Home

Chief FSA1015B rack accessory

image

Contents

1. from table below NOTE All spacers used should be the same length If recess depths result in multiple spacer lengths then select the longer spacer IF recess DEPTH is THEN use spacer AND screw Figure 4 Install Upper Display Screws Flush Mount 5 Pickup and orient display interface so that the screws installed in the previous step fit into the upper mounting holes in bracket 10 See Figure 5 Lower display firmly into place Display 90 2 places shown gt 10 3 places similar Figure 5 Install Display Flush Mount 6 From the back of the equipment rack and using Phillips screwdriver install remaining two or three if applicable screws 90 through bracket 10 into the lower display mounting holes See Figure 5 7 Tighten all four or six if applicable screws Do not overtighten Install all cables 9 Installation is complete INSTALLATION OPTION B 1 Install interface to display if required See instructions supplied with interface 2 Carefully place display face down on protective surface More than zero up to 120 3 8 long 100 M4 x 20mm and including 3 8 More than 3 8 up to and including 3 4 130 3 4 long 110 M4 x 30mm 5 Place the selected spacers over each of the mounting holes on the back of the display 6 Pick up and orient the FSA 1015 assembly such that the mounting holes in bracket 10 ar
2. INSTALLATION INSTRUCTIONS 19 EQUIPMENT RACK ACCESSORY Model FSA 1015 Specifications e Designed for equipment rack with 19 wide vertical attach rails AA AN e Accommodates the following installation a 3 configurations Direct installation of VESA compliant display interface 75x75mm 100x100mm and 100x200mm FWD Cynergy Wall Mount FSR and FTR Fusion Wall Mounts e Weight capacity of 30 Ibs 13 kg FSA 1015 Shown with optional Equipment Rack FTR and FWD mounts BEFORE YOU BEGIN WARNING It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty e Ifyou have any questions about this these instructions or your specific installation contact Chief Manufacturing at 1 800 582 6480 or 952 894 6280 CHIEF MANUFACTURING INC 8804 000307 i 1 800 582 6480 952 894 6280 FAX 952 894 6918 2006 Chief Manufacturing NV 8401 EAGLE CREEK PARKWAY STE 700 www chiefmfg com Ideas Supporting Ideas SAVAGE MINNESOTA 55378 USA 03 06 Model FSA 1015 Installation Instructions A IMPORTANT WARNINGS AND CAUTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instruction
3. e aligned with the holes in the spacers See Figure 6 100 or 110 1 NOTE 100x100mm 4places 4 f VESA mounting hole AN if i pattern shown 75x75mm ii i and 100x200mm pattern similar 10 lt lt FSA 1015 i ii Assembly 120 or 130 gt 4 places 7 Figure 6 Install Display Recessed Mount CAUTION Using screws of improper size may damage your display Proper screws will easily and completely thread into display mounting holes 7 Using Phillips screwdriver install four or six if applicable of the selected screws through the mounting holes in bracket 10 through the spacers into the display 8 Tighten all four or six if applicable screws Do not overtighten 9 Proceed to ASSEMBLY PART 2 10 Install all cables 11 Installation is complete Model FSA 1015 Installation Instructions INSTALLATION OPTION C 1 Install interface to display if required See instructions supplied with interface 2 Using Phillips screwdriver and 7 16 wrench install two screws 60 through 10 washers and wall bracket supplied with FWD mount FSA 1015 assembly and bracket 80 into nuts 70 See Figure 7 Tighten screws 60 FSA 1015 80 Assembly 70 2 places oo NY Wall Bracket 0 Washers 60 2 places 2 places Figure 7 Install FWD Wall Bracket Proceed to ASSEMBLY PART 2 below 4 Install d
4. ing FWD Cynergy Wall Mount Applicable to VESA compliant display 75x75mm or 100x100mm mounting hole pattern Non VESA compliant display also requires installation of interface purchased separately contact Chief Manufacturing at 1 800 582 6480 for more information e OPTION D Installation with Existing FSR or FTR Fusion Wall Mount Requires installation of interface purchased separately contact Chief Manufacturing at 1 800 582 6480 for more information INSTALLATION OPTION A 20 1 Install interface to display if required See Si 2 places instructions supplied with interface 2 Proceed to ASSEMBLY PART 2 i Carefully place display face down on protective surface CAUTION Using screws of improper size may damage your display Proper screws will easily and completely thread into display mounting holes 4 Using Phillips screwdriver install two or three if applicable screws 90 completely into the upper display mounting holes then back out 4 full turns See Figure 4 NOTE Do NOT install screws 90 into the ower display mounting holes at this time Figure 3 Install Side Brackets 1 Extension 3 Proceed to INSTALLATION Installation Instructions Model FSA 1015 x 90 2 places shown 3 places similar Display SN ve e Le 3 Determine depth of mounting holes relative to the back surface of display 4 Select proper length spacer and screw
