Home

Panasonic EW3152W blood pressure unit

image

Contents

1. 20 Press tre mR memory recall button for the person whose data you want to recall The average of all measured values in memory will be shown CIJ mark will be shown at the bottom of the display e For example if 90 measured values are stored the average of the 90 measurements will be shown If only 1 measurement is stored the mark will not be shown e The blood pressure indicator lamps will light for approximately 6 seconds Press the WR memory recall button again Each time you press the M R memory recall button the previously stored measurement values will be SHOWN in order starting with the newest data The blood pressure indicator lamps will light for approximately 6 seconds If no measurement values are stored no value will be shown Press the M R memory recall button lightly for only a short time If you hold the button pressed for approximately 3 seconds or longer all data in memory will be erased so please be careful To cancel measurement value recall press the On Off Start button e If you forget to switch it off the blood pressure monitor will switch off automatically after approximately 30 seconds AFTER USE SPECIFICATIONS If the main body is set at an angle return it to normal Fold the display up against the main body for storage e Fold it up until you can feel a click with your hand Specifications Main body DC 6V 4 LR6 AA size alkaline
2. 12 Al desconectar el adaptador de CA no tire del cable Agarre siempre el cuerpo del adaptador de CA y descon ctelo No hacer esto podr a causar riesgo de descarga el ctrica cortocircuito o incendio 13 No inserte ning n objeto en el adaptador de CA ni permita que en el mismo se acumulen desperdicios Esto podr a causar riesgo de descarga el ctrica cortocircuito o incendio 14 No ara e da e modifique doble a la fuerza tire o tuerza el cable del adaptador de CA Adem s no coloque objetos pesados sobre el cable ni lo apriete con objetos No enrolle el cable alrededor del cuerpo principal ni del adaptador de CA Hacer cualquiera de esas cosas podr a causar riesgo de incendio o descarga el ctrica 15 No se pare sobre el adaptador de CA Hacer esto puede causar un accidente o lesi n 16 No use un convertidor de voltaje Hacer esto puede causar un incendio o descarga el ctrica 17 Este adaptador de CA est dise ado para ser utilizado solamente con monitores de presi n sangu nea de Panasonic modelo EW3152 El uso con otros aparatos el ctricos podr a causar la muerte o lesiones graves 18 SIEMPRE desconecte el adaptador de CA de la toma de corriente antes de ejecutar mantenimiento 19 No permita que este producto sea usado por ni os 20 No permita que este producto sea usado por personas que no pueden expresar sus sentimientos o que no pueden manipular el producto ellos solos Ese tipo de uso podr a causar un accidente o
3. C 32 F d jela en un sitio c lido unos 15 minutos antes de utilizarla De lo contrario el manguito puede no inflarse correctamente No guarde la unidad a la luz solar directa en sitios con mucha humedad o polvo Al limpiarlo desconecte el adaptador de CA de la toma de corriente alterna antes de la limpieza Adem s no conecte ni desconecte el adaptador de CA con las manos h medas Hacer esto puede causar una descarga el ctrica o un incendio 7 No derrame agua sobre el cuerpo principal ni sobre el adaptador de CA Hacer esto puede causar una descarga el ctrica un cortocircuito o da o al producto 8 Nouse el adaptador de CA si el mismo est da ado o si queda flojo en la toma de corriente alterna Hacer esto puede causar una descarga el ctrica o un cortocircuito 9 Siel producto no funciona correctamente o se comporta de forma extra a deje de usarlo y desconecte inmediatamente el adaptador de CA y solicite inspecci n y mantenimiento No hacer esto podr a causar riesgo de accidente descarga el ctrica o incendio 10 Alusar el adaptador de CA aseg rese de que est introducido completamente en la toma de corriente alterna No hacer esto podr a causar una descarga el ctrica o un cortocircuito 11 Cuando el producto no est us ndose desconecte el adaptador de CA de la toma de corriente alterna No hacer esto podr a causar deterioro del aislamiento debido a polvo o humedad causando un incendio el ctrico debido a fuga
4. If this is not possible however try to take measurements at a specified time prior to breakfast and before you have become active You should relax for about 5 minutes before taking the measurement e The following situations may cause substantial variations in blood pressure readings and should therefore be avoided at least 30 minutes prior to taking your blood pressure Blood pressure will be higher than usual when you are excited or tense when you are taking a bath during exercising or soon after exercising when it is cold within one hour after eating after drinking coffee tea or other beverages containing caffeine after smoking tobacco when your bladder is full Blood pressure will be lower than usual after taking a bath after drinking alcohol 6 Measurements may be impaired if this unit is used near a television microwave oven X ray equipment or other devices with strong electrical fields To prevent such interference use the unit at a sufficient distance from such devices or turn the devices off 7 This unit is designed for use by adults Consult with your physician before using this unit on a child Do not use on infants or toddlers 8 This unit is not suitable for continuous monitoring during medical emergencies or operations 9 Do not use the unit for any purpose other than measuring blood pressure Do not use the unit together with other devices 10 Improper handling of batteries may result in ba
5. Please sit upright during use Place the main unit on a table or similar object so that the main unit is at the same height as your heart Differences in height will cause differences in blood pressure values If the heights of the chair and table are not suitable you may have to lean forward In this case form a stable stack of books or similar objects under the main unit to adjust the height of the main unit Sit next to the table as shown in the figure at left Slide your AFM through the measuring section Pull the main unit close to you so that you do not have to lean to reach it e Remove your shirt or roll up your sleeve so that the measuring section will be on your bare skin e If rolling up your sleeve causes pressure on your arm or underarm remove your shirt for measurements Be sure that the rolled up sleeve does not get inside the measuring section when taking measurements Place your elbow in the support e If it is difficult to find the elbow support use your other hand to locate it Stretch out your arm and sit straight e The unit will naturally pivot upwards up to 15 as you place your hand on the table in a relaxed position 13 CAUTIONS DURING MEASUREMENTS In the following situations accurate measurements cannot be taken OWithin 1 hour of eating or drinking alcohol Olmmediately after drinking coffee or tea or smoking Olmmediately after exercising or taking a bath Wait at
6. AC outlet loosely Doing so may result in electric shock or short circuiting 9 Ifthe product does not operate properly or seems strange stop use and unplug the AC adapter immediately and request inspection and service Failure to do so could result in the risk of an accident electric shock or fire 10 When using the AC adapter make sure it is fully inserted into the AC outlet Failure to do so could result in electric shock or short circuiting 11 When the product is not in use unplug the AC adapter from the AC outlet Failure to do so could result in deterioration of the insulation due to dust or moisture causing a leakage electricity fire 12 When unplugging the AC adapter do not pull on the cord Always grasp the AC adapter body and unplug it Failure to do so could result in the risk of electric shock short circuiting or fire 13 Do not insert any object in the AC adapter or allow debris to collect on it Doing so could result in the risk of electric shock short circuiting or fire 14 Do not scratch damage modify forcibly bend pull or twist the AC adapter cord In addition do not place heavy objects on top of the cord or pinch it with objects Do not wrap the cord around the main body and the AC adapter Doing any of these things may result in the risk of fire or electric shock 15 Do not step on the AC adapter Doing so may cause an accident or injury 16 Do not use a voltage converter Doing so may cause fire or el
