Home
Da-Lite Tensioned Large Cosmopolitan Electrol 120" x 160"
Contents
1. The Da Lite Difference Instruction Book for TENSIONED LARGE COSMOPOLITAN ELECTROL A P DA LITE SCREEN COMPANY LLC 3100 North Detroit Street Post Office Box 137 Warsaw IN 46581 0137 USA P 800 622 3737 574 267 8101 F 877 325 4832 574 267 7804 www da lite com e mail info da lite com IMPORTANT SAFETY INSTRUCTIONS When using your video equipment basic safety precautions should always be followed including the following Read and understand all instructions before using 2 Position the cord so that it will not be tripped over pulled or contact hot surfaces 3 If an extension cord is necessary a cord with a current rating at least equal to that of the appliance should be used Cords rated for less amperage than the appliance may overheat 4 To reduce the risk of electric shock do not disassemble this appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently 5 he use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons SAVE THESE INSTRUCTIONS INSTALLATION Carefully unpack screen and remove outer wrapping from case The slat retainer screws must be removed before installation The slotted 1 4 hex screws fasten through the back of the case at the bottom into the slat bar Orient the
2. DARD WALL SWITCH Da Lite offers two styles of 240 volt wall switches for standard operation Please see wiring diagram in wall switch boxes included with screen TENSIONED LARGE COSMOPOLITAN ELECTROL INSTALLATION FOR SCREENS WITH A BUILT IN LOW VOLTAGE CONTROL RJ 14 PIN OUTS RJ 22 PIN OUTS 120V WIRING DIAG RAM TAB IS FACING UP TAB IS FACING UP WITH OPTIONAL BUILT IN LOW VOLTAGE CONTROL RJ 45 PIN OUTS TAB IS FACING UP RJ 45 RECEPTACLE RJ 45 JACK FRONT OF BACK OF WALL SWITCH WALL SWITCH POWER WIRE 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE GREEN GROUND L The wall switch is REQUIRED to make any limit switch BLACK HOT adjustments EVEN if a third party control system is WHITE COMMON GROUND MUST BE it i ji i CONNECTED TO used Therefore it is advised to wire the switch or CONNECTED TO provide a 3 conductor connection that is accessible POWER INPUT 120VAC 60HZ 240V WIRING DIAGRAM WITH OPTIONAL BUILT IN OPTIONAL IR AND RF LOW VOLTAGE CONTROL REMOTE CONTROL LOW VOLTAGE WALL SWITCH BLUE COMMON BROWN HOT GREEN 240VAC 50HZ 3 POSITION SWITCH RJ9 GROUND MUST BE GREEN CONNECTED TO al BUILDING GROUND GROUND TO CASE BACK DRY CONTACTS ILT RJ9 PIN OUTS IMPORTANT
3. NOTE The wall switch is REQUIRED to make any limit eee switch adjustments EVEN if a third party control in kolanon Sten system is used Therefore it is advised to wire the Dar DATA s switch or provide a 4 conductor connection that is accessible TROUBLESHOOTING Visit www da lite com products product_videos php to find installation and troubleshooting videos and tutorials You will also find a link to Live Chat for interactive support and you can contact us by email at info da lite com or by phone at 800 622 3737 or 574 267 8101 with any troubleshooting questions SYMPTOM 1 Screen will not operate Motor does not hum 2 Incorrect stopping position in downward direction 3 Incorrect stopping position in upward direction 4 Noise NOTE Screen will operate with a low pitched hum 5 Coasting a Blown fuse b Tripped circuit breaker c No power to operating switch or junction Power at junction box d Thermal overload tripped e Broken wire in the down or up position f Defective motor limit switch or capacitor g Capacitor burned out Lost roller wrap b Down limit switch out of adjustment a Lost roller wrap b Up limit switch out of adjustment a Gear Noise a Defective brake 5 CAUSE SOLUTION Replace fuse Reset circuit breaker Check above Tighten all loose wire connections Correct any improper connections Down Positio
4. case with the slat down and then remove the screws The case must remain in that orientation throughout the installation process to avoid fabric damage The Tensioned Large Cosmopolitan Electrol comes with brackets to allow for wall mount or ceiling mount installations Procedures for each method are as follows Wall Mount 1 The wall mount bracket should be fastened to wall studs or some reinforcement within the wall Concrete or brick walls require special fasteners and anchors 2 The wall bracket has holes spaced at 16 and 24 to align with most wall studs p 1E 1 3 The bracket must be level and plumb Keep in mind you will need at least 2 3 4 between the ceiling and the top of the wall mount bracket to be able to position the case on the bracket amp E BRACKET 5 Mount the screen case on the wall bracket as shown in figure 1 Be sure the case is fully seated on the bracket Tighten the stop screws against the wall VIEWING SURFACE bracket AUDIENCE SIDE STOP SCREW FIGURE 1 Ceiling Mount 1 Be sure the ceiling has adequate reinforcement to attach the screen brackets CASE HOOK 2 Attach the ceiling brackets to the wall mount bracket CEILING using the supplied 5 16 x 3 4 bolts washers and p MOUNT nuts 5 16x3 4 Re E N BOLT NU 3 Position the ceiling bracket assembly on the ceiling AND LOCK and attach with 5 16 bolts not supplied The bolts WASHER should be long enough to pas
