Home
LRP Pulsar Touch Competition System
Contents
1. 15A 15mV Of For any other pack make sure you select correct settings Chg Mode and Pack Volt and charge with 1C charge rate Leave the settings Cut Temp 40 C for LiPo LiFePo and 55 C for NiMH and Safety Timer untouched C Nominal capacity of the battery E g with a nominal capacity of 4000mAh 4 0Ah the battery can be charged with a max current of 4 0A at 1C REPAIR PROCEDURES LIMITED WARRANTY All products from LRP electronic GmbH hereinafter called LRP are manufactured according to the highest quality standards LRP guarantees this product to be free from defects in materials or workmanship for 90 days non european countris only from the original date of purchase verified by sales receipt This limited warranty doesn t cover defects which are a result of misuse impro per maintenance outside interference or mechanical damage This applies among other things on e Cut off changed original input and or output wires Mechanical damage of the case electronic components or PCB Humidity Water inside the case Soldered on the PCB Charger disassembly by customer Any modification of the charger done by the customer Over temperature failures due to blocking the fan or the cooling slots Reverse polarity at DC output To eliminate all other possibilities or improper handling first check all other components in your model and the trouble shooting guide if available before you send
2. Data View screens for description see section View Last Data CHARGE explanations LiPo LiFe pack voltage The packs rated voltage for LiPo LiFePo batteries must be set according to the packs rating Linear Charge the most common method for NiMH NiCd cells a constant current from beginning to end of charge process the easiest method for charging Step Charge should only be used by experienced racers and only for NiMH cells You may select special charging methods for 1st to 3 step 4 step is fixed to linear Current and Capacity for 1 step should be a low value for current and capacity 1 0A and 0 1Ah is our suggestion 2 step current can be higher we suggest to charge for 25 of batteries nominal capacity with 1C charge VIEW LAST DATA The Pulsar Touch allows to view the stored data of the last 11 processes charge discharge or cycle You can access the same data also during any operation charge discharge etc by pressing the NEXT button this means you can view the stored data from a previous operation during actual use The last operation is always the memory 0 0 000V Charger s input voltage A Voltage at output socket Actual battery temperature VIEW LAST DATA Maximum temperature which battery reached Internal resistance of battery START bde Linear charge II Impulse charges with 1 5x of selected current for short periods 3 step this current you can s
3. an arrow will now be displayed in the upper left corner precisely press the end HR BLUE Pee TE point of the arrow for 2sec an arrow will now be displayed in the lower right corner precisely press the end point of the arrow for 2sec the new touchscreen calibration is stored and you are done CHARGER RESET lt Touch Screen gt lt Touch Screen gt lt CALIBRATION gt lt CALIBRATION gt Please wait Min 0000 0000 Min 0000 0000 Max 0000 0000 Max 0000 0000 a 43150 Competition 14A Powersupply voltage 65821 Charge Wire Harness LiPo 2S Hardcase 65822 Charge Wire Harness LiPo 2S Saddle Hardcase Calibration process 0 000V ne Maske Ser IPE 65835 4 0mm Silver plated connectors 10pcs connect a battery to Pulsar Touch 65845 LiPo Safe Safety Bag 23x30cm ibration Mode 81907 3 3mm Powerwire black 1 0m ontoro Calibration Mong 81908 3 3mm Powerwire blue 1 0m connect a separate voltmeter to the con nection you would like to calibrate compare reading in dispay with reading CALIBRATE BALANCER on your voltmeter adjust voltage on display using up down arrow keys done when voltmeter charger indicate the same value The press ok Calibrate voltage of each cells balancer TROUBLESHOOTING The Pulsar Touch is protected against faults and operator errors by the Multi Protection System Faults Errors are displayed on the LCD screen and they in
