1. Select the Battery Tab as shown in Figure 4 4 GXT3 Configuration Program User Manual 8 Chapter 4 Tabs EM Emerson UPS GEI3 Tool urs Options Beery Abou EMERSON CAUTION The UPS can be in any mode for the settings to take effect Low Battery Time Warning 2 v min IR Battery Cabinets Recommendation Do not change Auto Battery Test Time 14 Tf Battery Cabinets internal Recommendation Do not change the above settin during Battery Mode Allow batteries to fully charge after confibwing IV Enable auto battery test IV Enable auto restart IV Enable auto shutdown Help Menu The auto battery test will perform automatic battery A test periodically when enabled The user may select the time between battery tests The time periods can be setto 7 14 21 and 28 days The auto battery test time factory default is 14 days IV Enable auto battery test IV Enable auto restart IV Enable auto shutdown Help Menu Refresh OK Cancel Apply Factory Setting Figure 4 4 Battery Tab LY Note In the Battery Tab the UPS can be in any mode for the setting to take effect Low battery time warning The UPS will estimate remaining operating time when on batteries Alow battery alarm is activated ifthe estimated time reaches the Low Battery Time The value of Low Battery Time Warning can be selected from 2 to 30 minutes Auto battery test time The UPS performs an automated ba
2. terminal block of the UPS by operating Pin1 amp Pin2 If selected the Disable Output Manual Restart Only setting will require the UPS to be manually restarted by pressing the Start button on the front panel of the UPS after the Any Mode Shutdown signal on the terminal block has been removed aa Note If the UPS is in a remote location with limited access then the setting should not be used Auto enable output automatically For particular industrial applications and special computer applications the UPS maybe monitored and controlled using external voltages and relay contact signals An Any Mode Shutdown command can be activated on the terminal block of the UPS by operating Pin1 amp Pin2 If selected the Auto Enable Output Automatically setting will automatically restore the UPS output after Any Mode Shutdown signal on the terminal block has been removed Default operation normally open The shutdown logic can be configured for nomally open or normally closed This setting defines the configuration of the Any Mode Shutdown If selected the Any Mode Shutdown will operate when Pin1 amp Pin2 of the terminal block are connected Inverted operation normally closed The shutdown logic can be configured for normally open or nomally closed This setting defines the configuration of the Any Mode Shutdown If selected the Any Mode Shutdown will operate when Pin1 amp Pin2 of the terminal block are disconnected Battery Tab
3. GXT3 Configuration Program User Manual Version v1 0 Revision date September 24 2009 BOM 31012253 Liebert provides customers with technical support Users may contact the nearest Liebert local sales office or service center Copyright O 2009 by Liebert All rights reserved The contents in this document are subject to change without notice Homepage www liebert com Monitoring Email liebert monitoring emerson com Tel 800 222 5877 800 1155 4499 Outside North America Single Phase 8 Three Phase UPS Email liebert upstech emerson com Tel 800 222 5877 800 1155 4499 Outside North America Locations United States 1050 Dearborn Drive P O Box 29186 Columbus OH 43229 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco PD Italy Tel 39 049 9719 111 Fax 39 049 5841 257 Asia 29 F The Orient Square Building F Ortigas Jr Road Ortigas Center Pasig City 1605 Philippines Tel 63 2 687 6615 Fax 63 2 730 9572 Contents Chapter TATI UCA EG 1 1 1 Features RRA QUIM N EAT ETAETA E ETT 1 Chapter 2 Communication 2 28 Atha a rat EEE NSA A En 2 231 Connecting The USB Gabe 4 irre ii 2 2 2 Starting Ihe POMAR td na 2 2 3 Communicating With The UPS 00 ato 2 Chapter Operation A AAA A ee a 3 3 1 Read Contig UPS Settings Only en nn nn 3 32 Changing UPS Settings saia ais A a 3 3 2 1 Canceling TNE SONS lid 3 3 22 Restore The SettingS imita Ara 3 3 2 3 Changing The Se
4. HZ Bypass Disabled Frequency Converter BOHZ Bypass Disabled Audible Alarm Control Enable Audible Alarm Control Help Menu The UPS checks the input wiring at startup If the input Line Neutral is reversed or ground is missing _ the UPS will not start If a problem is detected after the UPS is started the UPS will continue to operate but the Refresh OK Cancel Apply Figure 4 1 UPS Tab In the UPS Tab the UPS must be in Standby mode for the setting to take effect Output voltage selection The output voltage displayed in the Output textbox is the nominal input output voltage This is the nominal output setting not a measured value The drop down box will show the altemate L N voltages available Select the voltage that matches the application as shown in Figure 4 2 EM Emerson UPS GEI3 Tool UPS options Battery About EMERSON CAUTION The UPS must be in Standby Mode for the settings to take effect UPS Model SXT3 3000RT120 Output 120 2 IV Enable L N Rever 110 Frequency Selection115 U or BURZ Bypass Disabled Frequency Converter 50HZ Bypass Disabled Frequency Converter BOHZ Bypass Disabled Audible Alarm Control IV Enable Audible Alarm Control Help Menu The UPS checks the input wiring at startup a If the input Line Neutral is reversed or ground is missing the UPS will not start If a problem is detected after the UPS is started the UPS will continue to operate bu
