1. Literature kit containing Product documentation Smart UPS RT User Manuals CD Safety information Warranty information Hardware 4 Pan head screws for securing rail cleats to unit 8 Flat head screws for securing rack mount or tie brackets to unit 20 Ornamental screws 4 for securing unit to rack 16 for securing tie brackets in stack configuration 2 Cage nuts used in rack mount installation 2 Rack mount brackets 2 Rail cleats 2 Tie brackets for securing units in stack configuration SURT192RMXLBP2 SURT192RMXLBP2J User Manual 4 Accessories Install accessories prior to connecting power to the UPS Refer to the APC Web site www apc com for available accessories Specifications Environmental Specifications Physical Specifications Temperature Operating 0 to 40 C 32 to 104 F This unit is intended for indoor use only Select a location sturdy enough to handle the weight Do not operate unit where there is excessive dust or temperature or humidity are outside specified limits Environmental factors impact battery life High temperatures poor utility power and frequent short duration discharges will shorten battery life Storage 15 to 30 C 5 to 86 F charge UPS battery every six months 30 to 70 C 86 to 158 F charge UPS battery every three months Maximum Elevation Operating 3 000 m 10 000 ft Storage 15 000 m 50 000 ft Humidity
2. 0 to 95 relative humidity non condensing Weight Refer to the Safety Guide supplied with this unit for lifting guidelines Battery Pack with eight battery modules 181 kg 400 lbs without battery modules 44 kg 96 lbs each battery module 17 kg 38 lbs Maximum number of external battery packs XLBPs 10 Combined weights of UPS battery pack and all XLBPs installed in a rack must not exceed rack weight limits Dimensions Battery Pack width 482 mm 19 in with rack mount brackets 432 mm 17 in without rack mount brackets height 263 mm 10 in depth 739 mm 29 in with PDU 720 mm 28 in without PDU SURT192RMXLBP2 SURT192RMXLBP2J User Manual 5 Installation Batteries must be removed from battery pack and XLBPs prior to installing units in stack or rack mount configuration Refer to instructions on packaging for details on removing batteries from battery pack and XLBPs Always place the UPS above the battery pack and XLBPs Stack configuration Rack mount configuration Read the Safety Guide included in the package and refer to Physical Specifications in this manual before installing the UPS Install rails in rack For details on rail installation refer to instructions included in rail kit package Total stack configuration height must NOT exceed 18U The UPS and battery pack together equal 12U Adding one XLBP creates an 18U configuration For detailed instructions on installing batteries and battery
3. doors refer to Rack mount configuration in this manual Install tie brackets Four ornamental screws supplied in battery pack package must be used to secure each tie bracket to the units su0182a 8x 8x 8x su0167a 4x 4x external battery pack UPS su0166a 2x 2x external battery pack UPS Install rack mount brackets Four flat head screws must be used to secure each rack mount bracket to unit Install rail cleats Two pan head screws must be used to secure each rail cleat to unit SURT192RMXLBP2 SURT192RMXLBP2J User Manual 6 Install units in rack Secure UPS battery pack and XLBP in rack using cage nuts and ornamental screws included in package Four ornamental screws and two cage nuts must be used to secure each unit A cage nut must be used in the top hole of each rack mount bracket when securing the unit in the rack The bottom hole of each rack mount bracket can be secured using an ornamental screw in the threaded hole Install and connect battery modules Connect all eight battery modules Failure to do so may cause equipment damage Replace battery compartment doors Tighten screws to secure battery compartment doors Install bezels There is a single latch on each side of the UPS bezel There are two latches on each side of the battery pack and XLBP bezels su0183a 4x 4x su0184a 7 holes 7 holes su0173a su0185a su0186a SURT192RMXLBP2 SURT192RMXLBP2J User Manu
4. the range of the intended use THERE ARE NO WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE OF PRODUCTS SOLD SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH APC DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE APC EXPRESS WARRANTIES WILL NOT BE ENLARGED DIMINISHED OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF APC RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES THE WARRANTIES SET FORTH ABOVE CONSTITUTE APC SOLE LIABILITY AND PURCHASER EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES APC WARRANTIES EXTEND ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES IN NO EVENT SHALL APC ITS OFFICERS DIRECTORS AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT SPECIAL CONSEQUENTIAL OR PUNITIVE DAMAGES ARISING OUT OF THE USE SERVICE OR INSTALLATION OF THE PRODUCTS WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT IRRESPECTIVE OF FAULT NEGLIGENCE OR STRICT LIABILITY OR WHETHER APC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES SPECIFICALLY APC IS NOT LIABLE FOR ANY COSTS SUCH AS LOST PROFITS OR REVENUE LOSS OF EQUIPMENT LOSS OF USE OF EQUIPMENT LOSS OF SOFTWARE LOSS OF DATA COSTS OF SUBSTITUENTS CLAIMS BY THIRD PARTIES OR OTHERWISE NO SALESMAN EMPLOYEE OR AGENT
