Home
Tripp Lite ECO650LCD uninterruptible power supply (UPS)
Contents
1. 6 12 21 2010 11 47 35 AM
2. Owner s Manual lt gt ECO UPS Systems with LCD Models ECOG50LCD ECO850LCD Not suitable for mobile applications d Esi HH Ses Gahi IE RUNTIME t The ECO Energy Saving Feature allows your UPS to save energy by automatically turning off designated outlets when your computer is off or in standby mode When the UPS detects that your computer has been turned off or in standby mode for 3 minutes it will turn off the outlets marked ECO The 3 minute delay ensures that the outlets remain powered during a reboot momentary cable disconnection or similar transitory event N Important Safety Instructions Basic Operation UPS On Off LCD Features Display Power Conditions ECO Energy Saving Feature Enable Disable Alarm LCD Brightness Self test Error Messages Features Storage and Service Warranty Registration Espa ol Fran ais NOP KR AA WW WWW W a G9 TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2010 Tripp Lite All rights reserved 201010198 indb 1 12 21 2010 11 47 34 AM Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation operation and storage of this product Failure to heed these warnings may affect the warranty UPS Location Warnings e Install your UPS indoors away from excess moisture or heat conductive contaminants dus
3. arts inside e Batteries can present a risk of electrical shock and burn from high short circuit current Observe proper precautions Do not dispose of the batteries in a fire Do not open the UPS or batteries Do not short or bridge the battery terminals with any object Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles There are no user serviceable parts inside the UPS Battery replacement should be performed only by authorized service personnel using the same number and type of batteries Sealed Lead Acid The batteries are recyclable Refer to your local codes for disposal requirements or visit www tripplite com UPSbatteryrecycling for recycling information Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges R B C Visit Tripp Lite on the Web at www tripplite com support battery index cfm to locate the specific replacement battery for your UPS e Do not attempt to add external batteries to the UPS 2 201010198 indb 2 12 21 2010 11 47 34 AM Basic Operation UPS ON OFF e Plug the UPS into a grounded outlet e Turn the UPS on Press and hold the Q button for 2 seconds The UPS alarm will beep once briefly after 2 seconds have passed e Plug equipment into the UPS Select outlets will provide battery backup and surge protection connect your computer monitor and other critical devices here Select outlets will provide surge protection only connect you
4. ated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make connections themselves but should contact the appropriate electric inspection authority or electrician aS appropriate Note on Labeling Two symbols are used on the label V AC Voltage V x DC Voltage Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marking name or model number of the product Tripp Lite follows a policy of continuous improvement Product specifications are subject to change without notice TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 6 201010198 933071 EN 201010198 indb
5. computer Connect nonessential equipment to the ECO outlets marked ECO on your UPS system Make sure that any devices connected to the ECO outlets can be turned off without interrupting your Internet connection local network or other essential services While your UPS is turned on and operating normally from utility power tap the button repeatedly to advance the LCD display to the screen marked ECO Use the button to enable the ECO function Enable Disable Alarm Tap the A button repeatedly to advance to the LCD display featuring the icon Press the button to select enable or disable alarm mode settings 201010198 indb 3 12 21 2010 11 47 34 AM Basic Operation continued LCD Brightness Tap the A button repeatedly to advance to the LCD Brightness display marked LCD Press the GP button to select Medium Backlight default High Backlight or Dim Backlight Note After 2 minutes of inactivity the backlight will revert to the Dim setting until a button is pressed Self test Tap the 4 button repeatedly to advance to the display Press the button to initiate the test The test will last approximately 10 seconds as the UPS switches to battery to test the capacity with a load Upon completion of the test the display will indicate PAS or BAD pass or bad for 20 seconds then return to the home screen Connected equipment can remain on during the test Do not unplug your UPS this will remove safe electrical groun
6. ding Error Messages In the event that the UPS battery requires replacement the icon will flash as well as the Ml icon If there is an overload the H amp G EN and EA icons will flash simultaneously along with a numeric read out of the load percentage UPS Features ON OFF MODE Button Press and hold for 2 seconds to turn on the MODE UPS and 2 5 seconds to turn the UPS off When the UPS is on tap this button repeatedly to advance through LCD display screens MUTE SELECT Button Use this button to toggle selection options for self test enable disable alarm LCD brightness and ECO feature This button can also be used to temporarily mute an active alarm by briefly pressing it Tel DSL Line Protection Jacks These jacks protect equipment against surges over a single phone line Connecting your equipment to these jacks is optional Your UPS will work properly without this connection USB Communications This port connects your UPS system to any computer enabling PowerAlert Software to automatically save open files and perform unattended shutdown in the event of a power failure and is also required to utilize the ECO feature Use with included cable featuring a USB connector to connect to your computer s port and the RJ45 connector to connect to the UPS system port Connecting your equipment to this port is optional Your UPS will work properly without this connection Battery Backup Protected Surge Protected Outlets Pro
7. er or an experienced radio television technician for help The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of the FCC rules Operation is subject to the following 2 conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may Cause undesired operation Equipment Attachment Limitations models with the Industry Canada label in Canada only NOTICE The Industry Canada label identifies certified equipment This certification means that the equipment meets the telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements Document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that the compliance with the above conditions might not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative design
