1. www apc com Connect Battery Back UPS ES 650 User s Guide For safety the Back UPS ES is shipped with one battery wire disconnected The UPS will not operate until the wire is connected to the touch safe battery terminal NOTE Small sparks may occur during battery connection This is normal Turn the Back UPS ES over and press in the release tab Slide the plastic battery cover off of the Back UPS RELEASE TAB BATTERY DOOR Connect Equipment p Battery Back up f Surge Protection These outlets are powered whenever the Back UPS ES is switched ON During a power outage or other utility problems brownouts over voltages these outlets will be powered for a limited time by the Back UPS ES Plug your computer monitor CD ROM drive and two other data sensitive devices such as an external disk or tape drive or Home Phoneline Networking Association HPNA device into these outlets Battery Backup Surge Protection Back UPS ES 650 E J Replace J Battery Indicator Surge Protection Power On Off Switch amp Indicator NOTE Replace Battery Indicator is only visible when illuminated Connect the red battery wire firmly to the positive battery terminal tab locks into place Insert the battery back into the compartment Slide the plastic battery cover until the release Place the Back UPS ES to avoid Direct sunlight Exc
2. seconds or the UPS is turned off Building Wiring Fault Your building wiring presents a shock hazard that should be corrected by a licensed electrician Building Wiring Fault LED red ON None UPS is unplugged or UPS is plugged into a properly wired outlet See the Troubleshooting section for additional assistance APC Back UPS and PowerChute are registered trademarks of American Power Conversion Corp All other trademarks are property of their respective owners Use the table below to solve minor Back UPS ES installation or operation problems Consult APC Online Technical Support or call APC Tro u b les h ooti n g Technical Support for assistance with problems that cannot be resolved using the table below Problem Probable Cause Solution Back UPS ES will not turn on The battery is disconnected and either power is unavailable Connect the battery see Connect Battery and ensure power is available at the wall at the wall outlet or utility power is having a brownout or outlet If battery is connected and power is unavailable the unit can be cold an over voltage condition started operated on battery power by holding the power button down until two beeps are heard Back UPS is on but Replace Battery indicator Battery is disconnected Connect the battery see Connect Battery diagram flashes and unit emits a constant tone The Power On indicator is lit and the Back T
3. arm Terminates When Power On UPS is supplying conditioned utility power to the load Power On pushbutton ON lit None Not applicable On Battery UPS is supplying battery power to the load connected to the Battery outlets Power On pushbutton ON off during beep Beeping 4 times every 30 seconds UPS transfers back to Power On operation or when UPS is turned off Low Battery Warning UPS is supplying battery power to the load connected to the battery outlets and the battery is near exhaustion Replace Battery indicator is flashing Rapid beeping every 1 2 second UPS transfers back to normal operation or when UPS is turned off Replace Battery The battery is disconnected The battery is in need of charging or is at the end of its usual life and must be replaced Replace Battery indicator is Flashing Power On and Replace Battery indicators flashing alternating Constant tone Constant tone UPS is turned off with the power switch the battery power has been completely exhausted and the UPS is waiting for utility power to return to normal Overload Shutdown During On Battery None Constant tone UPS is turned off with operation a battery power supplied outlet the power switch overload was detected Sleep Mode During On Battery operation None Beeping once every 4 Utility power is restored seconds or if utility power is not restored within 32
4. due to assigned asset tags and set depreciation Total Amperage 8 outlets 12 Amps including UPS output schedules must declare such a need at first contact with APC Technical Support APC Voltage On Battery 115 Vrms 8 step approximated sine wave will ship the replacement unit once the defective unit is received by the repair B rey department or cross ship upon the provision of a valid credit card number The Frequency On Battery 30 60 Hz 1 Hz customer pays for shipping to APC and APC pays ground freight transportation costs pp Transfer Time 6 ms typical 10 ms maximum back to the customer Protection and AC Surge Protection Full time 375 joules Filter Se rvice Phone fax DSL Surge Single line 2 wire Protection Please DO NOT RETURN Back UPS ES to the place of purchase under any circumstances Cable CATV DSS Surge One Coax Input Output Protection 1 Consult the Troubleshooting section to eliminate common problems Network Surge Protection 410 100Base T Ethernet 2 Verify the battery is connected see Connect Battery and that the Circuit Breaker is EMI RFI Filter Full time not tripped see Troubleshooting section at If you still have problems or questions please contact APC via the internet or at one of AC Input Resettable circuit breaker the phone numbers listed below Battery Type Sealed maintenance free lead acid 3 Before contacting APC please be sure to record the date purchased UPS model Average Life 3 5 years depending on
