Home
iogear GCS1716TAA KVM switch
Contents
1. 5 seconds All Off On PC Compatible Upper left corner 3 seconds Port Number Port Name F Full For all Users on all ports Disabled 54 Firmware Upgrade Note In order to perform a firmware upgrade you need to use a computer that s not connected to the KVM Step 1 Connect the provided firmware upgrade cable to the firmware upgrade port of the KVM and the serial port of your computer Connect power adapter to your power outlet and the KVM Step 2 Go to www iogear com to download the latest available firmware or the specific firmware that you wish to upgrade to 55 Step 3 Please make sure all the computers that are connected to the KVM are completely shutdown Then Invoke Firmware Upgrade Mode Please refer to OSD Operation section Step 4 Extract the file with WinRAR or compatible software Then double click on the execute file to begin with the Firmware Upgrade Utility Step 5 Read the License Agreement and click Agree then click Next if you wish to continue with the firmware upgrade Otherwise click Cancel to exit Firmware Upgrade Utility devices or ii use of the Product over such network and make backup copies of the Product RESTRICTIONS ou agree not to modify adapt translate reverse engineer recompile disassemble or otherwise attempt to discover the source code of the Product or create derivative works based on the Product or remove any propri
2. Installation e gt 8 16 Port USB PS 2 Combo KVMP Switch GCS1808 GCS1716 PART NO M1102 M1074 2009 IOGEAR All Rights Reserved Part No M1102 M1074 IOGEAR the IOGEAR logo MiniView VSE are trademarks or registered trademarks of IOGEAR Inc Microsoft and Windows are registered trademarks of Microsoft Corporation IBM is a registered trademark of International Business Machines Inc Macintosh G3 G4 and iMac are registered trademarks of Apple Computer Inc IOGEAR makes no warranty of any kind with regards to the information presented in this document All information furnished here is for informational purposes only and is subject to change without notice IOGEAR Inc assumes no responsibility for any inaccuracies or errors that may appear in this document Package Contents 1x 8 16 Port USB PS 2 Combo KVMP Switch 1x PS 2 KVM Cable 1x USB KVM Cable 1x Console Cable 1x Cascade Cable 1x Firmware Upgrade Cable 1x Rack Mount Kit 1 Set 1x Grounding Wire 1x Foot Pad Set 4 Pads 1x Power Adapter 1x Installation Guide 1x Warranty Card System Requirements Console e A display with an VGA HDB 15 input e A USB or PS 2 Keyboard and Mouse Computers e A video output with an VGA HDB 15 female connector e Open USB port or PS 2 keyboard and mouse ports Table of Contents Package Contents System Requirements GCS1808 Overview GCS1716 Overview Foot Pad Set Inst
3. keys If there are more list entries than what appears on the main screen the screen will scroll To activate a port double click it or move the highlight bar to it then press Enter 27 e After executing any action you automatically go back to the menu one level above OSD Function There are eight options showing on top of the OSD screen Simply click the function key on the top of the screen or press the specific function key on the keyboard on access the specific function F1 GOTO F1 GOTO This function is to let you switch to a specific port via port ID or port s name Enter 1 to choose from Port Name and 2 to choose from Port Number in the yellow box locating in the bottom of the pink bar If 1 was chosen then type in the port s name that you want to go to and then press Enter You can also move the red highlight bar to the specific port that you want to go to and press Enter 28 F2 LIST If 2 was chosen then you can go to a specific port by entering the port ID You can also move the red highlight bar to the specific port that you want to go to and press Enter F2 LIST This function allows you to choose a way that you wish to list the ports in the OSD display on the main screen Simply move the red highlight bar to the option that you wish to choose and press Enter You will see the hand symbol will be point ing at the option that you chose then simply press Esc
