Home

APC SBP20KP uninterruptible power supply (UPS)

image

Contents

1. Industries S A S American Power Conversion Corporation or their affiliated companies All other trademarks are property of their respective owners SBP20K Series User Manual 11
2. registered the product The product may be registered at the APC Web site www apc com 10 SBP20K Series User Manual Exclusions APC shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user s or any third person s misuse negligence improper installation or testing Further APC shall not be liable under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical voltage or connection inappropriate on site operation conditions corrosive atmosphere repair installation exposure to the elements Acts of God fire theft or installation contrary to APC recommendations or specifications or in any event if the APC serial number has been altered defaced or removed or any other cause beyond the range of the intended use THERE ARE NO WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE OF PRODUCTS SOLD SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH APC DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE APC EXPRESS WARRANTIES WILL NOT BE ENLARGED DIMINISHED OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF APC RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES THE WARRANTIES S
3. www apc com Este manual e o guia de seguran a est o dispon veis em portugu s no CD incluso e no website da APC www apc com Instrukcja obs ugi oraz przewodnik bezpiecze stwa w j zyku polskim dost pne s na za czonej p ycie CD i na stronie internetowej APC www apc com Denna manual och sakerhetsguide finns tillg nglig pa svenska pa medf ljande CD och pa APC s webbsida www apc com Bu k lavuzun ve g venlik k lavuzunun T rk e versiyonu r nle birlikte verilen CD de ve www apc com adresindeki APC web sitesinde bulunmaktad r Panduan dan petunjuk keselamatan ini tersedia dalam Bahasa Inggris pada CD terlampir dan pada Situs APC www apc com AREROBREAA FORRA AAD CD RU APCO Web 14 b www apc com 225 OC BakIt ET D WHAD OA DOSE SSF CD 2 APC LAOLE www apc com HA tee 08 s Usce AHTOA3bIUHBIM BapHaHT TaHHOrO PyKOBOACTBAa H PyKOBOCTBa DO TeXHHKe Oe30MacHOCTH HMEETCA Ha MpHNATACMOM KOMIIAKT J CK a Take Ha calite KoMMaHHH APC www apc com De i Souen mun 0 nlaee ie uerg leg hunge anna lA waanldauacviulaiaes APC www apc com FEAT DAGEBSETAS CD S APC Hanhi Cwww apc com EIS EIDEL OCI CH AE To eyye p io avt vm o o ny c Oo sivat Ggt ouug OTA EAANVIKG oto CD zou Som gier Kat om LOTODEAIOE TNS APC www apc com Overview The APC by Schneider Electric service bypass panel SBP provide
4. ET FORTH ABOVE CONSTITUTE APC S SOLE LIABILITY AND PURCHASER S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES APC WARRANTIES EXTEND ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES IN NO EVENT SHALL APC ITS OFFICERS DIRECTORS AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT SPECIAL CONSEQUENTIAL OR PUNITIVE DAMAGES ARISING OUT OF THE USE SERVICE OR INSTALLATION OF THE PRODUCTS WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT IRRESPECTIVE OF FAULT NEGLIGENCE OR STRICT LIABILITY OR WHETHER APC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES SPECIFICALLY APC IS NOT LIABLE FOR ANY COSTS SUCH AS LOST PROFITS OR REVENUE LOSS OF EQUIPMENT LOSS OF USE OF EQUIPMENT LOSS OF SOFTWARE LOSS OF DATA COSTS OF SUBSTITUENTS CLAIMS BY THIRD PARTIES OR OTHERWISE NO SALESMAN EMPLOYEE OR AGENT OF APC IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY WARRANTY TERMS MAY BE MODIFIED IF AT ALL ONLY IN WRITING SIGNED BY AN APC OFFICER AND LEGAL DEPARTMENT Warranty claims Customers with warranty claims issues may access the APC customer support network through the Support page of the APC Web site www apc com support Select your country from the country selection pull down menu at the top of the Web page Select the Support tab to obtain contact information for customer support in your region 2010 APC by Schneider Electric APC the APC logo and Smart UPS are owned by Schneider Electric
