Home

Moxa ICF-1150-M-SC

image

Contents

1. C ae m m ry H a 5 8 B ooo i g S 123 8 IL 70 8 8 P pea WE nan S HEDuucuuunnuuU E ICF 1150 ST s i L amp Co E co ooo HO 8 fe gt 13 66 70 8 HHHHHHEHHHBHHH nunnunnuuguununun HHHEHREUEHED Beo0o0o0o000000 Top View Front View Rotary Switch for Pull High Low Resistor OP Mode Switch u DEED ole EAI Foer pon RS 422 485 LED ATTENTION Electrostatic Discharge Warning To protect the product from damage due to electrostatic T discharge we recommend wearing a grounding device when handling your ICF 1150 series Mounting The aluminum DIN Rail attachment plate should be fixed to the back panel of the ICF 1150 when you take it out of the box If you need to reattach the DIN Rail attachment plate to the ICF 1150 make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN Rail into the slot just below the stiff metal spring STEP 2 The DIN Rail attachment unit will snap into place as shown below metel spring SN metel spring DIN Rail DIN Rail To remove the ICF 1150 series from the DIN Rail simply reverse Steps 1 and 2 above Pin Assignment a
2. or lose its signal and is not affected by short circuits power surges or static electricity Reverse Power Protection The Reverse Power Protection feature provides extra protection against accidentally connecting the power cables to the wrong terminal The converter is designed to detect automatically which power wire is positive and which is negative and then adjust the power supply accordingly 3 Way Communication The ICF 1150 series supports 2 serial ports The D sub connector is for RS 232 communication and the removable terminal block is for RS 422 or RS 485 communication The 3 ports 2 serial ports and one fiber port are completely independent When the ICF 1150 series converters receive data from any port it will send data out through the other 2 ports For example when the ICF 1150 series converters receive a command from the remote Master via the fiber port it will convert the command and transmit it via the RS 232 port and RS 422 485 port at the same time So if the user is trying to monitor a system running on the RS 485 network there is no need to use an additional RS 232 to RS 485 converter to connect the laptop computer s serial port to the RS 485 bus ATTENTION ICF 1150 is designed to receive data from one port and send data to the other ports If ICF 1150 receive data from 2 ports at the same time that may cause the data error on all the RX ports Rotary Switch for Pull High Low Resistor Setting Since
3. the RS 485 port can support multi drop connection or daisy chain connection system engineers can connect meters RTUs readers or many other devices together on the same bus The impedance of the data line will rise according to the number of serial devices on the same bus To get the system working the ICF 1150 has a setting for tuning the pull high low resistor Just turn the dial to find the best resistor value for the system without removing the ICF 1150 from the DIN rail The default settings are 1K for both switches Pull High Low Resistor Position 0 1 2 3 4 3 6 7 8 9 Ohm 150K 10K 4 7K 3 3K IK 909 822 770 500 485 DIP Switch for Selectable Terminator The termination resistor for many products of this type is set by a jumper located inside the product s casing To disable or change the resistor s strength the user must open the casing to reset the jumper Moxa offers a more user friendly solution that allows users to set the termination resistor with a DIP switch located outside the ICF 1150 converter s casing No Configuration Required for Baudrate Settings The ICF 1150 works under any baudrate from 50 bps to 921 6 Kbps The ICF 1150 simply converts the signal back and forth between serial RS 232 RS 422 or RS 485 and fiber Since the ICF 1150 does not need to interpret the signal it does not need to know the baudrate of the transmitting device For this reason
4. ICF 1150 Series Quick Installation Guide First Edition November 2008 MOXA 2008 Moxa Inc All rights reserved Reproduction without permission is prohibited F1 4 No 135 Lane 235 Pao Chiao Rd Shing Tien City Taipei Taiwan R O C TEL 886 2 8919 1230 P N 1802011500010 Overview Introduction The ICF 1150 series fiber converters are equipped with a multiple interface circuit that can handle RS 232 and RS 422 485 serial interfaces as well as multi mode or single mode fiber The ICF 1150 series converters are used to extend serial transmission distance up to 5 km ICF 1150 M with multi mode fiber or up to 40 km ICF 1150 S with single mode fiber Why Convert Serial to Fiber Fiber communication not only extends the communication distance but also provides many advantageous features IMMUNITY FROM ELECTRICAL INTERFERENCE Fiber is not affected by electromagnetic interference or radio frequency interference It provides a clean communication path and is immune to cross talk INSULATION Optical fiber is an insulator the glass fiber eliminates the need for using electric currents as the communication medium SECURITY Fiber cannot be tapped by conventional electric means and is very difficult to tap into optically Furthermore radio and satellite communication signals can be captured easily for decoding RELIABILITY amp MAINTENANCE Fiber is immune to adverse temperature and moisture conditions does not corrode