5. essive heat computer s USB Port Excessive humidity or contact with fluids lt M F d Plug the Back UPS ES power cord directly into a wall outlet not into a surge protector or power strip Connect Computer Cable The supplied cable and software provide automatic file saving and shutdown of the operating system in the case of a sustained power outage Connect the cable to the Data Port of the Back UPS ES Connect the other end of the cable to the USB port on your computer The software will automatically find the Connect Modem Phone DSL Fax 10 100Base T HPNA Cable Modem CATV or DSS to Surge Protection The Back UPS protects a single line 2 wire phone including Digital Subscriber Line DSL Home Phoneline Networking Association HPNA type equipment modem 10 100 Base T Ethernet or fax machines from surges when connected through the UPS as shown in the drawing below The UPS also protects a cable modem CATV converter or DSS receiver from surges when it is connected through the UPS coaxial connectors as shown in the drawing below pA f Surge Protection These outlets provide full time protection from surges even if the Back UPS ES is switched OFF Plug your printer fax machine scanner or other peripherals that do not need battery power into these outlets Power On and Install Software Press the ON OFF switch to power the unit ON A single short beep and the green Powe
6. he Back UPS ES is On Battery The Back UPS ES is operating normally and using battery power Once On Battery UPS ES beeps four times every 30 seconds you may want to save your current work power down your equipment and turn the unit OFF Once normal power is restored you may turn the unit back ON and power your equipment Building Wiring Fault indicator is lit Your building wiring presents a shock hazard Using the Call a qualified electrician for service Back UPS with this condition will void the warranty No phone fax DSL cable or network signal Data line from the ISP or wall outlet is connected to the Make sure the data line from the wall outlet is connected to the jack labeled Wall from the Back UPS wrong jack on the Back UPS Outlet or Cable In Cable DSS CATV Specifications Order Replacement Battery Replace with an APC qualified battery Replacement batteries can be ordered from www apc com valid credit card required The replacement battery part number for Input Voltage 120 Vrms nominal this Back UPS is RBC17 Frequency 50 60 Hz auto sensing Brownout Transfer 88 Vrms typical Warranty Over voltage Transfer 139 Vrms typical The standard warranty is 3 years from the date of purchase APC s standard Output UPS Capacity 4 outlets 650 VA 390 W procedure is to replace the original unit with a factory reconditioned unit Customers i who must have the original unit back
7. r On indicator confirms the Back UPS ES is on and ready to provide protection The Back UPS ES should charge for at least 16 hours to ensure sufficient runtime The unit is being charged whenever it is connected to utility power whether the unit is turned ON or OFF If the red Building Wiring Fault indicator located on the end near the power cord is lit your building wiring presents a shock hazard that should be corrected by a qualified electrician Install the PowerChute Personal Edition software Place the PowerChute Personal Edition CD ROM into your computer and follow the installation instructions on the screen 990 4995 Copyright 2007 American Power Conversion Corp Data Port Cable input from Internet Service Provider ISP CATV or DSS Cable output to Cable Modem CATV converter or DSS input Camie 1n Build Wirin A CAUTION teter to stn of urit tor safety markings Circuit Breaker Push to Reset ing g Fault From Wall Outlet Dataline output DSL to Modem Fax or Network 10 100BASE T Building Wiring Fault Indicator Circuit Breaker Push to Reset Status Indicators The Back UPS ES indicates operating status using a combination of visual and audible indicators Use the following table to identify the status of the Back UPS ES Status Visual Indications Power On Green Replace Battery Red Audible Indication Al
8. support apc com conditions is device may not cause harmfu interference and 2 This device must accept any http www apc com support interference received including interference that may esupport apcc com cause undesired operation Web Site www apc com On the bottom of this equipment is a label that contains USA Canada 1 800 800 4272 among other information the registration number iaa and ringer equivalence number REN for this equipment Mexico 52 292 0253 52 292 0255 If requested this information must be provided to the Brazil 0800 12 72 1 telephone company Worldwide 1 401 789 5735
9. the number of discharge cycles and serial number on bottom of unit and environmental temperature 4 Be prepared to troubleshoot the problem over the telephone with a Technical Physical Net Weight 14 3 Ib 6 5 Kg Support Representative If this is not successful the representative will issue a Return Size 3 54 H x 12 6 W x 6 97 D Material Authorization Number RMA and a shipping address 9 0 x 32 0 x 17 7 cm 5 Pack the unit in its original packaging If the original packaging is not available ask Operating Temperature 32 F to 104 F 0 C to 40 C APC Technical Support about obtaining a new set Pack the unit properly to avoid damage in transit Never use foam beads for packaging Damage sustained in transit is Storage Temperature 5 F to 113 F 15 C to 45 C not covered under warranty insuring the package for full value is recommended Operating Relative Humidity 0 to 95 non condensing 6 Write the RMA on the outside of the package Operating Elevation 0 to 10 000 ft 0 to 3 000m 7 Return the unit by insured carrier to the address given to you by APC Technical Safety and Safety Approvals TUV C US certified UL 1778 standard per CSA Support Regulatory standard C22 2 No 107 1 FCC part 68 amp FCC part 15 Class B NOM certified APC Contact Information EMC Compliance Notice This device complies with part 68 and part 15 of the ae o 0 ertor is subject to the alpn wo Online Technical Support http
Download Pdf Manuals
Related Search
Related Contents
Fiche technique AbsySplicer-AV6472 Manuel d`utilisation - Amazon Web Services User manual - Spicy Guitar Samsung S23B550V Manual de utilizare PDFダウンロード Aston SDR976-TR-CH-48-10-M Instructions / Assembly Black & Decker 7204 User's Manual Copyright © All rights reserved.
Failed to retrieve file