5. g the Cancel button and the settings are canceled Restore The Settings If you decide to restore the UPS settings after modifying the displayed settings and prior to select OK or Apply button select the Refresh button to restore the UPS settings to the existing values stored in the UPS Changing The Settings Requirements on the UPS All UPS settings can be changed when the UPS is in Standby mode with AC input power available Pay attention to the following two conditions e Settings on the UPS Tab and Options Tab can only be changed with the UPS in Standby mode e Settings on the Battery Tab can be changed with the UPS in Normal or Standby mode If the UPS is in Normal Mode operation press the OFF button once to put the UPS into Bypass Mode Once the UPS is in Bypass Mode operation press and release the OFF button two distinct times for about a second each time to place the UPS in Standby mode This will disconnect all power to the load Saving the changes Changing any value or selecting deselecting any setting in the configuration window will not immediately change the settings in the UPS You may modify the displayed settings until you are satisfied with the new proposed changes After that you can save the values by selecting either the Apply or OK button e The Apply button sends the new settings to the UPS without closing the program e The OK button sends the new settings to the UPS and closes the program Whenever the val
6. h the Battery Tab and the UPS Tab or Options Tab are selected the UPS will only save the changes on the Battery Tab The Partial Save message will be displayed as shown in Figure 3 3 Partial Save Only the Battery settings have been saved To save all the changes the UPS must be in Standby Mode Standby Mode is when the UPS has only input power On the front panel of the UPS only the AC input indictor will be illuminated To save the UPS and Option settings following these steps 1 Close the configuration program 2 Put the UPS in Standby Mode 3 Change the UPS and Option settings again 4 Select Apply Figure 3 3 Partial save GXT3 Configuration Program User Manual 4 1 This chapter details the four tabs ofthe program including the UPS Tab Options Tab Battery Tab and About Tab UPS Tab When the program starts the UPS Tab will open displaying the UPS model along with the current UPS settings as Chapter 4 Tabs Chapter 4 Tabs shown in Figure 4 1 The information can be refreshed at any time using the Refresh button na Note ES Emerson UPS GXI3 Tool UPS Options Battery About CAUTION The UPS must be in Standby Mode tor the settings to take effect UPS Model 6XT3 3000RT120 Output 120 v Volts IV Enable L N Reverse Detection 120V UPS Only Frequency Selection Auto Sensing 50 or 60 HZ Bypass Enabled Auto Sensing 50 or 60 HZ Bypass Disabled Frequency Converter SO
7. hutdown is checked then the UPS will continue to shutdown even if the Utility power returns If Enable Auto Shutdown is unchecked then UPS will retum to Utility when the input power returns GXT3 Configuration Program User Manual 4 4 About Tab Selectthe About Tab as shown in Figure 4 5 E Emerson UPS GEI3 Tool UPS Options Battery About EMERSO Network Power The distribution of GXT3 configuration program will be on a CD ROM contained within the accessory package All UPS units will ship with the GXT3 Configuration program CD For your convenience the user manuals for both configuration program and UPS will be contained on the same CD ROM Here is a list of all the items which will be contained on the CD ROM 1 GXT3 Configuration Program including all required files for installation Configuration Program user manual Liebert GXT3 user manuals Adobe Reader 8 0 or later Adobe Flash 9 0 or later OK Cancel Apply Factory Setting Figure 4 5 Window of About Tab The contents of the CD can be seen in the About Tab GXT3 Configuration Program User Manual Chapter 4 Tabs 9
8. rify that the UPS is powered 3 Temporarily remove the webcard or option card from the intelislot of the UPS 4 Verify the USB port is not being used by another program 5 If installed stop Multilink software using the stop command Ignore Cancel Figure 2 1 Communication error In this case check the following items 1 Verify that the USB cable is connected securely between the computer and the UPS 2 Verify that the UPS is powered 3 Temporarily remove the webcard or option card from the Intelislot port of the UPS 4 Verify the USB portis not being used by another program 5 If installed stop Multilink software using the stop command GXT3 Configuration Program User Manual 3 1 3 2 3 2 1 3 2 2 3 2 3 Chapter 3 Operation 3 Chapter 3 Operation This chapter details how to operate the program including read config UPS settings onlyand changing UPS settings Read Config UPS Settings Only This program can monitor the UPS settings while the UPS is operating in any mode Ifthis program is only used to read config the present UPS settings you do not need to use any buttons except the Cancel button to close the program Changing UPS Settings To change the UPS settings there are three conditions canceling the settings restore the settings and changing the settings Canceling The Settings If you decide not to change the UPS settings after modifying the displayed settings close the program usin