4. port switching hotkey sequence between Scroll Lock Scroll Lock and Ctrl Ctrl Set keyboard operating platform to PC compatible Set keyboard operating platform to Mac compatible Set keyboard operating platform to Sun compatible Perform keyboard Mouse reset on the port that has KVM focus Note You can also press and hold Port 1 and Port 2 front panel push button to perform keyboard mouse reset 50 Invoke HSM then press Invoke HSM then press gt Invoke HSM then press b Invoke HSM then press X Y Enter Invoke HSM then press r Enter Invoke HSM then press a Enter or Invoke HSM then press q Enter Invokes Skip mode and skips from the current port to the first accessible port previous to it Invokes Skip mode and skips from the current port to the next accessible port Toggle hotkey beepers on or off Switches KVM focus to the computer that is connected to Port X in the 1st Level and Port Y in the 2nd Level Note If you only have a single level installation simply ignore the Y interval Restore default settings Administrator ONLY Invoke Auto Scan Mode Note Auto Scan can be paused and resume by pressing p or by a single left click on the mouse Note X and Y are intervals from 1 8 for GCS1808 and 1 16 for GCS1716 When you enter please make sure you enter each of them as a 2 digit number for example you would need to type 01 for port 1 51 Ma
5. ports that have been powered on Scan only the ports that have been set as quick view ports and they have been powered on 34 Screen Blanker This function allows you to set the time interval to have the KVM goes to a black screen Simply en ter the number between O to 30 and press Enter then press Esc to exit from this function 4 UP J PGUP F SELECT v DOWN 43 PGDOWN STRATOR SET SUSPEND ACTIVATE TIME OSD HOTKEY PORT ID DISPLAY POSITION PORT ID DISPLAY DURATION PORT ID DISPLAY MODE SCAN DURATION 9 SEC SCAN SKIP MODE HOTKEY COMMAND MODE CON amp 35 Hotkey Command Mode This function allows you to enable or disable the hotkey commands Simply press Y for yes and N for no Then press Esc to exit from this function EBSCHEXLT 4 UP J PGUP NTER SELECT 3 DOWN 3 PGDOWN DMINISTRATOR SET HOTKEY COMMAND MODE a A OSD HOTKEY PORT ID DISPLAY POSITION PORT ID DISPLAY DURATION PORT ID DISPLAY MODE SCAN DURATION 5 SEC SCAN SKIP MODE SCREEN BLANKER OFF HOTKEY ACTIVATED Y N H Hotkey OSD Language This function allows you to set the hotkey This function allows you to choose the OSD sequence that you wish to use to trigger hotkeys language between English Deutsch Japanese commands Simply move the red high light bar to Simplified Chinese and Traditional Chinese Simply choose the sequence that you wish to use and move the red high light bar to the language that press Enter T
6. reset itself Unplug the power from the KVM after the KVM is reset Step 5 Slide the Firmware Upgrade Recovery Switch back to the Normal position slide to the left Then connect power adapter back to the KVM FIW UPGRADE NORMAL RECOVER Final Step Now the KVM is ready to function again So you simply reconnect all your computers and console back to the KVM and begin using the KVM Restore Factory Default Settings This restore will change all settings back to default This will also have administrator and all user accounts removed from the KVM All port names and setting will also be removed In other words everything will be changed as if it is a brand new unit Step 1 Unplug the DC connector from the KVM then remove the housing of the KVM Step 2 Using a jumper cap short the jumper on the main board labeled J17 60 Step 3 Now plug the DC connector back into the DC jack from the KVM This will restore the KVM with factory default firmware Step 4 A message will appear on the monitor as below 61 Step 5 Unplug DC connector from the KVM then remove the jumper and screw the housing back on the KVM Final Step Plug DC connector back into the KVM then the KVM will be ready for usage again Federal Communications Commission FCC Statement 19 21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user
7. s authority to operate the equipment 15 105 b his equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 ofthe FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 62 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOL LOWING TWO CONDITIONS 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device FCC RF Radiation Exposure Statement This equipment complies wi
8. to exit the function QUICK VIEW POWERED ON QUICK VIEW POWERED ON Function All Quick View Powered ON Quick View Pow ered ON Description List out all ports that the administrator has set as accessible for the current logged in user List out only the ports that have been set as quick view ports List out only the ports that have been powered on List out only the ports that have been set as quick view ports and they have been powered on 30 F3 SET F3 SET There are 10 different settings within the SET section which they are as follow OSD Hotkey Port ID Display Position Port ID Display Duration Port ID Display Mode Scan Duration Scan Skip Mode Screen Blanker Hotkey Command Mode Hotkey OSD Language 31 OSD Hotkey This function allows you to switch the way to trigger the hotkey between Scroll Lock Scroll Lock and Ctrl Ctrl Simply move the red highlight bar to the hotkey setting that you would like to choose and press Enter Then press Esc to exit from this function Port ID Display Position This function allows you to change the position of the port ID that s showing on the screen as the image below Simply change the position by using the up down left and right arrows to adjust to the place that you want the port ID to show in the future and press Enter Port ID Display Duration This function allows you to change the port ID display duration b
