supplies Ensure that the cables and power modules are stored or used in a benign environment free from liquid or dirt contamination There are no user serviceable parts Refer all service and repair issues to Opticis Technical Support and Service For commercial or general product support contact your reseller For technical service contact Opticis by email techsupp opticis com or visit its website at www opticis com 1 5 Troubleshooting Maintenance Technical Support Product Specifications M1 5000 Optical DP Extension Cable Compliance with DisplayPort standard support DP 1 1 with 36 bit color depth and DVI 1 0 DDC2B fully implemented by fiber optic communication O Extension limit 100m 330feet for WQXGA 2560x1600 at 60 Hz refresh rate O Graphic Transmission Bandwidth Support 2 7Gbps per one lane O Hybrid Fiber optic Cable Flame retardant PVC employing 4 fiber strands and 5 shielded copper wires O Tensile load 180N m Minimum bend radius 15 4cm m Outer diameter of cable 7 2mm O Mechanical specifications of Tx and Rx module parts m Dimensions 35mm 16mm 99 4mm W H D m Clamping strength to cable 14kg O Environmental Specifications m Operating temperature 0 C to 50 C Storage temperature 30 C to 70 C