Home

Crane EE-5063 humidifier

image

Contents

1. Crane Adorable Humidifiers INSTRUCTION WWANUIALL 1 GALLON 3 78 LITER ULTRASONIC HUMIDIFIER MODEL EE 5063 A i aa PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS APPLIANCE TABLE OF CONTENTS Table of Contents General Safety Instructions List of Main Parts P 4 Tech Specifications Contents of Packaging Operation and Use P 5 8 Service Centre Information A I MPORTANT SAFETY INSTRUCTI ONS INTRODUCTION Thank you for purchasing our CRANE Ultrasonic Humidifier Each unit has been manufactured to ensure safety and reliability Before using the humidifier for the first time please read the instructions carefully and keep them for further reference WARNING READ AND SAVE THESE INSTRUCTIONS Failure to follow all the instructions listed below may result in electric shock fire and or serious personal injury 1 10 11 12 13 Do not carry water tank by handle when it is filled with water It is advisable to carry filled water tank with two hands DO NOT operate outdoors this humidifier is intended for indoor use only Always have water in the water tank when operating the unit Use only clean cool tap water to fill the tank filtered or distilled water is recommended to avoid white dust if tap water is too hard DO NOT use hot water Be sure that the filling cap of the tank is firmly tightened Always have the mist direction nozzle and the
2. Tank 7 Vapor Outlet Channel 8 Water Tank Handle Fig 3 Water Basin 9 Nebulizer 10 Vaporization Chamber 11 Fan Vent 12 Valve Opener 13 Water Level Sensor Fig 4 Bottom of Water Tank 14 Water Tank Valve 15 Water Tank Cap 16 Vapor Outlet channel Fig 5 Water Tank Lid 17 Water Tank Lid 18 Vapor Output Slots TECHNICAL SPECIFICATIONS Rating Voltage 120V Power 45W Water Tank Capacity Approx 1 0 Gallon 3 78 Liter Output Per 24 Hours Approx 2 1 Gallon 8 Liter Run Time Per Tank Min 11 Hours Humidifying Capacity Up to 500 sq ft 46 m2 CONTENTS OF PACKAGING Instruction Manual Central Humidifier Body Water Tank Water Tank Lid with Vapor Output Slots angy If any of the above items are missing please contact our service department at 1 888 599 0992 http www crane usa com for replacement Business hours Mon Fri 9 00am 4 00pm CT OPERATION AND USE BEFORE EACH USE CHECK HUMIDIFIER PLACEMENT Place the Humidifier on an elevated non metallic waterproof surface for best performance This is to help disperse the mist in the air and prevent it from being knocked or tipped over CHECK WATER LEVEL SENSOR Make sure that the water level sensor is secured properly Refer to cleaning and maintaining water level sensor on page 9 for instructions on how to assemble water level sensor CHECK FAN VENT This fan vent is located on the bottom of the humidifier The pu
3. excessive humidity especially in small rooms leave the room door open and adjust the mist intensity control setting MAINTENANCE CAUTION Always be sure that the appliance is unplugged and switched OFF before cleaning or attempting to store the item NEVER PLUG OR UNPLUG UNIT WITH WET HANDS DO NOT leave water in water tank or water basin when unit is not in use as it may result in the build up of mineral deposits and bacteria that can inhibit the output efficiency of the humidifier PLEASE NOTE that if water remains in the water tank for more than a day or two bacterial growth is possible ALWAYS use fresh cool water when using unit NOTE When removing water tank water may accumulate under vapor lid and on the bottom of the water tank It is recommended to have a dry cloth ready to dry wet Surfaces DI SI NFECTI NG THE WATER TANK AND WATER BASIN 1 Fill water tank with 1 teaspoon of household bleach in 1 gallon of water Let Stand twenty minutes shaking vigorously with two hands every few minutes drain and rinse with clean water until the bleach smell is gone Dry with a clean cloth or paper towel 2 Wipe the water basin with a soft cloth dampened in the bleach and water solution Rinse the water basin with cool water to remove any bleach smell DO NOT IMMERSE WATER BASIN IN WATER 3 Wipe all exteriors surfaces of the base with a soft dry cloth Do not immerse the base in water or use water to clean the base An electric
4. shock may result or the humidifier may be damaged NOTE Itis recommended to clean humidifier with water and bleach solution as stated above after using the humidifier the fourth time GENERAL MAINTENANCE AND CLEANING Before any cleaning operation switch the humidifier off and unplug it ds 2 3 Always unplug the unit before cleaning The humidifier must be drained and cleaned before storing Once unplugged the exterior of the unit may be cleaned by wiping with a dry cloth Caution The ON OFF switch must be thoroughly dry before unit is again plugged into power source There may be some lime deposits in the nebulizer particular in areas with hard water Overcome this drawback by cleaning the nebulizer with water and vinegar on a soft cloth regularly as follows A Dampen a cloth with vinegar and wipe the nebulizer gently until the lime deposits disappear completely B Rub down gently with a dry cloth and remove remains of humidity C Do not rub the nebulizer with solid objects D Do not clean with chemical products When cleaning the water basin do not place the nebulizer directly under the water tap Never immerse the unit in water or let water enter the fan vent see figure 3 or any other openings It is normal for water to be in the water basin However water must not get inside the central body If this should happen take the humidifier to an authorized service center before using it again Clean the inside of the water