9. 92618 P 949 453 8782 F 949 453 8785 Visit us at www iogear com 66 67 About Us FUN IOGEAR offers connectivity solutions that are innovative fun and stylish helping people enjoy daily life using our high technology products GREEN IOGEAR is an environmentally conscious company that emphasizes the importance of conserving natural resources The use of our technology solutions helps reduce electronic waste HEALTH IOGEAR supports healthy and fit lifestyles By integrating products with the latest scientific developments IOGEAR s solutions enhance the life of end users 2009 IOGEAR
10. ALUES SET USER LOGIN SET ACCESSIBLE PORTS SET LOGOUT TIMEOUT OFF EDIT PORT NAMES CLEAR THE NAME LIST ACTIVATE BEEPER ON SET QUICK VIEW PORTS RESTORE Y N Clear The Name List This function allows you to clear up all the port names to blanks Move the red highlight bar to Clear The Name List and press Enter Then type Y to proceed clearing or N to keep the name list SET USER LOGIN i SET ACCESSIBLE PORTS SET EOGOUT TIMEOUT OFF EDIT PORT NAMES RESTORE DEFAULT VALUES ACTIVATE BEEPER ON SET QUICK VIEW PORTS 42 Activate Beeper This function allows you to enable or disable the beeper sound while switching port Move the red highlight bar to Activate Beeper and press Enter Then type Y to activate or N to deactivate SET USER LOGIN SET ACCESSIBLE PORTS SET LOGOUT TIMEOUT OFF EDIT PORT NAMES RESTORE DEFAULT VALUES CLEAR THE NAME LIST SET QUICK VIEW PORTS Set Quick View Ports This function allows you to set the desire ports as Quick View Ports If a port is selected as a Quick View Port an icon will show in the QV column of the OSD main screen Simply more the red highlight bar to the desire port and press Spacebar to select the port as a Quick View Port 43 Set Operating System This function allows you to define what kind of operating system is being used in each port Simply move the red highlight bar to the desire port and press Spacebar to cycle through the options betw
11. CPU1 16 Port 4 Power Jack 2 Grounding 5 Console Port 3 Cable Tie Slot Back view Foot Pad Set Installation Flip the KVM switch upside down Peel the protective films off of the foot pads then stick the pads to the four corners as shown in the diagram below Rack Mounting Step 1 Remove the screws from the left and right sides of the switch 2 screws total near the front of the switch 11 Step 2 Use the M3 x 8 Phillips hex head screws supplied with the rack mounting kit to screw the rack mounting brackets into the sides near the front of the unit 12 Final Step Place the KVM switch in the rack Position it so that the holes in the mounting brackets line up with the holes in the rack Secure the mounting brackets to the front of the rack 727 27 27 7 7 Z IE EHE HZ 13 To prevent damaging your equipment it is important that all devices are properly grounded Use the included grounding wire to ground the KVM switch by connecting one end of the wire to the grounding terminal and the other end of the wire to a suitable grounded object 14 Single Level Installation Step 1 Please make sure your computers and monitor are powered off before you start Step 2 Connect the power adapter to the power outlet and the DC jack of the KVM Step3 Connect the Console cable to the Console port of the KVM Step 4 Connect your VGA monitor and USB or PS 2 keyboard and mouse to
12. ID number on the screen When the Autoscan Mode is activated the console will not function normally until you exit from Autoscan Mode During Autoscan Mode you can press P or left click on your mouse once to pause at a specific port When you are done pausing simply press any key from the keyboard or left click once on your mouse to resume When you are done auto scanning simply press Spacebar or Esc to exit from Autoscan Mode F8 LOUT You can also trigger the autoscan by front panel pushbutton or hotkey command Press and hold Port 7 and Port 8 pushbutton on the GCS1808 Port 15 and Port 16 for GCS1716 to trigger autoscan with default autoscan time interval For hotkey command please refer to Hotkey Setting Mode HSM section 49 F8 LOUT This function allows you to logout of the OSD So when another person is trying to access this from the console he would have to login again Simply Press Y to proceed the logout and N to cancel Hotkey Setting Mode HSM Function 1 Press and hold Num Lock 2 Press and release 3 Release Num Lock Invoke HSM then press h Invoke HSM then press t Invoke HSM then press F1 Invoke HSM then press F2 Invoke HSM then press F3 Invoke HSM then press F5 Description Invoking hotkey setting mode Note To exit HSM manually press Esc or spacebar Change the HSM invocation keys from Num Lock to Ctrl and from to F12 Switch