5. by Schneider Electric e Installation and ce Operation Service Bypass Panel SBP20KP SBP20KRMT4U SBP20KRMI4U V LZ This manual and the safety guide are available in English on the enclosed CD and the APC Web site www apc com U ivatelsk p ru ka a bezpe nostn pokyny jsou k dispozici v e tin na p ilo en m CD a na webov ch str nk ch APC www apc com Denne vejledning og sikkerhedsvejledningen er tilg ngelige pa dansk pa den vedlagte CD og p APC s websted www apc com Dieses Handbuch sowie die Sicherheitsrichtlinien sind in deutscher Sprache auf der beiliegenden CD und auf der Website von APC unter www apc com verf gbar Este manual y la gu a de seguridad est n disponibles en espa ol en el CD adjunto y en el sitio Web de APC www apc com Ce manuel et le guide de s curit sont disponibles en fran ais sur le CD ROM ci inclus et sur le site Web d APC www apc com A haszn lati utas t s s a biztons gi tmutat megtal lhat magyarul a csatolt CD n s az APC honlapj n www apc com Il presente manuale e la corrispondente Guida per la sicurezza sono disponibili in italiano sul CD ROM allegato e sul sito Web di APC all indirizzo www apc com Deze handleiding en het veiligheidshandboek staan in het Nederlands op de bijgevoegde cd en op de APC website www apc com En norsk versjon av denne h ndboken og sikkerhetsveiledningen finnes p den vedlagte CD en og p APCs webomr de
6. g eight ornamental screws supplied four in each bracket Secure the SBP to the wall Select screws not supplied that are appropriate for the weight of the unit and the mounting surface material o E E e 6 E a SBP20K Series User Manual Hardwire the SBP Hardwiring must be performed by a qualified electrician Adhere to all national and local electrical codes Switch the utility circuit breaker off Remove the terminal block access panel located on top of the unit suo0702a On all models remove the access panel with three knockout pieces Remove all three knockout pieces from the panel u00703a Model SBP20KP has two access panels Remove both p of the access panels SE ee Remove all three knockout pieces from the small panel Remove one of the knockout pieces from the large panel suo0704a Strip 24 mm 1 inch of insulation from the cable ends 24mm 1 inch rech EE Insert cables through the holes in the access panel s Connect the ground terminal first All Models SBP20KP Install an appropriate strain relief not supplied on each cable suo0705a suo0706a Secure the cables in the terminal blocks Refer to the terminal block configurations on the following page Use the Allen wrench supplied to tighten the terminal block screws Torque terminals to 6 Nm 53 in lb minimum 8 Nm 71 in lb maximum Replace the access panel s using al
7. hone 888 272 2782 or by e mail Local country specific centers go to Www apc com support contact for contact information For information on how to obtain local customer support contact the APC representative or other distributors from whom you purchased your APC product SBP20K Series User Manual Service If the unit requires service do not return it to the dealer Follow these steps 1 Review the Troubleshooting section of the manual to eliminate common problems 2 Ifthe problem persists contact APC Customer Support through the APC Web site www apc com a Note the model number and serial number and the date of purchase The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models b Call APC Customer Support and a technician will attempt to solve the problem over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA c If the unit is under warranty the repairs are free d Service procedures and returns may vary internationally Refer to the APC Web site for country specific instructions 3 Pack the unit in its original packaging If this is not available refer to www apc com to obtain a new set a Pack the unit properly to avoid damage in transit Never use foam beads for packaging Damage sustained in transit is not covered under warranty b For the UPS always DISCONNECT THE BATTERY before ship
8. l of the screws removed in the previous steps Failure to do so may result in personal injury or equipment damage 6 SBP20K Series User Manual SBP20KRMI4U SBP20KRMT4U UPS AC LINE OUTPUT INPUT AC LINE INPUT UPS AC LINE OUTPUT INPUT Hardwire the UPS Refer to the UPS user manual for detailed instructions SBP20K Series User Manual Operation Normal mode While the SBP operates in normal mode power is supplied to connected equipment from the UPS providing protection from power variations and disturbances Test mode 1 Switch the UPS to Bypass mode Verify that no UPS fault conditions exist In the event that a fault condition exists refer to the user manuals for the UPS and SBP 2 Switch the SBP to Test mode Note While the SBP is in Test mode connected equipment receives direct utility power and is Q not protected by the UPS The UPS will continue to receive input utility power The Equipment Protection Policy is not valid while the SBP is operating in Test mode Bypass mode Bypass mode enables connected equipment to operate on utility power while UPS maintenance is performed While in SBP Bypass mode the UPS will not receive utility input power The UPS will receive battery power while in SBP Bypass mode Refer to the UPS user manual for shutdown procedures Note Connected equipment is not protected by the UPS while the SBP is in By