9. ry default corresponds to the model All models are capable of being used as 50Hz or 60Hz systems e For typical applications Auto Sensing 50 or 60Hz Bypass Enabled or Auto Sensing 50 or 60Hz Bypass Disabled should be selected according to the application The UPS will auto sense the utility frequency when first plugged in and set the nominal frequency to match e For some special applications For some special applications the UPS is required to be used as a frequency converter In this application the following options are available Frequency Converter 50Hz Bypass Disabled or Frequency Converter 60Hz Bypass Disabled Frequency Converter 50Hz Bypass Disabled mode will provide 50Hz UPS output from any qualified commercial power Frequency Converter 60Hz Bypass Disabled mode will provide 60Hz UPS output from any qualified commercial power AA Note Frequency Converter 50Hz Bypass Disabled or Frequency Converter 60Hz Bypass Disabled mode disables the Bypass If for any reason the UPS inverter is unable to power the load the alternate bypass to utility power will not be available and power will be removed from any load Audible alarm control Enable Audible Alarm Control if checked the audible alarms are enabled Enable Audible Alarm Control if unchecked the audible alarms are disabled Options Tab Selectthe Options Tab as shown in Figure 4 3 GXT3 Configuration Program User Man
10. t the v Refresh OK Cancel Apply Factory Setting Figure 4 2 Selecting the output L N voltage GXT3 Configuration Program User Manual 5 4 2 Chapter4 Tabs LJ Notes 1 For the GXT3 Dual Inverter models this sets the L1 N and the L2 N nominal voltage 2 The L1 L2 voltage is dependent upon the phase angle of the input utility and is auto detected when power is first applied 3 For the GXT3 230 volt single inverter model only those voltages supported by the UPS will be displayed L N reverse detection The L N reverse detection is only for the 120V UPS Proper wiring of the receptacle powering the UPS is critical for safety EMI suppression and surge suppression The UPS checks the outlet when first plugged in e Enable L N reverse detection is checked When the box of Enable L N Reverse Detection 120V UPS only is checked alarm of L N reverse will be enabled Ifthe Line Neutral is reversed or the ground is missing the UPS will not start If a problem is detected after the UPS is started the UPS will continue to operate butthe AC INPUT LED will flash In this situation the improperly wired receptacles should be immediately repaired before the UPS is put into service e Enable L N reverse detection is unchecked When the box of Enable L N Reverse Detection 120V UPS only is unchecked alarm of L N reverse will be disabled Frequence selection The UPS is nomally designed for 50Hz or 60Hz operation The facto
11. tallation file e AUSB cable included in the UPS accessory package e Ahost computer with the Windows 20000 or later based operating system GXT3 Configuration Program User Manual 1 2 1 Chapter 2 Communication Chapter 2 Communication This chapter details how to establish communication link with the UPS including connecting the USB cable starting the program and communicating with the UPS Connecting The USB Cable A USB cable is included in the UPS accessory package To connect the USB cable 1 Connect one end of the USB cable to the USB port on the UPS 2 Connect the other end of the USB cable to the USB port on the host computer oo Note If an optional communication card has been installed in the UPS Intelislot port the card must be removed while using the program 2 2 Starting The Program To start the program 1 Place the configuration program CD into the CD driver of the host computer 2 Click the Emerson UPS GXT3 Tool exe file in the CD driver to start the program 2 3 Communicating With The UPS After starting this program if a qualified UPS is found the program window will dis play the UPS model if the configuration program fails to read data from a qualified UPS an error message will be displayed as shown in Figure 2 1 Communication Error A There is a communication error Please check the following 1 Verify the USB cable is connected securely between the computer and the UPS 2 Ve