13. a window will popup and prompt you to ask if you wish to proceed Simply click Yes to start the upgrade and No to cancel the upgrade Warning YD The Firmware Ver 3 0 ae is not newer than current firmware Ver 3 0 292 in device MAIN 001 00 Continue the upgrade Yes No Note If you did not check the Check Firmware Version checkbox utility will perform the upgrade automatically no matter what version of firmware you have in the KVM of Step 8 Warning window may popup again for 2nd part of the firmware upgrade IO1 Warning Y The firmware Ver 3 0 291 is not newer than current firmware Ver 3 0 292 in device 101 001 002 Continue the upgrade Yes No Step 9 Then another warning window may popup for 3rd part of the firmware upgrade lO2 This is for GCS1716 only Warning YD The Firmware Ver 3 0 291 is not newer than current firmware Ver 3 0 292 in device 102 001 003 Continue the upgrade Yes No Step 10 When the firmware upgrade is done you will see Firmware upgrade OK in the Status Messages window Then simply click Finish to complete the whole firmware upgrade process Firmware Upgrade Utility The Firmware upgrade was successful Click Finish to close the utility Device List Status Messages gt Loading amp testing files gt Loading amp testing files OK gt Searching for devices gt Preparing firmwar
14. allation Rack Mounting Grounding Single Level Installation 2 Level Installation Cascading LED Indication Port Switching On screen Display OSD Operation Hotkey Setting Mode HSM Mac Keyboard Emulation Sun Keyboard Emulation Factory Default Settings Firmware Upgrade Upgrade Fail Restore Factory Default Settings Federal Communications Commission FCC Statement CE Statement Limited Warranty Contact 50 52 53 54 55 59 60 62 64 65 66 GCS1808 Overview 1 Port 1 8 switch Button 4 Firmware Upgrade Recovery Switch 2 Reset Button 5 Firmware Upgrade Cable Port 3 USB Sharing Port 6 Power LED Front view Note The USB sharing device can only be used if your computer is connected to the KVM via a USB KVM Cable Also it does not support cascading in other words it can only be shared within the 8 ports of the KVM 6 1 CPU1 8 Port 4 Power Jack 2 Grounding 5 Console Port 3 Cable Tie Slot Back view GCS1716 Overview 1 Port 1 16 Switch Button 4 Firmware Upgrade Recovery Switch 2 Reset Button 5 Firmware Upgrade Cable Port 3 USB Sharing Port 6 Power LED P KIM Ber QIDGEAR Mini v iiewvv VGA KVM SWITCH GCS1716 Front view Note The USB sharing device can only be used if your computer is connected to the KVM via a USB KVM Cable Also it does not support cascading in other words it can only be shared within the 16 ports of the KVM 1
15. c Keyboard Emulation The PC compatible 101 104 key keyboard can emulate the functions of the Mac keyboard The emulation mappings are listed in the table below PC Keyboard Mac Keyboard AI Alt Shift Shift Print Screen F13 Crt Ctrl Scroll Lock F14 Ctrl 1 Enter Return Ctrl 2 mg Backspace Delete Ctrl 3 md Insert Help Ctrl 4 A ctr BS F15 Note When using key combinations press and release the first key Ctrl then press and release the second key 52 Sun Keyboard Emulation The PC compatible 101 104 key keyboard can emulate the functions of the Sun keyboard The emulation mappings are listed in the table below PC Keyboard Crt t Crt F2 Crtl F3 Cri F4 Crtl F5 Crtl F6 Crtl F7 Crtl F8 Note When using key combinations press and release the first key Ctrl then press and release the second key Sun Keyboard Stop Again Props Undo Front Copy Open Paste Ctrl F9 Crtl F10 Crtl 1 Crtl 2 Crtl 3 Orti 4 Crt h Er aa 53 Cut o _ 5 Q m0 Pat Compose Factory Default Settings Function OSD Hotkey Invoking HSM Auto Scan Duration Scan Skip Mode Screen Blanker Beeper Keyboard Operating Platform Port ID Display Position Port ID Display Duration Port ID Display Mode Accessible Ports Auto Logout Time Default Settings Scroll Lock Scroll Lock Num Lock