5. 07 2 NO ILVNYOAN ALNVYdVM 13 PLEASE DETACH THIS SECTION AND RETURN IT WITH YOUR PRODUCT WARRANTY CARD Ultrasonic Humidifier In case you find this product to be defective please proceed as follows A within 90 days of purchase return the product to your retailer for a refund B After 90 days and within the warranty period send the product freight prepaid to our service center To avoid transport damages please send the product in the original packaging In return you will receive your repaired item a new product or a refund at the service center s discretion This Ultrasonic Humidifier was tested and meets our stringent quality Standards This product is warranted to be free from manufacturing defects in original materials including original parts and workmanship for 1 year with proof of purchase Please fill in your details below and send it together with the product and purchase receipt Please read the Limited Warranty conditions mentioned in this instruction manual Customer Name Street City State ZIP Code Model Style Purchase Date Description of Defect Service Center Address Crane USA Inc Tel 1 888 599 0992 Business Hours Mon Fri 9 00am 4 00 pm CT Website http www crane usa com 1800 Nicholas Blvd Elk Gove Village Illinois 60007 GQuYdvV ALNVdadVvmM
6. IONS 2 GENERAL SAFETY INSTRUCTIONS AN WARNING Read and understand all instructions Failure to follow all instructions listed below may result in electric shock fire or serious personal injury The warnings s cautions and instruction discussed in this instruction manual cannot cover all possible L RA conditions and situations that may occur It must be understood by the operator that common sense and caution are a factor which cannot be built into this product but must be supplied by the operator THIS HUMIDIFIER IS NOT A TOY Do not let your child play with this appliance Serious injury and electrocution might be possible This appliance has to be operated by an adult only Children should be supervised to ensure that they do not play with the humidifier SAVE ALL INSTRUCTIONS CAUTI ON A short power supply cord is provided to reduce the risk of personal injury resulting from becoming entangled in or tripping over a longer cord Extension cords are available from local hardware stores and may be used if care is exercised in their use If an extension cord is required special care and caution is necessary Also the cord must be 1 marked with an electrical rating of 125 V and at least 13 A 1625 W and 2 the cord must be arranged so that it will not drape over the countertop or tabletop where it can be pulled on by children or tripped over accidentally ELECTRI C POWER If electric circuit is overloaded with other a
7. min White dust appears and settles outside the Area tap water may have too many humidifier minerals change to filtered or distilled water Use Crane filter cartridge to eliminate minerals 10 SERVICE CENTER If you have any question in regards to the operation of this appliance or are in need of a Spare part please contact our service center at Crane USA Inc Tel 1 888 599 0992 Business Hours Mon Fri 9 00am 4 00 pm Ct Website http www crane usa com 1800 Nicholas Blvd Elk Gove Village Illinois 60007 ENVIRONMENTAL PROTECTION OY If the appliance should no longer work at all please make sure that it is disposed in an BY environmentally friendly way by handing it into a public collection point Please do not put it with your household waste LIMITED WARRANTY Thank you for purchasing a top quality Crane product This Ultrasonic Humidifier was tested and meets our stringent quality standards This product is warranted to be free from manufacturing defects in original materials including original parts and workmanship for 1 year with proof of purchase The warranty is void if the defect is due to accidental damage misuse abuse neglect improper repair or alteration by unauthorized persons or failure to follow operation instructions provided with the product This warranty does not apply to commercial use The warranty is non transferable and applies only to the original purchase and does not extend to subsequen
8. mist chamber in place while the unit is operating Place the mist direction nozzle so it aims away from children walls furniture and electrical appliances Use only a 110 120VAC outlet ALWAYS plug and unplug unit with dry hands Never operate the unit with a damaged cord or plug Always place the unit on a smooth flat level surface and away from direct Sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or move the unit Do not add medication of any type into the nozzle base or water tank Do not cover any openings on the unit or insert objects into any openings The unit should not be left unattended in a closed room as the air could become saturated and leave condensation on walls or furniture Leave room door partly open When cleaning the inside of the unit keep water away from the air outlet fan vent see FIG 3 The exterior may be wiped with a damp cloth except the electrical controls only when the unit is off and unplugged Humidifier requires regular cleaning Refer to cleaning instructions Do not tilt or tip the unit or attempt to empty or fill it while it is in operation Do not use a detergent to clean any parts of the unit that contain water Always use a few drops of bleach with water to clean humidifier Detergent film dissolved in the water supply can interfere with the output of the unit SAVE THESE INSTRUCT