12. ttery test periodically If enabled the value of Auto Battery Test Time can be selected from 7 14 21 and 28 days Battery cabinets If additional batteries are attached to the UPS accurate battery runtime estimates are possible if the number of External Battery Cabinets is entered in the textbox of Battery Cabinets The UPS is designed to operate with up to four external battery packs or four long runtime LRT battery packs Auto battery test In some applications it may be preferable to disable the automated periodic battery test Uncheck the Enable Auto Battery Test box to disable the periodic battery test Auto restart The UPS will provide computer grade power during power outages If input power is unavailable for an extended time the UPS will shut down when batteries are depleted or a shutdown signal is sent by the computer operating system to limit battery depletion communication data or contact closure If Auto Restartis enabled checkmark in the box of Enable Auto Restart the UPS will restart when input power is restored If the UPS turns off power to the load for any other reason manual restart is required See Options tab for exceptions Uncheck the Enable Auto Restart boxto disable Auto Restart Auto shutdown Ifthe UPS has reached the Low Battery warning level the UPS will either continue to shutdown or retum to Utility when the Utility power returns dependent on the setting of Enable Auto Shutdown If Enable Auto S
13. ttings ii 3 Chapter4 Taiana AA AA A A Aeon 5 UPS TA unas lali da 5 A 2 Options Tai AA AA 6 43 Batlle Tab cian A ee T 7 4d ABOUT Taba data A dat Lo td al ln inde de e N de ad T 9 Chapter 1 Introduction Chapter 1 Introduction Welcome to the GXT3 configuration program program for short This program is used to modify the settings of the UPS This program is compatible with UPS models beginning with GXT3 or S4K2U as in GXT3 3000RT120 or S4K2U1000C This chapter details the features and requirements of this program 1 1 Features This program has the following features e Select output voltage e Disable Auto Restart O Disable the Line Neutral Reversed Missing Ground receptacle wiring alarm 120Vac models only e Select frequency converter operation with a fixed output frequency of 50 Hz or 60Hz e Enable or disable the audible alarm e Set the Low Battery Warning alam time from 2 to 30 minutes e Enable or disable the Auto Battery test e Enable or disable the Auto Restart function e Set the Auto Battery test interval to 7 14 21 or 28 days e Selectthe number of external battery cabinets connected to the UPS to provide additional runtime e Modifying the shutdown setting of pin 1 8 2 Any Mode Shutdown 1 2 Requirements This program requires the following elements e AUPS with its model beginning with GXT3 or S4K2U as in GXT3 3000RT120 or S4K2U1000C e Aconfiguration program CD or ins
14. ual 4 3 Chapter 4 Tabs 7 ES Emerson UPS GXI3 Tool Battery About EMERSON CAUTION The UPS must be in Standby Mode for the settings to take effect Communication Interface Port Pin1 amp 2 Remote shutdown in Any Mode Must hardwire to the terminal block on rear panel of the UPS Output Enabling Options After Any Mode Shutdown Activation Disable Output Manual Restart Only Press the start button on the control panel to restart UPS after removing the Pin 1 amp 2 shutdown connection Auto Enable Output Automatically Removing the Pin 1 amp 2 shutdown connection will allow the UPS output to be automatically restored Any Mode Shutdown Default Any Mode Normally Open Connect Any Mode Shutdown to Common to disable UPS output Inverted Any Mode Normally Closed Open Any Mode Shutdown to Common to disable UPS output Help Menu For particular industrial applications and special computer applications the UPS may be monitored and controlled using external voltages and relay contact signals Retresh OK Cancel Apply Factory Setting Figure 4 3 Options Tab co Note In the Options Tab the UPS must be in Standby mode for the setting to take effect Disable output manual restart only For particular industrial applications and special computer applications the UPS maybe monitored and controlled using external voltages and relay contact signals An Any Mode Shutdown command can be activated on the
15. ue is successfully saved the message will be displayed as shown in Figure 3 1 Restart UPS The changes have been saved and will take effect after the UPS restarts 1 Close the program 2 Press the ON button on the front panel of the UPS Figure 3 1 The changes are saved GXT3 Configuration Program User Manual Chapter 3 Operation Oo Note At this time if the UPS is already ON you do not need to restart it Changes rejected When the Apply or OK button is selected to transmit new settings on the UPS Tab or Options Tab the UPS must be putin the Standby mode or the changes will be rejected and the error message will be displayed as shown in Figure 3 2 Standby Mode Error Critical Error The changes were not saved The UPS must be in Standby Mode to change any settings on the UPS and Options Tabs Standby Mode is when the UPS has only input power On the front panel of the UPS only the AC input indictor will be illuminated Close the program put the UPS in Standby mode and try again Figure 3 2 The changes are rejected At this point you should put the UPS to the Standby mode If the UPS is in Normal Mode operation press the OFF button once to put the UPS into Bypass Mode Once the UPS is in Bypass Mode operation press and release the OFF button two distinct times for about a second each time to place the UPS in Standby mode Partial save If the UPS is notin the Standby mode and changes from bot