1. Provides important information on the current topic that must not be overlooked 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 5 SAS Expander Card CK12803 ver BO User s Manual Getting Start with SAS Serial Attached SCSI Expander Card Thanks for purchasing CHENBRO SAS Expander Card This section covers unpacking and identifying components Unpacking and Checking the Contents The complete package includes the following items Item Description Quantity Picture SAS Expander Card ver BO Mini SAS Cable 350mm Technical Specifications Internal Input from SAS RAID Card 4 port 1x Mini SAS Internal Output to Backplane 16 port 4x Mini SAS Mini SAS Ports External Input from Host 4 port 1x Mini SAS External Output to Storage Center 4 port 1x Mini SAS Number of Supported SAS SATA in directly 16 HDDs Internal connection connection of HDD Refer to Page 11 4 Pin Connector 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 6 SAS Expander Card CK12803 ver BO User s Manual CHENBRO WH Introduction About this Guide The SAS expander card user s manual provides the information for functions capabilities configuring and maintaining RAID arrays hosted by the expander card Int
2. AS backplane provides most benefits to users using the same backplane to support various SAS SATA RAID card via different conversion cables Chenbro provides various cables for different interfaces which include the followings A SFF 8087 to SFF 3D87 B SFF 8088 to SFF 8088 P N Host RAID Card Side Backplane Side Mini SAS Mini SAS 26H113215 027 SFF 8087 36pin SFF 8087 36pin Mini SAS ini 26H113215 028 SFF 8087 36pin i Mini SAS ini 26H113215 029 SFF 8087 36pin i Mini SAS ini 26H113215 030 SFF 8087 36pin Mini SAS ini 26H113325 003 SFF 8088 36pin i Mini SAS 450 mm 500 mm SATA 7Pin x4 26H113215 009 SFF 8087 36pin 650 mm 750 mm 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 12 SAS Expander Card CK12803 ver BO User s Manual Chassis Assembly Example See below for the example of how the wiring to be performed Example for Host Application RM31616 klo VERTEE 0 Be ee Slim FDD adaptor board Slim ODD adaptor board LED Board SAS RAID Card External output to JBOD or other device SAS Expander Card Mini SAS cable SFF 8087 to SFF 8087 Mini SAS cable SFF 8088 to SFF 8088 Fan Signal cable BP to LED board Slim ODD power cable Slim FDD power cable 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email i
3. S OPV nenne nee re 4 Safety Information 220222200222sssnsnsnnnsnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnssnnnnsnnnnnssnnnnsnennssnennsnnnn 5 Conventions Used in this Manual oorrsrrrnonnrrrnonnrrnronnrrrnonnrrrrrnnrrrnennvrnnnnnrrnnnnnvrennnnvnnnennvnnnnnnnne 5 Getting Start with SAS Serial Attached SCSI Expander Card ee 6 Unpacking and Checking the Contents srrrrrrrnrrrrrnnonnrnnnnnnnrrnrrennnrnnrrnnnnrnnrrnnnrnnsnennnrnennnnn 6 Technical SPECHICAUONS nee ne 6 MON NN 7 APDOU DE GU 7 Introducing the SAS Expander Card sanesneneawewanen aane ne nana nenen n anana nane nne nenen e nenen e ae 7 FANS er Dent 8 C1211 2 EEE ee 8 OSPE U OE 8 PROTO CQO de 8 SAS Expander Card Hardware rrrrnrrnnnnrrnonnrrnonvrrrnnvrennnvrrnnnvrrrnnvrrnnnvnrnnnvrrnsnvrnsnnvrnennverennvensnnrsnsnnne 9 SAS Expander Card LAN OE 9 HDD Failure LED Signal Connector rasrrrnnvrnnnnrnnnnvrrnnnvrrnnnvrrnnnvrrnnnvrrnnnvrnnnnvrnsnnressnnvenennnenn 10 Firmware Setting Jumper srrrrnrnrrrrnnnnrrrnnnnrrrnonvrrrnannrrrnnnnvrrnnnnvrnnnnnvnnnnnnvnnnnnnvnssnnnvnssennvnssnnnnne 10 Mechanical Dimension srrrrrrnnrrrrnnnnnrrrrnnnnnrrrrnnnnrrnrnnnnnvrnnnnnnvnnnnnnnnvnnsnnnnnvnnrsnnnnrnsnsnnnsnssnnnnnee 11 VISAST nenne ee ee 12 Chassis Assembly EEG 13 Example for Host Application RM31616 rrrrrrrrnnrrrrnnnrrnnnnnrrrrnnnnrrrrrnnrrrrrnnvrrrennnnrnen
4. SAS Expander Card CK12803 ver BO User s Manual CHENBRO WH CHENBRO CK12803 28 port SAS Expander Card User s Manual Version BO September 01 2009 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 1 SAS Expander Card CK12803 ver BO User s Manual CHENBRO WH Copyright Copyright 2008 CHENBRO Micom Co Ltd All rights reserved Unless otherwise indicated all materials in this manual are copyrighted by CHENBRO Micom Co Ltd All rights reserved No part of this manual either text or image may be used for any purpose other than internal use within purchasing company Therefore reproduction modification in any form or by any means electronic mechanical or otherwise for reasons other than internal use is strictly prohibited without prior written permission CHENBRO Micom Co Ltd reserves the right to make improvement and modification to the products indicated in this manual at any time Specifications are therefore subject to change without prior notice Information provided in this manual is intended to be accurate and reliable However CHENBRO Micom Co Lid assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use Trademark All registered and unregistered trademarks and company names contained in this manual are property