7. mmHg If your systolic pressure falls in one category but your diastolic pressure in another your level is classified in the higher of the two categories JNC 7 The Seventh Report of the Joint National Committee on Prevention Detection Evaluation and Treatment of High Blood Pressure National Institute of Health NIH Publication No 03 5233 May 2003 IMPORTANT e Do not be alarmed by temporarily high or low readings because fluctuations in a person s blood pressure are not uncommon If possible measure and record your blood pressure at the same time every day and consult your physician if you have questions or concerns e f abnormal variations in blood pressure are observed in measurement please consult your physician PARTS IDENTIFICATION Please check the instrument Pressure cuff Battery cover containing battery holder Connector Back side of main body y Quick air release button pr am Push and hold Start m i Start Elbow support Blood pressure SYS 1400 indicator lamp mmHg 0 Display DIA oo mmHg E Pulse Imin Memory Recall Date Time buttons 1 and 2 1 Set button 2 Adjust button Included accessory AC adapter WHEN USING THE AC ADAPTER Use only the exclusive AC adapter included accessory See p 9 Ei ste Insert theac adapter plug into the connector on the side of the main unit Plug the AC adapter full
8. ngulo cambia durante las mediciones 41 HACER UNA LECTURA continuaci n Medici n Pulse el bot n encender parar A El manguito de presi n se apretar autom ticamente ou on Q La presurizaci n se ejecutar autom ticamente y se r Ou oo ou oo na co oo oo DIO Ui E Toda la pantalla se tomar n las mediciones ca 7 Lut m ny co vaa Y vg LE DHAR El manguito de El indicador con forma iluminar durante 1 presi n se de coraz n ef parpadear segundo apretar cuando se detecte el pulso aproximadamente autom ticamente durante el proceso de presurizaci n Cuando se haya completado la medici n Se B i E38 visualizar n los valores de la L4 presi n sangu nea y del pulso a 7 A OS 1 ha Despu s de que los valores de medici n hayan sido mostrados p durante aproximadamente 5 segundos el manguito de presi n se Te LL l so aflojar Sin embargo el tiempo depende del tama o del brazo b sou e Los indicadores de la presi n arterial se encender n durante unos 12 mm ae Pit segundos MZ e Si el valor obtenido se encuentra dentro de la regi n considerada de O O presi n arterial alta el n mero parpadear durante unos 12 segundos Para saber c mo leer los indicadores de la presi n arterial consulte la p g 43 Se encender n los indicadores CD C2 Para saber c mo almacenar los resultados de las med
9. su estado mental del ejercicio realizado etc M s particularmente existe el fen meno de la hipertensi n de bata blanca cuando se toma la presi n en la consulta de un m dico la presi n arterial es mayor en la consulta debido a la preocupaci n o el nerviosismo del paciente Asimismo si los valores de presi n arterial obtenidos en casa son unas veces m s altos y otras m s bajos que los obtenidos en la consulta de su m dico tenga en cuenta lo siguiente Tenga en cuenta estos detalles cuando se tome la presi n Postura incorrecta durante la medici n Tom las mediciones con su cuerpo inclinado en ngulo hacia adelante Q Las mediciones no se tomaron en la parte superior del brazo Tome las mediciones con su codo en el soporte para codo del cuerpo principal Consulte la p g 39 Estaba preocupado o irritado durante las mediciones Antes de tomar las mediciones respire profundamente 2 3 veces y rel jese para as estabilizar la presi n sangu nea Asimismo le recomendamos que se siente tranquilamente durante unos 5 minutos antes de tomarse la presi n 49 Por qu difieren los resultados cada vez que me tomo la presi n La presi n arterial cambia incluso dentro de un mismo d a y difiere seg n la postura adoptada en el momento de realizar la medici n Debido a esto es muy importante que cuando se tome la presi n lo haga siempre bajo las mismas condiciones La presi n de la
10. 33 de mayo de 2003 IMPORTANTE e No se alarme en caso de lecturas temporarias elevadas o bajas porque las fluctuaciones de la presi n sangu nea de las personas no son poco frecuentes De ser posible mida y registre la presi n todos los d as a la misma hora y consulte al m dico en caso de dudas o inquietudes e Si se observan variaciones anormales en la medici n de la presi n consulte con el m dico 33 IDENTIFICACI N DE LOS COMPONENTES Compruebe el instrumento y sus partes Manguito de presi n 2 Open gt display panel Bot n de apertura de la pantalla Parte de debajo d Tapa del 2 compartimiento CD e de las pilas RT conteniendo el CCA compartimiento de _ las pilas Conector 34 Parte posterior del Bot n de cuerpo principal ZA liberaci n r pida O del aire pulse y mantenga pulsado Bot n encender parar Soporte para codo r Indicadores de SYS 1400 la presi n arterial mmHg 120 Pantalla DIA a00 mmHg 20 Pulse Imin Bot n Hora Fecha memoria 1 Bot n ajustar 1 recuperar 1 y 2 2 Bot n ajustar 2 Accesorio incluido Adaptador de CA 35 UTILIZACI N DEL ADAPTADOR DE CA Utilice solamente el adaptador de CA exclusivo accesorio incluido Consulte la p g 35 Introduzca a clavija del adaptador de CA en el conector situado en un lateral del dispos
11. Caution when using only the AC adapter on p 10 Press the set button 8 3 520 Set the hour below the display CD Press the Set button The The month value will blink hour value will blink Press the Adjust button to set the correct hour 073 500 Set the minute 3 5 00 FP EoD Set the month UNI CD Press the Set button The Press the Adjust button minute value will blink repeatedly to set the Press the Adjust button correct month repeatedly to set the correct o minute Press the Set button at B 3 538 i i itm Set the day 30 the ACON in Press the Set button The changes 19 na ize day value will blink e daterdme Sening 2 Press the Adjust button Press the On Off Start Me dene button to switch off y the power When the date or time are blinking the clock is stopped During leap years 3 1 will be displayed on February 29 For this reason reset the date to 2 29 Use the tip of a ballpoint pen or similar object to lightly press the Set and Adjust buttons If you use a mechanical pencil the lead may break causing a malfunction 12 Getting into the measurement position Either the left or right arm can be measured However when measurements are taken using the right arm it may be difficult to see the display Since there may be blood pressure differences of around 10mmHg between the left and right arm be sure to use the same arm for all measurements The product cannot be used while lying down
12. Panasonic Upper Arm Blood Pressure Monitor Monitor de presi n arterial de brazo Operating Instructions Instrucciones de funcionamiento Model No EW3152 Modelo No EW3152 Before operating this device please read these instructions completely and save this manual for future use Antes de utilizar este dispositivo lea completamente estas instrucciones y conserve este manual para futura referencia Table of Contents Introduction Basics of Blood Pressure Important Instructions Before Use Precautions to Ensure Safe Reliable Operation Easily Check Your Blood Pressure Readings Against the JNC 7 Classification Parts Identification When using the AC adapter When using batteries Before starting measurements Cautions during measurements Taking a reading Alarm function signals high blood pressure Storing measurement values Recalling stored measurement values After use Specifications Cautions during measurements Q amp A Care and Maintenance Troubleshooting oN O A CO CO 10 12 14 14 17 19 20 21 22 23 25 26 Introduction Thank you for purchasing the Panasonic Upper Arm Blood Pressure Monitor EW3152 Measuring your own blood pressure is an important way of monitoring your health High blood pressure hypertension is a major health problem which can be treated effectively once detected Measuring your blood pressure between doctor visits on a regular basis in the comfort of your home and keepin
