Chief PCM2542 flat panel ceiling mount

image

Contents

1. 2 Lower display into place listening for audible click to ensure recessed area of mounting buttons are properly seated in lower area of mounting holes and click lock mechanism has engaged See Figure 4 and See Figure 5 Figure 4 Holes are provided in the faceplate for use with a padlock or similar locking device if desired In addition the pin and nut may be removed from the upper holes and moved to the lower holes for use as a more permanent locking device See Figure 5 NOTE Installation Instructions PCM SERIES Display Roll Adjustment a To adjust display roll Q 1 Loosen 3 8 16 Nylock nut See Figure 7 Touseasa P a 2 Adjust faceplate to desired position See Figure 7 more permanent 3 Tighten 3 8 16 Nylock nut See Figure 7 lock remove pin and nuts and move to lower holes A padlock or bolt may be placed through latch holes Figure 5 Adjustments The PCM is designed to accommodate 5 of display height adjustment 4 right and left display roll adjustment and 15 down 5 up display pitch Tilt adjustment Remove display before performing adjustments Figure 7 Display Pitch Tilt Adjustment To adjust display pitch Display Height Adjustment To adjust display height 1 Loosen four 5 16 18 button head cap screws using 3 16 hex wrench C See Figure 6 1 Loosen four 5 16 18 button head cap s
2. 4 Thread the tube assembly A onto 1 1 2 NPT NOTE The product is suitable for use with a Listed ceiling plate which can accommodate 1 1 2 NPT pipe and has a rated weight capacity of 200 Ibs 91 kg 5 Secure faceplate B to faceplate mounting bracket using 3 16 hex wrench C and four 5 16 18 x 1 2 button head cap screws D Figure 3 Display Installation If the mounting pattern of the display being installed is a VESA standard 200 x 200 pattern the mounting buttons can be installed directly to the back of the display If the display has any other mounting pattern an interface bracket must be obtained before proceeding Consult a Chief Customer Service representative if an interface bracket is required by calling 1 800 582 6480 or visit www chiefmfg com WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT Displays can weigh in excess of 40 Ibs 18 1kg ALWAYS use two people and proper lifting techniques when installing display WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT Make sure mounting buttons on display are properly seated in mounting holes in faceplate To install display 1 While supporting both sides of display align four mounting buttons on display or interface bracket with four mounting holes in faceplate See Figure 4
3. INSTALLATION INSTRUCTIONS Plasma Ceiling Mount SI CHIEF PCM SERIES PCM SERIES Installation Instructions DISCLAIMER Milestone AV Technologies Inc and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document A IMPORTANT WARNINGS AND CAUTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations CoxMure 3acTeKky WARNING Failure to read thoroughly understand and fol
4. crews 2 Adjust faceplate to desired position See Figure 6 See Figure 8 A 3 Tighten four 5 16 18 button head cap screws using 3 16 2 Adjustto desired tilt position See Figure 8 hex wrench C See Figure 6 3 Soe Figure Be button head cap screws I Fi Figure 6 guies PCM SERIES Installation Instructions Installation Instructions PCM SERIES PCM SERIES Installation Instructions Chief and ClickConnect are trademarks of Milestone AV Technologies Inc All rights reserved G CHIEF Chief Manufacturing a division of Milestone AV Technologies 8805 000114 RevE 2008 Milestone AV Technologies www chiefmfg com 04 08 USA International A 8401 Eagle Creek Parkway Savage MN 55378 P 800 582 6480 952 894 6280 F 877 894 6918 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 24F Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA AIT p zx 27 MN BAR AB E XA IB DR 24F P 86 755 8996 9226 F 86 755 8996 9217 A FN X 4 9 Que Me va
5. le Zeskantsleutel Cl a t te hexagonale FnaBHbi BeAbMON PbIBOK Open Ended Wrench Llave de boca Gabelschl ssel Chave de bocas Chiave a punte aperte UC gt 4 Steeksleutel Cl a fourche OTKpbITbIN PbIBOR Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis a pointe cruciforme OrBeprka Installation Instructions PCM SERIES TOOLS REQUIRED FOR INSTALLATION AND PARTS 3 16 provided DIMENSIONS 26 42 MIN NOTE CUSTOM INTERAFCE BRACKET 31 42 MAX NOT SHOWN THE CUSTOM INTERFACE TO APPROX CENTER BRACKET NEEDED FOR YOUR DISPLAY WILLADD BETWEEN 1 2 AND 2 IN DEPTH OF DISPLAY AND MAY AFFECT LOCATION OF DISPLAY ON THE MOUNT SEE PSB XXXX DRAWING ALSO FACE TILTS 5 UP 25 DOWN N 19 44 VERTICAL ADJUSTMENT APPROXIMATE CENTER OF DISPLAY Figure 1 PCM SERIES Installation Instructions Mount Assembly and Installation 1 Fold tube out until tube mounting bracket rests against faceplate mounting bracket See Figure 2 2 Secure tube to faceplate mounting bracket using 3 16 hex wrench C and two 5 16 18 x 1 2 button head cap screws D 3 Tighten all hardware Figure 2
6. low all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for the installation of this kit can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this mount is attached can support five times the combined weight of all equipment WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components attached to this mount does not exceed 200 Ibs 91 kg WARNING The installer is responsible for verifying that the 1 1 2 NPT fixture this mount is installed on is capable of supporting four times the maximum weight capacity of the mount as stated above Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster Mpucnocobbrecb Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Ocnabbre 3acrexxy Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabeca sextavada Chiave esagona