5. application of 28 port SAS Expander Card e Support HDD Failure Activity Indication and HDD ID Mapping e Compatible with PCI Express 4X 8X 16X amp PCI slots on motherboard High Speed I O e 1 5 Gbit s or 3 0 Gbit s operations e Automatic negotiation of linking speed Application e SAS SATA HDD NAS storage sever or enclosure e Security system e Video streaming editing workstation SAS expander card must be used only with SAS RAID card such as LSI Logic MegaRAID SAS 8888ELP 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 8 SAS Expander Card CK12803 ver BO User s Manual SAS Expander Card Hardware SAS Expander Card Layout 13 14 15 3 4 16 CHENBRO WH Hula Wer il LS E asina L mutani CE1 Mini ol TET SFF 8088 Connector External man ooo Fom hasi External Input Mini SAS SFF 8088 Connector Mini SAS SFF 8087 Connector sje Internal Input Internal input from SAS RAID card ala DC in 4 Pin Connector DC in 4 Pin Connector 4 Pin Connector From power supplier power From power supplier Mini SAS SFF 8087 Connectors sco CD1 CD4 Internal Output Output to SAS SATA II HDDs 6 CN04 Individual HDD Fault LED Connectors Indicates HDD faults refer to EEE 10 Ka CN05 Function Reserved sa function selection gjen ed refer to page 10 Green LED blinking indicates SAS 9 LED10 SAS Expander Status LED Ex
6. nfo chenbro com tw 13 SAS Expander Card CK12803 ver BO User s Manual Example for JBOD Application SAS RAID Card External Output to Another JBOD LED Board Mini SAS cable SFF 8087 to SATA Mini SAS cable SFF 8088 to SFF 8088 Chassis power On Off amp PSU alarm mute switch cable Fan Signal cable BP to LED board 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 14 SAS Expander Card CK12803 ver BO User s Manual CHENBRO WH Compatible SAS RAID Cards CK12803 Firmware Version AA11 Hardware Version BO spe MER ag Verified Verified RAID Manufacture Model Number per SAS RAID Maximum Card Firmware Card Physical Drives Version intel SRCSASRB er 1 40 32 0580 adaptec ae FH9X moder en oak Potet roseta O o oe aan The maximum quantity of supported physical drives per SAS RAID Card is depended on the capability of the SAS RAID card in the system Refer to the technical document or user guide provided by RAID card manufacturer 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 15
7. nnne 13 Example for JBOD Application aweseanewanaeenanen wanen nane nn anan ane nane nne n nane nenen e nane 14 Compatible SAS RAID CalQSs n n nenne 15 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 3 SAS Expander Card CK12803 ver BO User s Manual Revision History Aug 01 2009 e First Release e Update LED Indicating Information Page 9 Sep 01 2009 e Add Mini SAS Input Port Usage Page 10 e Update SAS RAID Card Compatibility List Page 15 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 4 SAS Expander Card CK12803 ver BO User s Manual CHENBRO WH Safety Information e Read the installation instructions before connecting to the power source e Only trained and qualified personnel should be allowed to install replace or service this equipment e Never install this product in a wet environment e Position system cables and power cables carefully route system cable and the power cable and plug so that they cannot be stepped on or tripped over Be sure that nothing rests on your system component cables or power cable Conventions Used in this Manual The following conventions are used in this manual Note Icon Provides more information on the current topic Important Icon