4. range 700 1500ms Max pulse width range 1500 2300ms Here the measured RPM when testing together BL Motor RPM Measurement motor RPM measurement can only work by with a speed control will be indicated Very using an optional hall sensor wire splitter LRP will release such an optional small useful to Check your moror and orspetd eonirol device You can of course connect your motor and speed control as in normal use for correct operation to check your speed controls and motors condition but you simply get no RPM in dication the indicated black box is your trigger throttle or steering you can drag it left amp right with your finger and therefore alter the PWM output of the receiver simulator port which Connections make sure you use high quality wire and connectors for maximum accuracy a poor connector or poor wire may create heat and affect the accuracy CONFIG In Config the Pulsar Touch can be customised to your likes adj finish sound C or F etc reset the charger to our factory default setting plus it also allows you to calibrate the voltage readings of output jacket and balancer for maximum precision All chargers come of course calibrated from the factory but due to aging of components this calibration can slightly change over time Additionally the Calibration may be a useful tool at races when LiPo voltage limit is checked and you can therefore adjust your charger to
5. in this product for repair If products are sent in for repair which do operate perfectly we have to charge a service fee ac cording to our pricelist With sending in this product the customer has to advise LRP if the product should be repaired in either case If there is neither a warranty nor guarantee claim the inspection of the product and the repairs if necessary in either case will be charged with a fee at the customers expense according to our price list A proof of purchase including date of purchase needs to be included Otherwise no warranty can be granted For quick repair and return service add your address and detailed description of the malfunction If LRP no longer manufactures a returned defective product and we are unable to service it we shall provide you with a product that has at least the same value from one of the successor series The specifications like weight size and others should be seen as guide values Due to ongoing technical improvements which are done in the interest of the product LRP does not take any responsibility for the accuracy of these specs With LRP 25 Years Warranty products the warranty terms on the LRP 25 Years Warranty card do also apply The legal warranty claims which arose originally when the product was purchased shall remain unaffected LRP Distributor Service e Package your product carefully and include sales receipt and detailed description of malfunction e Send parcel to y
6. 0A 40 C P1 PROFILE NAME lt gt LIFE CHARGE SETUP START CHARGE START LiFe 6 6V 2s 6 0A 40 C Chg Mode Pack volt Current Cut Temp Pl PROFILE NAME lt STEP CHARGE gt SETUP START CHARGE START Current 0 0 0 0 0 0 Capacity 0 0 0 0 0 0 Depending on which profile you have choosen or if you altered the settings under SETUP the designated charge type LINE AR LIPO LIFE or STEP will be indicated on the screen After starting the operation by pressing START button or cell symbol both works the choosen settings will be indicated for you again to avoid incorrect settings for the battery you intend to charge You can cancel the operation and return to main menu by Cut Tem p pressing the X symbol in the upper right corner Autostart This handy feature lets you preselect when you want to start charging your battery with the Pulsar Touch The Autostart Timer is adjustable from 0 99min If you stay in the Autostart Display for longer then CHARGE START 30sec without setting a value the charging process will start automatically Autostart Omin Storage Charge XXXX 0 0X Cw J CO START Storage Charge Never store your batteries completely empty as this will harm them and lower their performance Due to this fact the Pulsar Touch features a Storage charge mode With this function you can set a fixed voltage vor Lixx batteries or fixed capaci