13. UREMENT VALUES This product can separately store 90 measurements each for two persons N After measurement the CD E will light Press the M R memory recall button with the number corresponding to the person for which measurements should be stored Example Person A Press D Person B Press 2 Storing is completed e Up to 90 measurement values can be stored When the memory is full and additional values are stored the oldest value in memory will be deleted and the new value will be stored e If measurements could not be taken properly the E mark is shown instead of the blood pressure value measurement values cannot be Number stored of stored However if the E mark is displayed for only the data pulse value data can be stored To erase all measured values stored in memory 1 Recall the measurement value for the person whose data you want to delete by pressing that person s M R memory recall button 2 Press the same M R memory recall button again and hold it pressed until the measurement values disappear approximately 3 seconds or more t is not possible to erase single measurement values To switch off the blood pressure monitor 9wott press the On Off Start button Start e f you forget to switch it off the blood pressure monitor will switch off automatically after approximately 5 minutes 19 RECALLING STORED MEASUREMENT VALUES
14. according to the proper procedure and in the correct posture displayed B 3 15 30 Pressure decreased suddenly and the remeasure Apre P mark E appeared gt gt The heart mark f blinked only a few times or gt Be sure your arm is properly not at all inserted into the main unit See p 13 If problem continues Symptom You moved or talked during measurements a i MEN odis Your arm was not inserted properly into the main unit po See p 13and 14 een D gt Blood pressure varies in response to minute changes in your mental ee state such as your reaction to a doctor s presence Measurement values are different gt e Relax for 4 to 5 minutes and take another measurement gt with each measurement See p 14 and 17 gt Batteries are installed with the polarities wrong No display appears even when the See p 11 gt On Off Start button is pressed o E gt 5 o E 2 LJ o g o o o D o gt x o lt If problem continues When the On Off Start button is Batteries are exhausted pressed the display disappears during D gt pressurization 7x mark apears Since measurements are taken during pressurization operating sound may be heard and pressurization rate may change during pressurization This is normal and is not a malfunction During pressurization the sound or pressurization rate changes Press the ring portion on the outsid
15. ar n vos resultados de mediciones previamente almacenados por orden empezando por los datos m s recientes Los indicadores de la presi n arterial se encender n durante unos 6 segundos e Sino se ha almacenado ning n resultado no se mostrar nada Pulse breve y ligeramente el bot n M R memoria recuperar Si mantiene pulsado el bot n durante unos 3 o m s segundos se borrar n todos los datos de la memoria por lo que le recomendamos que vaya con cuidado 3 Para cancelar el proceso de recuperaci n de un resultado pulse el bot n encender parar Sise olvida de apagarlo el monitor de presi n arterial se apagar autom ticamente transcurridos aproximadamente 30 segundos 46 DESPU S DEL USO ESPECIFICACIONES Si el cuerpo principal est colocado en ngulo regr selo a la posici n normal Pliegue la pantalla hacia el cuerpo principal para guardarla e Pli guela con la mano hasta que sienta un chasquido Especificaciones Cuerpo principal Alimentaci n el ctrica CC de 6V 4 pilas alcalinas tama o AA LR6 CA de 100 240V 50 60Hz Cuando se usa adaptador de CA Pantalla Digital LCD M todo de medici n Sistema oscilom trico Limites de medici n Presi n arterial de O a 280 mmHg Frecuencia de pulso de 30 a 160 latidos por minuto Presi n arterial 3mmHg Margen de error 9 Frecuencia de pulso 5 Niveles de humedad temperatura de funcionamien
16. ara el valor del pulso los datos podr n almacenarse Para borrar todos los resultados de mediciones almacenados en la memoria 1 Recupere el valor de medici n para la persona cuyos datos desea borrar pulsando el bot n M R memoria recuperar de esa persona 2 Vuelva a pulsar el mismo bot n M R memoria recordad y mant ngalo pulsado hasta que desaparezcan los resultados de la pantalla aproximadamente 3 o m s segundos No es posible borrar resultados de mediciones de manera individual onion Para apagar el monitor de presi n arterial pulse el n bot n encender parar Start T e Si se olvida de apagarlo el dispositivo se apagar autom ticamente transcurridos aproximadamente 5 minutos 45 RECUPERAR RESULTADOS DE MEDICIONES ALMACENADOS M R Pulse el bot n wR memoria recuperar CD CO correspondiente a la persona cuyos datos desee 19 2O recuperar 1 2 Se mostrar el promedio de todos los resultados almacenados en la memoria e Aparecer el indicador WEB en la parte inferior de la pantalla e Por ejemplo si se han almacenado 90 resultados se mostrar el promedio de las 90 mediciones Si s lo hay almacenado el resultado de una medici n no aparecer el indicador EXB Los indicadores de la presi n arterial se encender n durante unos 6 segundos Vuelva a pulsar el bot n M R memoria recuperar Cada vez que pulse el bot n memoria recuperar se mostr
17. ay In addition it can change greatly depending on the weather your mental state exercise etc In particular there is the phenomenon of White uniform hypertension at doctor s offices where the blood pressure measured in a doctor s office is higher because of stress or worry In addition if the blood pressure measured at home is sometimes higher and sometimes lower than the blood pressure measured at the doctor s office the following can be considered Please pay attention to these points when taking measurements Measuring posture was poor Did you take measurements while leaning forward with your body at an angle Measurements were not taken at the upper arm Please take measurements with your elbow in the elbow support of the main body See p 13 Were you worried or upset during measurements Before taking measurements take 2 or 3 deep breaths and relax so that your blood pressure stabilizes In addition it is recommended that you sit quietly for about 5 minutes before taking measurements 23 Why are measured blood pressure values different each time I take a measurement Blood pressure changes even within a single day and it is different depending on the measurement posture Because of this when taking measurements be sure to always take measurements under the same conditions Q For persons taking blood pressure medication blood pressure may change greatly due to the effects of the medi
18. batteries Power source AC 100 240V 50 60Hz When using AC adapter Display Digital LCD Measurement method Oscillometric system Blood pressure 0 to 280mmHg Pulse rate 30 to 160 beats per minute Blood pressure Within 3mmHg Accuracy Pulse rate Within 5 10 to 40 C 50 to 104 F 15 to 90 RH Operation temperature humidity range Storage temperature humidity range 20 to 60 C 4 to 140 F 10 to 95 RH Measurable arm CAMERE Approx 20 to 34cm 7 3 4 to 13 1 4 Weight Approx 4 9 Ibs 12008 not including batteries Dimensions 22 x 15 5 x 21cm 8 21 32 x 6 3 32 x 8 1 4 Specifications AC adapter AC 100 240V 50 60Hz Output DC 6V 2A CAUTIONS DURING MEASUREMENTS In the following situations accurate measurements cannot be taken Within 1 hour of eating or drinking alcohol D 7 So Immediately after exercising or taking a bath aw Wait at least 20 minutes and take a measurement while staying quiet In cold places Take measurements at ambient temperatures of 10 to 40 C 50 to 104 F 22 Immediately after drinking coffee or tea or smoking x EN 7 In a moving vehicle ZEN 2 When you need to urinate a V A Wait several minutes after urinating before taking measurements Q amp A Why are the blood pressure values measured at home different from those measured at the doctor s office A Blood pressure varies 24 hours a d
