APC Symmetra LX 16kVA Scalable to 16kVA N+1 Ext. Run Tower, 208/240V

image

Contents

1. 3 If the output voltage is not correct for your application use the arrow keys and ENTER to select Output The cursor will move to the voltage field as the up and down arrows scroll through available choices Choose the desired voltage setting and press ENTER to select Self Test Enabled UPS ID UPS_IDEN Vout Reporting AUTO gt Output 208V Supply Power to the Load Equipment The Symmetra LX must be turned on before executing this procedure 1 Press Esc until the Main Menu appears Use the arrow keys to choose Control and ENTER to select gt Control Logging Status Display Setup Diags Accessories Help 2 Use the arrow keys to choose Turn UPS Output On and ENTER to select NOTE You must scroll to a second page of choices Graceful Turn Off Start Runtime Cal gt Turn UPS Output On 3 Confirm choice by selecting YES Confirm Turn UPS On CANCEL gt YES Turn UPS On 4 There will be clicking sounds and this message will appear NOTE You may be given one or more override warnings Answer these by selecting Start Now UPS HAS BEEN COMMANDED TO TURN LOAD POWER ON CHAPTER 2 BASIC COMMANDS 5 In approximately 90 seconds the green Load On indicator will illuminate and this message will appear UPS LOAD IS ON Press any key Turn Off UPS Output Power and Load Equipment 1 P
2. since last ON At least one power module has been added or removed from the UPS since the last time the Pwr ON command was issued Batteries changed since last ON At least one battery module has been added or removed from the UPS since the last time the Pwr ON command was issued No corrective action necessary Proceed with the start up No Redundant Intelligence Module IM There is no redundant intelligence module installed and working Proceed with the start up or abort the start up and install a new IM Note Without two functioning IMs there is no redundancy in the event of an IM failure Batt capacity less than Return Batt Cap The battery capacity of the UPS is less than the user specified minimum battery capacity required to turn on the load Option 1 Abort the start up and allow batteries to recharge Option 2 Continue start up with less than minimum battery capacity Input Freq outside configured range The input frequency to the UPS is outside the configured range The output frequency will not synchronize with the input frequency Normal bypass is not available The system will start on battery Option 1 Improve the frequency of the incoming voltage Option 2 Widen the range of the acceptable incoming frequency with the PowerView Startup gt Setup gt OuputFreq Option 3 Proceed with start up Normal bypass is not available and system may st
3. NDS Display Menu The Display Menu allows the user to customize the PowerView display Date Time Sets the correct date and time Date dd mmm yyyy Ex 11 Aug 2003 Time hh mm ss Ex 21 36 10 Protects against unauthorized Password configuration changes Valid characters include Password Sets a password A Z or 0 9 Type _ to complete Puts password into effect Prevents Invalidate unauthorized changes to the UPS configuration Displays PowerView model number Information serial number date of manufacture and revision information Sets audible alarm beeper criteria AtUPS Not used with the UPS Sets parameters for the audible alarm in Power Failure At Display the PowerView Power Failure 30 seconds Low Battery or Never Sets audible alarm volume Off Low default Medium or High Sets sound when pressing display On default Off buttons Sets LCD screen contrast 0 1 2 3 4 5 6 0r 7 Customizes the information displayed on Use factory defaults when Config the Startup screen possible 10 CHAPTER 3 MENU COMMANDS Diagnostics Menu The Diagnostics Menu provides useful information for troubleshooting Fault and Diagnostics Displays current system fault and diagnostic information of that fault Main Intelligence Module Displays detailed intelligence module status and information Redundant Intelligence Module Power Modules Displays detailed power module status and information Displa
4. Symmetra LX Operations Guide For use with Symmetra LX UPS Models 200 V 4 8 kVA 200 V 4 16 kVA 208 240 V 4 8 kVA 208 240 V 4 16 kVA 220 230 240 V 4 8 kVA 220 230 240 V 4 16 kVA Symmetra LX Rack mount UPS g y zy Symmetra LX Rack mount Extended Run o SS A al 4 a Ny z A NS a E z E e o a LO A Symmetra LX Tower UPS Symmetra LX Tower Extended Run APC www apc com 990 1546A 001 06 2005 TABLE OF CONTENTS Chapter Ts OVeIViWissiccicaic ii iii iii dana 1 PIE cias 1 Keys Mica ii ie ae A i ee i ena ee ae 1 Navigation nese ena tata neil divs ae in Sel ei ieee a eee eee iste 2 Chapter 2 Basic COMMANGS 3 isis ciesc ies creates a aart esssceccebeadoncsdasteasestioverssctestedesdeusndavesaye 3 Supply Power to the UPS seeti esas paved eceacads Seaest ac dicdecendardsovecectesvssbeneesdiee Seadecuedevgdeetdads dpvbddae suede e aeaiee 3 Set the Correct Output Voltage israe ioiei iae e it 4 Supply Power tothe Load Equipment edida ie bees aae idolo decia 4 Turn Off UPS Output Power and Load EquipM6Nt oocconocccncococcnononcncnono nono nono ncnn non n nc canon nr n nan rra 5 Bypass Opera iii Aisa 5 LANGUAGE Setting irienna saneevegdduagusudenessuuegeeesunesteecuershteooes 7 Language Setting CONNU A a a aa aaa ae a a ae nece ner nn Ea r EE E TE aa era aie ENE arime 8 Chapter 3 Menu Comma