8. r printer and other nonessential devices here Turn the UPS off Press and hold the button for 2 5 seconds The UPS alarm will beep once after 2 5 seconds have passed Your UPS is designed to support electronic equipment only You will overload the UPS if the total VA ratings for all the equipment you connect to the Battery Surge and Noise Protected outlets exceeds the UPS s Output Capacity To estimate your equipment s power requirements look on the nameplates If the equipment is listed in amps multiply the number of amps by 120 to determine VA Example 1 amp x 120 120 VA Your UPS is fully loaded when the display indicates 100 load LCD Features Tap the button to advance from one display to the next Use the button to toggle settings for ECO Alarm LCD Brightness and Self test functions When the preferred setting has been selected continue by pressing the button If the screen is idle for 20 seconds the LCD will return to the home screen retaining the last selected settings Display Power Conditions Use the button to advance through power conditions e Voltage In LLL a E _ e Voltage Out o our n e Estimated Runtime in minutes a E our ne eno ECO TEST BATT e Load Wattage RUNTIME Pama Tam ae e Battery Capacity Display measurement represents battery backup protected outlets only ECO Energy Saving Feature Use the included USB cable to connect your UPS to your
9. t from the network until the problem has been corrected or you are sure the equipment is not malfunctioning There are no repairs that can be made by the customer to the Modem Fax Protection This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state tariffs Contact your state public utility commission or corporation commission for information FCC Radio TV Interference Notice U S only Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference using one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and the receiver connect the equipment into an outlet on a circuit different from that which the receiver is connected consult the deal
10. t have transportation charges prepaid Mark the RMA number on the outside of the package If the product is within its warranty period enclose a copy of your sales receipt Return the product for service using an insured carrier to the address given to you when you request the RMA 5 201010198 indb 5 12 21 2010 11 47 35 AM Warranty Registration Visit www tripplite com warranty today to register the warranty for your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details FCC Part 68 Notice United States Only If your Modem Fax Protection causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance If advance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipment operations or procedures that could affect the proper operation of your equipment If it does you will be given advance notice to give you an opportunity to maintain uninterrupted service If you experience trouble with this equipment s Modem Fax Protection please visit www tripplite com support for repair warranty information The telephone company may ask you to disconnect this equipmen
11. t or direct sunlight e For best performance keep the indoor temperature between 32 F and 104 F 0 C and 40 C e Leave adequate space around all sides of the UPS for proper ventilation UPS Connection Warnings e Connect your UPS directly to a properly grounded AC power outlet Do not plug the UPS into itself this will damage the UPS e Do not modify the UPS s plug and do not use an adapter that would eliminate the UPS s ground connection e Do not use extension cords to connect the UPS to an AC outlet Your warranty will be voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to an outlet e f the UPS receives power from a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings e Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide e Do not connect surge suppressors or extension cords to the output of your UPS This might damage the UPS and will void the surge suppressor and UPS warranties Battery Warnings e Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable p
12. very three months Plug the UPS into a live AC outlet turn it on by pressing and holding the 4 button for 2 seconds and allow the batteries to recharge for 4 to 6 hours If you leave your UPS batteries discharged for a long period of time they will suffer a permanent loss of capacity Service A variety of Extended Warranty and On Site Service Programs are available from Tripp Lite For more information on service visit www tripplite com support Before returning your product for service follow these steps 1 Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading of the instructions 2 If the problem continues do not contact or return the product to the dealer Instead visit www tripplite com support 3 If the problem requires service visit www tripplite com support and click the Product Returns link From here you can request a Returned Material Authorization RMA number which is required for service This simple on line form will ask for your unit s model and serial numbers along with other general purchaser information The RMA number along with shipping instructions will be emailed to you Any damages direct indirect special or consequential to the product incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty Products shipped to Tripp Lite or an authorized Tripp Lite service center mus
13. vide both battery backup and surge protection Plug your computer monitor and other critical equipment into these outlets Note Do not plug laser printers into these outlets 4 201010198 indb 4 12 21 2010 11 47 35 AM Features continued Surge Only Protected Outlets Provide surge and line noise protection not battery backup or the ECO feature Plug equipment that does not require battery backup during a utility power failure into these outlets such as a printer scanner or fax machine Surge Only Protected ECO Outlets These outlets provide surge and noise protection not battery backup Your UPS system can save energy by automatically turning off these outlets when it detects that your computer is turned off or in standby mode Make sure that any device connected to the ECO outlets can be turned off without interrupting your Internet connection local network or other essential services Resettable Input Circuit Breaker Protects your electrical circuit from overcurrent draw from the UPS load If this breaker trips remove some of the load then reset it by pressing it in Storage and Service Storage To avoid battery drain all connected equipment should be turned off and disconnected from the UPS Press and hold the 4 button for 2 5 seconds Your UPS will be completely turned off deactivated and will be ready for storage If you plan on storing your UPS for an extended period fully recharge the UPS batteries e
Download Pdf Manuals
Related Search
Related Contents
MooreCo 27670 Samsung SGH-E818 用戶手冊 スイッチング電圧レギュレーターSVR3−7V 取扱説明書 DUCATISPORTTOURING CodeWarrior U-Boot Debugging Targus THZ16003EU Kowa KE811CT Switch User Manual Copyright © All rights reserved.
Failed to retrieve file