19. cation When taking 2 measurements in succession be sure to stay quiet for 4 to 5 minutes after the first measurement before taking the next measurement Q Why are the measured values different for the left and right arm It is said that differences in blood pressure values between the left and right arms may be around 10mmHg The blood pressure can be measured in either the left or right arm but all measurements should be taken using the same arm for comparative consistency 24 CARE AND MAINTENANCE Do not apply excessive force to the instrument or drop the instrument e Doing so may cause damage If the instrument is stored at temperatures below the freezing point do not use it immediately Leave it in a warm place for at least an hour before use e If the instrument is not allowed to warm up it may not pressurize Do not insert dust or foreign objects into the instrument e Doing so may result in damage If the instrument becomes dirty clean it with a soft cloth moistened with warm water or soapy water Do not use alcohol benzine or paint thinner Use of such chemicals may result in cracking or discoloration For storage avoid high temperatures high humidity and direct sunlight e Storage under such conditions may result in damage The pressure cuff cannot be washed 25 TROUBLESHOOTING Remeasure b Pressurization to more than 280mmHg was Were measurements taken mark E is performed
20. ce el manguito de presi n en el cuerpo principal Manguito de presi n Presione a manguito de presi n dentro de la ranura del cuerpo principal N gt Puede conectarse primero lo mismo la parte frontal que la posterior Ranura Al volver a conectar aseg rese de no tocar el interior del cuerpo principal en la parte de la que se ha salido el manguito de presi n Hacer esto puede causar un accidente o una lesi n 44 ALMACENAR LOS RESULTADOS DE LAS MEDICIONES Este producto puede almacenar por separado los resultados correspondientes a 90 mediciones correspondientes a dos personas distintas a Despu s de realizar una medici n se encendera el indicador CO Pulse el bot n M R memoria recuperar con el n mero correspondiente a la persona a la que corresponda la medici n en cuesti n Ejemplo Persona A Pulse C1 Persona B Pulse 2 e Es posible almacenar un m ximo de 90 resultados de mediciones Cuando la memoria est llena y se guardan m s resultados se borra autom ticamente el resultado m s antiguo guardado y se almacena el valor nuevo en su lugar us Ui am 7 Las EU Sila medici n no se pudo llevar a cabo El adecuadamente aparece el indicador E en vez del valor correspondiente a la presi n arterial no es Cantidad de posible almacenar los resultados datos Sin embargo si el indicador se visualiza M R 1 C 2 5 almacenados solamente p
21. do e bot n encenderipaar est pulsado Las pilas est n gastadas la visualizaci n desaparece durante la presurizaci n aparece la indicaci n 3 Consulte la p g 37 Como las mediciones se toman durante presurizaci n puede Durante la presurizaci n cambia el escucharse un sonido de operaci n y la tasa de presurizaci n puede sonido o la tasa de presurizaci n cambiar durante la presurizaci n Esto es normal y no es un mal funcionamiento Presione la parte del anillo en el exterior del manguito de presi n El manguito de presi n se separa dentro del cuerpo principal Consulte la p g 44 Lleve el dispositivo a la tienda donde lo adquiri El dispositivo est roto para que lo prueben y se encarguen de realizar las reparaciones necesarias 52 53 For questions or assistance with your blood pressure monitor call us at 1 800 338 0552 Panasonic Consumer Electronics Company Division of Panasonic Corporation of North America One Panasonic Way 1H 1 Secaucus NJ 07094 No 1 EN SP 7 373 O 2005 Matsushita Electric Works Ltd All Rights Reserved Printed in China
22. do el compartimiento de las pilas vuelve a su posici n puede escucharse Tapa del moment neamente un sonido de compartimiento operaci n de las pilas 5 Vuelva a colocar la tapa y desl cela hasta Cerrarla Cambie las pilas cuando El indicador de la izquierda aparece durante el uso del dispositivo Todos los indicadores permanecen encendidos durante un momento tras pulsar el bot n encender parar y a continuaci n la pantalla se queda en blanco e No aparece ning n indicador incluso despu s de pulsar el bot n encender parar Se pueden realizar aproximadamente 200 mediciones aproximadamente 2 meses si se toma la presi n 3 veces al d a con un paquete de pilas alcalinas Panasonic nuevas cuatro pilas LR6 de tamafio AA Condiciones de medici n temperatura ambiente 22 C 72 F presurizado a 170 mmHg circunferencia del brazo 30 cm 11 51 64 Las pilas suministradas se incluyen solamente para prop sitos de prueba Por tanto no hay garant as con respecto a la duraci n de sus vidas tiles e Incluso en el caso de que no se hubiera utilizado el producto por mucho tiempo cambie las pilas una vez al a o Si se demora m s en cambiarlas pueden producirse da os en el dispositivo por fugas del l quido que hay en el interior de las pilas Cuando cambie las pilas utilice siempre cuatro pilas alcalinas nuevas del mismo tipo y del mismo fabricante Silatemperatura ambiente es baja es posible que se r
23. e la presi n sangu nea es una buena forma de monitorear la salud La alta presi n sangu nea hipertensi n constituye un grave problema para la salud que se lo puede tratar con eficacia una vez que se lo detecta Medir la presi n sangu nea en el intervalo entre una visita al m dico y la siguiente en forma frecuente y desde la comodidad de su hogar y llevar un registro de las mediciones lo ayudar n a monitorear todo cambio significativo producido en la presi n Llevar un registro exacto de la presi n sangu nea le permite al m dico diagnosticar e incluso llegar a prevenir enfermedades futuras Conceptos b sicos relativos a la presi n sangu nea El coraz n funciona como una bomba que env a la sangre a trav s de las venas con cada contracci n La presi n sangu nea es la presi n que ejerce la sangre bombeada desde el coraz n contra las paredes de los vasos sangu neos La presi n sist lica es la presi n ejercida cuando el coraz n se contrae y bombea sangre a las arterias La presi n diast lica es la presi n ejercida cuando el coraz n se expande o relaja Cuando usted o el m dico toman la presi n sangu nea se miden tanto la sist lica como la diast lica Si la medici n es 120 sobre 80 120 80 por ejemplo la presi n sist lica es de 120 y la diast lica es de 80 29 Instrucciones importantes previas al uso 1 5 No ha de confundirse autocontrol con autodiagn stico Solamente un profesional familiari
24. e of the pressure cuff into the main body Pressure cuff comes of See p 18 Take it to the store where it was purchased for testing and repairs Instrumentis broken gt 26 27 ndice INtroducci Nn 29 Conceptos b sicos relativos a la presi n sangu nea eee 29 Instrucciones importantes previas al uso A 30 Precauciones para garantizar un funcionamiento seguro y fiable 32 Corrobore sin dificultad las lecturas de la presi n sangu nea seg n la clasificaci n JNC 7 Inneren 33 Identificaci n de los componentes 34 Utilizaci n del adaptador de CA 9M 36 Utilizaci n de pilas mmm 37 Antes de empezar a tomarse la presi n 38 Precauciones durante las mediciones cce 40 Hacer una lectura eee tentent nennen 40 La funci n de alarma se ala la hipertensi n sangu nea 7 43 Almacenar los resultados de las mediciones sss 45 Recuperar resultados de mediciones almacenados 511111 46 Despu s del uso especificaciones nao neo ocio eno a o cono eno nen nten 47 Precauciones durante las mediciones M 48 Preguntas y respuestas mme nne SADA oo nnne nennen 49 Cuidado y mantenimiento mmm mem mem emen 51 Resoluci n de problemas mem eme 52 28 Introducci n Gracias por haber adquirido el monitor de presi n arterial de brazo Panasonic EW3152 Tomars