5. The battery capacity has decreased or the load has increased Option 1 Allow the battery modules to recharge Option 2 If possible increase the number of battery modules Option 3 Decrease the load Option 4 Use the PowerView to decrease the minimum runtime alarm threshold Startup gt Setup gt Alarms gt Runtime Bypass Bypass is not in range either freq or voltage The frequency and or voltage are out of acceptable range for bypass This message occurs when the UPS is online and the bypass mode is unavailable The system may start on battery Option 1 Decrease the sensitivity to input frequency Startup gt Setup gt OutputFreq Option 2 Correct input voltage to provide acceptable voltage and or frequency Bypass contactor stuck in bypass position The UPS is positioned in the bypass position and cannot go on line Bypass contactor stuck in on line position The UPS is positioned in the on line position and cannot go to bypass UPS in bypass due to internal fault The UPS has transferred to bypass mode because a fault has occurred Call your contract service provider or APC Technical Support UPS in bypass due to overload The load exceeded the system power capacity The UPS has switched to bypass mode Option 1 Decrease the load Option 2 If possible add power modules to the system System is in Maintenance Bypass The UPS is in bypas
6. Web site for contact numbers and support at http www apc com Battery Replacements Kits and Battery Recycling See your dealer or visit the APC web site at http www apc com for information on battery replacement kits and battery recycling If returning used batteries to APC for recycling ship used batteries in the battery replacement packing material Entire contents copyright 2005 by American Power Conversion Corporation All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo Symmetra InfraStruXure Smart UPS and PowerChute are registered trademarks of American Power Conversion Corporation All other trademarks are the property of their respective owners 21
7. art on battery power 15 CHAPTER 4 TROUBLESHOOTING Condition PowerView Message Reason Corrective Action Start Up continued AC adequate for UPS but not for bypass The UPS will function on line with the input voltage But in the event that bypass is required the input voltage is not adequate to power the load equipment Option 1 Improve the incoming voltage Option 2 Proceed with start up Normal bypass is not available Low No AC input start up on battery Input voltage is not adequate to start the UPS If start up continues the UPS will function from battery Option 1 Abort start up until acceptable input voltage is present Option 2 Proceed with start up Battery will be discharged General Status of batteries increased At least one battery module has been added to the system of batteries decreased At least one battery has been removed from the system of Pwr Modules increased At least one power module has been added to the system Intelligence Module inserted An intelligence module has been installed in the lower IM slot Intelligence Module removed An intelligence module has been removed from the lower IM slot Redundant Intelligence Module inserted An intelligence module has been installed in the upper IM slot Redundant Intelligence Module removed An intelligence module has been removed fr
8. ay interval that allows utility power to 0 default 20 60 120 240 stabilize before the system goes back online aftera 480 720 or 960 seconds utility power failure Return Battery Sets the minimum battery capacity necessary O default 15 25 35 50 Capacity before repowering the load when returning from an 60 75 or 90 seconds extended utility power failure Output Freq uency The UPS output will phase lock to the input within 50 3 Hz 50 0 1 Hz 60 this range 3 Hz 60 0 1 Hz Full range tracking 13 CHAPTER 3 MENU COMMANDS Setup Menu continued 0 Redundancy An audible alarm sounds if the redundancy falls default 1 or 2 below this level Load An audible alarm sounds when the load exceeds Never default 1 2 3 4 5 this limit Upper value is limited by the maximum 6 7 8 9 10 or 12kVA power of the UPS Runtime An audible alarm sounds if the available runtime 0 0 default 5m 10m 15m falls below this level Hours min 30m 45m 1h 2h 3h 4h 5h 6h 7h or 8h Bypass If the UPS fails and the input voltage or line Go to Bypass or frequency is outside of normal range this option Drop Load allows the user to choose Bypass mode or drop the load Copy Select the configuration that you wish to move UPS Options include data into or out of and then select the direction that Configuration Number from you wish to move the data UPS to Display and from Note Copying data between different