7. 100048 LRP electronic GmbH 2010 SSP TOUCH JeogMmreviri9W USER GUIDE 41000 LRP electronic GmbH Wilhelm Enssle Str 132 134 73630 Remshalden Germany info LRP cc www LRP cc IiE E MI BLUE IS BETTER TECHNICAL DATA Autostart Timer Weight Ti 20 Cycle Mode User Profile Memory Charging Capability LiPo LiFePo 1 4 cells Graphical Touchscreen LCD bisa NiMH NiCd 1 10cells Acoustic Signal Type Finish Melody Mul Protecton Systen DC Input Connection Output Connection Brushless Motor Sensor Port RX Generator ESC Servo Check Discharge LiPo LiFePo 2 0 4 2V cell Voltage Calibration Mode Cut Off Voltage NiMH NiCd 0 1 1 3V cell USB Connection Specifications subject to change without notice n CONNECTIONS Input Connection backside of charger no picture connect your Pulsar Touch to a suitable DC powersupply with 11 15V output voltage and a minimum of 12 0A output current Caution Be careful with correct polarity Output Jacket connect battery to be charged to the 4 0mm jacket using supplied charge wires Caution Be careful with correct polarity Balancer Connector high performance integra ted Lixx balancer for 2S to 4S packs using EHR balancing connector Temperature Sensor optional connect the optional temperature probe to measure battery tempe rature USB Connection connect to PCB using the sup plied USB cable To be used for upcoming firmware updates and PC software
8. 2 indicate 7 You may leave the SETUP menu in A ig n multi Cut Temp 39 C again at any time and the current page menu with more then values will be stored by pressing X one screen You can hop in upper right corner through the pages by pres sing NEXT button Hidden buttons and how to make them visible again To allow more clean screen and more useful information the buttons will be hidden during many active functions Simply touching the screen anywhere will make the buttons visible again After a short while of no use of the screen the buttons will hide again automatically Buttons Hidden Buttons visible again after briefly touching screen anywhere XXXX CHARGE XXXX CHARGE Capacity Current Current voltage voltage Resistance i Resistance Temperature Temperature C Cw Ca EO How to adjust the current on the fly As known by LRP the Pulsar Touch s current charge or discharge can be adjusted during use Touch the current value on the screen the characters will become inverse black background and then use the up down arrow keys to adjust the current to your desired value without interrupting the active process Important This change is not saved in memory the next time you use this function the settings from the memory will be used XXXX CHARGE Touch current characters will be rupee come inverse black background Now use up down arrow keys Voltage to adjust current to your desir
9. Brushless Motor Sensor Port a fantastic fea J ture which allows you to check your brushless motors 7S BL moro EERO sensors and even measure motor rpm In combination En re o ieee with the built in receiver simulator port SENSOR RX Simulator Port you can even check speed controls and servo s for correct function 15A Fuse input fuse for protection only replace with ano ther 15A fuse blue colored housing and no other types as these would not offer protection or correct function BALANGER CONNECTION The Pulsar Touch contains an integrated competition balancer for 2S to 4S LiPo and LiFePo batteries using EHR balancing connector Please refer to drawing also like that on charger for correct polarity basically minus black wire is always on the far right side of the plug as shown on drawing The balancer equalises the cells during charge and balance function which results in higher performance and higher cycle life Caution Avoid incorrect connection as in the worst case this may result in damage to the battery and or charger Connection Example 2S Connection Example 3S Connection Example 4S The Pulsar Touch comes with 5 pre set user profiles but you can also alter those and prepare 5 individual user profiles and even name them as you like This means you can customize 5 personal charge profiles individually and store them for later use The active profile P1 to P5 and it s name is indicated in the he
10. CHARGE Current Pack Volt Cutoff v Cut Temp Ww QED 20 0A 7 4V 2S 3 2V C 50 C P1 PROFILE NAME lt E0 SETUP START P1 CYCLE Direction cC gt D Cycles 1 Chg Delay 10min Dischg Delay 10min Ww QED 2S5 0 000V P1 PROFILE NAME 4 nena gt BALANCE VIEW START P1 BALANCE 1 2 XI 1s 0 000V 3s 0 000V 4s 0 000V Gap 0 000v ninn P1 PROFILE NAME P1 PROFILE NAME 4 gt VIEW LAST DATA TONFIC START SETUP P1 DATA VIEW 1 3 X P1 CONFIG 1 2 X 0 Button Sound ON Finish Sound 15sec Finish Melody 1 LCD Contrast 10 Temp Scale C P1 PROFILE NAME E gt MOTOR ESC SERVO SETUP START MOTOR ESC SERVO Signal Min Signal Max Ww QE The Pulsar Touch can charge LiPo LiFePo NiMH and NiCd batteriesand incorporates the designated charge algorithms for each particular cell type for best performance reliability and safety with up to 12 0A charge current Please always follow your battery manufacturers recommendations for maximum allowed charge current and make sure you always use the correct Chg Mode setting for the battery you want to charge as wrong setting may result in damage to the battery P1 PROFILE NAME lt LINEAR CHARGE gt SETUP START CHARGE START C q 7 Pack Volt Current DPeak Trickle P1 PROFILE NAME lt LIPO CHARGE gt SETUP START CHARGE START LiPo Chg Mode 7 4V 2s Pack Volt Current Cut Temp 6
