1. Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x olx E f Response OK is returned when zooming was completed successfully after step drive For details on other responses refer to the Error List II Description 1 This command is used to drive the zoom lens 2 This command functions in the same way as when first the ZOOM button on the remote control or main unit panel is pressed and then the or gt button is pressed 3 The amount by which the lens is zoomed is constant and it is fixed in the system 4 Ifa zooming error occurs step drive cannot be controlled 5 There are no GET commands available for this command Il Example Control gt ZSTEPDRV TELE 1 step control is exercised over the zoom toward the TELE end lt I OK Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands 7 Error List Item Code TYPE Error character strings Error Remedy 1 0001 e BAD_SEQUENCE Communication sequence error Wait uni ia peace received before sending the next command 2 0002 e INVALID COMMAND Invalid undefined command Send a valid command 3 o004 e INVALID FORMAT Invalid command format eee i Turn on the power using the 4 0005 e NOT_POWER_S
2. Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response Temperature is returned as g TEMP lt n gt lt v gt For details on other responses refer to the Error List f Description 1 This inquires about the temperature sensor value 2 Number of temperature sensors varies according to model 3 When returning multiple temperature sensor values values will be separated with a comma There are cases when a number of sensors is 0 In this case there will not be a comma 4 For correspondence of temperature sensor sequence and actual installation location inquire separately Il Example Setting None Reference gt GET TEMP This retrieves the temperature sensor values lt g TEMP 5 37 1 63 0 38 9 29 7 32 4 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands TMPL Temperature limit inquiry f Format GETL TMPL lt n gt Number 0 to 255 lt v gt Temperature value 0 0 to 127 9 C f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response Private commands disclosed upon request Temperature limit is returned as g TMPL lt n gt lt v gt For details on other responses refer to the Error Lis
3. Command that sets values for each parameter The format is shown below Setting command Character string lt Parameter name gt A A lt Parameter value gt lt Setting command character strings gt For the definition of lt Parameter value gt refer to Parameter definitions Requests current value of each parameter The format is shown below Reference lt Reference command character string gt command Character string A lt Parameter name gt GETCKParameter name gt Revision History Date Revised by Approved by Canon Response Projector WUX10 MarkII User Commands Transmissions sent from Projector to PC in response to commands from PC Transmissionformat lt Response character string gt lt Delimiter gt lt Response character string gt Character strings consisting of one or more ASCII characters The first two characters are always lt one lowercase letter gt The first character indicates the response type Response A type Meaning Example IEC i__ State response LOK BUSY ete ome cere Warning cacao MUSER COMMAND eee e J A O LA Ss og g Reference command response g AVOL 10 lt Delimiters gt Delimiters for commands sent from PC f Type OK response BUSY response Example WARN response Example ERR response Example GET response Example After processing of each command is completed a response is se
4. Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands SIGNALSTATUS Signal status inquiry f Format GET L SIGNALSTATUS ASIGNALSTATUS f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response Current image signal input status is returned as g SIGNALSTATUS lt Signal status ID gt lt Signal status ID gt Signal status Meaning NO_SIGNAL Signal not detected DISPLAYING Image now displayed or display enable status SETTING Signal detection and display preparation in progress For details on other responses refer to the Error List II Description 1 This inquires about the current image signal input status 2 This returns the signal status of the selected input Use INPUT command for the input selection 3 e 1006 NOW_BLANK is returned during blanking f Example gt GET SIGNALSTATUS or SIGNALSTATUS lt g SIGNALSTATUS NO_SIGNAL Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands TEMP Temperature inquiry f Format GETL TEMP lt n gt Number 0 to 255 lt v gt Temperature value 0 0 to 127 9 C f Environment
5. 2 This command functions in the same way as when Display setting Screen color correction are selected on the menu 3 When ADJUST has been selected adjust the RGB adjustment values using the WBRGB command 4 The current screen color correction can be acquired using the applicable GET command GET we f Example Setting gt WB NORMAL This sets the screen color correction to Normal lt i OK Reference gt GET WB or WB This retrieves the screen color correction lt g WB GREENBOARD Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands WBRGB Screen color correction ADJUST f Format WBRGB lt R adjustment value Number gt V lt G adjustment value Number gt V lt B adjustment value Number gt GETLIWBRGB AWBRGB Setting values for lt R G B adjustment value Number gt are 20 to 20 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x z f Response OK is returned if the parameter was set properly For GET WBRGB or WBRGB current screen color correction adjustment value are returned as g WBRGB lt R adjustment value Number gt lt G adjustment value Number gt lt B adjustment value Number gt For details on other responses refer to the Error List II Des
6. GET DGAMMA Il example Setting gt DGAMMA WEAK This sets the dynamic gamma function to WEAK lt i OK Reference gt GET DGAMMA or DGAMMA This retrieves the dynamic gamma function state lt g DGAMMA WEAK Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands DOTS Total number of dots adjustment f Format DOTS lt Number of dots Number gt GETLIDOTS ADOTS f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x X O O X X X X f Response OK is returned if the parameter was set properly For GET DOTS or 2DOTS current total number of dots is returned as g DOTS lt Number of dots Number gt For details on other responses refer to the Error List II Description D This designates the total number of dots for one horizontal period 2 This command functions in the same way as when Display setting Input signal settings Total number of dots are selected on the menu 3 Ifthe input is neither A RGB1 nor A RGB2 e 200X INVALID_SOURCE is returned as an error response 4 If signals are not input e 2010 NO_SIGNAL is returned 5 Adjustment range is limited If number is invalid e 0801 INVALID_VALUE is returned 6 The GET command can be used to obtain the c
7. OK is returned if the parameter was set properly For GET NOSIG or NOSIG current display screen when no signal setting is returned as g NOSIG lt Parameters for setting display screen in no signal mode ID gt For details on other responses refer to the Error List f Description 1 This sets the display screen when no image signals are input 2 This command functions in the same way as when Display setting User screen setting Screen when no signal are selected on the menu 3 The GET command can be used to obtain the current display screen at no signal GET NOSIG Il Example Setting gt NOSIG BLUE This sets the Blue screen when no signals are input lt i OK Reference gt GET NOSIG or NOSIG This retrieves the screen when no signals are input lt g NOSIG BLUE Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands PJON Display screen at startup setting f Format PJON lt Parameters for setting display screen at startup ID gt GETLIPJON APJON lt Parameters for setting display screen at startup ID gt CANON Canon logo SKIP No display f Environment Power Input OFF ON PM D RGB JA RGB1 A RGB2 COMP VIDEO HDMI None xo lx E f Response OK is returned if the parameter was set properly For GET P
8. Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET BVOL or BVOL current BEEP sound setting is returned as g BVOL lt Beep sound setting Number gt For details on other responses refer to the Error List II Description 1 This sets the BEEP sound output 2 This command functions in the same way as when System setting Electronic sound are selected on the menu 3 The beep sound can be set even while the sound is muted but it will not sound even if beep sound output has been set 4 The current beep sound output status can be acquired using the applicable GET command GET BVOL f Example Setting gt BVOL 0 This mutes the BEEP sound lt i OK Reference gt GET BVOL or BVOL This retrieves the BEEP sound output state lt g BVOL 1 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands COMVER User command version inquiry f Format GETL COMVER ACOMVER f Environment Power Input OFF ON PM D RGB JA RGB1 A RGB2 COMP VIDEO HDMI None f Response Returns the user command version as g COMVER lt User command version Character string gt lt User command version gt 99 9999 For details on other
9. VIDEO HDMI None xo lx E f Response OK is returned if the parameter was set properly For GET LAMP or LAMP current lamp output is returned as g LAMP lt Lamp output setting parameters ID gt For details on other responses refer to the Error List II Description 1 This command is used to set the light quantity of the lamp to NORMAL or SILENT reduced light quantity appropriate for silent cooling 2 This command functions in the same way as when Image adjustment Lamp mode setting are selected on the menu 3 This sets the currently selected input signal and image mode 4 The current lamp output can be acquired using the applicable GET command GET LAMP Il Example Setting gt LAMP NORMAL The lamp output is set to NORMAL lt i OK Reference gt GET LAMP or LAMP This retrieves the lamp output lt g LAMP SILENT Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands LAMPCOUNTER Lamp ON time inquiry f Format GET L LAMPCOUNTER ALAMPCOUNTER f Environment Power Input OFF ON PM D RGB JA RGB1 A RGB2 COMP VIDEO HDMI None f Response Returns current lamp on time as g LAMPCOUNTER lt Lamp ON time Character string gt For details on other res
10. lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands HPIX VPIX Horizontal Vertical resolution adjustmen f Format HPIX lt Horizontal resolution Number gt VPIX lt Vertical resolution Number gt GETLJHPIX AHPIX GETLIVPIX AVPIX f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x O O O X X X X f Response OK is returned if the parameter was set properly For GET HPIX or HPIX GET VPIX or VPIX current horizontal vertical resolution is returned as g HPIX lt Horizontal resolution Number gt g VPIX lt Vertical resolution Number gt For details on other responses refer to the Error List f Description 1 This adjusts the horizontal and vertical resolution number of dots on the screen 2 This command functions in the same way as when Display setting Input signal settings Horizontal resolution adjustment or Vertical resolution adjustment are selected on the menu 3 Ifthe input is neither A RGB1 nor A RGB2 e 200X INVALID_SOURCE is returned as an error response 4 If signals are not input e 2010 NO_SIGNAL is returned 5 Adjustment range is limited If number is invalid e 0801 INVALID_VALUE is returned 6 The GET command can be used to retrieve the current horizontal and vertical position GET HPIX
11. lt Numerical value gt lt ID gt lt Character string gt lt Numerical value gt lt Sign gt lt Decimal character string Min 1 character to Max 5 characters gt The range of valid values is 32768 to 32767 lt ID gt 1 or more ASCII characters 20h to 7Fh lt Character string gt 0 or more ASCII characters 20h to 7Fh Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands 3 Communication Flow Transmission sent At the sending side PC the transmission is sent within character intervals of Te character interval timeout Transmission received At the receiving side Projector data able to be received within the character interval of Tc is held and receiving of a delimiter is considered transmission received If a received character interval exceeds Tc or a delimiter is not received within 256 characters all data already received is lost and the mode is reset to receive standby again Command Response One response is always returned for each command sent from the PC However note that a response may not be returned when the internal receive buffer overflows due to reception of a large amount of data Commands WithinTr Response The timeout interval between command and response Tr is 15 seconds Response Reception Timeout If a response is not received within Tr timeout interval between command and response while in response r