9. beeps resets the PowerView RM interface One long beep When pressed simultaneously for about three seconds puts the interface in programming mode for installing new language program files Navigation The normal display on the PowerView is the monitoring screen shown below A snapshot of the UPS status is provided Pressing Esc multiple times will always allow return to this display CHEG 1003 Load 20 206Vin 208Vout 60Hz Runtime Ohr 27min From the monitoring screen press Esc to get to the Main Menu Control Logging Status Display gt Setup Diags Accessories Help The Main Menu provides access to each of the different function groups provided below Use the navigation keys to select the desired group Chapter 3 Menu Commands in this manual provides detailed descriptions of each functional group and its associated commands Menu Description Control Provides power control commands such as Load ON and Load OFF Status Displays information regarding load battery and power modules voltage and electrical current Setup Allows the user to customize the UPS functionality Accessories Allows monitoring of installed APC accessories if these are present Logging Provides ability to log system events Display Allows configuration of PowerView display settings Diagnostics Provides detailed information useful in troubleshooting the system Help Pr
10. control power flows to and from the UPS Turn UPS Output On Off Do Self Test Simulate Power Fail ure Graceful Reboot Graceful Turn Off Start Stop Runtime Cal ibration UPS into out of Bypass Controls the delivery of output power to the connected equipment Initiates a system of self testing and diagnostics An error message is displayed when a problem is detected Simulates a power failure return to test the server recognition of the failure event Initiates a signal for the server to shutdown After user defined Low Battery Duration plus Shutdown Delay the output power is switched off for the duration of the user defined Return Delay The output power is then switched on again See Setup Shutdown to set these time delays PowerChute software must be used on the server for proper shutdown Initiates a signal for the server to shut down After the user defined Low Battery Duration plus Shutdown Delay the output power is switched off Use Setup Shutdown to set these times PowerChute software must be used on the server for it to be properly shutdown Calculates an accurate battery runtime measurement Delivers load output power from battery source Discharges battery to 25 of capacity Battery capacity must be at 100 to execute this test Controls the bypass function When in bypass mode power is delivered directly from the utility source to load equipment CHAPTER 3 MENU COMMA
11. dicators and an audible alarm LOADON ONBATT gt BPC gt ms CD The tables below describe the status Sia J indicators and navigation keys Keys and Indicators Status Indicator Color Status LOAD ON Green The UPS is supplying power to the load and is operating in one of the following modes On Line On Battery Command Bypass or Maintenance ON BATT Yellow A mains power failure has occurred and the battery modules are supplying power to the load equipment BYPASS Yellow Power to the load is being supplied directly by the mains power source The UPS is removed from the circuit FAULT Red The UPS has detected an internal fault condition An alarm message will appear on the PowerView display Navigation Keys Name Sound Function i Up Short beep Moves the selection arrow upward l Down Short beep Moves the selection arrow downward ESC Escape Short beep Exits the current screen and returns to the previous screen Programming mode only When pressed until a short beep up to one second occurs it exits the programming mode CHAPTER 1 OVERVIEW Navigation Keys Name Sound Function Help Short beep Opens context sensitive help e Enter Short beep Opens the selected menu item or setting ESC el Escape Help Two short When pressed simultaneously for about one second Enter