25. ectric shock 17 This AC adapter is designed for use only with Panasonic Blood Pressure Monitors model EW3152 Use with other electrical devices may result in death or serious personal injury 18 ALWAYS unplug the AC adapter from the power outlet before performing maintenance 19 Do not let this product to be used by children 20 Do not let this product to be used by people who cannot express their feelings or who cannot operate the product by themselves Such use may result in an accident or injury 21 Use AC adapter only with electrical outlet of voltages marked on name plate For use in the U S A use AC adapter only with AC 120V electrical outlet Use with electrical outlets at other voltages may results in the risk of fire electric shock or burns 22 Do not allow any material to drape over the AC adapter Doing so could result in the risk of fire 23 Do not modify or attempt to repair the product or AC adapter by yourself Doing so could result in the risk of fire electric shock or personal injury iN gt on Easily Check Your Blood Pressure Readings Against the JNC 7 Classification Blood Pressure Categories 3 3 TI E Stage 2 Hypertension e g SBP 165 DBP 105 100 SBP 150 DBP 95 e g SBP 130 DBP 85 Stage 1 Hypertension e g 90 Prehypertension 80 Normal e g SBP 115 DBP 75 Diastolic Blood Pressure DBP 120 140 160 Systolic Blood Pressure SBP
26. eduzca la vida til de las pilas 37 ANTES DE EMPEZAR A TOMARSE LA PRESI N Abra la pantalla Pulse el bot n Open en la parte frontal de la unidad principal para abrir la pantalla La pantalla solamente se abrir parcialmente por s misma Para usarla brala completamente con su mano Ajuste de la fecha y la hora Ajuste la fecha y la hora antes de realizar la primera medici n tras adquirir el tensi metro o despu s de cambiar las pilas e Si se efect an las mediciones sin configurar la fecha ni la hora no se registran estos datos e Lea las Precauciones al utilizar solamente el adaptador de CA en la p gina 36 Pulse el bot n ajustar B8 3 0 00 Ajuste la hora 1 debajo de la pantalla O Pulse el bot n ajuste 1 El Parpadea el valor valor de la hora parpadear perteneciente al mes 2 Pulse el bot n ajuste 2 para ajustar la hora correcta Ajuste los minutos j 7 B 3 15 00 7 EBD 2 Aj uste el mes O Pulse el bot n ajuste 1 El valor Para ajustar el mes de los minutos parpadear correcto pulse A Pulse repetidamente el bot n repetidamente el bot n ajuste 2 para ajustar los y ajustar 2 minutos correctos ems Pulse el bot n ajuste 1 en el 8 3 15 20 momento exacto en que z cambien los minutos para 8 i 5 08 3 Ajuste el d a terminar el ajuste de la CD Pulse el bot n ajuste 1 El fecha y de la hora valor del d a parpadear G Pulse repe
27. el m dico antes de tomarse ellos mismos la presi n sangu nea Es posible obtener distintos valores por su estado T mese la presi n todos los d as a la misma hora y en las mismas condiciones e El momento ideal para tomar la presi n para obtener la denominada 30 presi n sangu nea base es por la ma ana justo despu s de levantarse antes de desayunar y antes de hacer actividad o ejercicio algunos De no ser posible no obstante pruebe efectuar las mediciones en un momento dado antes del desayuno y antes de entrar en actividad Debe relajarse unos 5 minutos antes de efectuar la medici n e Las siguientes situaciones pueden provocar variaciones considerables en las lecturas de la presi n sangu nea y por lo tanto se las debe evitar al menos 30 minutos antes de tomar la presi n La presi n sangu nea es mayor que lo normal en estado de excitaci n o tensi n al tomar un ba o durante el ejercicio o inmediatamente despu s cuando hace fr o en un lapso de una hora despu s de haber comido despu s de tomar caf t u otras bebidas que contengan cafe na despu s de fumar tabaco con la vejiga llena La presi n sangu nea es menor que lo normal despu s de tomar un bafio despu s de beber alcohol 6 Las mediciones pueden resultar afectadas si se utiliza esta unidad cerca del televisor horno de microondas equipo de rayos X u otros dispositivos con campos el ctricos fuertes Para evitar esa inte
28. esi n arterial alta el n mero parpadear durante unos 12 segundos S lo inmediatamente despu s de realizar la medici n Si las mediciones no se pudieron realizar adecuadamente 8 7 3 5 35 Aparecer el indicador E de repetir la medici n Cuando realice varias mediciones sucesivamente pulse una vez el bot n encender parar para apagar el monitor de presi n arterial permanezca quieto a durante 4 5 minutos y a continuaci n realice la siguiente medici n Consejo En general los valores de presi n arterial que se obtienen en la segunda medici n son inferiores dado que se est menos nervioso y m s relajado Para las personas que se ponen nerviosas con facilidad resulta muy eficaz realizar dos mediciones cada vez que quieran tomarse la presi n Cuando se realizan dos mediciones generalmente se almacena el valor m s peque o Cuando realice dos mediciones consecutivas permanezca siempre quieto durante 4 5 minutos entre la primera y la segunda medici n 43 Para interrumpir r pidamente las mediciones Si el manguito de presi n no yop se desinfla incluso cuando se pulsa el bot n encender parar pulse y mantenga pulsado el bot n de liberaci n r pida del aire El aire se liberar en aproximadamente 4 segundos Con la cinta y la costura hacia abajo deslice manguito de presi n en el cuerpo principal Cinta Con la cinta y la costura hacia abajo desli
29. g a record of the measurements will help you monitor any significant changes in your blood pressure Keeping an accurate record of your blood pressure will help your doctor diagnose and possibly prevent any health problems in the future Basic of Blood Pressure Your heart acts like a pump sending blood surging through your blood vessels each time it contracts Blood pressure is the pressure exerted by blood pumped from the heart on the walls of blood vessels Systolic pressure is the pressure exerted when the heart contracts and pumps blood into the arteries Diastolic pressure is the pressure exerted when the heart expands or relaxes When you or your doctor take your blood pressure both your systolic and diastolic pressures are measured If your blood pressure measurement is 120 over 80 120 80 for example your systolic pressure is 120 while your diastolic pressure is 80 Important Instructions Before Use 1 5 Do not confuse self monitoring with self diagnosis Blood pressure measurements should only be interpreted by a health professional who is familiar with your medical history If you are taking medication consult with your physician to determine the most appropriate time to measure your blood pressure NEVER change a prescribed medication without first consulting with your physician Blood pressure can vary based on many factors including age gender weight and physical condition In general a person s blood pressure i
30. he angle may change slightly during pressurization However there is no effect on accuracy even if the angle changes during measurements 15 TAKING A READING conrtinveo Press the on off Start button Measurement o Start rr Qu i ES Pn QNS SES Lt o NC ME c Wir I MAA The entire display will light for approximately 1 second a a s jum JERRY LI E cm Eo cil m H A 0 Pe Vo e 1 ru 8 O EA Y rt 16 D The pressure cuff wil be tightened automatically Pressurization will be performed automatically and measurements will be taken ca iw ER m ny co 3 The pressure cuff will be tightened automatically When measurement has been completed the blood pressure and pulse values will be displayed After measurement values have been shown for approximately 5 seconds the pressure cuff will be loose However the time The heart mark Y will blink when pulse is detected during pressurization depends on the size of the arm The blood pressure indicator lamps will light for approximately 12 seconds e fthe measured value is in the high blood pressure region the values will blink for approximately 12 seconds For how to read the blood pressure display see p 17 The CD C2 marks will light For storing measurement values