12. 4 This sets the currently selected input signal and image mode 5 The current contrast can be acquired using the applicable GET command GET cont f Example Setting gt CONT 3 This sets the contrast to 3 lt i OK Reference gt GET CONT or CONT This retrieves the contrast lt g CONT 3 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands DGAMMA Dynamic gamma f Format DGAMMA lt Dynamic gamma setting parameter ID gt GETLIDGAMMA ADGAMMA lt Dynamic gamma setting parameter ID gt OFF Off WEAK Weak STRONG Strong f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET DGAMMA or DGAMMA current dynamic gamma setting is returned as g DGAMMA lt Dynamic gamma setting parameter ID gt For details on other responses refer to the Error List II Description 1 The command is used to set the dynamic gamma function 2 This command functions in the same way as when Image adjustment Advanced adjustment Dynamic gamma are selected on the menu 3 This sets the currently selected input signal and image mode 4 The current dynamic gamma function status can be acquired using the applicable GET command
13. 6AXR Y 6 axis correction R Y hue saturation settings f Format 6AXR lt R hue Number gt V lt R saturation Number gt 6AXG lt G hue Number gt V lt G saturation Number gt 6AXB lt B hue Number gt V lt B saturation Number gt 6AXC lt C hue Number gt V lt C saturation Number gt 6AXM lt M hue Number gt V lt M saturation Number gt 6AXY lt Y hue Number gt V lt Y saturation Number gt GETLI6AXR A6AXR GETLI6AXG A6AXG GETLI6AXB A6AXB GETLI6AXC A6AXC GETLI6AXM A6AXM GETLI6AXY A6AXY Setting values for lt R G B C M Y hue Number gt are 20 to 20 Setting values for lt R G B C M Y saturation Number gt are 20 to 20 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x a f Response OK is returned if the parameter was set properly For GET 6AX or 26AX current 6 axis correction R Y hue saturation settings are returned as g 6AX lt hue Number gt lt saturation Number gt For details on other responses refer to the Error List f Description 1 This sets the 6 axis correction of the hue and color saturation for R to Y 2 This command functions in the same way as when Image adjustments Advanced adjustments 6 axis color adjustment are selected on the menu 3 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned 4
14. Function PC command parameter Digital zoom DZOOM_P DZOOM_M Presentation timer P_TIMER Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands Appendix 1 Reset Items What is initialized by the RESET command is set forth in the table below ALL SYSTEM IMAGE Item Setting Reference command Input source switching A RGB1 INPUT O Screen aspect 4 3 SCRNASPECT o o Aspect ee ASPECT Other AUTO e J HDMI overscan ONO eee J O HDMI input level NN es O J Input signal select AUTO SEL O J Progressive 2 PROG O 0 Menu display position Center renee nine O O Screen color correction NORMAL WB O J adjustment values R G B 0 0 0 WBRGB O Flip display NONE IMAGEFLIP O 0 No signal screen BLUE NOSIG O J Screen when BLANK BLACK BLANKCOLOR O O Startup screen CANON PJON r linagemode DICOM model DCM_SIM IMAGE Other STANDARD O 0 O Brightness 0 BRI O e O Contrast 0 CONT O O O Sharpness 0 SHARP O 0 O Gamma 0 GAMMA O 0 O Saturation 0 SAT O J Hue 0 HUE O J O Color temperature O eee O J O RGB gain adjustment 0 0 0 RGBGAIN o J O RGB offset adjustment 0 0 0 RGBOFFSET O J O Dynamic gamma Nee DGAMMA Other OFF O 0 O Flesh tone adjustment A A FTONEADJ Other OFF O 0 O 6 axis adjustment ON OFF OFF 6AXADJ O J O 6 axis adjustmen
15. GET VPIX f Example Setting gt HPIX 1024 This sets the horizontal resolution to 1024 lt i OK Reference gt GET VPIX or VPIX This retrieves the vertical resolution lt g VPIX 864 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands HPOS VPOS Horizontal Vertical position adjustment f Format HPOS lt Horizontal position Number gt VPOS lt Vertical position Number gt GETLIHPOS AHPOS GETLIVPOS AVPOS f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x X O O X X X X f Response OK is returned if the parameter was set properly For GET HPOS or HPOS GET VPOS or 2vPOS current horizontal vertical position is returned as g HPOS lt Horizontal position Number gt g VPOS lt Vertical position Number gt For details on other responses refer to the Error List II Description 1 This adjusts the horizontal and vertical position on the screen 2 This command functions in the same way as when Display setting Input signal settings Horizontal position adjustment or Vertical position adjustment are selected on the menu 3 Ifthe input is neither A RGB1 nor A RGB2 e 200X INVALID_SOURCE is returned as an error response 4 If signals are n
16. 6 axis adjustment parameter ID gt ON This sets the 6 axis adjustment to ON OFF This sets the 6 axis adjustment to OFF f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x i f Response OK is returned if the parameter was set properly For GET GAXADJ or 6AXADJ current 6 axis adjustment state is returned in g 6AXADJ lt 6 axis adjustment parameter ID gt For details on other responses refer to the Error List II Description 1 This command is used to select ON or OFF for the 6 axis adjustment 2 This command functions in the same way as when Image adjustments Advanced adjustments 6 axis adjustment are selected on the menu 3 In the case of 6 axis adjustment set the hue and color saturation of each axis using the GAXR to Y 6 axis correction R to Y hue color saturation setting commands 4 This sets the currently selected input signal and image mode 5 The current 6 axis adjustment setting can be obtained using the GET command GET GAXADJ Il example Control gt 6AXADJ ON The 6 axis adjustment is set to ON lt i OK Reference gt GET 6AXADJ or 6AXADJ The 6 axis adjustment ON or OFF setting is obtained lt g 6AXADJ ON Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands
17. These commands take effect when they have been set to valid using the 6 axis adjustment command 6AXADJ and they can be set separately 5 This sets the currently selected input signal and image mode 6 The current 6 axis color correction can be obtained using the GET command GET 6AXR G B C M f Example Setting gt 6AXR 8 5 The R hue is set to 8 and the color saturation is set to 5 lt i OK Reference gt GET 6AXR or 6AXR This retrieves the R hue and color saturation lt g 6AXR 12 8 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands ASCOMBO_ Defines auto setup combination f Format ASCOMBO_AF lt Auto set combination parameter ID gt ASCOMBO_AVK lt Auto set combination parameter ID gt ASCOMBO_AINP lt Auto set combination parameter ID gt ASCOMBO_ASC lt Auto set combination parameter ID gt GETUASCOMBO_AF ASCOMBO_AF GETUASCOMBO_AVK ASCOMBO_AVK GETUASCOMBO_AINP ASCOMBO_AINP GETUASCOMBO_ASC ASCOMBO_ASC lt Auto set combination parameter ID gt ON Combine OFF Do not combine f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x f Response OK is returned if automatic setup combination was set properly For GET ASCOMBO_ or ASCOMBO_ curren
18. codes Uppercase and lowercase of alphabetic characters are considered the same character Double byte characters and single byte characters are not distinguished All are considered single byte characters Communication No procedure procedure Flow control None Error control None Break signal Not supported Tc Character 5s Timeout between CR and LF is 10ms Time out Tr Command response 15s interval Item Communication System LAN Specifications Communication system Transmission speed Character length Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands Commands Request transmissions sent from PC to the projector Transmission format A lt Command character strings gt A lt Delimiters gt lt Command character strings gt Character strings consisting of 0 or more alphanumeric characters lt Delimiters gt One of CR 0Dh LF OAh CR LF ODh 0Ah Null 00h f Type Description Response Commands with a command character string length of 0 No command processing is performed Null Commands lt Null command character string gt Character strin 9 lt Character string with length 0 gt Projector control command The format is shown below Control lt Control command character string gt command Character string lt Control name gt KParameter value gt
19. refer to the Error List f Description 1 This command is used to drive the zoom lens continuously 2 This command functions in the same way as when first the ZOOM button on the remote control or main unit panel is pressed and then the or button is pressed 3 Zoom drive is started by specifying TELE or WIDE To stop the drive send the ZCONTDRV STOP command If no instruction was given to stop the drive the drive stops at the drive direction end 4 The following commands are acknowledged during zoom drive but zoom drive will also stop at the same time a POWER b ZCONTDRV STOP 5 The following commands are acknowledged during zoom drive and a response is returned while the drive continues a GET MODE e GET PRODCODE i LOCAL b GET POWER f GET ROMVER j RC c GET ERR g GET COMVER k MAIN d GET LAMPCOUNTER h REMOTE 1 NULL 6 There are no GET commands available for this command Il Example Control gt ZCONTDRV TELE Control over the zooming to the telephoto end is started lt I 0K Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands ZSTEPDRV Zoom lens step drive control f Format ZSTEPDRV lt Zoom lens step control parameter ID gt lt Zoom lens step control parameter ID gt WIDE This zooms to the wide angle end TELE This zooms to the telephoto end f Environment
20. responses refer to the Error List f Description 1 This inquires about the user command version of the projector 2 This inquiry can be executed in any status provided that AC power is supplied to the projector 3 The user command version consists of a 2 digit number followed by a 4 digit number Question marks may appear in place of the numerals if the firmware has not been upgraded correctly f Example gt GET COMVER or COMVER lt g COMVER 01 0000 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands CONT Contrast setting f Format CONT lt Contrast setting Number gt GETLICONT ACONT Setting values for lt Contrast setting Number gt are 20 to 20 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET CONT or CONT current contrast setting is returned as g CONT lt Contrast setting Number gt For details on other responses refer to the Error List II Description 1 This sets the screen contrast 2 This command functions in the same way as when Image adjustment Contrast setting are selected on the menu 3 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned
21. sets the input signal selection to AUTO lt i OK Reference gt GET SEL or SEL This retrieves the input signal lt g SEL 575p Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands SHARP Sharpness setting f Format SHARP lt Sharpness setting Number gt GETLISHARP ASHARP Setting values for lt Sharpness setting Number gt are 10 to 10 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET SHARP or SHARP current sharpness setting is returned as g SHARP lt Sharpness setting Number gt For details on other responses refer to the Error List f Description 1 This sets the screen sharpness 2 This command functions in the same way as when Image adjustment Sharpness setting are selected on the menu 3 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned 4 This sets the currently selected input signal and image mode 5 The current sharpness can be acquired using the applicable GET command GET SHARP ll Example Setting gt SHARP 3 This sets the sharpness to 3 lt i OK Reference gt GET SHARP or SHARP This retrieves the sharpness lt g SHARP 3