11. V graphical indication of dif Select required sequence v45 0 000V IEEE C D Charge followed by discharging D C Discharge followed by charging Gap 0 000v Pi E D C C Initial Discharge followed by charge discharge Direction Cycles 01l Number of Cycles 1 to 10 P1 ZENNA E E E O T 0g in eA Te Pause time before charging after discharge 1 90min 1s 0 0mo each cell and graphical in g y 2s 0 0mo dication of difference 35 0 0m aw AE 4s 0 0mo Pause time before discharging after charge 1 90min MOTOR ESC SERVO CHECK The Pulsar Touch incorporates as the first charger a fantastic feature which allows you to check your brushless motors sensors and even measure motor rpm In combination with the built in receiver simulator port you can even check speed controls for correct function The receiver simulator port also allows the check of servo s Connection Servo Test Connection BL Motor Sensor check Connection BL Speedo amp Motor Check incl RPM BL MOTOR SERVO SENSOR JESC BL MOTON gt SERVO connect servo direct to connec connect a brushless motor direct to the BL Mo motor RPM measurement can only work by tor port be careful with correct tor Sensor Port using a standard brushless motor using an optional hall sensor wire splitter polarity black minus must be on sensor wire You can of course connect your motor and f right side The sensor check is simple as the sensors get spee
12. adline of the main menu 3S LiPo 2A 2A Temp Scale Tip You can always reset to above factory default settings under CONFIG function see separate box Dear Customer thank you for your trust in this LRP product By purchasing aLRP Pulsar Touch you have chosen a high performance product which has the latest technology incorporated including the following High Tech features e Professional Multi Function System Charge Discharge Cycle Balance Motor ESC Servo Check e up to 12 0A Charge Current e up to 20 0A discharge current 35A Pulse Discharge e LiPo LiFePo NiMH NiCd e Integrated Balancer for 2S 4S Lixx batteries e Touchscreen Graphics LCD Display e 5 User Profile Memories e 25 Year Warranty e Multi Protection System Please read the following instructions carefully before you start using your charger This user guide contains important notes for the installation the safety the use and the maintenance of this product Thus protecting yourself and avoid damages of the product Proceed according to the user guide in order to understand your charger better Please take your time as you will have much more joy with your product if you know it exactly This user manual shall be kept in a safe place If another customer is using this product this manual has to be handed out together with it TOUCHSCREEN USAGE As known from LRP the programme structure is logical and intuitive therefore most users can
13. age voltage and internal resistance By discharging your battery pack on the Pulsar Touch after use you obtain vital information about remaining capacity for optimizing your motor or gear ratio for the next run This also maintains your battery packs in good condition P1 PROFILE NAME T Discharge screen Time elapsed since start of discharge LC gt DISCHARGE START DISCHARGE Discharge capcacity Current 20 0A CHECK STATUS Capacity setup __ __START Pack Volt 7 4v 2s Current i Discharge current i Cutoff v 3 2V BATTERY a 0k o gt Voltage Actual pack voltage DISCHARGE 2D Cut Temp 55 C Connection Avg volt Resistance Average voltage of your pack during discharging the choosen settings will be your charger checks if all NEXT STOP indicated to avoid incorrect connections and the battery NEXT wv a fay Internal resistance of your pack settings for the battery you itself are ok and if discharge want to discharge process can be started Cancel the operation by pres sing X in upper right corner DISCHARGE explanations DISCHARGE further screens Discharge Current The discharge current can be set from 0 1 20 0A and 35A pulse If not otherwise specified by the During running discharge process there is additional information available by pressing NEXT button you may access those battery manufacturer the max discharge current can be set to 20 0A for racing cells Sub C size in L