16. connected and it is powered on but does not focus on the KVM The specific port has focus on the KVM 22 Port Switching Port Switching via Front Panel Switch Button Simply press the specific push button to switch the focus to the specific port Port Switching via On Screen Display OSD Please refer to OSD Operation section Port Switching via Hotkey Please refer to Hotkey Setting Mode HSM section 23 On screen Display OSD Operation Trigger OSD Simply press Scroll Lock Scroll Lock rapidly Note This hotkey sequence can be changed to Ctrl Ctrl Please refer to Hotkey Setting Mode HSM section OSD Login By default the Login and Password are blanks so simply press Enter Enter to login If you have set a user name and password on the KVM simply enter them and press enter to login ENTER NAME AND PASSWORD USERNAME PASSWORD 24 OSD Main Screen When you invoke the OSD a screen similar to the one below appears Notes 1 The diagram depicts the administrator s main screen The user main screen does not show the F4 and F6 functions since these are reserved for the administrator and can t be accessed by users The OSD always starts in list view with the highlight bar at the same position it was in the last time it was closed Only the ports that have been set accessible by the administrator for the current logged in user are visible If there is a H nex
17. e upgrade ai gt Firmware version is not newer than device MAIN 001 001 gt Firmware version is not newer than device 101 001 002 gt Firmware version is not newer than device 102 001 003 gt Preparing firmware upgrade OK gt Upgrading device MAIN 001 001 gt Upgrading device MAIN 001 001 OK gt Upgrading device 101 001 002 Device Description gt Upgrading device 101 001 002 OK gt Upgrading device 102 001 003 Device FAV Ver 3 0 282 Ungrading device 102 001 003 OK Upgrade F w Ver 1 0 081 MID 001 003 VV Check Firmware Version Progress Help View Log 58 Final Step Now the KVM will reset by itself and it will be ready for usage after the rest Upgrade Fail If you don t see Firmware upgrade OK in the Status Messages window it means the utility has failed to complete the firmware successfully If that occurs please do the following Step 1 Unplug the power from the KVM Then connect the provided firmware upgrade cable to the firmware upgrade port of the KVM and the serial port of your computer Step 2 Slide the Firmware Upgrade Recovery Switch to the Recover position slide to the right Then connect power adapter back to the KVM FIW UPGRADE NORMAL RECOVER 59 Step 3 Repeat the firmware upgrade process Please refer to Firmware Upgrade section Step 4 After the firmware upgrade has completed the KVM will
18. een WIN MAC SUN or OTHER Note The keyboard Operating platform will changed accordingly depending what you have chosen in this function For example if you have chosen Mac in Port 1 as the image is shown the keyboard will change Mac keyboard emulation mode Please see Hotkey Setting Mode HSM and Mac Sun Keyboard Emulation sections to see the details 44 Firmware Upgrade This function allows you to have the KVM activates the firmware upgrade mode so that you can perform a firmware upgrade to the KVM If you would like to do a firmware upgrade connect the firmware cable between the computer and KVM then type Y to proceed with the firmware upgrade otherwise type N to cancel DOD rour PGDOWN CONNECT THE DOWNLOAD CABLE DOWNLOAD Y N After you type Y you will see the below screen The KVM is now in firmware upgrade mode Please see Firmware Upgrade section for details about how to perform a firmware upgrade Keyboard Language This function allows you to choose the keyboard language of your console keyboard Auto is chosen by default if you want to change the language simply move the red highlight bar to the desire keyboard language that you wish to change to and then press Enter ADMINISTRATOR 46 F5 SKP This function allows you to trigger Skip Mode Simply press F5 to activate skip mode When you see a left and right arrow next to the port number as the image below you can pr
19. ess the arrow keys to skip to different ports Skip Mode s behavior depends on the setup that you chose in Scan Skip Mode please to F3 SET for more detail about Scan Skip Mode 47 Function gt 1 N Description Switch to the last accessible port Switch to the next accessible port Switch to the last accessible port Note If you have cascaded your KVM it will switch to the last accessible port from level 2 of the last port from level 1 Switch to the next accessible port Note If you have cascaded your KVM it will switch to the next accessible port from level 2 of the next port from level 1 F6 BRC F7 SCAN F6 BRC This function will only be shown if you have login as Administrator Simply press F6 to trigger Broadcast BRC Mode then you will see a speaker symbol next to the port number When BRC is activated your command that you send from the console will be sent to all available computers the computers that are listed in the OSD main screen please go to F2 LIST section for details During BRC Mode console mouse will not function normally Simply press F6 again to turn BRC Mode off 48 F7 SCAN This function allows you to autoscan all the available ports This autoscan behavior depends on the Scan Skip Mode and Scan Duration Please go to F3 SET section for details Simply press F7 to trigger Autoscan Mode then you will see a S next to the port