22. the Error List f Description 1 This sets the power management mode 2 This command functions in the same way as when System setting Power management mode are selected on the menu 3 Power management cannot be set to OFF if ON has been selected as the direct power on setting DPON ON e 1005 DIRECT_POWER_ON is returned 4 The current power management mode can be acquired using the applicable GET command GET PMM Il Example Setting gt PMM STANDBY This sets the power management to standby lt i OK Reference gt GET PMM or PMM This retrieves the power management mode lt g PMM EXIT Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands POWER This controls the power supply f Format POWERL lt Parameter ID gt GETLIPOWER APOWER lt Parameter ID gt ON Power ON OFF Power OFF f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None f Response OK is returned if the parameter was set properly For GET POWER or POWER current power supply status is returned as shown in the table below Response Status g POWER OFF OFF g POWER OFF20N OFF gt ON in transition g POWER ON ON g POWER 0N2PMM ON gt Standby in transit
23. when Display setting Input signal selection Tracking adjustment are selected on the menu 3 If the input is neither A RGB1 nor A RGB2 e 200X INVALID_SOURCE is returned as an error response 4 If signals are not input e 2010 NO_SIGNAL is returned 5 Adjustment range is limited If number is invalid e 0801 INVALID_VALUE is returned 6 The GET command can be used to retrieve the current tracking adjustment values GET TRACK Il Example Setting gt TRACK 25 The tracking adjustment value is set to 25 lt i OK Reference gt GET TRACK or TRACK This retrieves the tracking adjustment setting value lt g TRACK 21 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands VKS Vertical keystone setting f Format VKS lt Vertical keystone distortion value Number gt GETLIVKS AVKS f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x f Response OK is returned if the parameter was set properly For GET VKS or vKs current vertical keystone setting value is returned as g VKS lt Vertical keystone distortion value Number gt For details on other responses refer to the Error List f Description 1 This sets the vertical keystones 2 This command is ide
24. 4 When input is VIDEO and signals are not input e 2010 NO_SIGNAL is returned 5 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned 6 This sets the currently selected input signal and image mode 7 The GET command can be used to retrieve the current hue GET HUE Il Example Setting gt HUE 8 This sets the hue to 8 lt i OK Reference gt GET HUE or HUE This retrieves the hue lt g HUE 1 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon IMAGE Image mode setting Projector WUX10 MarkII User Commands f Format IMAGE lt Image mode setting parameter ID gt GETLIIMAGE A IMAGE lt Image mode setting parameter ID gt STANDARD Standard PRESENTATION Presentation SRGB sRGB MOVIE Movie PHOTO Environmental light compatible sRGB DCM_SIM DICOM monochrome e 000A INVALID_ PARAMETER is returned if the model is not DICOM compatible f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x z f Response OK is returned if the parameter was set properly For GET IMAGE or IMAGE current image mode is returned as g IMAGE lt Image mode setting parameter ID gt For details on other responses refer to the Error List II Description 1 This sets the image quality 2
25. 5 ROMVER cla as a eee 66 A 67 AUNAR aros 68 datada 69 A A eee 71 SIGNALS TATUS sesia RIE AE EE E E aaa 72 015 0 SSR ee Or E E E Re A 73 o A A 74 A 75 o E R 76 WB E O 77 A 78 A An 79 ZSTEPDRV A E E E NER 80 TEMO EIS temas errr eter ss 81 O Error PROC GS SUNG sc dE E A E tas 83 e OI rTM ee meer y Tener ener rey cee rere mcr ren cemrer ao rrrre em creeren teeny errr eer 85 Appendix 1 Reset Items 2 A nennen 86 iii Canon Projector WUX10 MarkII User Commands These specifications describe the methods of controlling the Projector WUX10 MarkII from the PC over an RS 232C connection or LAN Virtually all operations possible with the remote control can be controlled from the PC The following symbols are used in these specifications Description Space with 0 or more characters 20h Tab 09h or other separator Space with 1 or more characters 20h Tab 09h or other separator Separator between parameters F Data in can be omitted Same as OR Definition name is on the left side of this mark and definition description is on the right side Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands 2 Communication Specifications Communication Specifications The projector can be controlled via serial or LAN connection PC Projector connection status COM SERVICE LAN LAN Network Connection Specifications Speci
26. 6 9 O O O O O O 4 FULL 5 a5 5 x x x 4 ZOOM x Xx x A 2 sc 4 TRUE O O O 3 x 3 4 1 Valid when screen aspect 16 9 or 16 9 DIS and SD signals 2 Settable when screen aspect 16 9 or 16 9 DIS 3 Progressive allowable however 1080p is non allowable 4 Allowable Non Allowable differs according to selected input signal 5 Settable when screen aspect 16 10 J Response OK is returned if the parameter was set properly For GET ASPECT or ASPECT current screen display mode is returned as g ASPECT lt Screen setting parameters ID gt For details on other responses refer to the Error List II Description 1 This sets the screen sizes 2 This command functions in the same way as when Display settings Aspect are selected on the menu 3 Ifthe command cannot be supported INVALID_SOURCE is returned as an error response 4 Ifthe necessary signals are not input NO_SIGNAL is returned 5 The final screen settings are retained even when the power is turned off However the screen settings may be different if the input terminal or input signal is changed 6 The GET command can be used to retrieve the current screen display mode GET ASPECT Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands f Example Setting gt ASPECT 16 9 This sets the screen size to WIDE gt i OK Reference gt GET ASPECT or ASPECT This retrieves the screen size lt g A
27. CCH 2 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands RESET Reset f Format RESET lt Reset parameters ID gt lt Reset parameters ID gt LAMPTIME Lamp on time reset IMAGE Current image adjustment reset SYSTEM Initial system settings same as Factory settings in the menu ALL Initialize all f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the reset process is successful Furthermore the internal status established when a response other than the normal response OK has been returned is indeterminate For details on other responses refer to the Error List f Description 1 This resets the projector settings 2 What can be specified by the reset parameters for each reset type is provided below E Reset of lamp on time a The counter indicating the lamp replacement period is reset b This command functions in the same way as when System setting Lamp counter Reset are selected on the menu c Execute this command after replacing the lamp E Current image adjustment reset a The adjustment settings of the currently selected image mode are initialized b This command functions in the same way as when Image adjustment Image adjus
28. Canon Canon Projector WUX10 Markll User Commands Revision 1 2010 CANON INC Canon Projector WUX10 MarkII User Commands Revision History Revision No Version Date Page s Changes Revised by 1 01 0001 6 23 2009 ES First release Canon Projector WUX10 MarkII User Commands Table of Contents Revision O ene eee 1 A A 1 2 Communication SpecificatiONS ooooncccccoconncononnonncononnnnncnnnonononononnnnnnnnnnnoneninnnnns 2 Communication Specifications dandose 2 Communication System Serial c cccccccccccsessescssessescsseseescssesesscssseescsscseeecsscscsecsscsesecsssseescsssaeecsacatescseeaters 3 Communication System LAN ccccccccccssscsssscssscsssscscscecscssscssscsecscsescecsessssscsesecsessassceececsessessscseesesseceeses 3 A O 4 AO oo aned 5 Other data E a lara dit E tio tenon ica restate 6 3 Communication FlOW ooonnccnnnoccnccnnononnnnnnononnnonnnnnnncnnnonnnnnononnnnnnnnnnnnnnnnnnnnnnnnnnonnoos 7 Transmission Sbado ses cae sedeasacgenenies 7 TRAMSIMISSION PECEIVER AA O 7 Command Resp nse 2 24 2 lt c5 ccccugsadeeiessedegcege odes ineei sekoa an aebedegcegentogseesechdaudondey Jessedegeade ley alada iia 7 Response Receptions Timeout sacs cscsevnesices ccs svensscnanbeseceds exes E ISE E een ge naaa aran cion dai 7 Control ModE ssar
29. ETLIBRI ABRI Setting values for lt Brightness setting Number gt are 20 to 20 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET BRI or BRI current brightness is returned as g BRI lt Brightness setting Number gt For details on other responses refer to the Error List II Description D This sets the screen brightness 2 This command functions in the same way as when Image adjustments Brightness are selected on the menu 3 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned 4 This sets the currently selected input signal and image mode 5 The current brightness can be acquired using the applicable GET command GET BRI ll example Setting gt BRI 10 This sets the brightness to 10 lt i OK Reference gt GET BRI or BRI This retrieves the brightness lt g BRI 10 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands BVOL BEEP sound setting f Format BVOL lt Beep sound setting Number gt GETLIBVOL ABVOL lt Beep sound setting Number gt 0 BEEP sound mute 1 BEEP sound output f Environment
30. IDEO HDMI None f Response Product name is returned as g PRODCODE lt Product name Character string gt lt Product name Character string gt WUX10MarkII WUX10MarkIIM For details on other responses refer to the Error List f Description 1 This inquires about the product name of the projector 2 This inquiry can be executed in any status provided that AC power is supplied to the projector Il Example gt GET PRODCODE or PRODCODE lt g PRODCODE WUX10MarkII Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands PROG Progressive setting f Format PROG lt Progressive conversion setting parameters ID gt GETLIPROG APROG lt Progressive conversion setting parameters ID gt 0 OFF I ON 2 AUTO f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x X X X O O O X f Response OK is returned if the parameter was set properly For GET PROG or PROG progressive conversion setting is returned as g PROG lt Progressive conversion setting parameters ID gt For details on other responses refer to the Error List f Description 1 This command is used to set the progressive conversion processing to ON or OFF 2 This command functions
31. JON or PJon current display screen at startup setting is returned as g PJON lt Parameters for setting display screen at startup ID gt For details on other responses refer to the Error List II Description 1 This sets the screen displayed at startup 2 This command functions in the same way as when Display setting User screen setting Startup screen are selected on the menu 3 The GET command can be used to obtain the current screen displayed at startup GET PJON Il example Setting gt PJON CANON This sets the startup screen to Canon logo lt i OK Reference gt GET PJON or PJON This retrieves the startup screen lt g PJON SKIP Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands PMM Power management f Format PMM lt Power management setting parameters ID gt GETLIPMM APMM lt Power management setting parameters ID gt OFF OFF STANDBY Standby mode EXIT Exit mode f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET PMM or 2PMM current power management setting is returned as g PMM lt Power management setting parameters ID gt For details on other responses refer to
32. LUE Numerical parameters are invalid Set the parameters in the correct or outside the specified range range 1003 e IP_NOT_AVAILABLE IP conversion is not possible Switch to the correct input signal 1004 e POWER MANAGEMENT PPON ON cannot be setwhen so a setting other than PMM OFF FF PMM OFF PMM OFF cannot be set when 1005 e DIRECT_POWER_ON DPON ON Use the DPON OFF setting Invalid input signal resolution Additional information is indicated 203X e INVALID_RESOLUTION in parentheses Switch to an input signal with the MOVER PANEL RES input correct resolution signal resolution exceeds panel resolution Input was not switched since there Moteras oniy no 19 i INPUT_NOT_FOUND is no input signal at arnicular measures ae AUTOSETEXE INPUT P i Error codes are 4 digit hexadecimal strings X represents any character from 0 to 9 or from A to F Items with lower numbers have a higher priority Even when multiple errors have occurred the error with the highest rank is returned However errors of the same item number are ranked with the same priority Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands 8 Error Processing START Invalid undefined command YES Invalid command format gt INVALID_FORMAT Error judgment BAD_SEQUENCE INVALID COMMAND Command executable while pow