5. this manual The XLBP LED remains illuminated A potential hardware fault exists Contact APC refer to Service in this manual XLBP LED does not illuminate On start up the XLBP LED does not illuminate Normal operation No action is necessary SURT192RMXLBP2 SURT192RMXLBP2J User Manual 9 Battery module and pair identification The display interface will reference XLBP configuration in the following manner Contact Information APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways Refer to the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information www apc com support Global support searching APC Knowledge Base and using e support Contact an APC Customer Support center by telephone or e mail Local country specific centers go to www apc com support contact for information Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support External Battery Pack Negative BattPair 1 Positive BattPair 2 Module 1 Module 2 Module 3 Module 4 Negative BattPair 3 Positive BattPair 4 Module 5 Module 6 Module 7 Module 8 su0178a SURT19
6. 2RMXLBP2 SURT192RMXLBP2J User Manual 10 Maintenance Transport and Service Replace battery modules This UPS has easy to replace hot swappable battery modules Replacement is a safe procedure isolated from electrical hazards You may leave the UPS and connected equipment on during the replacement procedure Once the batteries are disconnected the connected equipment is not protected from power outages Refer to the appropriate replacement battery user manual for battery module installation instructions See your dealer or contact APC at www apc com for information on replacement battery modules Service If the unit requires service do not return it to the dealer Follow these steps 1 Review the problems discussed in Troubleshooting in the UPS manual to eliminate common problems 2 If the problem persists contact APC Customer Support through the APC Web site www apc com Note the model number of the unit the serial number located on the back of the unit and the date purchased If you call APC Customer Support a technician will ask you to describe the problem and attempt to solve it over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA If the unit is under warranty repairs are free Procedures for servicing or returning products may vary internationally Refer to the APC Web site for country specific instructions 3 Pack the unit in its original pac
7. 990 2485B 02 2009 Smart UPS RT External Battery Pack Stack Rack Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English SURT192RMXLBP2 SURT192RMXLBP2J User Manual 3 Introduction About this UPS The American Power Conversion APC SURT192RMXLBP2 external battery pack XLBP connects to an APC Smart UPS RT greater than 10 kVA Together these units provide extended protection for electronic equipment load from utility power blackouts brownouts sags and surges The UPS and the XLBP together provide continuous power from the batteries until utility power returns to safe levels or the batteries are fully discharged The UPS and the battery pack are packaged separately Unpack package contents Read the Safety Guide before installing the unit Inspect the battery pack upon receipt Notify the carrier and dealer if there is damage The packaging is recyclable save it for reuse or dispose of it properly Check the battery pack package contents NOTE The model and serial numbers are located on a small rear panel label For some models an additional label is located on the chassis under the front bezel External battery pack Front bezel Battery compartment doors Ground wire Four tie brackets Sixteen ornamental screws Rail Kit Four ornamental screws Two cage nuts Two rail cleats Four pan head screws Two rack mount brackets Eight flat head screws
8. OF APC IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY WARRANTY TERMS MAY BE MODIFIED IF AT ALL ONLY IN WRITING SIGNED BY AN APC OFFICER AND LEGAL DEPARTMENT Warranty claims Customers with warranty claims issues may access the APC customer support network through the Support page of the APC Web site www apc com Select your country from the country selection pull down menu Open the Support tab at the top of the Web page to obtain contact information for customer support in your region