31. iciones consulte la p g 45 El valor correspondiente a la frecuencia de pulso equivale a los latidos por minuto calculados en base a la frecuencia de pulso durante la medici n y Retire su brazo de la unidad principal On Off E n Para apagar el monitor de presi n arterial pulse el bot n encender parar e Sise olvida de apagarlo el dispositivo se apagar autom ticamente transcurridos aproximadamente 5 minutos 42 La funci n de alarma se ala la hipertensi n sangu nea Los valores de la presi n sangu nea correspondientes a las lecturas sist lica y diast lica se determinan e indican mediante un sistema de LED de tres colores comprendido entre la escala de normal a hipertenso sobre la base de las definiciones y la clasificaci n de los niveles de presi n sangu nea de JNC 7 Asimismo cuando la presi n es elevada la lectura que aparece en pantalla destella para alertar al usuario Seg n la clasificaci n JNC 7 se considera que los valores que siempre superan los 140 mmHg sist lica y o los 90 mmHg diast lica constituyen la hipertensi n arterial ordeka Diast lica mmHg N A Hipertensi n 140 H arana etapa 1 etapa 2 120 D 90 N Amarillo Prehipertensi n 90 80 sol H m Verde 120 140 mmHg Sist lica Presi n sist lica 140 mmHg y m s Presi n diast lica 90 mmHg y m s Siel valor obtenido se encuentra dentro de la regi n considerada de pr
32. itivo 2 Enchufe i adaptador de CA en una toma de corriente alterna Al insertar el adaptador de CA en la toma puede escucharse moment neamente un sonido de operaci n PRECAUCI N Aseg rese de utilizar solamente el adaptador de CA exclusivo accesorio incluido La utilizaci n de otros adaptadores de CA podr a provocar un accidente Precauciones al utilizar solamente el adaptador de CA Si no hay pilas en el dispositivo y se desconecta el adaptador de CA de la toma de corriente o del dispositivo la fecha y la hora ajustadas se borrar n y se pondr n a cero Es por ello que a n cuando utilice el adaptador de CA le recomendamos que haya pilas en el interior del dispositivo Cuando se utiliza el adaptador de CA la energ a el ctrica proviene del adaptador por lo que no se gasta virtualmente nada de energ a de las pilas 36 UTILIZACI N DE PILAS Utilice siempre pilas alcalinas Cuatro pilas alcalinas LR6 de tama o AA Use solamente pilas alcalinas No use otros tipos de pilas D le la vuelta a la unidad apriete ligeramente en la marca A de la tapa Compartimiento del compartimiento de las pilas y de las pilas retire ta tapa desliz ndola en el sentido de la flecha Deslice hacia afuera el compartimiento de las pilas en la direcci n de la flecha Compruebe la polaridad de las pilas e inst lelas correctamente Deslice nacia adentro el compartimiento de las pilas en la direcci n de la flecha Cuan
33. least 20 minutes and take a measurement while staying quiet Oln a moving vehicle Oln cold places Take measurements at ambient temperatures of 10 C to 40 C 50 F to 104 F OWhen you need to urinate Wait several minutes after urinating before taking measurements TAKING A READING Cautions to obtain accurate measurements Sit quietly and relax while taking measurements Do not lean f Do not take forward with Wi Pp measurements at E your body atan 5 y the elbow Place NS e angle during en your elbow in the A ES measurements a E elbow support M Take NEN li measurements in the proper posture 14 Do not lift the main unit off the table Keep it on the table during measurements Do not lift your arm Rest your hand on the table Nox y with your palm upwards Do not let your rolled up sleeve be inside the measuring section Roll your sleeve far up your arm Be sure to obey the following points for accurate measurements Do not move your body arm or fingertips e Do not touch the main unit e Do not talk e Do not use a cellular phone near the main unit Not following these points may make it impossible to obtain accurate measurements The angle of this product can be adjusted so that measurements can be taken without having to be in a 15 forced posture e The angle can be adjusted only when the display is open e The angle is not locked Even if you sit still t
34. lesiones 21 Use el adaptador de CA solamente con tomas de corriente con los voltajes marcados en la chapilla del fabricante Para uso en Estados Unidos use el adaptador de CA solamente con una toma el ctrica de CA de 120V El uso con tomas el ctricas de otros voltajes puede causar riesgo de incendio descarga el ctrica o quemaduras 22 No permita que el adaptador de CA quede cubierto con ning n material Hacer esto podr a causar riesgo de incendio 23 No modifique ni intente reparar usted mismo el producto ni el adaptador de CA Hacer esto podr a causar riesgo de incendio descarga el ctrica o lesiones personales Boos NET on 32 Corrobore sin dificultad las lecturas de la presi n sangu nea seg n la clasificaci n JNC 7 Categor as de presi n sangu nea 3 3 E E Hipertensi n de estado 2 ejemplo SBP 165 DBP 105 Hipertensi n de estado 1 ejemplo SBP 150 DBP 95 Prehipertensi n ejemplo SBP 130 DBP 85 Normal ejemplo SBP 115 DBP 75 Presi n sangu nea diast lica gt DBP 120 140 160 Presi n sangu nea sist lica SBP mmHg Si la presi n sist lica queda comprendida en una categor a pero la diast lica en otra se clasifica el nivel en la m s alta de las dos categor as JNC 7 El s ptimo informe de la publicaci n conjunta del Comit nacional Sobre prevenci n detecci n evaluaci n y tratamiento de la hipertensi n arterial Instituto nacional de salud NIH N 03 52
35. ntes de tomarse la presi n HACER UNA LECTURA Precauciones para obtener mediciones precisas Si ntese tranquilo y relajado mientras realiza las mediciones No incline su f No tome las cuerpo hacia Pp mediciones en el adelante en CH y codo Coloque su ngulo durante A codo en el soporte las mediciones E E para codo Tome las NEN EZ mediciones con la z postura apropiada 40 No levante la unidad principal de la No levante su A mesa brazo V Mant ngala Descanse su A sobre la mesa mano sobre la E durante las mesa con su mediciones palma hacia arriba No permita que su manga remangada quede dentro de la secci n de medici n Remangue la manga hasta bien arriba en su brazo Para obtener mediciones precisas aseg rese de cumplir los siguientes puntos e No mueva su cuerpo brazo ni las yemas de los dedos e No toque la unidad principal e No hable e No use un tel fono m vil cerca de la unidad principal El no cumplimiento de estos aspectos puede imposibilitar la obtenci n de mediciones precisas El ngulo de este producto puede ajustarse de forma que las mediciones puedan tomarse sin tener que estar en una postura forzada e El ngulo puede ajustarse solamente cuando la pantalla est abierta e El ngulo no est bloqueado Incluso aunque est sentado el ngulo puede cambiar ligeramente durante la presurizaci n Sin embargo esto no afecta la precisi n incluso si el
36. peraturas altas alta humedad y la luz solar directa e Si se guarda bajo esas condiciones puede da arse El manguito de presi n no puede lavarse 51 RESOLUCI N DE PROBLEMAS Las mediciones se realizaron siguiendo el procedimiento correcto y con la postura corporal correcta Consulte la p gs 39 y 40 Aparece el indicador Se presuriz a m s de 280 mmHg E de repetirla medici n B 3 15 30 La presi n disminuy de repente y apareci el indicador E de repetir la medici n El indicador con forma de coraz n parpaded s lo Aseg rese de que su brazo Unas pocas veces o no lleg a hacerlo est insertado correctamente en la unidad principal Consulte la p g 39 Si el problema persiste Se movi o habl durante las mediciones Su brazo no estaba insertado correctamente en la unidad principal Consulte la p gs 39 y 40 El valor de la presi n arterial sist lica o diast lica es alto o bajo a presi n arterial var a en respuesta a cambios puntuales de su estado mental como por ejemplo la reacci n ante la presencia de un m dico Rel jese durante 4 5 minutos y tome otra medici n Consulte la p gs 40 y 43 Pida consejo a su m dico No aparece ning n indicador incluso Las pilas se han colocado con las polaridades incorrectas despu s de pulsar el bot n Consulte la p g 37 encender parar Si el problema persiste Cuan