33. OCK Keylock setting 30 LAMP Lamp output setting 31 LAMPCOUNTER Lamp ON time inquiry 32 LANG Language select 33 LEDILLUMINATE Emotional LED lighting control 34 LMPT Lamp time inquiry 35 MAIN Front panel operation emulation 36 FTONEADJ Flesh tone adjustment 37 MODE Control mode switch 38 MUTE Mute control 39 NOSIG Display screen when no signal setting 40 PJON Display screen at startup setting Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands Item Commands Description 41 IPMM Power management 42 POWER This controls the power supply 43 PRODCODE Product information inquiry 44 PROG Progressive setting 45 RC Remote control operation emulate 46 RCCH Remote control channel setting 47 RESET Reset 48 IRGBGAIN RGB gain adjustment 49 RGBOFFSET RGB offset adjustment 50 ROMVER ROM version inquiry 51 SAT Color saturation setting 52 SCRNASPECT Screen aspect setting 53 SEL Input signal selection 54 SHARP Sharpness setting 55 SIGNALSTATUS Signal status inquiry 56 TEMP Temperature inquiry 57 TMPL Temperature limit inquiry 58 TRACK Tracking adjustment 59 VKS Vertical keystone setting 60 WB Screen color correction 61 WBRGB Screen color correction ADJUST 62 ZCONTDRV Zoom lens continuous drive control 63 ZSTEPDRV Zoom lens step drive control Revision Hist
34. OK Reference gt GET GAMMA or GAMMA This retrieves the gamma adjustment lt g GAMMA 3 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands GUIDE Guide setting f Format GUIDE lt Guide setting parameter ID gt GETLIGUIDE AGUIDE lt Guide setting parameter ID gt ON Guide display ON OFF Guide display OFF f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None xo lx E f Response OK is returned if the parameter was set properly For GET GUIDE or GUIDE current guide setting is returned as g GUIDE lt Guide setting parameter ID gt For details on other responses refer to the Error List f Description 1 This command is used to set the guide function display to ON or OFF 2 This command functions in the same way as when System setting Guide are selected on the menu 3 The guide is cleared immediately when GUIDE OFF is received while the guide is displayed 4 The current guide setting can be obtained using the GET command GET GUIDE Il example Setting gt GUIDE 0N The guide display is set to ON lt i OK Reference gt GET GUIDE or GUIDE The guide display setting status is obtained lt g GUIDE 0N Commands are indicated by gt and responses are indicated by
35. ONEADJ FTONE_M This sets the tone adjustment to Flesh tone adjustment medium lt i OK Reference gt GET FTONEADJ or FTONEADJ This retrieves the flesh tone adjustment level lt g FTONEADJ FTONE_M Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands GAMMA Gamma adjustment f Format GAMMA lt Gamma adjustment Number gt GETLIGAMMA AGAMMA Setting values for lt Gamma adjustment Number gt are 10 to 10 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x z f Response OK is returned if the parameter was set properly For GET GAMMA or GAMMA current gamma adjustment is returned as g GAMMA lt Gamma adjustment Number gt For details on other responses refer to the Error List II Description D This performs the Gamma adjustment 2 This command functions in the same way as when Image adjustment Gamma adjustment are selected on the menu 3 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned 4 This sets the currently selected input signal and image mode 5 The current gamma adjustment can be acquired using the applicable GET command GET GAMMA Il Example Setting gt GAMMA 1 This sets the gamma correction to 1 lt i
36. OPC AUTOPC 1 UP ASPECT ASPECT J DOWN IMAGE IMAGE LEFT BLANK BLANK RIGHT MUTE MUTING OK OK VOL VOL VOL VOL FREEXE FREEZE P TIMER PTIMER LAMP LAMP DZOOM DZOOM DZOOM DZOOM T UP y DOWN LEFT gt RIGHT OK OK Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands 5 Command List Item Commands Description 1 6AXADJ 6 axis adjustment ON OFF 2 6AXR Y 6 axis correction R Y hue saturation settings 3 ASCOMBO_ Defines auto setup combination 4 ASPECT Screen settings 5 AUTOPC Auto PC 6 AUTOSETEXE Auto setup 7 JAVOL Audio volume adjustment 8 BLANK BLANK function 9 BLANKCOLOR Screen when BLANK setting 10 BRI Brightness setting 11 BVOL BEEP sound setting 12 COMVER User command version inquiry 13 CONT Contrast setting 14 DGAMMA Dynamic gamma 15 DOTS Total number of dots adjustment 16 DPON Direct power on setting 17 JERR Error information inquiry 18 FCONTDRV Focus lens continuous drive control 19 FREEZE Freeze status 20 FSTEPDRV Focus lens step drive control 21 GAMMA Gamma adjustment 22 GUIDE Guide setting 23 HPIX VPIX Horizontal Vertical resolution adjustment 24 HPOS VPOS Horizontal Vertical position adjustment 25 HUE Hue setting 26 IMAGE Image mode setting 27 IMAGEFLIP Flip display 28 INPUT Input selection 29 KEYL
37. REP Button press start BLANK BLANK MUTE MUTE P TIMER P_TIMER LAMP LAMP DZOOM DZOOM_P DZOOM_P REP Button press start DZOOM DZOOM_M DZOOM_M REP Button press start FOCUS FOCUS ZOOM ZOOM gt REP Button press start Use the application to adjust the time between pressing of keys f Environment Power Input OFF ON PM D RGB JA RGB1 A RGB2 COMP VIDEO HDMI None f Response OK is returned when the button press request has been acknowledged successfully It does not indicate if the operation for the pressed button was executed properly Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands II Description 1 This emulates pressing of the remote control buttons for controlling the projector 2 With the emulation of the remote control operations the functions of the buttons corresponding to the parameters cannot necessarily be executed Emulation simply consists in emulating the pressing of the buttons 3 Function for transfer to special mode service mode is unavailable 4 A parameter with REP signifies button press start This is the same as the status in which the remote control button is held down Be absolutely sure to send the REP parameter and end the button pressing last of all The button pressing is ended in the cases below as well lt 1 gt When a panel or remote control button has been operat
38. SPECT TRUE Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands AUTOPC Auto PC f Format AUTOPC f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x oO x X O O X X X X f Response OK is returned if the control was executed properly For details on other responses refer to the Error List f Description D This executes Auto PC 2 This command is identical to pressing the AUTOPC button on the remote control 3 If the input is neither A RGB1 nor A RGB2 e 200X INVALID_SOURCE is returned as an error response 4 If signals are not input e 2010 NO_SIGNAL is returned 5 Execution of this command may modify the following setting values Total number of dots Tracking Horizontal vertical positions Number of horizontal vertical display dots 6 To confirm modified setting values use the GET command of the respective parameter For details refer to the GET commands below Setting GET Total number of dots GET DOTS Tracking GET TRACK Horizontal position GET HPOS Vertical position GET VPOS Number of horizontal display dots GET HPIX Number of vertical display dots GET VPIX f Example gt AUTOPC lt i OK Commands are indicated by gt and responses ar
39. This command functions in the same way as when Image adjustment Image mode setting are selected on the menu 3 The final settings for the image mode are retained even when the power is turned off 4 Changing the setting may modify the following setting values Setting Commands related to the settings Brightness BRI Contrast CONT Sharpness SHARP Gamma adjustment GAMMA Dynamic gamma DGAMMA Progressive PROG Saturation Hue SAT HUE Memory color adjustment MEMCADJ RGB gain offset adjustment RGBGAIN RGBOFFSET Lamp mode LAMP 6 axis adjustment GAXADJ 6 axis color correction 6AXR Y 5 The current image quality can be acquired using the applicable GET command GET IMAGE Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands f Example Setting gt IMAGE PRESENTATION This sets the image mode to Presentation lt i OK Reference gt GET IMAGE or IMAGE This references the current image mode lt g IMAGE CINEMA Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands IMAGEFLIP Flip display f Format IMAGEFLIP lt Image flip setting parameters ID gt GETL IMAGEFLIP A IMAGEFLIP lt Image flip setting parameters ID gt NONE None CEILING Ceiling Flip horizontally REAR Rear Flip vertica
40. UPPLIED The projector s power is off POWER ON command A The projector is switching power Wait until the power mode is ON j BUSY POWER modes OFF or PMM The parameter type is invalid 6 000A e INVALID_PARAMETER undefined Includes Fanes when Use the correct parameters the number of parameters is incorrect 7 000B e JOB_TIMEOUT Internal processing in the projector Resend the command has timed out i BUSY FOCUS The focus lens is being driven Wa t until the projector has finished driving the focus lens i BUSY ZOOM The zoom lens is being driven Wait until the projector has finished driving the zoom lens i BUSY LOGO_CAPTURE User image registration is in Wait until user image registration is progress complete 9 i BUSY IMAGE Image mode switching is in Wait until the projector has switched progress the image mode i BUSY NOW_SETTING Signal setting detection in Wait until the processing is progress completed i BUSY Internal processing in the projector Wait until the current processing is is in progress complete 1006 e NOW BLANK Cannot execute command since Resend the command after blanking operation is in progress canceling the blanking operation 1009 e NOW FREEZE Cannot execute command since Resend the command after freeze operation is in progress canceling the freeze operation 10 100A e NOW D ZOOM Cannot execute command since Resend the command after D zooming is in progress ca
41. actagaccccscaiagecediekeeadsdesdndedtaauedsdiageedsdacgscaginddededeaveasaetegiagectegsesentad dessdaaseetedtedsededacses 7 OCS E ess sacs EE E EAE EEE E E cases 7 4 Command dl oo oo 8 5 Command A e O OE nrn tae sre ae ee 10 6 Details O COMMANA seisid e drear EEE KEEA Eea 12 A O 13 CANARY iaa tao 14 ASCOMBO a da 15 ASPEC ni 16 AUTOBPC aa aaa ates 18 INN OSI D h I a D EEE E EA E E 19 AN Oia r ids 20 BLANK a E E Ee sheen ce T 21 BEAN OO OR dada does 22 BRI e E E E E is dettasetioeee 23 O O 24 COMVER EET T A T E E E tea E A A E E 25 CON E tii 26 DGAMMA eoio a aE 27 DOT PERAE PAE A AE EEE E O E AAE EEN E A A E EE E A AA 28 D ON o annonces 29 ERR aaa E a 30 POON TDR cima laa e AOE AEEA E NEARS AEDE 31 PREEZ Ene A 32 FSTEPDRV reanna rA a AEAEE EAER 33 FTONEA DJ 0 AnS 34 jli Canon Projector WUX10 MarkII User Commands GAMMA a ee ee 35 GUIDE nuria aes feausiaaeonmetedoae 36 PIP ROW Pi eae es 37 A AA 38 A E E E A E 39 a 40 IMAGEFLIP A AA 42 INPUT italia 43 A jira A anaes ai ae ee ee 44 A cseecsinaspoenneeasusasonetoasisscoassanene EE E 45 TAIN PC OLIN TR 5 2s cee sd cds epee esse ek pw a ee 46 A ay toads a a Laake E a 47 A vw eva pee cdi ose ea 48 EMET a laalaoa 49 MAIN neta Re A 50 MEDE soon dana idas 51 A A 52 WI caracol EES 53 e NEES 54 Piar ida 55 A A 56 A E E E 57 PROG era e a A 58 RO a e a E a a a a 59 RCOM e E see ee 61 RESET eea E E E RS 62 O Care NO ne er ene 64 A sede Restate Genco edit gated apes A 6
42. ameters ID gt D RGB D RGB A RGB1 A RGB1 A RGB2 A RGB2 COMP Component VIDEO Video HDMI HDMI f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x f Response OK is returned if the parameter was set properly For GET INPUT or INPUT current input selection is returned as g INPUT lt Input selection parameters ID gt For details on other responses refer to the Error List f Description D This controls the input selection 2 This command is identical to pressing the INPUT button on the remote control 3 The input can be selected automatically using the auto setup command AUTOSETEXE INPUT 4 The current input can be acquired using the applicable GET command GET INPUT Il example Setting gt INPUT VIDEO The input is set to VIDEO lt i OK Reference gt GET INPUT or INPUT This retrieves the input signal lt g INPUT A RGB1 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands KEYLOCK Keylock setting f Format KEYLOCK lt Key lock setting parameters ID gt GET L KEYLOCK AKEYLOCK lt Key lock setting parameters ID gt OFF No locking OFF MAIN Main key lock RC Remote control key lock f Environment Power Inp
