Addonics Storage Rack DA
Contents
1. Screws Installing Storage Devices on the Storage Rack A 3 5 hard drive 1 Attach the 3 5 to 5 25 mounting brackets onto both sides of the 3 5 SATA or IDE hard 2 Attach the ventilation front panel and base onto one side of the mounting bracket using the black screws included with the Storage Rack www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query B 5 25 Storage devices 1 Separate the ventilation front panel and the metal base by removing the two flat head screws 2 Attach the metal base onto the optical drive or other 5 25 storage device using the flat head screws from the ventilation front panel Optical Drive O O O O Addonics Drive Cradle O O O O O O www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query C 3 5 Mobile Rack 1 Separate the ventilation front panel and the metal base by removing the two flat head screws 2 Attach the 3 5 drive cradle onto the 3 5 to 5 25 drive bay mounting bracket at the six aligned screw hole locations 3 Attach the metal base onto the optical drive or other 5 25 storage device 1 using the flat head screws from the ventilation front panel O O OO With the storage device connected slide the metal base back into the drive cage Secure the storage device onto the top of th
2. Selection Features Fan1 to Fan8 could be set either ENABLE or DISABLE When all the fans are set on DISABLE the Fan LED will have no light on When Ambient temperature or temperature inside the storage rack is over the set temperature the LED will flash and the buzzer will sound www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query 4x1 Hardware Port Multiplier AD4SR5HPMU E PM Health LED eSATA LED USB LED 4 a Tym el MA eSATA RAID config rotary switch USB port connection to any USB controller pe USB SATA SA ay RAID setting button L eSATA Port pone Pwa Veni pns USB 5 Pin Header i Rotary Switch USB 5 Pin Header Pin Assignment LED Pin Assignment Bg eSATA Status USB Status Pin Name Cable color Description 1 VCC Red 5V ae PM Power e PM Health NM ic O ai HO 3 PWR 8 ACCESS 3 D Green Data 6 1 HD 2PWR E ACCESS P migas ran na as mwan tt HD 1 PWR 2 ACCESS 4 GND Black Ground SoIUOppY P HDOPWR amp ACCESS LED Status Drive Activity LED Always ON The LED blinks when there is drive activity PM Health Always OFF when RAID volume is working correctly The LED starts blinking when the RAID volume is degraded PM Power Always ON when power is provided to the HPM USB Status ON when USB port is connected eSATA Status ON when eSATA port is connected Instructio
3. TECHNOLOGIES User Guide Storage Rack SR46S4R5HM www addonics com v8 1 11 Technical Support If you need any assistance to get your unit functioning properly please have your product information ready and contact Addonics Technical Support at Hours 8 30 am 6 00 pm PST Phone 408 453 6212 Email http www addonics com support query Front Power Switch POWER System Reset LI RESET Buzzer Reset LI Buzzer Bac Punch out for USIB connectors Fans POWER SA HA TEMP SM e LED Display fr e eee Sl FAN Punch out for USIB connectors I U U Power Supply Punch out for eSATA Punch out for port multipliers bridges Power Switch This is the switch to power on devices connected to the power supply The power LED will light up to indicate power is supplied Note The main power switch located at the back of the enclosure must be turned on first Reset Button Not operational Buzzer Reset Pressing the button stops the overheat buzzer from making a sound The buzzer will make a sound when temperature inside the storage rack exceeds the temperature setting on the Thermal Management card Note Buzzer reset switch does not silence the port multiplier buzzer Power LED Lights up when the power switch is turned on Temp LED Lights up when temperature setting inside the storage rack exceeds the setting on the thermal card Fan LED No
4. ck turn on the power switch of the power supply Power Switch Storage Rack DA with Port Multiplier Using Multilane Connection Note The Port Multiplier will only work with Port Multiplier aware multilane host controllers It is compatible with multilane host controllers using the Silicon Image Chip Sil3124 amp Sil3132 When the port multiplier PM is connected to the multilane host controller with Sil3124 or Sil3132 chip in the RAID BIOS of the host controller you will only see one drive and that is the drive connected to SATA port 1 on the Port Multiplier All SATA drives connected to the PM will show in the SATARAID5 Array Manager Refer to the SATARAID5 Management Utility User Guide V1 6 for RAID implementation http Awww addonics com support user_guides host_controller SATARAID5 UserGuid e v1 60 pdf Connecting the Power Cable and RAID Rack to the Computer a Connect the power cord provided from the wall outlet to the back of the rack b Make sure the power is off power LED light should be off C Connect the RAID Rack to the computer using either the USB or eSATA cable www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query CONIACTUS www addonics com Phone 408 573 8580 Fax 408 573 8588 Email http www addonics com sales query