9. ngs of the SBP and not those of the UPS maximum wire size of 50 mm Refer to the UPS user manual for UPS wiring specifications SBP ratings must be equal to or greater than those of the UPS to which it is connected The input circuit breaker should not exceed the rating recommended on the UPS The system load must not exceed the electrical rating of the UPS For example if a 3840 VA SBP is used with a 3000 VA UPS the maximum load that the system will support is 3000 VA Environmental Specifications Operating 0 to 40 C 32 to 104 F This unit is intended for indoor use only Temperature l Storage 15 to 45 C 40 to 113 F Do not operate the service bypass panel where there is excessive dust or the temperature or Maximum Operating 3 000 m 10 000 ft humidity are outside specified limits EH Storage 15 000 m 50 000 ft Be sure the air vents on the SBP are not Humidity 0 to 95 relative humidity non condensing blocked Allow adequate space for proper ventilation Changes and modifications to this unit not expressly approved by APC could void the warranty 2 SBP20K Series User Manual Front panel by Schneider Electric Service Bypass Panel D Normal gt E zm vm d em pm Bypass Load protected D I Z OON I Ac put CD Il Oe Inpu Load not protected Bypass Load not protected 3 suo0641a Rear panels Callout Description 1 Equipment outlets 2 Equipment outlet circui
10. pass mode The Equipment Protection Policy is not valid while the SBP is operating in Bypass mode Reconnect SBP to UPS Bypass mode 1 Put the SBP in Bypass mode 2 Correctly configure the input output and battery connections on the UPS DO NOT turn on the UPS at this time Test mode 1 Switch the SBP to Test mode a The connected equipment will receive direct input utility power b The UPS will receive input utility power 2 Verify that no UPS fault conditions exist In the event that a fault condition exists refer to the user manuals for the UPS and SBP 3 Turn on the UPS output power Normal mode 1 Switch the UPS to Bypass mode Verify that no UPS fault conditions exist In the event that a fault condition exists refer to the user manuals for the UPS and SBP 2 Switch the SBP to Normal mode 3 Switch the UPS to Online mode Verify that no UPS fault conditions exist In the event that a fault condition exists refer to the user manuals for the UPS and SBP The SBP will now supply power to connected equipment from the UPS providing protection from power variations and disturbances 8 SBP20K Series User Manual Troubleshooting Use the table to solve minor installation and operation problems Refer to the APC Web site www apc com for assistance with complex problems Problem and or Possible Cause Solution UPS will not turn on SBP is in Bypass mode Rotate the SBP switch to TEST There is no power at
11. ping in compliance with U S Department of Transportation DOT and IATA regulations The battery may remain in the unit c Internal batteries may remain connected in the XLBP during shipment if applicable not all units have XLBPs 4 Write the RMA provided by Customer Support on the outside of the package 5 Return the unit by insured pre paid carrier to the address provided by Customer Support Transport the unit Shut down and disconnect all connected equipment Disconnect the unit from utility power Disconnect all internal and external batteries if applicable PP ON Follow the shipping instructions outlined in the Service section of this manual Two Year Factory Warranty This warranty applies only to the products you purchase for your use in accordance with this manual Terms of warranty APC warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase APC will repair or replace defective products covered by this warranty This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way Repair or replacement of a defective product or part thereof does not extend the original warranty period Any parts furnished under this warranty may be new or factory remanufactured Non transferable warranty This warranty extends only to the original purchaser who must have properly