43. can be used to retrieve the current volume GET AVOL Il example Setting gt AVOL 18 This sets the volume to 18 lt i OK Reference gt GET AVOL or AVOL This retrieves the volume lt g AVOL 18 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands BLANK BLANK function f Format BLANK lt BLANK parameter ID gt GETLIBLANK ABLANK lt BLANK parameter ID gt ON BLANK ON OFF BLANK OFF f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x f Response OK is returned if the parameter was set properly For GET BLANK or BLANK current BLANK status is returned as g BLANK ON g BLANK OFF For details on other responses refer to the Error List Il Description 1 This command is used to set the BLANK function 2 This command is identical to pressing the VOL and VOL button 3 The current BLANK settings can be obtained using the GET command GET BLANK Il Example Setting gt BLANK ON BLANK is set to ON lt i OK Reference gt GET BLANK or BLANK The current BLANK status is referenced lt g BLANK ON Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 Mar
44. cription D This sets the RGB adjustment values of the screen color correction 2 This command functions in the same way as when Display setting Screen color correction RGB adjustment are selected on the menu 3 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned 4 Although this setting is enabled when Adjustment ADJUST is selected by the screen color correction command WB it can be made independently 5 The GET command can be used to retrieve the current RGB adjustment values GET WBRGB Example Setting gt WBRGB 10 11 12 This sets R to 10 G to 11 and B to 12 lt i OK Reference gt GET WBRGB or WBRGB This retrieves the RGB adjustment values lt g WBRGB 10 0 19 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands ZCONTDRV Zoom lens continuous drive control f Format ZCONTDRV lt Zoom lens continuous control parameter ID gt lt Zoom lens continuous control parameter ID gt STOP This stops the zooming WIDE This zooms to the wide angle end TELE This zooms to the telephoto end f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x i f Response OK is returned when the drive was completed successfully For details on other responses
45. e indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands AUTOSETEXE Auto setup f Format AUTOSETEXE lt Auto set parameter ID gt lt Auto set parameter ID gt FOCUS Auto focusing VKS Auto keystone vertical execution SCRN Automatic screen color correction execution INPUT Automatic signal sensing execution f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response 1 OK is returned when the automatic processing was completed successfully For details on other responses refer to the Error List f Description 1 This command is used to execute auto setup 2 One of the following responses is returned if auto setup cannot be executed due to projector settings Projector Type settings Focus VKS SCRN INPUT BLANK x O x O e 1006 NOW_BLANK FREEZE x x x e 1009 NOW_FREEZE D ZOOM x x x e 100A NOW_D ZOOM Executable DIS x x x e 1008 INVALID_ SCREEN_ASPECT x Non executable DIS Digital Image Shift Error response O x x 3 One of the following responses is returned if an error has been detected at any part of the auto setup Type Response FOCUS e F002 SYSTEM AF VKS e F004 SYSTEM AK SCRN e F005 SYSTEM ASC 4 Ifthe input signal cannot be d
46. eception standby after sending a command at the PC resend the command in the response reception timeout Control Mode LOCAL mode and REMOTE mode on previous models SX50 SX6 SX60 X600 SX7 X700 have been removed You do not need to be aware of which mode it is in no need to use REMOTE and LOCAL commands to send user commands Other If AC power is supplied to the projector communication is possible regardless of whether the power is on or off The PC side cannot send a next user command before a response for the first command is returned If more than 2 user commands arrive at one port BAD_SEQUENCE will be returned in response to the second user command Response to the first processed user command will not be returned If user commands arrive at the LAN and service port simultaneously both will be processed It will be processed individually and return a response to each command to individual ports Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands 4 Command System MENU Control AUTOPC HDMI input level p letal number of dots adjustment DOTS Tracking adjustment TRACK JHorizontal Vertical position adjustment HPOS VPOS orizontal Vertical resolution adjustment User commands use only automatic selection of input signals Running of Auto PC will change the values set in Input signal settings Flip di
47. ed lt 2 gt When a command has been received Il Example Setting gt RC POWER lt i OK Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands RCCH Remote control channel setting f Format RCCH lt Remote control setting parameters ID gt GETLIRCCH ARCCH lt Remote control setting parameters ID gt 1 Remote control channel 1 2 Remote control channel 2 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET RCCH or RCCH current remote control channel setting is returned as g RCCH lt Remote control setting parameters ID gt For details on other responses refer to the Error List f Description 1 This command is used to set the channel of the remote control used at the projector end to 1 or 2 2 This command functions in the same way as when System setting Other settings Remote control setting are selected on the menu 3 The current remote control setting can be acquired using the applicable GET command GET RCCH Il Example Setting gt RCCH 1 This sets the remote control channel to ch1 lt i OK Reference gt GET RCCH or RCCH This retrieves the remote control setting state lt g R
48. er mode is OFF YES Power mode is OF gt NOT_ POWER SUPPLIED Command executable with PMM Power mode is MES PMM NOT_ POWER SUPPLIED BUSY POWER Switching power modes YES YES m 0 Invalid parameter type J gt INVALID_PARAMETER Undefined parameter ID Incorrect parameter number YES gt Focus lens driving gt BUSY FOCUS Zoom lens driving BUSY ZOOM User image registration in BUSY LOGO_CAPTURE progress Image mode switching in gt BUSY IMAGE progress Signal setting detection in i BUSY NOW SETTING progress Internal processing in progress Busy Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands Ae neo YES Limitations in input source Incorrect input source Requires input signal No input signal Invalid input signal INVALID_SOURCE NO_SIGNAL INVALID_SIGNAL Numerical parameter outside the specified range INVALID_ VALUE User command is executable FINISHED Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands Use the remote control emulation function RC command for the following functions
49. es are obtained lt g RGBOFFSET 10 0 19 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands ROMVER ROM version inquiry f Format GET L ROMVER AROMVER f Environment Power Input OFF ON PM D RGB JA RGB1 A RGB2 COMP VIDEO HDMI None f Response ROM version of the firmware is returned as g ROMVER lt ROM version Character string gt lt ROM version gt 99 999999 For details on other responses refer to the Error List f Description 1 This inquires about the version of the firmware 2 This inquiry can be executed in any status provided that AC power is supplied to the projector Example gt GET ROMVER or ROMVER lt g ROMVER 01 030602 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands SAT Color saturation setting f Format RGBGAIN lt R gain setting Number gt V lt G gain setting Number gt V lt B gain setting Number gt GETLIRGBGAIN ARGBGAIN Setting values for lt Color saturation setting value Number gt are 20 to 20 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x O O O O O X O
50. etected using the automatic signal sensing i INPUT_NOT_FOUND is returned 5 When automatic screen color correction SCRN has been completed successfully the screen color correction WB is set to ADJUST 6 There are no parameters to be executed together Execute them separately ll example Setting gt AUTOSETEXE FOCUS Auto focusing is executed lt i OK Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands AVOL Audio volume adjustment f Format AVOL lt Audio volume level Number gt GETLI AVOL AAVOL Setting values for lt Audio volume level Number gt are 0 to 20 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET AVOL or AVOL current audio volume level is returned as g AVOL lt Audio volume level Number gt For details on other responses refer to the Error List f Description 1 This adjusts the volume 2 This command is identical to pressing the VOL and VOL button on the remote control or the VOL on the front panel 3 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned 4 The volume level can be set even while the sound is muted 5 The GET command
51. f Example gt GET ERR or ERR lt g ERR FAULTY_LAMP Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands FCONTDRV Focus lens continuous drive control f Format FCONTDRV lt Focus lens continuous control parameter ID gt lt Focus lens continuous control parameter ID gt STOP This stops the focusing FAR This initiates focusing toward the far end NEAR This initiates focusing toward the near end f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x i f Response OK is returned when the drive was completed successfully For details on other responses refer to the Error List II Description 1 This command is used to drive the focus lens 2 This command functions in the same way as when first the FOCUS button on the remote control or main unit panel is pressed and then the or button is pressed 3 Focus drive is started by specifying NEAR or FAR To stop the drive add the STOP parameter and send this command If no instruction was given to stop the drive the drive stops at the drive direction end 4 The following commands are acknowledged during focus drive but focus drive will also stop at the same time a POWER b FCONTDRV STOP 5 The following commands are acknowledged during f
52. f Response OK is returned if the parameter was set properly For GET SAT or SAT current saturation setting value is returned as g SAT lt Color saturation setting value Number gt For details on other responses refer to the Error List II Description D This sets the screen color saturation 2 This command functions in the same way as when Image adjustment Color adjustment Color saturation setting are selected on the menu 3 Ifthe input is HDMI e 200X INVALID_SOURCE is returned as an error response 4 When image mode is not set to PHOTO e 2020 INVALID_IMAGE_MODE is returned as an error response even if the input is D RGB A RGB1 or A RGB2 5 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned 6 This sets the currently selected input signal and image mode 7 The GET command can be used to retrieve the current color saturation GET sat Example Setting gt SAT 10 This sets the color saturation to 10 lt i OK Reference gt GET SAT or SAT This retrieves the color saturation lt g SAT 1 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands SCRNASPECT Screen aspect setting f Format SCRNASPECT lt Screen aspect setting parameter ID gt GETLISCRNASPECT ASCRNASPECT lt Screen aspect set
53. fications Connection PC and projector connected on Connection 14 41 TCP IP Connection system a 1 1 basis system Connection 3 line connection of SD Connection Straight when connecting via signal line RD and SG signal line network Connection Connection cable 9pin RS 232C Cable Cross cable LAN Cable Send Data SD Send Data Receive gt E Receive Data Data Signal Signal Ground Ground Signal lines other than the three lines of SD RD and SG are not used in the projector Loop back its own signals at the PC side if necessary Revision History Date Revised by Approved by Canon Item Projector WUX10 MarkII User Commands Communication System Serial Specifications Communication system RS 232 C Start stop synchronization Semi duplex communication Transmission speed 19 2 Kbps Character length 8 bits character Stop bit 2 bits Parity None Transmission format Variable length record with terminal as delimiter Maximum transmission length Maximum of 256 characters bytes including delimiters Delimiters Delimiters are one of CR LF CR LF Null 0 delimiters are identified automatically Response delimiters are identical to command delimiters Transmission codes ASCII code General purpose characters 20h to 7Fh Tab 09h Codes other than those above and delimiters are considered other separator