5. n Check for power across black and white leads Up Position Check for power across red and white leads Let motor cool down for 15 minutes Try again Check for continuity Cut off old splice and reconnect Replace motor assembly NOTE Motor is a sealed assembly Replace motor assembly See instructions below Contact Da Lite at 800 622 3737 or 574 267 8101 See instructions below Contact Da Lite at 800 622 3737 or 574 267 8101 Replace motor assembly Replace motor assembly THIS PAGE IS INTENTIONALLY LEFT BLANK LIMITED ONE YEAR WARRANTY ON DA LITE PRESENTATION PRODUCTS Da Lite Screen Company LLC warrants its products to the original purchaser only to be free from defects in materials and workmanship for a period of one 1 year from the date of purchase by the original purchaser provided they are properly operated according to Da Lite s instructions and are not damaged due to improper handling or treatment after shipment from the factory This warranty does not apply to equipment showing evidence of misuse abuse or accidental damage or which has been tampered with or repaired by a person other than authorized Da Lite personnel Da Lite s sole obligation under this warranty shall be to repair or to replace at Da Lite s option the defective part of the merchandise Returns for service should be made to your Da Lite dealer If itis necessary for the dealer to return the screen or part to Da Lite transpor
6. s through the drywall or ceiling tile and penetrate at least 1 1 2 into the reinforcement in the ceiling WALL MOUNT 4 Mount the screen on the wall bracket as shown in BRACKET figure 2 Be sure the case is fully seated on the STOP SCREW bracket Tighten the stop screws against the wall bracket VIEWING SURFACE AUDIENCE SIDE FIGURE 2 SCREEN ADJUSTMENT Screen travel is stopped automatically in the down and up positions by the limit switches that are preset at the factory No further adjustment is necessary Mare DA LITE AT 800 622 3737 OR 574 267 8101 IF SCREEN MOTOR NEEDS ADJUSTMENT TENSIONED LARGE COSMOPOLITAN ELECTROL INSTALLATION FOR SCREENS WITHOUT A BUILT IN LOW VOLTAGE CONTROL Internal wiring has been completed at the factory Installer must route power to the wall switch and to the junction box located on the left end of the screen case See wiring diagram below for wire connections NOTE This screen can only be controlled by a single 120VAC or 240VAC wall switch To use multiple switches an optional low voltage control must be used 120V WIRING DIAGRAM FOR STANDARD WALL SWITCH JUNCTION BOX LOCATED IN T id Hj OTE A SINGLE SWITCH CANNOT BE USED TO OPERATE MORE THAN ONE SCREEN CONTACT THE FACTORY FOR FURTHER INFORMATION BLACK DOWN AC COMMON SPDT SWITCH WITH CENTER OFF AC HOT 120VAC 60HZ 1 AMP BLACK YELLOW THIS SWITCH CAN NOT BE USED WITH LVC 240 VOLT WIRING DIAGRAM FOR STAN
7. tation expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also have other rights which vary from state to state NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT OR FOR INCIDENTAL DIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE In the event that there is a defect in materials or workmanship of a Da Lite product you may contact our Sales Partners at PO Box 137 Warsaw IN 46581 0137 574 267 8101 800 622 3737 IMPORTANT THIS WARRANTY SHALL NOT BE VALID AND DA LITE SHALL NOT BE BOUND BY THIS WARRANTY IF THE PRODUCT IS NOT OPERATED IN ACCORDANCE WITH DA LITE S WRITTEN INSTRUCTIONS Keep your sales receipt to prove the date of purchase and your original ownership Printed in U S A 98770 Rev 3 12
Download Pdf Manuals
Related Search
Related Contents
PDF Manual - Light Action, Inc. xl-31 owners manual - Intelligent Security & Fire Ltd SolvisMax Bedienung Anlagenbetreiber Remington D5000 hair dryer Descargar PDF 78K/0S Series 8-Bit Single-Chip Microcontroller Instructions Copyright © All rights reserved.
Failed to retrieve file