20. etary notices or labels on the Product including copyright trademark or patent pending notices ou may not sublicense the Product or otherwise allow others to use the Product licensed to you z Agee Dont gree 56 Step 6 Choose the correct KVM that you wish to perform firmware upgrade from the Device List and then click Next to continue Then the Firmware Upgrade Utility will verify if there is a KVM connected to the computer by the firmware upgrade cable Check Firmware Version checkbox is optional Firmware Upgrade Utility If Check Firmware Version is checked the utility compares the device s firmware level with the upgrade files If the device s version is newer the utility lets you decide whether to continue or not If itis not checked the utility performs the upgrade directly Click Next to begin Device List Status Messages MAIN 001 001 gt Loading amp testing files ing ing files Device Description Device FAW Ver 3 0 292 Upgrade F w Ver 1 0 081 MID 001 001 IV Check Firmware Version Progress Help View Log Note Please choose MAIN to proceed the firmware upgrade IO1 and IO2 are sub layers in the KVMs firmware Step 7 If you have checked the Check Firmware Version checkbox then the utility will check the current firmware that is on your KVM If the current firmware is newer than the firmware that you wish to upgrade to
21. etween 3 seconds and off Simply move the red highlight bar to the option that you would like to choose and press Enter Then press Esc to exit this function 32 Port ID Display Mode This function allow you to choose the way you want to show the ports in the OSD main screen port number only port name only or both Simply move the red highlight bar to the option that you like to uSe and press Enter Then press Esc to exit from this function UP DOWN RT ID DISPLAY MODE PORT NUMBER PORT NAME 33 Scan Duration This function allows you to set the autoscan time interval between O second to 255 seconds 5 second is set by default Simply enter the number between 0 225 and press Enter UP i PGUP DOWN 4 PGDOWN OSD HOTKEY PORT ID DISPLAY POSITION amp PORT ID DISPLAY DURATION PORT ID DISPLAY MODE SCAN SKIP MODE SCREEN BLANKER OFF HOTKEY COMMAND MODE ON 0 255 SEC Scan Skip Mode This function allows you to set the behavior in autoscan mode Simply move the red highlight bar to the behavior you want and press Enter Then press Esc to exit from this function Function All Quick View Powered ON Quick View Powered ON Description Scan all ports that the administrator has set as accessible for the current logged in user Scan only the ports that have been set as quick view ports This option will only show up for administrator account Scan only the
22. hen press Esc to exit from this youwish to choose and press Enter Then press function Esc to exit from this function EXIT UP So Chee HI UP SELECT DOWN NTER SELECT DOWN ADMINISTRATOR ADMINISTRATOR SET QUICK HOTKEY SET OSD LANGUAGE 36 F4 ADM This function will only be shown if you have login as Administrator There are 11 different functions within the ADM section which they are as follow Set User Login Set Accessible Ports Set Logout Timeout Edit Port Names Restore Default Values Clear The Name List Activate Beeper Set Quick View Ports Set Operating System Firmware Upgrade Keyboard Language 37 Set User Login This function allows you to setup the login name and password for the users accounts There are 5 user accounts in the system Administrator User1 User2 User3 and User4 Move the red high light bar to the user account that you wish to setup and press Enter Then simply type in the user name and Once the user name and password are set password Then enter the password again for correctly you will see the message in the bottom of confirmation then press Enter We have used the the screen indicating the setup is ok Then simply administrator account as an example press Esc to exit from the function ADMINISTRATOR 38 Set Accessible Ports This function allows you to setup the access on each port for each user Use Spacebar to cycle through all the entries and