9. n cord and turn on the unit The On Off switch is located at the turning knob see figure 1 The Power Light will turn on red In a few seconds it will switch to green indicating that enough water is in the water basin and vapor will start emitting through the openings at water tank lid 8 Use the humidity output regulator control knob to adjust the intensity of the vapor output Turning the knob clockwise will increase the moisture output turning the knob counterclockwise with reduce the moisture output see Fig 10 Fig 10 9 When the humidifier runs out of water the power light will turn red and the mist output will stop This is a safety feature to prevent the humidifier from possibly over heating and damaging the nebulizer This safety feature uses a water level sensor to stop the nebulizer once the water level sinks below the required level in the water basin Turn the humidifier off and unplug before removing and refilling the water tank Please note that the RED Power Light on the humidifier body will stay on The red light signal indicates that the humidifier is turned on and needs to be refilled INSERTING HUMIDIFIER FILTER SOLD SEPARATELY not included with your humidifier A humidifier filter is an optional accessory for your Crane Cool Mist Humidifier Filters are used to eliminate white dust caused by hard water and to reduce mold spores and bacteria that can build up in your humidifier Place humidifier filte
10. ppliances your appliances may not operate properly The appliances should be operated on a separate electrical circuit from other operating appliances POLARI ZED PLUG This appliance has a polarized plug one blade is wider than the other As a safety feature to reduce the risk of electrical shock this plug is intended to fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician Do not attempt to defeat this safety feature SAFETY WARNI NG AN Although your appliance is easy to operate for your safety the below warnings must be followed 1 Do not place the appliance near a heat source 2 Never leave the appliance unattended while connected to the electrical outlet 3 To avoid any accidents never put a hand over a steam heat vent and never cover it when the appliance is in operation 4 Use the appliance on a stable surface away from water 5 Do not unplug from the wall socket by pulling on the supply cord 6 The appliance must be unplugged A Before either filling or emptying B Before any cleaning or maintenance C After use D If it appears to be faulty THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY LIST OF MAIN PARTS PARTS DESCRIPTION Fig 1 Central Body 1 Night Light Switch On Off Switch 3 Step Regulator Control Knob Central Body with water basin Red refill Light Green Power Light Fig 2 Top of Water
11. r in humidifier as oe ere shown in Fig 10A NOTE Do not leave filter in humidifier longer than recommended time See Filter instructions Filters are not included with the humidifier and can be purchased Separately Fig 10 A SET THE CORRECT HUMIDITY OUTPUT ALWAYS PLACE THE HUMIDIFIER ON AN ELEVATED NON METALLIC WATERPROOF SURFACE FOR BEST PERFORMANCE Adjust the vapor control so that the vapor rises up and gets absorbed by the room air Do not turn on too high output as the vapor cannot be absorbed by the air and accumulates on the surface around the humidifier If the humidifier is placed near a fan or air conditioning outlet the vapor may be forced down by the foreign air stream Change the location of the humidifier or reduce the output of the other room conditioning appliances correct wrong A NOTE ABOUT HUMIDITY It is best to keep the humidity level at about 30 50 percent of relative humidity The comfort level of humidity will vary from room to room and with changing room conditions n cold weather windows and even some walls may fog or develop frost from excessive indoor humidity If this occurs reduce the mist intensity setting to avoid damage from condensed water dripping on windowsills Too much humidity in the room may allow moisture to accumulate on surfaces where bacteria and fungi can grow Moisture that gathers may also damage furniture and walls especially wallpaper To eliminate