9. Verify that display interface shows CHRG battery charge is greater the 95 4 Verify that display interface shows Load is greater than 5 x the number of external battery packs installed 5 Verify that display interface shows Runtime is greater than 00hr3 3m 6 Perform a self test as described in Smart UPS user manual If the LED remains illuminated after performing these steps refer to the troubleshooting table below LED Activity Possible Cause Corrective Action after a Self Test is Performed XLBP LED illuminates briefly On start up the XLBP LED will illuminate and blink within the first minute The XLBP is establishing communication with other components of the system The XLBP is conducting a normal periodic self test Normal operation No action is necessary XLBP LED remains illuminated NOTE Read the information and perform steps outlined in the list above prior to performing the actions listed in this table XLBP LED is blinking slowly one blink per second One or more battery modules are not connected Check that all battery connections in the UPS XLBP configuration are secure Replace battery modules XLBP LED is blinking rapidly three blinks per second A communication fault exists check cable connections Check that all cable and battery connections in the UPS XLBP configuration are secure Testing beyond the self test may be required Contact APC Refer to Service in
10. al 7 Connect UPS battery pack and XLBP Units may vary in appearance from those depicted in this manual su0189a su0208a Remove safety covers on battery pack and XLBP s su0188a su0190a su0191a UPS Battery pack with PDU installed XLBP with no PDU installed Connect batteries as shown Rotate safety covers Re install safety covers Ensure all battery connectors used and unused have safety covers installed su0187a Connect ground wires as shown Ground Ground Ground Thumb screw Thumb screw amp Prior to connecting the battery pack to the UPS the safety cover on the UPS battery connector must be adjusted Loosen two thumb screws on safety cover Slide safety cover so that battery connectors are exposed Securely engage battery connectors Slide safety cover to lock battery connectors in place Tighten thumb screws SURT192RMXLBP2 SURT192RMXLBP2J User Manual 8 Operation Battery LED The battery LED is located on the front bezel of the XLBP During normal operation the LED is not illuminated On start up the XLBP LED will illuminate and blink within the first minute The LED should then extinquish If the LED remains illuminated perform the following steps to extinguish the LED 1 Allow unit to run for two continuous hours without removing or installing batteries 2 Verify that display interface shows actual number of XLBPs connected 3
11. ears from the date of purchase The obligation of APC under this warranty is limited to repairing or replacing at its sole discretion any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way Repair or replacement of a defective product or part thereof does not extend the original warranty period Any parts furnished under this warranty may be new or factory remanufactured Non transferable warranty This warranty extends only to the original purchaser who must have properly registered the product The product may be registered at the APC Web site www apc com Exclusions APC shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user or any third person misuse negligence improper installation or testing Further APC shall not be liable under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical voltage or connection inappropriate on site operation conditions corrosive atmosphere repair installation start up by non APC designated personnel a change in location or operating use exposure to the elements Acts of God fire theft or installation contrary to APC recommendations or specifications or in any event if the APC serial number has been altered defaced or removed or any other cause beyond
12. kaging If this is not available Pack the unit carefully to avoid damage in transit Never use Styrofoam beads for packaging Damage sustained in transit is not covered under warranty 4 Always DISCONNECT THE UPS BATTERY before shipping in compliance with U S Department of Transportation DOT and IATA regulations The battery s may remain in the unit 5 Mark the RMA on the outside of the package 6 Return the unit by insured prepaid carrier to the address given to you by Customer Support Entire contents copyright 2008 American Power Conversion Corporation All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo Smart UPS and PowerChute are trademarks of American Power Conversion Corporation All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only Be sure to deliver the spent battery s to a recycling facility or ship it to APC in the replacement battery packing material SURT192RMXLBP2 SURT192RMXLBP2J User Manual 11 Two Year Warranty The limited warranty provided by American Power Conversion APC in this statement of Limited Factory Warranty applies only to products you purchase for your commercial or industrial use in the ordinary course of your business Terms of warranty APC warrants its products to be free from defects in materials and workmanship for a period of two y