37. rferencia utilice la unidad a una distancia suficiente de esos dispositivos o ap guelos 7 El tensi metro fue dise ado para que lo utilicen los adultos Consulte al m dico antes de usarlo para un nifio No lo utilice para criaturas ni beb s 8 La unidad no es apta para monitoreo continuo durante emergencias m dicas ni operaciones 9 No la utilice para ning n otro fin que no sea medir la presi n sangu nea No la utilice junto con otros dispositivos 10 El manejo incorrecto de las pilas puede provocar la ruptura de la pila o corrosi n causada por la fuga de las pilas Tenga en cuenta lo siguiente para garantizar el uso correcto de las pilas a Apague el tensi metro despu s de utilizarlo b No mezcle pilas de diferentes tipos ni tama os c Cambie todas las pilas al mismo tiempo No mezcle pilas viejas con nuevas d Inserte las pilas con la polaridad correcta seg n las instrucciones e Extraiga las pilas cuando est n agotadas y des chelas seg n las disposiciones ambientales aplicables f No desarme las pilas ni las arroje al fuego g No les provoque un cortocircuito h No intente recargar las pilas que vienen incluidas en la unidad 31 Precauciones para garantizar un funcionamiento seguro y fiable No deje caer la unidad Prot jala contra sacudidas o descargas repentinas No inserte objetos extra os en las aberturas No intente desarmar la unidad Si guarda la unidad a temperaturas inferiores a los 0
38. s lower during sleep and higher when he or she is active Blood pressure can change easily in response to physiological changes The setting in which a person s blood pressure is measured can also affect the results Having one s blood pressure measured by a healthcare professional in a hospital or clinic can cause nervousness and may result in a temporarily elevated reading Because blood pressure measurements taken in a clinical setting can vary considerably from those taken at home a person s blood pressure should be measured not only occasionally in the doctor s office but also on a regular basis at home Also if you find that your blood pressure is lower at home this is not unusual To accurately compare with your physician s reading take your Panasonic blood pressure monitor to your doctor s office and compare readings in this setting People suffering from cardiac arrhythmia vascular constriction liver disorders or diabetes people with cardiac pacemakers or a weak pulse and women who are pregnant should consult their physician before measuring their blood pressure themselves Different values may be obtained due to their condition Try to take your blood pressure measurements at the same time and under the same conditions every day e The ideal time to measure your blood pressure to obtain your so called base blood pressure is in the morning just after waking up before having breakfast and before any major activity or exercise
39. s personas que se est n medicando para regular la presi n arterial puede variar mucho debido a los efectos de la medicaci n G Cuando realice dos mediciones consecutivas permanezca quieto durante 4 5 minutos entre la primera y la segunda medici n Por qu difieren los resultados de una medici n hecha utilizando el brazo izquierdo de los obtenidos con el brazo derecho Se ha comprobado que la diferencia entre los valores de presi n arterial de los brazos izquierdo y derecho puede estar alrededor de los 10 mmHg La presi n sangu nea se puede medir lo mismo en el brazo izquierdo que en el derecho pero para prop sitos de comparaci n todas las mediciones deben hacerse usando el mismo brazo 50 CUIDADO Y MANTENIMIENTO No aplique fuerza excesiva sobre el instrumento ni lo deje caer e Hacer esto puede causar da o Si el instrumento se guarda a temperaturas por debajo del punto de congelaci n no lo use inmediatamente D jelo en un lugar c lido durante al menos una hora antes del uso e Si no se permite que el instrumento se caliente puede que no presurice No introduzca polvo ni objetos dentro del instrumento e Hacer esto puede causar dario Si el instrumento se ensucia l mpielo con un pafio suave humedecido con agua tibia o agua jabonosa No use alcohol benzina ni diluente de pinturas El uso de esas sustancias qu micas puede causar agrietamiento o decoloraci n Para guardarlo evite tem
40. see p 19 The pulse rate value is the beats per minute calculated based on the pulse rate during measurement Remove your arm from the main unit To switch off the blood pressure monitor Press the On Off Start button e f you forget to switch it off the blood pressure monitor will switch off automatically after approximately 5 minutes Alarm function signals high blood pressure Blood pressure values for both systolic and diastolic readings are determined and indicated via a three color LED system as being within normal or hypertensive ranges based on definitions and classification of blood pressure levels by the JNC 7 Moreover when blood pressure is in the high range the reading displayed on screen flashes on and off to alert user According to JNC 7 Classification values consistently in excess of 140 mmHg Sys and or 90 mmHg Dia are considered to constitute high blood pressure LED Color Diastolic mmH eran e Hypertension 140 H ange Stage 1 Stage 2 120 D s N Yellow Prehypertension 90 A 80 80 H Green Normal l 120 140 mmHg Systolic e Ifthe measured blood pressure value is in the high blood pressure region the values will blink for approximately 12 seconds Only immediately after measurement e Systolic blood pressure 140mmHg or higher e Diastolic blood pressure 90mmHg or higher If measurements could not be taken properly The remeas
41. stra en la ilustraci n de la derecha Deslice su brazo por la secci n de medici n Acerque hacia usted la unidad principal para que no tenga que inclinarse para alcanzarla e Qu tese la camisa o rem nguesela de forma que la secci n de medici n quede en su piel desnuda e Si remangarse la camisa causa un aumento de presi n en su brazo o antebrazo qu tese la camisa para las mediciones Aseg rese de que la manga remangada no quede dentro de la secci n de medici n al hacer e las mediciones N Coloque su cow en el soporte ES Soporte para e Si fuera dif cil encontrar el soporte para codo use codo Su otra mano para encontrarlo Extienda su brazo y si ntese derecho e Cuando coloca su mano sobre la mesa en una posici n relajada la unidad se voltear de forma natural 15 hacia arriba 39 PRECAUCIONES DURANTE LAS MEDICIONES Resultar imposible realizar mediciones precisas en las situaciones siguientes OMenos de una hora despu s de comer o ingerir alcohol Olnmediatamente despu s de beber caf o t o de fumar Olnmediatamente despu s de hacer ejercicio o de ba arse Espere como m nimo 20 minutos y t mese la presi n estando quieto a y en reposo ODentro de un veh culo en movimiento OEn lugares fr os T mese la presi n con una temperatura ambiente comprendida entre los 10 y los 40 C 50 F a 104 F OCuando necesite orinar Despu s de orinar espere unos minutos a
42. tidamente el bot n Pulse el bot n ajuste 2 para ajustar el d a encender parar para Ld apagar la unidad Cuando parpadean la fecha o la hora el reloj est detenido En los a os de traspaso ser necesario cambiar manualmente la fecha el d a 29 2 la unidad pasar por defecto al 1 3 Use la punta de un bol grafo u objeto similar para pulsar ligeramente los botones ajuste 1 y 2 Si usa un l piz la mina puede romperse causando mal funcionamiento 38 Colocaci n en la posici n para la medici n Puede medir lo mismo en el brazo izquierdo que en el derecho Sin embargo cuando las mediciones se realicen en el brazo derecho puede ser dif cil ver la pantalla Debido a que puede haber una diferencia de aproximadamente 10mmHg en la presi n sangu nea entre el brazo izquierdo y el derecho aseg rese de usar siempre el mismo brazo para las mediciones El producto no puede usarse estando acostado Si ntese erguido durante el uso Coloque la unidad principal sobre una mesa u objeto similar de forma que quede a la misma altura de su coraz n Las diferencias de altura pueden causar diferencias en los valores de la presi n sangu nea Si las alturas de la silla y de la mesa no son las apropiadas puede ser que tenga que inclinarse hacia adelante En este caso haga una pila con libros u objetos similares debajo de la unidad principal para ajustar la altura de la misma fu Si ntese cerca de la mesa como se mue