12. rpose of the Fan Vent is to blow the cool mist through the vapor outlet slots It is important that this part is kept clean and free of obstructions We recommend checking the fan vent before using this item i e lint paper Do not place Humidifier on top of a towel or a carpeted surface The air vent on the bottom may become blocked and overheat the humidifier CAUTION DO NOT operate the humidifier without water in the water tank DO NOT plug in the cord with wet hands electric shock could happen ASSEMBLY DO NOT use hot water Use cool tap water DO NOT add any medication to other additives to the water DO NOT pour water into Vapor Outlet Channel part 7 Fig 2 on page 4 4 Replace the water tank cap aligning the threads on the J fa Lift the water tank off the central body Turn over the water tank and unscrew the water tank cap at the bottom of the tank by turning it counterclockwise See Fig 6 Fill water tank with cold water do not fill all the way to the rim See Fig 7 Note To avoid possible white dust due to hard water it is recommended to use distilled water tank with the threads on the cap and turn it clockwise See Fig 8 Turn the tank over holding it by the top handle and place it on the central body making sure it fits perfectly Place the water tank cap with output slots on top of the water tank see Fig 9 Fig 9 Plug the power cord into a wall socket do not use extensio
13. t owners of the product Liability under this warranty is limited to repair replacement or refund In no event shall liability exceed the purchase price paid by the purchaser of the product Under no circumstances shall there be liability for any loss direct indirect incidental special or consequential damage arising out of in connection with use of this product This warranty Is valid only in the United States of America This Warranty gives you specific legal rights However you may have other rights that vary from State to state Some states do not allow limitation on implied warranties or exclusion of consequential damages therefore these restrictions may not apply to you In case you find this product to be defective please proceed as follows A within 90 days of purchase return the product to your retailer for a refund B After 90 days and within the warranty period send the product freight prepaid to our service center To avoid transport damages please send the product in the original packaging In return you will receive your repaired item a new product or a refund at the service center s discretion Please fill out the Warranty Card and send it together with the product and purchase receipt To arrange pick up of the defective item please call our service center Crane USA Inc Tel 1 888 599 0992 Business Hours Mon Fri 9 00am 4 00 pm CT Website http www crane usa com 1800 Nicholas Blvd Elk Grove Village Illinois 600
14. tank at least once a week as follows A Fill the tank with clean water adding a few drops of bleach Close the tank completely with its cap and shake by holding the tank with both hands Do not hold by handle while shaking the tank B Rinse thoroughly Note Water accumulated over long periods may create bacteria and mildew fungus It is important to remove the water in the humidifier tf the humidifier is not being used Always use fresh clean water when filling the water basin 9 To clean the water float remove the plastic cap on the pin by pulling it up see Fig 12 Remove the water float and cap and clean by wiping the parts with a soft damp cloth Replace the parts by first putting the water float onto the pin and then pressing the plastic cap on the end of the pin to secure the float see Fig 13 Do not use excessive force Plastic Cap Fig 11 Fig 12 Fig 13 STORING YOUR HUMIDIFIER Allow the appliance to dry completely before storing Store the appliance in a dry location Do not place any heavy items on top of appliance during storage as this may result in possible damage of the appliance Store the cord in a clean dry location away from metal objects Always check the plug before use to assure metal items have not become attached Save the box for off season storage Make sure the tank water basin and water tank cap are thoroughly dry before storing f water is left in the unit during storage it may evapora
15. te completely and leave deposits that can prevent the unit from operating properly Leave the water tank refill cap loose to prevent the water cap see figure 4 and gasket from sticking together This will prolong the life of the gasket TROUBLE SHOOTING CAUTION DO NOT attempt to repair the motor or nebulizer yourself If the humidifier continues to not operate please call our service center see toll free number below Problem Humidifier Light is staying red and not Ensure that water level sensor is turning green assembled properly Clean water float Humidifier is working than stops Call service center and request replacement water float If humidifier does not work at all Ensure it is properly plugged into a power outlet Check that the switch is in the ON position If Power On indicator light does not come on bring to authorized service Station If there is a strange odor Clean the tank with water and vinegar or bleach and rinse with clean water Leave the tank open for some time without the cap in a cool place The power light is green but there is no Check that there is water in the tank mist being emitted Check for possible lime deposits on the water level sensor or the nebulizer see page 8 and 9 Make sure that nothing blocks the vapor output slots Check that the air vent on bottom of humidifier is not blocked Empty the humidifier and rinse the water basin with cool tap water and allow to dry for 15 to 30