54. icated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands FTONEADJ Flesh tone adjustment f Format FTONEADJ lt Flesh tone adjustment parameter ID gt GETLIFTONEADJ AFTONEADJ lt Memory color adjustment parameter ID gt OFF No adjustment FTONE_L Flesh tone adjustment light FTONE_M Flesh tone adjustment medium FTONE_H Flesh tone adjustment heavy f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x z f Response OK is returned when flesh tone has been adjusted successfully For GET FTONEADJ or FTONEADJ current flesh tone adjustment is returned as g FTONEADJ lt Flesh tone adjustment parameter ID gt For details on other responses refer to the Error List II Description 1 This command is used by selecting No adjustment Flesh tone adjustment light to Flesh tone adjustment heavy 2 This command functions in the same way as when Image adjustment Advanced adjustment Flesh tone adjustment are selected on the menu 3 This sets the currently selected input signal and image mode 4 The current flesh tone adjustment setting can be obtained using the GET command GET FTONEADJ 5 With the WUX10 Memory color adjustment function is not available Il example Control gt FT
55. in the same way as when Display setting Progressive are selected on the menu 3 This sets the currently selected input signal and image mode 4 The current value can be acquired using the applicable GET command GET PROG The menu display statuses are as listed in the table below by model Menu display statuses etc When signals from a progressive source are input the progressive conversion setting cannot be selected and the field will be blank on the menu Il Example Setting gt PROG 0 This sets the progressive conversion setting to OFF lt i OK Reference gt GET PROG or PROG This acquires the progressive conversion processing status lt g PROG 1 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands RC Remote control operation emulate f Format RCLl lt Remote control emulation button parameters 1ID gt lt Remote control emulation button parameters ID gt POWER POWER POWER_OFF POWER button pressed twice MENU MENU AUTO SET AUTOSET INPUT INPUT ASPECT ASPECT AUTOPC AUTOPC KEYSTONE KEYSTONE UP UP UP REP Button press start DOWN DOWN DOWN RE P Button press start LEFT LEFT LEFT REP Button press start RIGHT RIGHT RIGHT REP Button press start OK OK IMAGE IMAGE FREEZE FREEZE VOL VOL_P VOL_P REP Button press start VOL VOL_M VOL_M
56. ing the GET command GET DPON f Example Setting gt DPON ON Direct power on is set to ON lt i OK Reference gt GET DPON on DPON The current direct power on setting is obtained lt g DPON ON Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon ERR Error information inquiry f Format GET ERR AERR f Environment Projector WUX10 MarkII User Commands Power Input OFF PM D RGB ON A RGB1 A RGB2 HDMI None COMP VIDEO J Response Returns the current error information as g ERR lt ErrorID Character string gt lt ErrorID Character string gt NO_ERROR ABNORMAL_TEMPERATURE FAULTY_LAMP FAULTY_LAMP_COVER FAULTY_COOLING_FAN FAULTY_POWER_SUPPLY FAULTY_AK FAULTY_ASC FAULTY_AF FAULTY_POWER_ZOOM FAULTY_POWER_FOCUS No error Temperature error Lamp error Lamp cover error Cooling fan error Power supply error AK error ASC error AF error Zoom error Focus error For details on other responses refer to the Error List f Description a 2 3 This inquires about the current error information This inquiry can be executed in any status provided that AC power is supplied to the projector Information when the warning LED of the projector is flashing can be obtained NO_ERROR is returned when the warning LED is not lighted
57. ion g POWER PMM Standby s POWER PMM20N Standby gt ON in transition s POWER 0N20FF ON gt OFF in transition For details on other responses refer to the Error List f Description 1 This performs ON OFF control of the power supply 2 This command is identical to pressing the POWER button on the remote control 3 Processing of other commands including ZOOM FOCUS will be interrupted at POWER OFF when the power is ON 4 BUSY will be returned at POWER ON during power OFF transition For other cases T OK will always be returned 5 After sending this command use GET POWER to obtain the power supply state at regular intervals and check that it is in the controlled state off or on 6 The current power supply status can be referenced using the applicable GET command GET POWER 7 Even when it is powered up by using this command Prepare for lamp replacement Lamp replacement warning Clean filter warning will display for 10 seconds as usual f example Control gt POWER ON lt i OK Reference gt GET POWER or POWER lt g POWER OFF Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands PRODCODE Product information inquiry f Format GET L PRODCODE APRODCODE f Environment Power Input OFF ON PM D RGB JA RGB1 A RGB2 COMP V
58. ions of the buttons corresponding to the parameters cannot necessarily be executed Emulation simply consists in emulating the pressing of the buttons 3 A parameter with REP signifies button press start which the front panel button is held down Be absolutely sure to send the REP parameter and end the button pressing last of all The button pressing is ended in the cases below as well lt 1 gt When a panel or remote control button has been operated lt 2 gt When some command has been received This is the same as the status in Example Setting gt MAIN FOCUS lt i OK Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands MODE Control mode switch f Format REMOTE LOCAL GET L MODE MODE f Environment Power Input OFF ON PM D RGB JA RGB1 A RGB2 COMP VIDEO HDMI None f Response OK is always returned with the control mode switch setting For GET MODE or MODE current control mode is returned as g MODE REMOTE g MODE LOCAL For details on other responses refer to the Error List f Description 1 There are no local and remote control modes with this version of the user commands however this command exists to maintain compatibility with previous versions of the user commands 2 However differences bet
59. kII User Commands BLANKCOLOR Screen when BLANK setting f Format BLANKCOLOR lt Screen when BLANK setting parameter ID gt GETLIBLANKCOLOR ABLANKCOLOR lt Screen when BLANK setting parameter ID gt BLACK Black screen BLUE Blue screen f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET BLANKCOLOR or BLANKCOLOR current screen when BLANK setting is returned as g BLANKCOLOR lt BLANK display screen setting parameter ID gt For details on other responses refer to the Error List f Description 1 This command is used to set the screen when BLANK 2 This command functions in the same way as when Display settings User screen setting Screen when blank are selected on the menu 3 The current screen when BLANK setting can be obtained using the GET command GET BLANKCOLOR Il Example Setting gt BLANKCOLOR BLACK Set to Black screen when screen is BLANK lt Ok Reference gt GET BLANKCOLOR or BLANKCOLOR Screen when BLANK setting is obtained lt g BLANKCOLOR BLACK Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands BRI Brightness setting f Format BRI lt Brightness setting Number gt G
60. le Setting gt FREEZE ON Freezes image lt i OK Reference gt GET FREEZE or FREEZE The current freeze status is referenced lt g FREEZE 0N Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands FSTEPDRV Focus lens step drive control f Format FSTEPDRV lt Focus lens step control parameter ID gt lt Focus lens step control parameter ID gt FAR This initiates focusing toward the far end NEAR This initiates focusing toward the near end f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned when focusing was completed successfully after step drive For details on other responses refer to the Error List II Description 1 This command is used to drive the focus lens 2 This command functions in the same way as when first the FOCUS button on the remote control or main unit panel is pressed and then the or gt button is pressed 3 The amount by which the lens is focused is constant and it is fixed for the system 4 Ifa focusing error occurs step drive cannot be controlled 5 There are no GET commands available for this command Il example Control gt FSTEPDRV NEAR 1 step control is exercised over the focus toward the NEAR end lt I OK Commands are ind
61. lly REAR_CEILING Rear ceiling Flip horizontally and vertically f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x z f Response OK is returned if the parameter was set properly For GET IMAGEFLIP or IMAGEFLIP current flip display setting is returned as g IMAGEFLIP lt Image flip setting parameters ID gt For details on other responses refer to the Error List II Description 1 This command is used to flip the screen display in various ways vertically or horizontally 2 This command functions in the same way as when Display setting Flip display are selected on the menu 3 When the display is flipped the keystone distortion settings are initialized set to VKS 0 4 The current flip display status can be acquired using the applicable GET command GET IMAGEFLIP Il example Setting gt IMAGEFLIP REAR This displays the image backwards flip vertically on the screen lt i OK Reference gt GET IMAGEFLIP or IMAGEFLIP This retrieves the flip display state lt g IMAGEFLIP REAR CEILING Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands INPUT Input selection f Format INPUT lt Input selection parameters ID gt GETLJINPUT AINPUT lt Input selection par
62. nceling D zooming 1008 e NOW SPECIAL MENU Cannot execute command in Resend the command after exiting current menu mode the current menu mode Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands Item Code TYPE Error character strings Error Remedy F001 e SYSTEM UNKNOWN An internal error has occurred Resend the command An error occurred at EME PTE AUTOSETEXE FOCUS 11 An error occurred at Eliminate the cause of the error and F004 oe ed AUTOSETEXE VKS resend the command An error occurred at PAS SYSTEM ASC AUTOSETEXE SCRN 12 Eoxx e COMMUNICATION ERROR A communication protocol violation p esend the command has occurred in the projector 1008 e Cannot execute command under Change the screen aspect ratio INVALID_SCREEN_ASPECT current screen aspect ratio setting setting Cannot execute command with 14 200x e INVALID SOURCE Curent input source Change the input source Current input source is indicated in parentheses 2010 e NO_SIGNAL No input signal Supply the input signal Cannot execute command with 15 i i 201x e INVALID_SIGNAL Currentinput signal Change the input signal Current input signal is indicated in parentheses 16 2020 e INVALID IMAGE MODE Cannot execute command with Ghange the image mode current image mode 17 0801 e INVALID VA
63. nment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x olx X X X O O X X f Response OK is returned if the parameter was set properly For GET SEL or SEL current input signal is returned as g SEL lt Detected input signal ID gt Refer to Description For details on other responses refer to the Error List f Description 1 This selects the input signal 2 This command functions in the same way as when Display setting Input signal selection AUTO are selected on the menu 3 If the input is neither COMP S VIDEO nor VIDEO e 200X INVALID_SOURCE is returned as an error response 4 If signals are not input e 2010 NO_SIGNAL is returned 5 The current input signal can be acquired using the applicable GET command GET SEL List of signals which can be detected 1 Parameter Remarks PAL Includes PAL M and PAL N SECAM NTSC Includes NTSC4 43 1080p 1080i Includes 540p 1080i non interlaced signal 10351 List of signals which can be detected 2 Parameter Remarks 720p 576p 480p 576i Includes 288p PAL non interlaced signal 480i Includes 240p NTSC non interlaced signal UNKNOWN No color 1080p and other signals Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands Example Setting gt SEL AUTO This