14. d control as in normal use to check your connect speed control direct to measured while you rotate the shaft by hand speed controls and motors condition but you connector port be careful with simply get no RPM indication correct polarity black minus ply g ace must be on right side MOTOR ESG SERVO CHECK explanations Battery Connection if you want to check full function of your motor and or speed control you need to connect your regular battery to the speed control as the 4 a gt Pulsar Touch doesn t provide the high power to the speed control but only the si selected pulse width values gnals MOTOR ESC SERVO P1 PROFILE NAME C START J Speed Control Setup you need to make your regular speed control setup so the speed control learns the Pulsar Touch s neutral full throttle and full brake points if you want to check your speed control Speed Control On Off Switch some speed controls need to have on off switch in Off position when connecting to Pulsar Touch as it supplies it s own BEC So please make sure you test with switch in OFF position first and if all works as it should this is fine for your speed control If your speed control is dark when in off position you should try on ON positino crore ESC SERVO M OK indicates that the hall sensors inside your connected brushless motor work fine After connecting your motor to the sensor port you can rotate the shaft by hand Min pulse width
15. ed Resistance value Temperature How to change the profile names Keep headline pressed in main menu this brings you into the function to alter the active profiles name You can change the name in several ways pick the method you feel most Pl PROFILE NAME i comfortable with 1 straight indicate write by touching the characters one after the other 2 hop through the characters by using the right key and confirm the se lected character by using the V key lt 4 LINEAR CHARGE gt You confirm and leave this setting by either pressing X symbol in upper right corner or by pressing OK key Pl PROFILE NAME indicates which aie ae head indicates new character Sl h d ee eae ABCDEFHTIKLMNOPIGR Yourevesclect STUVWXYZabcdefghi jk Imnopqrstuvwxyz 0123456789 _ c0 OO Lx PROGRAMME STRUCTURE SETUP After powering up your Pulsar Touch you are in the main menu where you can scroll through all functions Charge Discharge Cycle Balance View Last Data Config Motor ESC Servo and either start the required process by press START button or access the particular functions setup by pressing SETUP All the functions and our recommendations are explained in detail on next pages P1 PROFILE NAME lt 4 LINEAR CHARGE gt SETUP START P1 CHARGE 1 2 X P1 CHARGE Cut Temp Ew QED CHARGE PROCESS P1 PROFILE NAME oa DISCHARGE SETUP START P1 DIS
16. emperature Sen 2 sensor defective sor disconnected wrong setting for battery you Internal error re start your char ERROR connected ERROR ger and if needed reset to factory OUTPUT contact wiring problem INTERNAL defaults and calibrate output Voltage to low defective battery Calibration balancer again Data damaged charger to hot let charger cool ERROR down INTERNAL Temperature Overload 15A Fuse lf the display is dark at power up you should check for correct wiring first and then should also check the input fuse input fuse for protection only replace with another 15A fuse blue coloured housing and no other types as these would not offer protection or correct function RECOMMENDED CHARGE CURRENTS Important always follow the battery manufacturers recommendations first our own recommen dation should only be seen as a guideline for the most common battery packs Ba Ty Mode Volt LiPo f 7 4V 2S 10 0A JIV 18 8 0A AV 28 2 5A 11 1V 3S 2 5A 6 6V 2S 8 0A 7 4V 28 2 0A 1 5A iY Chg Pack Current DPeak Trickle LiPo LiPo LiPo LiFe LiPo LiFe 6 6V 2S LiPo 7 4V 2S 5 0A LiPo 3S 20 35C 1 10 Sub Csize f LiPo 11 1V 2S 50A NiMH 1 10 Sportpack 2000 3800mAh f Linear 40A 20mV Off NiMH 1 10 Sportpack gt 3800mAh f Linear 50A 20mV Off NiMH AA Mignon TX Pack 2500mAh f Linear 10A 30mV Off NiMH RXPack 1500mAh f Linear