5. e drive cage using the included screws www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query At the bottom of the drive cage locate the metal base corresponding to the storage device inserted in the previous step and secure it onto the drive cage VT lt 4 When you finished install the drive cage now populated with the devices back into the Storage Rack www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query Installing Additional Bridge Boards on Mounting Poles Inside the Storage Rack Separate PM or HPM from bracket by unscrewing 4 screws on the PCB Install the PM or HPM onto the desired mounting pole Installing Bridge Boards onto Back Panel Remove punch outs from the rear panel of the Storage Rack Using the included screws attach bridge board onto the desired back panel mounting location Connect storage devices onto the internally mounted PM or HPM then connect the host connection onto the rear mounted bridge board SATA Device PM HPM Bridge Board www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query Power Supply This power supply provides 500W of power Before turning on the main switch located on the front panel of the storage ra
6. n for Special RAID Modes BIG 2 2 Drives Spanned O Note Do not connect more than 2 SATA drives to the hardware port multiplier Doing so will hang the system when you configure the raid O For SATA drives with different capacities the hardware port multiplier will use the smallest drive capacity of the 2 drives connected to create the total partition size FAST 2 2 Drives Striped Note Do not connect more than 2 SATA drives to the hardware port multiplier Doing so will hang the system when you configure the raid www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query Setting RAID on the HPM 1 Attach the SATA hard drives up to 4 to the SATA ports on the Hardware Port Multiplier HPM using SATA cables It is recommended to connect drives to the SATA ports 1 to 4 successively 2 Set the Rotary switch to the RAID mode required 3 Push the RAID setting button with a ballpoint pen tip while the HPM is turned off Use a ballpoint pen E tip to press the n GQ RAID Setting Button QQ 4 While holding the RAID setting button turn on the HPM and SATA hard drives and continue to hold button for at least 5 seconds Note The onboard LEDs for the eSATA and USB will start blinking while holding down the raid setting button Once the raid setting button is released the PM Health LED will blink 4 6 times If the PM Health LED stops blinking the raid set is
7. rmally on when fan is operational If an abnormal condition is detected the LED flashes HDD LED Not operational www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query How to Remove the Top Cover i 2 3 To Mount Back the Top Cover 1 2 3 How to Remove the 5 1 2 Drive Cage L Top Cover Screws Locate the 2 screws at the back of the storage rack Turn screws counterclockwise to loosen Lift the top cover and pull towards the rear end of the rack Align the top cover with the edges of the rack Lay it flat on the rack and slide it towards the front of the rack Turn screws clockwise to tighten Locate the 4 screws on the drive cage Turn screws counterclockwise to loosen Lift the chassis up www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query How to Remove the 5 4 Drive Bay Front Panels 1 Locate the 3 screws for each front panel 2 Turn screws counterclockwise to loosen 3 Pull the front panel forward away from the drive cage 3 screws for each panel Thermal Management Card on the RAID Rack Fan Connectors Overheat Buzzer O Floppy Power Connector ds dde de dde des des Jud des Ambient Detect Terminal EEE oe Temp Setting Fan Temperature and Power LED Connectors 40 C 50 C 60 C Fan Detect
8. set correctly If the PM Health LED lights up as solid green itis a bad setup You need to repeat setting up the raid again Verify RAID Setting on the HPM It is assumed that you have already connected the SATA drives and set up the raid mode when verifying the raid setting 1 Disconnect the HPM from host 2 Turn on the Storage Rack 3 Hold down the RAID setting button with the tip of a ball point pen Using the table below verify if the LEDs are lighting up The selected LEDs will light up Note Use the embedded LED s located on the HPM board as reference RAID Mode LEDs E RA 7 USB Status 8 eSATA Status www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query Installing the 4th Disk Array on the Storage Rack a Remove the back panel of the storage rack by loosening the 4 screws indicated below Screws b Secure the bottom bracket of the storage rack to the disk array using SCrews C Secure the top bracket of the storage rack to the disk array using screws d Slide the disk array into the storage rack lt www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query Screws O MO e Secure the Disk array by screwing the top and bottom brackets to the frame of the storage rack eee
Download Pdf Manuals
Related Search
Related Contents
CL5000 Series Mora VT 422 XC Bolens 12226 Tiller User Manual EN 60745, EN 55014, EN 61000-3-2, EN 61000-3-3 Bell 230 - Graupner PCTV PCTV Digital - Positivo Informática Covert Channels Evaluation Framework Design and Implementation AccuPlate™ Analog Hotplate, Stirrers, Hot Plate Stirrer User Manual Manual Copyright © All rights reserved.