8. of their respective owners including but not limited to the following intel is trademark of intel Corporation LSI is trademark of LSI Corporation Adaptec is trademark of Adaptec Inc 3Ware is trademark of AMCC Corporation Areca is trademark of Areca Technology Corporation Technical Support CHENBRO works hard to offer our customers maximum performance from our chassis But in case you have any problem with our product you can find supports from the following resources Web Support Detail information of our products is in our website You can find technical updates installation guides FAQs technical specifications and more Our web address is www chenbro com Email Support You can also fill out the technical support form at our Technical Support page You technical issue inquiries will be sent directly to our support professionals Phone Support You can also contact CHENBRO HQ or branch office for immediate support their contact Information is as following CHENBRO HQ CHENBRO Europe B V CHENBRO Micom USA Inc Tel 886 2 8226 5500 Tel 31 40 295 2045 Tel 1 909 947 3200 Fax 886 2 8226 5423 Fax 31 40 295 2044 Fax 1 909 947 4300 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 2 SAS Expander Card CK12803 ver BO User s Manual Contents CI GN 2 NNK nee ren ee ge 2 TECHNICAL SUDDON un ee 2 GOMES ee ee 3 Revision H
9. pander works ready Green LED blinking indicates internal LDO1 Internal Input Status LED input link activity Red LED indicates no signal connection LDO3 External Output Status LED output link activity Red LED indicates no signal connection Green LED blinking indicates external ir meme a no signal connection va fue Function mesen 9 1a eno Firmware FM Upgrade Connector Upgrade FW to tatest version 15 ewe Functonneserved 16 sc1esco Funcionfeseves 1 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 9 SAS Expander Card CK12803 ver BO User s Manual Mini SAS Cable Connector Type ee SFF 8087 TR SFF 8088 l Only ONE input port can be connected in one CK12803 and it will not work when e connecting both external input port CE1 amp internal input port CB1 The internal input Mini SAS connector CB1 is only available to connect with SAS RAID card controller It will not work when connecting other SAS expander products CK12803 version BO supports the internal SAS Sideband signal SFF 8485 SGPIO Interface Connecting SAS RAID card and backplane with standard Mini SAS cable with side band the HDD failure LEDs on backplane will be lit and indicate the corresponding HDD has failed or is in the Unconfigured Bad state In this configuration use one CK12803 connects up to 16 HDDs directly Side bands of both ty
10. pes of SAS connectors support the SGPIO interface HDD Failure LED Signal Connector CK12803 provides two modes to indicate HDD failure LED Connector CNO4 is the cable direct attach configuration Direct attach is defined as a maximum of one HDD connected directly to each port Indicates HDD faults for Mini SAS connector CD2 Indicates HDD faults for Mini SAS connector CD4 HDD Sequence gt 01 CD6 Fault LED Indicates HDD faults for Mini SAS connector CD3 Indicates HDD faults for Mini SAS connector CD1 There is one LED per port pin When lit each backplane LED indicates the corresponding HDD has failed or is in the Unconfigured Bad state Refer to the SAS RAID cards user s manual for more information about drive states Firmware Setting Jumper e Jumper set on pin 1 amp 2 Enable the upgraded firmware version Default setting e Jumper set on pin 2 amp 3 Enable the original firmware version 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 10 SAS Expander Card CK12803 ver BO User s Manual Mechanical Dimension DORKODOCDOOOGE HDodoooooodot Saar ann uw o00 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 11 SAS Expander Card CK12803 ver BO User s Manual CHENBRO WH Mini SAS Cables The Mini S
11. roducing the SAS Expander Card SAS expander card expands one SAS address to a number of additional ports It is an optimal device for usage in data centers Distinct point to point connections SAS Host JJ 16x SASI SATA HDDs SAS HBA RAID Card er Storage Center je 16x SASI Output to SATA HDDs Device The CHENBRO 28 port SAS expander card provides high performance high disk drive connectivity scalability and flexibility in various storage environments It is a valuable solution to other expansive and complex topologies The SAS expander is ideal for high availability scalable server clustering environments front end storage subsystems used in clusters SANs and NAS environments The CHENBRO SAS Expander is based on LSI SASX28 IC that enables the connection of multiple drive devices in directly attached SAS or SATA Each expander PHY performs SAS and SATA transfer rate at 3 0 Gbit s or 1 5 Gbit s with individual configurations The SAS expander IC supports the Serial SCSI Protocol SSP SATA Tunneled Protocol STP and Serial Management Protocol SMP Those are based on SAS protocol and described in the SAS standard v1 0 and V1 1 15FI No 150 Jian Yi Road Chung Ho City Taipei Hsien Taiwan R O C Tel 886 2 82265500 Fax 886 2 82265392 Email info chenbro com tw 7 SAS Expander Card CK12803 ver BO User s Manual CHENBRO WH Features General e Flexible