17. et fairly high up to 2C charge rate only charge to 75 of batteries nominal capacity with this rate 4 step use lower current again to end of charge for accurate peak detection and best performace Set ca I Reflex charges pacity for this step to 110 of nominal capacity with short discharge spikes every few se conds ren IE Same settings on the second screen of Step Char ging as for normal linear charge of NiMH NiCd cells using up down arrow keys allows you to scroll through the stored 11 cycle data s number is indicated in headline 0 10 Charge Algorithms the Pulsar Touch contains high accuracy charge profiles for each type of battery make sure you always use the correct Chg Mode setting for the battery you want to charge as wrong setting may result in damage to the battery LiPo LiFePo Chg 000m00s 0 000V 000 0A charge time Dischg peak voltage at end of charge discharge time average voltage during discharging discharged capacity gt charging using the CC CV charging method With this charging method the battery gets charged with a constant current first As soon as the battery voltage reaches the max allowed charging voltage per cell for example LiPo 4 2V and LiFePo 3 7V the charger automatically reduces the charging current till the battery is fully charged charge capacity NiMH NiCd charging with constant current Linear or Step Mode delta peak detection This
18. familiarise with the usage and functions without even reading the manual but it is obviously strongly recommended to read this manual in order to achieve maximum performance from the PulsarTouch and make best use of all of it s great features You can either use your finger or the included plastic pen to use the touchscreen make sure you only use very light pressure to activate the functions as too high pressure may damage the display Press briefly to jump to next profile P1 gt P2 gt P3 gt P4 gt P5 gt P1 Keep pressed to enter Profile Name menu which allows renaming of the choosen profile see below press arrow to scroll to Pl PROFILE NAME press arrow to scroll to the the leftt e g previ tight e g next function ous function press SETUP to change the settings of The logo LINEAR CHARGE in this case indicates this function in this case the function is which function is pre selected LINEAR CHARGE Press START or center symbol to start the function Adjusting the settings and hoping through multi page menu P1 CHARGE 1 2 xX after accessing the menu with SE TUP you can select the value which you may access that value directly by pressing with your finger or pen or by pressing SET button Once this line is shown inversed black background you can then change that value using the up down PL CHARGE DART OE as 1 2 and 2
19. iPo LiFe and NiMH The available screens are you jump to next by pressing NEXT again technology l Voltage of each cell in pack if balancer is used for description see section Balancer However lower grade cells and receiver transmitter battery packs you should use a lower the discharge current and should Internal resistance of each cell in pack if balancer is used for description see section Balancer follow your battery manufacturer s recommmendations Data View screens for description see section View Last Data Cut Off Voltage The cut off voltage can be adjusted for all types and numbers of cells We recommend a cut off voltage of 0 9V cell with NiIMH NiCd batteries and 3 2V cell with LiPo batteries As an example 5 4V for a 6 cell NiMH NiCd pack 6 4V for a 2S LiPo pack Temperature by using the optional temperature sensor you can set a maximum temperature which the battery is not This fully automatic cycling matching function allows you to determine the actual performance of your packs Battery packs allowed to reach during discharging If battery reaches that temperature the discharge process will be stopped change during their life span or different batteries may vary slightly Use the Pulsar Touch to detect the actual quality of your pack this prevents nasty surprises i The Cycle function can of course be used for all types of cells Connections make sure you use high qua