43. to Niveles de humedad a temperatura de almacenamiento de 10 a 95 de humedad relativa de 20 a 60 C 4 F a 140 F Circunferencia m nima y m xima del brazo De 20 a 34 cm 7 3 4 a 13 1 4 aproximadamente Peso 4 9 lbs 1 200 g aproximadamente sin incluir las pilas Dimensiones 22 x 15 5 x 21cm 8 21 32 x 6 3 32 x 8 1 4 de 15 a 90 de humedad relativa de 10 a 40 C 50 F a 104 F Especificaciones Adaptador de CA PRECAUCIONES DURANTE LAS MEDICIONES Resultar imposible realizar mediciones precisas en las situaciones siguientes Menos de una hora despu s de comer o ingerir alcohol D Se Inmediatamente despu s de hacer ejercicio o de ba arse Nen Espere como m nimo 20 minutos y t mese la presi n estando quieto a y en reposo En lugares fr os T mese la presi n con una temperatura ambiente comprendida entre los 10 y los 40 C 50 a 104 F 48 Inmediatamente despu s de beber caf o t o de fumar Y E EN Dentro de un vehiculo en movimiento 2 Cuando necesite orinar N fi Ve A Despu s de orinar espere unos minutos antes de tomarse la presi n PREGUNTAS Y RESPUESTAS P R Por qu difieren los resultados que obtengo al tomarme la presi n en casa de los que obtengo cuando me la toma mi m dico La presi n arterial var a las 24 horas del d a Asimismo puede variar mucho en funci n del tiempo de
44. ttery rupture or in corrosion from battery leakage Please observe the following to ensure proper use of batteries a Be sure to turn off the power after use b Do not mix different types or sizes of batteries c Change all batteries at the same time Do not mix old and new batteries d Be sure to insert batteries with correct polarity as instructed e Remove batteries when they are worn out and dispose of them properly according to all applicable environmental regulations f Do not disassemble batteries or throw them into a fire Do not short circuit batteries Do not attempt to recharge the batteries included with the unit JQ Precautions to Ensure Safe Reliable Operation Do not drop the unit Protect it from sudden jars or shocks Do not insert foreign objects into any openings Do not attempt to disassemble the unit If the unit has been stored at temperatures below 0 C 32 F leave it in a warm place for about 15 minutes before using it Otherwise the cuff may not inflate properly Do not store the unit in direct sunlight high humidity or dust When cleaning unplug the AC adapter from the AC outlet before cleaning Also do not plug in or unplug the AC adapter with wet hands Doing so may result in electric shock or fire 7 Do not spill water on the main body or AC adapter Doing so may cause electric shock short circuiting or product damage 8 Donotuse the AC adapter if it is damaged or if it plugs into the
45. tton is pressed and then the display goes blank No display appears even if the On Off Start button is pressed X Approximately 200 measurements approximately 2 months when measurements are taken 3 times per day can be taken with a set of fresh Panasonic alkaline batteries four AA size LR6 batteries Measurement conditions Room temperature 22 C 72 F Pressurized to 170mmHg Upper arm circumference 30cm 11 51 64 The supplied batteries are included for trial purpose only Accordingly there is no guarantee regarding the length of their useful lives Even if the product is not used for a long time be sure to replace batteries once a year If battery replacement is delayed damage due to battery leakage may occur e When replacing batteries always use four fresh alkaline batteries of the same type from the same manufacturer e When room temperature is low battery life may become shorter 11 BEFORE STARTING MEASUREMENTS Open the display Press the Open button for display on the front of the main unit The display will only open partially by itself Use your hand to open the display fully for use Setting the date and time Please be sure to set the date and time before taking the first measurement after purchasing the blood pressure monitor or after changing the batteries e If measurements are taken without setting the date and time the date and time will not be stored Please read the
46. ure mark E will be displayed When taking successive measurements press the On Off Start button to switch off the blood pressure monitor once and stay quiet for 4 to 5 minutes and then take the next measurement Advice In general blood pressure measurements are lower for the second measurement because you are less nervous and are more tranquil For people who easily get tense measuring twice each time is very effective When two measurements are taken normally the smaller measurement is stored When taking two measurements always stay quiet for 4 to 5 minutes after the first measurement before taking the second measurement 17 To interrupt measurements quickly If the pressure cuff will not Push and hold deflate even if the On Off Start button is pressed press the Quick air release button and hold it pressed The air will be released in approximately 4 seconds If the pressure cuff comes off With the belt and seam downwards slide the pressure cuff into the main body Z Belt With the belt and seam downwards slide the pressure cuff into the main body Pressure cuff TO Press the pressure O a cuff INTO the groove of the main body Either the front or the back can be attached first Groove When re attaching be sure not to touch the inside of the main body where the pressure cuff has been removed Doing so may result in an accident or injury 18 STORING MEAS
47. y into the AC outlet An operating sound may be heard momentarily when the AC adapter is plugged into the outlet Be sure to use only the exclusive AC adapter included accessory Use of other AC adapters could cause an accident Caution when using only the AC adapter When no batteries are installed in the main unit and the AC adapter is unplugged from the AC outlet or main unit the set date and time will be reset and deleted Because of this even when using the AC adapter it is recommended that batteries be installed in the main unit When the AC adapter is used power is supplied from the AC adapter so virtually no power from the batteries is used 10 WHEN USING BATTERIES Always use alkaline batteries Four AA size LR6 alkaline batteries Use only alkaline batteries Do not use other types of batteries Turn the main body over press lightly on the ZA mark on the battery cover and remoOVe the cover by sliding it in the direction of the arrow Battery holder Slide the battery holder OUT in the direction of the arrow Check the polarities of the batteries and Install them correctly Slide tne battery holder back in An operating sound may be heard momentarily when the battery holder is put back in Battery cover Replace the battery cover and slide i Closed Replace batteries when e The mark shown at left appears during use e All displays are lit for a moment after the On Off Start bu
48. zado con su historia cl nica debe interpretar las mediciones de la presi n sangu nea Si est tomando medicinas consulte con su m dico para determinar el momento m s adecuado para tomar la presi n NO cambie un medicamento recetado sin haber consultado antes al m dico La presi n sangu nea puede variar seg n diversos factores incluidos la edad el sexo el peso y el estado f sico En general la presi n sangu nea de una persona es menor cuando duerme y mayor cuando est en actividad Puede cambiar con rapidez en respuesta a los cambios fisiol gicos El entorno en el cual se toma la presi n tambi n puede afectar los resultados El hecho de que un profesional de la salud le tome a uno la presi n en un hospital o en una cl nica puede provocar nervios y traducirse en una lectura temporariamente elevada Puesto que las mediciones de la presi n arterial tomadas en un entorno cl nico var an considerablemente respecto de las tomadas en casa se debe tomar la presi n no solo en el consultorio sino tambi n en el hogar en forma frecuente Asimismo no debe sorprenderse si descubre que la presi n es menor en casa Para comparar con exactitud con la lectura del m dico lleve el tensi metro Panasonic al consultorio y compare ambas lecturas en ese entorno Quienes padecen arritmia cardiaca constricci n vascular trastornos del h gado o diabetes quienes tienen colocado marcapasos o pulso d bil y las embarazadas deben consultar con

Download Pdf Manuals

image

Related Search

Related Contents

Manual do Usuário BOMBA DE VACUO MANUAL KA-056  Eminent EM6552 power extension  STEYR AUG Z - Steyr Mannlicher  Fluke 875 Computer Monitor User Manual  FAQ(ょくある質問) り本製品自体は蓄電できるのですか?  Besta CD-608 Dictionary  Pure Sinewave Inverter  Monographie du produit ICLUSIG  1 USER MANUAL ^2 Accessory 72EX  

Copyright © All rights reserved.
Failed to retrieve file