64. nt indicating that the next command can be received lt OK response character string gt i OK This response is sent when a command cannot be received during processing Wait for a few moments and then try sending the command again lt BUSY response character string gt i BUSY gt IMAGE STANDARD lt i BUSY This response is sent when warning information is issued that this command cannot be executed lt Warning response character string gt w lt Warning description gt gt IMAGE STANDARD lt w USER_COMMAND VERSION _IS_ UPDATED An error message is output lt Error response character string gt e lt Error code gt lt Error code gt is expressed as a four digit hexadecimal number Refer to Error List lt Error message gt gt abcdefg lt e 0002 INVALID COMMAND Request response for each parameter lt GET response character string gt g lt Parameter name gt lt Value gt gt GET LANG or LANG lt g LANG JPN Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands Other f Transmission recognition Transmission is recognized when delimiter is received Even if a maximum transmission length is received the entire received transmission will be lost unless a delimiter is received The lt Parameter value gt is defined as shown below lt Parameter value gt lt Value 1 gt V lt Value 2 gt V V lt Value n gt lt Value gt
65. ntical to pressing the KEYSTONE button on the remote control 3 The settable keystone range varies depending on the input signal screen size number of horizontal and vertical dots and other factors If keystone values are outside the range e 0801 INVALID_VALUE is returned 4 The GET command can be used to obtain the current vertical horizontal keystone value GET vKs Il Example Setting gt VKS 23 This sets the vertical keystone to 23 lt i 0K Reference gt GET VKS or VKS This retrieves the vertical keystone lt g VKS 23 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands WB Screen color correction f Format WB lt Screen color correction parameters ID gt GETOWB AWB lt Screen color correction parameters ID gt NORMAL Standard GREENBOARD Blackboard ADJUST Adjust f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET WB or wB current screen color correction is returned as g WB lt Screen color correction parameters ID gt For details on other responses refer to the Error List f Description 1 The screen color correction is set to Normal Blackboard or Adjust
66. ocus drive and a response is returned while the drive continues a GET MODE e GET PRODCODE i LOCAL b GET POWER f GET ROMVER j RC c GET ERR g GET COMVER k MAIN d GET LAMPCOUNTER h REMOTE l NULL 6 For other commands not included in 4 nor 5 i BUSY FOCUS is returned and focus drive continues 7 There are no GET commands available for this command Il Example Control gt FCONTDRV NEAR Control over the focusing to the near end is started lt i OK Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands FREEZE Freeze status f Format FREEZE lt FREEZE parameter ID gt GETLIFREEZE AFREEZE lt FREEZE parameter ID gt ON Image now frozen OFF Image now not frozen f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x z f Response OK is returned if the parameter was set properly For GET FREEZE or FREEZE current freeze status is returned as gFREEZE ON g FREEZE OFF For details on other responses refer to the Error List f Description 1 This command is used to freeze the image 2 This command is identical to pressing the FREEZE button on the remote control 3 The current freeze status can be obtained using the GET command GET FREEZE Examp
67. ory Date Revised by Approved by Canon Projector WUX10 MarkII User Commands 6 Details of Command Descriptions of each command are provided starting from the next page The command descriptions have the format shown below Alphabetic command name This briefly describes the command function f Format This indicates the command format f Environment This defines the environments that support the command power supply state input signal state Power 1 Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None 2 3 4 5 5 5 5 5 5 6 1 Power Executable regardless of power supply state when marked by 2 OFF O when power supply state is OFF 3 ON O when power supply state is ON 4 PM O when the power supply state is enabled while power management is in standby 5 Input The command is enabled in states marked by O The command is executable regardless of input when marked by 6 None Input signal is required when X f Response This describes the command response f Description This includes the command function conditions and notes example This provides command usage examples Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands 6AXADJ 6 axis adjustment ON OFF f Format 6AXADJ lt 6 axis adjustment parameter ID gt GETL 6AXADJ A6AXADJ lt
68. ot input e 2010 NO_SIGNAL is returned 5 Adjustment range is limited If number is invalid e 0801 INVALID_VALUE is returned 6 The GET command can be used to retrieve the current horizontal and vertical position GET HPOS GET VPOS Il Example Setting gt HPOS 12 This sets the horizontal position to 12 lt i OK Reference gt GET VPOS or VPOS This acquires the vertical position lt g VPOS 8 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands HUE Hue setting f Format HUE lt Hue setting value Number gt GETL HUE AHUE Setting values for lt Hue setting value Number gt are 20 to 20 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x x x x o x a O X Il Response OK is returned if the parameter was set properly For GET HUE or HUE current hue setting is returned as g HUE lt Hue setting value Number gt For details on other responses refer to the Error List II Description 1 This sets the screen hue 2 This command functions in the same way as when Image adjustment Color adjustment Hue setting are selected on the menu 3 If the input is neither COMP nor VIDEO e 200X INVALID_SOURCE is returned as an error response
69. ponses refer to the Error List lt Lamp ON time Character string gt Lamp ON time ON time H TG 0 359 66____ 360 719 666____ 120 1079 6666___ 1080 1439 GGGGG__ 14401799 GGGGGY__ 1800 1899 GGGGGYY_ 1900 1999 TGGGGGYYR 2000 For all other responses refer to Error List II Description 1 This inquires about the current lamp ON time 2 This inquiry can be executed in any status provided that AC power is supplied to the projector f Example gt GET LAMPCOUNTER or LAMPCOUNTER lt g LAMPCOUNTER GG J Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands LANG Language select f Format LANG lt Language selection parameters ID gt GETLILANG ALANG lt Language selection parameters ID gt ENG English DUT Dutch NOR Norwegian FRA French RUS Russian TUR Turkish GER German CHS Chinese simplified POL Polish ITA Italian CHT Chinese traditional HUN Hungarian SPA Spanish KOR Korean CZE Czech POR Portuguese JPN Japanese ARA Arabic SWE Swedish FIN Finnish DAN Danish f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x a f Response OK is returned if the parameter was set
70. properly For GET LANG or LANG current selected language is returned as g LANG lt Language selection parameters ID gt For details on other responses refer to the Error List II Description 1 This switches the screen display language 2 This command functions in the same way as when System setting Languages are selected on the menu 3 The currently set language can be acquired using the applicable GET command GET LANG Il example Setting gt LANG SWE This sets the display language to Swedish lt i OK Reference gt GET LANG or LANG This retrieves the language lt g LANG SWE Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands LEDILLUMINATE Emotional LED lighting control f Format LEDILLUMINATE lt LED lighting control setting parameter ID gt GETLILEDILLUMINATE ALEDILLUMINATE lt LED lighting control setting parameter ID gt ON This sets the LED display to ON OFF This sets the LED display to OFF f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x lo x f Response OK is returned if the parameter was set properly For GET LEDILLUMINATE or LEDILLUMINATE current emotional LED lighting setting is returned as g LEDILLUMINATE lt LED lighting control se
71. splay IMAGEFLIP PROG Screen when no signal User screen setting oo S O Brightness setting BRI Image adjustment QO Advanced adjustment Ambient light System setting BVOL K GUIDE Slideshow interval ___ o lt o fe x m lt o o Q A O RGB adjustment WBRGB NOSIG Screen when blank BLANKCOLOR Startup screen PON HUE DGAMMA Flesh color adjustment FTONEADJ 6 axis color adjustment GAXADJ 6AXR Y A Remote control setting RCCH Menu display time EA Password setting IE Password registration O See RESET RESET LAMPTIME Network settings reset RESET RESET SYSTEM Revision History Date Revised by Approved by Projector WUX10 MarkII User Commands Running of Auto PC will change the values set in Input signal settings mpsmm 7 MENU Ip zoom _______ ________ P TIMERI LAMP Remote controlemulate ROSS Reference X indicates functions that are available in the menu but not available in the user commands POWER POWER POWER POWER AUTO SET AUTOSET AUTO SET AUTOSET MENU MENU MENU MENU KEYSTONE KEYSTONE KEYSTONE KEYSTONE FOCUS FOCUS FOCUS FOCUS ZOOM ZOOM ZOOM ZOOM INPUT INPUT INPUT INPUT AUTOPC AUTOPC AUT
72. stment f Format RGBGAIN lt R gain setting Number gt V lt G gain setting Number gt V lt B gain setting Number gt GETLIRGBGAIN ARGBGAIN Setting values for lt R G B gain setting Number gt are 60 to 60 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x z f Response OK is returned if the parameter was set properly For GET RGBGAIN or RGBGAIN current RGB gain adjustment values are returned as g RGBGAIN lt R gain setting Number gt lt G gain setting Number gt lt B gain setting Number gt For details on other responses refer to the Error List II Description 1 This command is used to adjust the gain of the R G and B colors 2 This command functions in the same way as when Image adjustment Color adjustment Gain adjustment are selected on the menu 3 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned 4 This sets the currently selected input signal and image mode 5 The current RGB gain values can be obtained using the GET command GET RGBGAIN Il example Setting gt RGBGAIN 10 11 12 The R gain is set to 10 G gain to 11 and B gain to 12 lt i 0K Reference gt GET RGBGAIN or RGBGAIN The RGB gain values are obtained lt g RGBGAIN 10 0 19 Commands are indicated by gt and responses are indicated by lt Revision History Date Re
73. t f Description 1 This returns the limit value of machine stoppage of each temperature sensors 2 Number of temperature sensors varies according to model 3 When returning multiple temperature sensor values values will be separated with a comma There are cases when a number of sensors is 0 In this case there will not be a comma 4 For correspondence of temperature sensor sequence and actual installation location inquire separately Il Example Setting None Reference gt GET TMPL This retrieves the temperature sensor limit values lt g TMPL 5 71 0 90 0 57 0 44 0 53 0 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands TRACK Tracking adjustment f Format TRACK lt Adjustment value Number gt GETLITRACK ATRACK f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x X O O X X X X f Response OK is returned if the parameter was set properly For GET TRACK or TRACK current tracking adjustment value is returned as g TRACK lt Adjustment value Number gt For details on other responses refer to the Error List f Description 1 This is used for adjustment when tracking synchronization is out of sync and the screen flickers 2 This command functions in the same way as
74. t SAT HUE 0 0 6AXR Y O O O Ambient light type Fluorescent lamp O O O Ambient light level Medium freee nn nnn O 0 O Lamp mode NORMAL LAMP Auto focus ON r eee Auto koyotina ON oo Auto input ON Automatic screen color correction OFF Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands ALL SYSTEM IMAGE Item Setting Reference command O 0 Power management OFF PMM O J Direct power on OFF DPON O O BEEP sound 1 BVOL O O Keylock OFF KEYLOCK O Language ENG LANG O 0 Guide ON GUIDE O LED illumination ON LEDILLUMINATION O Remote control 1 RCCH 0 Menu display time Normal e 0 o Password setting OFF ae O O Password character None e O Network function OFF fe O O Volume 10 AVOL O O Vertical keystone 0 VKS O O Digital image shift Oe o O Presentation timer OFF e O 0 Mute OFF MUTE Oo O Lamp ready indicator off flag OFF e Revision History Date Revised by Approved by