20. is the most GRAPH VIEW 3 3 X popular charging method for NiMH NiCd batteries in competition EES Op UODO O 00N Grey here you can view the charge or discharge curve of the selected data and can even select different curves zoom into the curve etc as explained below this is only useful for expe rienced users Charge Current The charge current can be set from 0 1 to 12 0A for racing cells Sub C size in LiPo LiFe and NiMH technology you can usually use 1 5C charge rate e g 7 5A for a 5000mAh pack with no problem However for lower grade cells and receiver transmitter battery packs you should use a lower charge current and should follow your battery manufacturer s recommmendations 0 000vc 0 000V A Ox Delta Peak With NiMH NiCd batteries you only obtain the optimum battery performance by slightly overcharging the battery In real terms it will not be overcharged but charged to an optimum level The battery voltage drops at the end of the charging process delta The size of the drop delta peak is adjustable in the range between 1 200mV The higher the value the hotter the battery will be at the end of the charge We recommend to start with the works default settings Note The adjustable Delta Peak value applies to the whole battery pack and not to one single cell you can display three different parameters as a curve and you hop through them by pressing circled area briefly V voltage current T temperatu
21. lity wire and connectors for maximum accuracy a poor connector or poor wire may create heat and affect the accuracy The Cycle mode uses the charge and discharge values of the currently selected programm stored under SETUP and is of course fully adjustable in regards of sequence and pause delay times between the different operations of the cycle Discharge Wattage limitation the discharge wattage is limited to 150W Watts Voltage x Current e g for function as well See 7 4Vx20A 148W this means packs with higher then 7 4V can not be discharged with 20A but the charger will automati At the end of the process the packs performance will be indicated to you by informing you about cally set the highest possible current by itself during discharging Discharge Capacity in mAh Discharge Time Average Voltage during discharging Internal resistance BALANCE P1 PROFILE NAME You can simply balance your 2S to 4S LiPo and LiFePo batteries using the integrated balancer The Pulsar Touch indicates voltage and internal resistance for each cell in your pack Automatic Cycle as adjusted in Setup the screens look identical e JU starr sfeceeeeee gt as during regular charge or discharge operation but additional text 1 1 2 reminds you that you are in Cycle mode P BALANCE x lt q gue gt 1s 0 000V indication of voltage of each cell gap between BALANCE a2S 0 000V the worst two cells and avons 35 0 000
22. our national LRP distributor e Distributor repairs or exchanges the product e Shipment back to you usually by COD cash on delivery but this is subject to your national LRP distributor s general policy The crossed out wheeled bin means that within the European Union the product must be taken to seperate collection at the product end of life Do not dispose of these products as unsorted municipal waste
23. re VIEW LIA3J x press curve to activate measurement line which can be moved with up down buttons Trickle Charge This current which flows after delta peak cutoff is adjustable from 0 0 0 5A to achieve the highest possible voltage for NiCd cells Set this function to Off for NiMH cells Alternatively you can use the Auto Trickle Function for an automatic Trickle Charge setup increase or decrease the marked inversed black background value Connections make sure you use high quality wire and connectors for maximum accuracy a poor connector or poor wire may create heat and affect the accuracy Zoom Level of X Axis Time horizontal Automatic Zoom Manual Zoom middle point of Y axis Temperature Sensor there is an optional temperature sensor available so you can monitor the battery temperature during charging and discharging As it s normally not required for most users we didn t include it with the charger as it would have only increased cost for everyone When no sensor is connected display will indicate 0 0 C Resolution of Y axis voltage 1x to 43x current or temperature if A it s on automatic setting DISCHARGE The adjustable high performance discharge circuit 0 1 to 20 0A 35A Pulse discharge can be used for 1 14 cell NiMH NiCd and 1 4 cell Lixx packs The Pulsar Touch informs you about all the data relating to the battery pack e g discharge time capacity aver