12. s utility power to connected equipment during UPS maintenance Inventory Read the Safety Guide before installing the UPS Inspect the SBP upon receipt Notify the carrier and dealer if there is damage The package is recyclable save it for reuse or dispose of it properly Literature Kit e Product documentation K E e Safety Guide e Warranty card A e Allen wrench Pe Rail Kit Installation Kit Installation Kit Contents ep yD OP D 8 8 8 2 1 pair 1 pair 1 pair 1 pair SBP20K Series User Manual Specifications Electrical Specifications Output Power Input Current Watts VA SBP model Rated Input Voltage Rated Output Voltage maximum maximum 200 208 240 VAC 200 208 240 VAC 125A 30 000 50 60 Hz 2P PE 50 60 Hz 2P PE each phase 220 230 240 VAC 220 230 240 VAC 125 A SERCE 50 60 Hz 1P N PE 50 60 Hz 1P N PE each phase ENER 380 400 415 VAC 220 230 240 VAC 125A 30 000 50 60 Hz 3P N PE 50 60 Hz 1P N PE each phase i 200 208 240 VAC 200 208 240 VAC 125 A SBP20KRMT4U 50 60 Hz 2P PE 50 60 Hz 2P PE each phase 30 009 220 230 240 VAC 220 230 240 VAC 125 A 30 000 50 60 Hz 1P N PE 50 60 Hz 1P N PE each phase 2 SBP20KRMI4U 380 400 415 VAC 220 230 240 VAC 125A 30 000 50 60 Hz 3P N PE 50 60 Hz 1P N PE each phase UPS wire specifications may vary The SBP requires a minimum wire size of 25 mm and a Q Note The table above represents the electrical rati
13. t breakers Utility input power hardwire access al Output power hardwire access SBP20KRMI4U SBP20KRMT4U suo0686a suo0687a SBP20KP Q O o O5 suo0688a SBP20K Series User Manual Installation Stack configuration Always place the SBP above the external battery packs and the UPS Four ornamental screws supplied must be used to secure each tie bracket to the units see diagram suo0689a Rack mount configuration Install rails in rack For details on rail installation refer to the instructions included in the rail kit Install rack mount brackets Secure the brackets to the unit using eight flat head screws supplied Install cleats Secure the cleats to the unit using eight Pan head screws supplied suo0696a Install in rack Always place the SBP above the external battery packs and the UPS A cage nut and an ornamental screw supplied must be used in the top hole of each rack mount bracket when securing the unit in the rack The bottom hole of each rack mount bracket must be secured using an ornamental screw supplied in the threaded hole suo0691a 4 SBP20K Series User Manual Wall mount configuration Secure the wall mount brackets to the unit usin
14. the UPS input Verify that the power cables from the SBP to the utility power and from the SBP to the UPS input are securely connected UPS is faulty or damaged Rotate the SBP switch to Test If the connected equipment is energized the UPS may be faulty Refer to Troubleshooting in the UPS user manual for detailed information There is no power at the utility power outlet Rotate the SBP switch to Test If the connected equipment does not become energized the utility power outlet may be faulty Verify the utility power supply Contact a qualified electrician to check the building electrical power UPS is Online not providing power to connected equipment SBP output circuit breaker has tripped Disconnect all nonessential equipment from the SBP Reset the SBP circuit breaker There is no SBP output power Verify that the power cable from the SBP to the UPS output is securely connected Contact information Customer support for this or any other APC product is available at no charge in any of the following ways Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information Wwww apc com support Global support searching APC Knowledge Base and using e supportt e Contact the APC Customer Support Center by telep

Download Pdf Manuals

image

Related Search

Related Contents

  GE PROFILE FCM15SP User's Manual  Ref. 4801 Ref. 4802 Ref. 4804 Ref. 4881* Ref. 4808 Ref. 4809 Ref  GENERADOR CONDENSADOR PANCAKE Manual de instalación  (株)コンテック ー PC一BXノM40 0(PC)用 液晶ディスプレイケーブルセッ  Philips LED solutions 129404000KX1  Istruzioni per l`uso e manuale d`installazione  instrucciones de manejo PF/PFQ      