23. press Enter to complete the setup Then press Esc to exit from the function Function Description F Full User has full access on the specific port V View User can only view the port with no access for the specific port Blank User cannot view nor access for the specific port 39 Set Logout Timeout Edit Port Names This function allows you to set a time that the KVM This function allows you to customize a name will automatically logout after being idle for a certain on each port of the KVM Simply move the red period of time Move the red highlight bar to this highlight bar to the port that you wish to customize function and press Enter Then enter a number a name and press Enter from 0 180 in terms of minutes as the time interval and press Enter _ EDIT PORT NAMES RESTORE DEFAULT VALUES CLEAR THE NAME LIST ACTIVATE BEEPER ON SET QUICK VIEW PORTS 40 Enter the port name that you wish to show in OSD for that specific port and press Enter to complete the editing Then press Esc to exit from this function UP J PGUP DOWN 3 PGDOWN ISTRATOR T PORT NAMES QV NAME 41 Restore Default Values This function allows you to restore all settings into factory default settings Move the red highlight bar to Restore Default Values and press Enter Then type Y to proceed restoring or N to cancel the restore uj PGUP B IVERS SELECT DOWN 2 PGDOWN ADMINISTRATOR RESTORE DEFAULT V
24. t to the monitor icon which means that port is attached to another KVM Cascading Click on a switch number or move the highlight bar to it then press the right arrow key to expand the list Similarly to collapse a switch s port list click on the switch number or move the highlight bar to it then press the left arrow key to collapse the list 25 OSD Main Screen Headings Heading PN QV Name Description This column lists the port ID numbers for all the KVM ports on the installation The simplest method to access a particular computer is move the highlight bar to it then press Enter QV If a port is selected for quick view scanning an arrowhead shows in this column The computers that are powered on and are online will a sun symbol in this column to indicate so If a port has been given a name its name appears in this column 26 OSD Navigation To dismiss the menu and deactivate OSD click the X in the upper right corner of the OSD window or press Esc To log out click F8 at the top of the main screen or press F8 To move up or down through the list one line at a time click the up and down triangle symbols A Y or use the up and down arrow keys on the keyboard If there are more list entries than what appears on the main screen the screen will scroll down To move up or down through the list one screen at a time click the up and down arrow symbols t4 or use the PgUp and PgDn
25. th FCC radiation exposure limits set forth for an uncontrolled environment End users must follow the specific operating instructions for satisfying RF exposure compliance This transmit ter must not be co located or operating in conjunction with any other antenna or transmitter 63 CE Statement This device has been tested and found to comply with the requirements set up in the council directive on the approximation of the law of member states relating to EMC Directive 89 336 EEC Low Voltage Directive 73 23 EEC and R amp TTE Directive 99 5 EC The product has been approved for LVD and covered the following countries Belgium Denmark France Germany Italy Portugal U K Spain Sweden 64 Limited Warranty IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE PRODUCT DISK OR ITS DOCUMENTATION EXCEED THE PRICE PAID FOR THE PRODUCT The direct vendor makes no warranty or representation expressed implied or statutory with respect to the contents or use of this documentation and especially disclaims its quality performance merchantability or fitness for any particular purpose The direct vendor also reserves the right to revise or update the device or documentation without obligation to notify any individual or entity of such revisions or updates For further inquiries please contact IOGEAR 65 IOGEAR 23 Hubble Irvine CA
26. the console Cable 16 Step 5 Connect a USB KVM Cable with a green connector or PS 2 KVM Cable with a yellow connector from the KVM switch to each of your computers USB KVM Cable Connection PS 2 KVM Cable Connection 388 or Final Step Turn on your computers 17 2 Level Installation Cascading Step 1 Step 4 Please make sure your computers and monitor are Connect your VGA monitor and USB or PS 2 powered off before you start keyboard and mouse to the console Cable Step 2 Connect the power adapters to the power outlet and the DC jack of the KVMs Step 3 Connect the Console cable to the Console port of the 1st level KVM 18 Step 5 Connect the Cascade Cable between the 1st level KVM and 2nd level KVM Connect the green connector to 1 of the 1st level KVM switch s CPU port Then connect the yellow connector to the console port of the 2nd level KVM switch 1st Level 2nd Level Step 6 Connect a USB KVM Cable with a green connector or PS 2 KVM Cable with a yellow connector from the 2nd level KVM switch to each of your computers 2nd Level 20 USB KVM Cable Connection PS 2 KVM Cable Connection Final Step Turn on your computers 21 LED Indication LED No LED Orange Green Description No computer is connected to the specific port or the computer is connected to the specific port but it is not powered on The specific port has a computer