75. t auto setup sequence combination is returned as g ASCOMBO_ ON or g ASCOMBO_ 0FF For details on other responses refer to the Error List f Description 1 This sets whether to combine a sequence in the auto setup 2 This command functions in the same way as when System settings Auto setup are selected on the menu 3 Even if it has been set using this command AUTOSETEXE may not be executed depending on other status of the projector screen aspect etc 4 Also refer to the AUTOSETEXE command 5 The current auto setup combination can be obtained using the GET command f Example Setting gt ASCOMBO_AF ON Auto focusing is executed during auto setup execution lt i OK Reference gt GET ASCOMBO_AVK or ASCOMBO_AVK Auto focus execution setting in current auto setup is obtained lt g ASCOMBO_AVK 0N Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands ASPECT Screen settings f Format ASPECT lt Screen setting parameters ID gt GETLJASPECT AASPECT lt Screen setting parameters ID gt AUTO Auto 4 3 4 3 16 9 16 9 FULL Full screen ZOOM Zoom TRUE Real f Environment Power Input OFF ON PM Parameter D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x O x AUTO O O O O x O 4 4 3 O O O O O O 4 1
76. ting parameter ID gt 4 3 4 3 display 16 9 16 9 display 4 3_DIS 4 3 digital image shift 16 9_DIS 16 9 digital image shift 16 10 16 10 display f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x ol x f Response OK is returned if the parameter was set properly For GET SCRNASPECT or SCRNASPECT current screen aspect setting is returned as g SCRNASPECT lt Screen aspect setting parameter ID gt For details on other responses refer to the Error List f Description 1 This sets the screen aspect 2 This command functions in the same way as when Display setting Screen aspect are selected on the menu 3 The GET command can be used to retrieve the current screen aspect GET SCRNASPECT 4 The final screen aspect settings are retained even when the power is turned off Il Example Setting gt SCRNASPECT 16 9 This sets the screen aspect to 16 9 gt i 0K Reference gt GET SCRNASPECT or SCRNASPECT This retrieves the screen aspect lt g SCRNASPECT 4 3 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands SEL Input signal selection f Format SEL lt Input signal selection parameter ID gt GETLISEL ASEL lt Input signal selection parameter ID gt AUTO Auto f Enviro
77. tment reset are selected on the menu If there is an input signal the image adjustment items are initialized and then the adjustment values are optimized for the signal E Reset of system settings a The following items are initialized Image adjustment items all image modes Initial settings executed For details refer to RESET items at the end of these specifications b This command functions in the same way as when System setting Other settings Factory settings are selected on the menu E Initialize all a The following items are initialized Image adjustment items all image modes Initial settings executed Input source Language For details refer to RESET items at the end of these specifications Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands Notes a The power must never be turned off while this command is being executed b After the Factory settings be absolutely sure to turn the power off and then restart c NO_SIGNAL may be returned as the response to the command after Current image adjustment reset or System initial setting has been executed f Example Control gt RESET LAMPTIME This resets the lamp on time lt i OK Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands RGBGAIN RGB gain adju
78. tting parameter ID gt For details on other responses refer to the Error List II Description 1 This command is used to control the lighting of the emotional LED 2 This command functions in the same way as when System setting LED illumination are selected on the menu 3 The current LED illumination setting can be obtained using the GET command GET LEDILLUMINATE f Example Setting gt LEDILLUMINATE ON The LED display is set to ON lt i OK Reference gt GET LEDILLUMINATE or LEDILLUMINATE The ON or OFF setting for the LED display is obtained lt g LEDILLUMINATE 0N Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands LMPT Lamp time inquiry f Format GETOLMPT ALMPT LMPT lt h h h h gt lt mm gt lt hhhh gt Hours 065565 lt mm gt Minutes 0059 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x f Response For GET LMPT or LMPT current lamp time is returned as g LMPT lt hhhh gt lt mm gt For details on other responses refer to the Error List f Description 1 This inquires the lamp time Value of Oh0m to 65565h59m is returned 2 Because inner equivalent value is returned the hour of the lamp is not the same as the actual hour 3 This inquir
79. urrent total number of dots GET pors Il Example Setting gt DOTS 1650 The total number of dots is 1650 lt i 0K Reference gt GET DOTS or DOTS This retrieves the total number of dots lt g DOTS 1200 Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands DPON Direct power on setting f Format DPON lt Direct power on setting parameter ID gt GETLIDPON ADPON lt Direct power on setting parameter ID gt ON This sets direct power on to ON OFF This sets direct power on to OFF f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET DPON or DPON current direct power on setting is returned as g DPON lt Direct power on setting parameter ID gt For details on other responses refer to the Error List II Description 1 This command is used to set direct power on function to ON or OFF 2 This command functions in the same way as when System setting Direct power on are selected on the menu 3 Direct power on cannot be set to ON when OFF has been selected as the power management setting PMM OFF e 1004 POWER_MANAGEMENT_OFF is returned 4 The current direct power on setting can be obtained us
80. ut OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned if the parameter was set properly For GET KEYLOCK or KEYLOCK current keylocking setting is returned as g KEYLOCK lt Key lock setting parameters ID gt For details on other responses refer to the Error List f Description 1 This command is used to lock the keys so as to restrict the operations performed using the remote control or main unit 2 This command functions in the same way as when System setting Key lock are selected on the menu 3 This command will not affect the emulation function remote control or main unit commands even if the main unit or remote control keys are locked 4 The current key lock setting can be acquired using the applicable GET command GET KEYLOCK Il Example Setting gt KEYLOCK RC This locks the remote control keys lt i OK Reference gt GET KEYLOCK or KEYLOCK This retrieves the key lock state lt g KEYLOCK 0FF Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands LAMP Lamp output setting f Format LAMP lt Lamp output setting parameters ID gt GETLILAMP ALAMP lt Lamp output setting parameters ID gt NORMAL Normal SILENT Silent cooling f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP
81. vised by Approved by Canon Projector WUX10 MarkII User Commands RGBOFFSET RGB offset adjustment f Format RGBOFFSET lt R offset setting Number gt V lt G offset setting Number gt V lt B offset setting Number gt GETLIRGBOFFSET ARGBOFFSET Setting values for lt R G B offset setting Number gt are 60 to 60 f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x z f Response OK is returned if the parameter was set properly For GET RGBOFFSET or RGBOFFSET current RGB offset adjustment values are returned as g RGBOFFSET lt R offset setting Number gt lt G offset setting Number gt lt B offset setting Number gt For details on other responses refer to the Error List II Description 1 This command is used to adjust the offset of the R G and B colors 2 This command functions in the same way as when Image adjustment Color adjustment Offset adjustment are selected on the menu 3 If numerical parameters are outside the range e 0801 INVALID_VALUE is returned 4 This sets the currently selected input signal and image mode 5 The current RGB offset values can be obtained using the GET command GET RGBOFFSET ll Example Setting gt RGBOFFSET 10 11 12 The R offset is set to 10 G offset to 11 and B offset to 12 lt i OK Reference gt GET RGBOFFSET or RGBOFFSET The RGB offset valu
82. ween previous versions of the user commands are as follows lt 1 gt Drive will not stop during zoom or focus Stopped with previous versions lt 2 gt The power management standby status will not change Changed to Power ON Lamp ON with previous versions lt 3 gt The digital zoom will not change Cancelled with previous versions lt 4 gt The presentation timer display will not change Cancelled with previous versions lt 5 gt The BLANK status will not change Cancelled NoShow with previous versions lt 6 gt The FREEZE status will not change Cancelled FREEZE with previous versions lt 7 gt Process under execution will continue Process was interrupted with previous versions 3 The current control mode can be obtained using the GET command GET MODE f Example Mode switch gt REMOTE lt i OK Mode reference gt GET MODE or MODE lt g MODE LOCAL Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands MUTE Mute control f Format MUTE lt Mute control parameter ID gt GETLIMUTE AMUTE lt Mute control parameter ID gt ON This turns off the audio beep sound OFF This returns the audio beep sound to its original setting f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o
83. x z f Response OK is returned if the parameter was set properly For GET MUTE or MUTE current mute setting is returned as g MUTE lt Mute control parameter ID gt For details on other responses refer to the Error List II Description 1 This command is used to set the sound output muting to ON or OFF 2 Mute control enables simultaneous control of the audio and beep sound 3 This command is identical to pressing the MUTE button on the remote control 4 The mute setting is always OFF when the power has just been turned on 5 The volume can be set even when it is on MUTE 6 The current muting status can be acquired using the applicable GET command GET MUTE Example Setting gt MUTE ON This mutes the volume lt i OK Reference gt GET MUTE or MUTE This retrieves the volume state lt g MUTE ON Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon Projector WUX10 MarkII User Commands NOSIG Display screen when no signal setting f Format NOSIG lt Parameters for setting display screen in no signal mode ID gt GETLINOSIG ANOSIG lt Parameters for setting display screen in no signal mode ID gt BLACK Black screen BLUE Blue screen f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response
84. y can be executed during stand by 4 There are no setting commands available Il example Setting None Reference gt GET LMPT This retrieves the lamp time lt g LMPT 12 34 12 hours 34 minutes Commands are indicated by gt and responses are indicated by lt Revision History Date Revised by Approved by Canon MAIN Front panel operation emulation f Format MAINL lt Main unit panel emulation button parameters ID gt Projector WUX10 MarkII User Commands lt Main unit panel emulation button parameters ID gt POWER POWER POWER_OFF POWER button pressed twice MENU MENU AUTO SET AUTOSET INPUT INPUT AUTOPC AUTOPC KEYSTONE KEYSTONE UP UP UP REP Button press start DOWN DOWN DOWN REP Button press start LEFT LEFT LEFT REP Button press start RIGHT RIGHT RIGHT REP Button press start OK OK FOCUS FOCUS ZOOM ZOOM REP Button press end Use the application to adjust the time between pressing of keys f Environment Power Input OFF ON PM D RGB A RGB1 A RGB2 COMP VIDEO HDMI None x o x E f Response OK is returned when the button press request has been acknowledged successfully It does not indicate if the operation for the pressed button was executed properly II Description 1 This emulates the pressing of the front panel buttons for controlling the projector 2 With the emulation of the front panel operations the funct