5. isplay to wall mount See instructions supplied with FWD mount 5 Install display wall mount assembly to wall bracket now installed in equipment rack See instructions supplied with FWD mount 6 Install all cables 7 Installation is complete INSTALLATION OPTION D 1 Install interface to display See instructions supplied with interface 2 Using Phillips screwdriver and 7 16 wrench install four screws 50 through wall mount and bracket 10 into nuts 70 See Figure 8 See Figure 9 Tighten screws 50 70 4 places gt 3 5 N Figure 9 Install FTR Wall Mount Proceed to ASSEMBLY PART 2 below 4 Install display to wall mount now installed in equipment rack See instructions supplied with FSR FTR mount Install all cables 6 Installation is complete Installation Instructions Model FSA 1015 ASSEMBLY PART 2 WARNING Failure to use proper fasteners can result in serious personal injury or damage to equipment Screws 30 and 40 supplied for convenience only 1 Using Phillips screwdriver install FSA 1015 assembly to equipment rack using four screws 30 40 or other fasteners as applicable See Figure 10 Tighten fasteners 30 or 40 4 places Equipment Rack Rail left side shown right side similar NOTE Display mount not shown for clarity Figure 10 Instal
6. l FSA 1015 to Equipment Rack 2 Return to INSTALLATION OPTION A B C or D as applicable Model FSA 1015 Installation Instructions
7. nted in front of OR flush with equipment rack If display width is 17 or less then bracket 10 may be mounted at any location e Depth of mount and or interface if used e Extent of pitch roll yaw height and or extension desired as applicable for each mount Using Phillips screwdriver install screws 50 through brackets 20 into desired threaded holes in bracket 10 See Figure 2 See Figure 3 Ensure brackets 10 and 20 are oriented as shown Tighten screws 50 50 Four installation options exist e OPTION A Installation without Existing Wall Mount NOTE This option REQUIRES a display having mounting holes that are flush with the back surface AND where access to the back of the equipment rack is possible If one or both of these requirements are not met proceed to OPTION B below Applicable to VESA compliant display 75x75mm 100x100mm or 100x200mm mounting hole pattern Non VESA compliant display also requires installation of interface purchased separately contact Chief Manufacturing at 1 800 582 6480 for more information OPTION B Installation without Existing Wall Mount Applicable to VESA compliant display 75x75mm 100x100mm or 100x200mm mounting hole pattern Non VESA compliant display also requires installation of interface purchased separately contact Chief Manufacturing at 1 800 582 6480 for more information e OPTION C Installation with Exist
8. s CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components attached to the FSA 1015 including the mount if required and display does not exceed 30 Ibs 13 kg DIMENSIONS 6 04 153 47 MAX RECESSED 96 24 33 MAX 17 03 432 59 a He EXTENSION MAX DISPLAY WIDTH 7 87 200 86 21 84 3 49 88 52 Dassi o o o o o o o 3 94 100 E 2 95 5 25 133 35 LJ 1 o o 0 0 0 0 0 7X 1 00 2540 DEPTH ADJUSTMENT ja 48 94 481 01 Installation Instructions Model FSA 1015 TOOLS REQUIRED FOR INSTALLATION 2 Phillips Screwdriver e 7 16 Wrench for installation of existing FWD Wall Mount NOTE O
9. ther tools may be required depending on your method of installation PARTS After unpacking carton inspect and verify contents See Figure 1 If any listed parts are missing or damaged contact Chief Customer Service at 1 800 582 6480 Table 1 Parts BAG B Item Description Qty l 10 BRACKET Display Mounting 1 40 47 20 BRACKET Side 2 SI 30 SCREW Phillips Pan Machine 10 32 x 1 2 4 40 SCREW Phillips Pan Machine 12 24 x 1 2 4 BAG C 50 SCREW Phillips Pan Machine 10 24 x 1 2 8 Ce 60 SCREW Phillips Pan Machine 10 24 x 1 1 4 2 50 70 NUT Nylock Short 410 24 4 80 BRACKET FWD Wall Mount 1 90 SCREW Phillips Pan Machine M4 x 12mm 6 a 80 100 SCREW Phillips Pan Machine M4 x 20mm 6 60 I 110 SCREW Phillips Pan Machine M4 x 30mm 6 120 SPACER Nylon 3 8 6 AN 130 SPACER Nylon 3 4 6 se i O BAG D 90 100 110 Figure 1 Parts Model FSA 1015 Installation Instructions INSTALLATION Determine how display is to be installed to FSA 1015 ASSEMBLY PART 1 1 Determine location of bracket 10 in equipment rack Location is adjustable in 1 increments from approximately 6 depth within rack to 1 extension in front of rack Consider the following items e Size of display If display width i e width of case not screen size is greater than 17 then bracket 10 must be mou

Download Pdf Manuals

image

Related Search

Related Contents

Oracle Database Gateway for ODBC User's Guide  Canon CP750 Printer User Manual  IRTEC Serie G (A-F)  Baker OD6 Installation Instructions - the official baker drivetrain store  Manual - WIKA Worldwide  Operating Instructions For The Powerbond TR70  Worldwide Homefurnishings 401-896 Instructions / Assembly  EzCad2.8UNI User`s Manual  