5. a 5 RS 232 Null TxD RxD Null GND Null Null Null Vjola HD i BY WW Pope RS 422 4 wire RS 485 2 wire RS 485 1 GND GND GND 2 Rx Rx Data 3 Rx Rx Data 4 Tx Tx 5 Tx Tx Fiber Cable SC Port Pinouts SC Port to SC Port Cable Wiring A A L VE I XE n el B B p Cable Wiring Tx Q E A A i ST Port Pinouts ST Port to ST Port Cable Wiring A A arm t qi unn ES B Cable Wiring A A B B ATTENTION This is a Class 1 laser LED product Do not stare into the laser beam Switch Settings There are 4 DIP switches on the front panel of the ICF 1150 Setting Switch 1 Switch 2 RS 422 ON OFF 2 wire RS 485 OFF ON 4 wire RS 485 OFF default OFF default Fiber Mode Switch 3 Ring Mode ON Point to Point mode OFF default 120Q Terminator Switch 4 Enable ON Disable OFF default ATTENTION For Fiber Ring Users If the Rx LEDs of the converter glow continuously remove the fiber cable and connect again then the system will not have the same condition NOTE Ring Mode can only be used for half duplex applications LED Indicators There are 3 LEDs on the front panel of the ICF 1150 LED Color Function PWR G
6. ns W x D x H Material Gross Weight Regulatory Approvals CE FCC TUV EMI EMS Free fall MTBF ICF 1150I S M SC ST 163 mA 12V 30 3 x 70 x 115 mm Aluminum 1 mm 135g Class B Part 15 sub Class B EN 60950 1 EN55022 1998 Class B EN61000 4 2 ESD Criteria B Level 4 EN61000 4 3 RS Criteria A Level 3 EN61000 4 4 EFT Criteria B Level 4 EN61000 4 5 Surge Criteria A Level 3 EN61000 4 6 CS Criteria A Level 3 En61000 4 8 PFMF Criteria A Level 5 IEC 60068 2 32 792085 hrs Technical Support Contact Information www moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 10 6872 3958 Moxa Asia Pacific Tel 886 2 89 19 1230 Fax 886 2 89 19 1231 9
7. reen Steady ON Power is ON Fiber Tx Green When sending serial data from the fiber port Fiber Rx Yellow When receiving data from the fiber port Specifications Serial Communication Signals for RS 232 Signals for RS 422 Signals for 4 wire RS 485 Signals for 2 wire RS 485 Baudrate ESD protection Fiber Communication Connector type Distance Support Cable Wavelength TX Output RX Sensitivity Point to Point Transmission Multi drop Transmission Environmental Operating Temperature Storage Temperature Power Input Power Voltage Power Line Protection Reverse Power Protection Over Current Protection Power Consumption TxD RxD SGND TxD TxD RxD RxD SGND TxD TxD RxD RxD SGND Data Data SGND 50 bps to 921 6 Kbps 15 KV ESD ST or SC Single mode fiber for 40 km Multi mode fiber for 5 km 8 3 125 8 7 125 9 125 or 10 125 um single mode 50 125 62 5 125 or 100 140 um multimode ICF 1150 S 1310 nm ICF 1150 M 850 nm ICF 1150 S 5 dBm ICF 1150 M 5 dBm ICF 1150 S 25 dBm ICF 1150 M 20 dBm Half or Full duplex Half duplex fiber ring 0 to 60 C 32 to 142 F 5 to 95 RH 40 to 85 C 40 to 167 F for T Model 40 to 85 C 4 to 185 F 5 to 95 RH 12 to 48 VDC 4 KV Burst EFT EN61000 4 4 2 KV Surge EN61000 4 5 Protects against V V reversal Protects against 2 signals shorted together 1 1A ICF 1150 S M SC ST 127 mA 12V 8 Mechanical Dimensio
8. the ICF 1150 does not have any DIP switches or jumpers for setting the baudrate Ring Mode To allow one half duplex serial device to communicate with multiple half duplex devices connected to a fiber ring you should configure the ICF 1150 for ring mode by setting DIP switch SW3 to the On position The Tx port of a particular ICF 1150 unit connects to the neighboring converter s Rx port to form the ring Note that when one node transmits a signal the signal travels around the ring until it returns back to the transmitting unit which then blocks the signal Users should ensure that the total fiber ring length is less than 100 km when using either single mode models or multi mode models Features Ring or Point to Point transmission Extend RS 232 422 485 transmission distance gt up to 40 km with single mode ICF 1150 S series gt upto 5 km with multi mode ICF 1150 M series Support baudrate up to 921 6 Kbps Provide 3 way galvanic isolation for I models e Wide operating temperature from 40 to 85 C for T models Package Checklist Before installing the ICF 1150 verify that the package contains the following items JCF 1150 Fiber Converter Quick Installation Guide Warranty Card NOTE Please notify your sales representative if any of the above items are missing or damaged Mounting Dimensions unit mm ICF 1150 SC

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SGH-F300 Manual de utilizare  

Copyright © All rights reserved.
Failed to retrieve file