24. terrupt the active process to protect the unit and the battery Error Messages input voltage too low lt 11 0V discharge level of cells within ERROR or too high gt 15 0V A ERROR pack to different INPUT powersupplies current to low BALANCER bad contact at balancer Input Failure for selected charge current Cells connected defective battery must be 11 15v contact wiring problem to different no battery connected wrong setting for battery you ERROR bad contact on output ERROR connected OUTPUT defective battery BALANCER No conection cell voltage to high wrong setting for battery you ERROR ERROR connected OUTPUT BALANCER contact wiring problem Battery connected cell voltage defective battery with wrong polarity to low wrong battery connection contact wiring problem Caution only if optional tempe ERROR _ defective battery AN ERROR rature sensor is connected OUTPUT BATTERY 1 battery to cold Short Circuit Temperature 2 contact wiring problem to low contact wiring problem Caution only if optional tempe ERROR _ defective battery ERROR rature sensor is connected OUTPUT BATTERY 1 battery to warm Loss of Temperature 2 contact wiring problem connection to high wrong setting for battery you Caution only if optional tempe AN ERROR connected AN ERROR rature sensor is connected OUTPUT SENSOR 1 contact wiring problem voltage to high T
25. the multimeter used in technical inspection in the best way P1 PROFILE NAME lt CONFIG P1 CONFIG 1 2 X Button Sound On On or Off Finish Sound 15sec Off 5sec 15sec Finish Melody 1 1 5 different melodies LCD Contrast 10 depending on light condition contrast may be altered Temp Scale C Se or F ne OW Ga Reset s your profile settings and profile names to our factory P1 CONFIG defaults please see section Factory Defaults for values Factory Reset FACTORY DEFAULTS X Calibrate Output Calibrate Balancer t Are you sure you INITIALIZATION hte want to Reset Key JED XK FACTORY defaults USEFUL ACCESSORIES LRP offers a comprehensive line of accessories as well as particular spare and optional items Here you find an overview for a full picture please visit our website at www Irp cc TOUCHSCREEN CALIBRATION If you should ever recognise a big difference between the LCD display and your actual touch point you may need to re calibrate the positioning of the touchscreen How to re calibrate the touchscreen 1 with no power connected to the charger keep the touchscreen pressed and then connect the power to the charger keep the screen pressed the charger will beep to indicate the charger is con nected to power first and if you keep the screen pressed it will make short beeps At this time detach your hand from the screen
26. ty for Nixx batteries value and the battery will be partially charged or discharged in case of Lixx exactly to this level Thus you can always perfectly prepare your battery for storage if you want to store them over a longer period of time Our recommendations NiMH NiCd 50 of nominal capacity LiPo 3 8V cell LiFePo 3 4V cell Chg Mode Time elapsed since start of charge AUTOSTART TIMER XXXX CHARGE Capacity Current Voltage Resistance Temperature 0 0 pec 45 E23 Charge capcacity Time to Start 00m0Os CHECK STATUS Charge current adjustable during charging BATTERY Connection Actual pack voltage STOP START time until charging starts you can skip and start immediate ly by pressing START or you can return to the main menu by pressing STOP Internal resistance of your pack during charging your charger checks if all con nections and the battery itself are ok and if charge process can be started Temperature of your pack optional with sensor CHARGE further screens During running charge process there is additional information available by pressing NEXT button you may access those The available screens are you jump to next by pressing NEXT again Voltage of each cell in pack if balancer is used for description see section Balancer Internal resistance of each cell in pack if balancer is used for description see section Balancer
Download Pdf Manuals
Related Search
Related Contents
Samsung AZ09F1TEA Manual de Usuario 区点コード一覧 Si7013EVB-UDP/Si7013EVB-UDP-F960 User's Guide Invacare ® Orion SERVICE ANLEITUNG Improving the Operation of Multi Relazione finale - Comune di Ferno bluetooth wireless stereo speaker user manual smps-625 Copyright © All rights reserved.
Failed to retrieve file