12. e support Illustrations are representative Your configuration may be different from the models shown in this procedure To change the user interface language perform the following steps 1 Grab onto the door tabs Q gently pull forward and then up to remove the door 2 Remove the PowerView display by removing the screws and display from the frame 3 Remove the screws c securing the display bracket to the PowerView 4 Disconnect the UPS cable from the RJ 45 port on the PowerView 5 Connect the programming cable LE included between the PowerView and the UPS cable Attach the RJ 45 connector to the port on the rear of the PowerView Connect the female DB 9 connector of the programming cable to a serial port on the computer The computer must have internet access to download languages Attach the UPS cable to the female RJ 45 connector on the programming cable CHAPTER 2 BASIC COMMANDS Language Setting continued 10 11 12 13 14 15 Locate the language program file to be downloaded into the UPS See the APC website at http www apc com support and download the desired language Place the PowerView in programming mode simultaneously pressing the three keys on the right Esc Help and ENTER for approximately three seconds until the PowerView emits a long beep e The LCD will display the Programming screen e To leave the Programming screen before starting a file
13. er n redundancy modules that are set aside by the Fault Tolerance alarm threshold For example if there are four power modules installed and the fault tolerance alarm threshold is set to 1 this percentage of load uses only three power modules for the calculation See Setup Alarms to set the redundancy level Displays the measured input and output frequencies Battery Status Screen Displays battery module capacity runtime and status information Power Module Status Screen Displays power module capacity fault tolerance and status information Alarm Thresholds Displays the user defined alarm settings See Setup Alarms to set these alarm thresholds Status Screen Miscellaneous Displays the summary result Self Test Last System Transfer Operating Mode and status Status Screen of intelligence and redundant intelligence modules 12 CHAPTER 3 MENU COMMANDS Setup Menu The Setup Menu allows the user to customize the UPS functionality Sets the shutdown parameters in the event of a Shutdown a utility power failure Low Batt ery Sets the number of minutes an audible alarm 2 default 5 7 10 12 15 Dur ation sounds before the UPS shuts down due to battery a or 20 minutes exhaustion Shutdown Delay Sets the additional runtime for computer issuing 0 20 default 60 120 240 shutdown command if it needs additional time to 480 720 or 960 seconds shut itself down Return Delay Sets the del
14. nds isror aaa aa a aaa aa aiaa dahaa adain araa nia 9 Accessories Men Uninstall a care 9 Control Me ales 9 Display Menu o o MS as 10 Diagnostics Men ia 11 Help Ment ardid O ad etd orca ast ta eet ie eh eed sate Mea ado cite a ide emeate cast 11 Katote tiare MENU it AE E Dai 11 Logging Men Continente 12 Status Menu koniin ao i aa aE a E E E E a a oda Eaa aria bets 12 SETUP MENU iia ones a a p raa a a aa Doel A S E N EE aida 13 Setup Menu Continued nsira n 14 Chapter 4 TroubleShooting xiii ne 15 Chapter 5 Service ara Dr a ra cite a aa a a aaa aa aa a AAAA a aaa aE a EA AAA Aa Aaa A aaraa naa 21 APC Contact Numbers and Support 0 cccccececsecceceeeeeeeee cece cece se eeaeaeeeeeeescaaeaeeeeeeeseceaeaeeeeeeeseeeeeaeeesesensaeeeeeeeees 21 Battery Replacements Kits and Battery Recycling coooonococccccnnccccononocnconcnononononncnnnnnnnnnnnnnnnncnn cnn nn nn cn cnn nn nncnncnnns 21 CHAPTER 1 OVERVIEW Overview This manual provides an overview of operations for the Symmetra LX and Extended Run Cabinet including detailed explanations of monitoring control and configuration through the PowerView user interface Illustrations are representative Your unit and configuration including components and optional APC equipment may vary from those depicted in this document Manuals may be accessed through the APC Web site www apc com PowerView PowerView contains an alphanumeric display navigation keys status in
15. om the upper IM slot of External Battery Cabinets increased At least one external battery cabinet has been connected to the frame of External Battery Cabinets decreased At least one external battery cabinet has been disconnected from the UPS Redundancy Restored Power module redundancy loss occurred and was restored Either additional modules have been installed or the load has been reduced No corrective action is necessary 16 CHAPTER 4 TROUBLESHOOTING Condition PowerView Message Reason Corrective Action General Redundancy Restored Power module redundancy loss No corrective action Status occurred and was restored necessary continued Additional modules have been installed or the load has been reduced Load is No Longer above Alarm Threshold The load exceeded the load alarm threshold The situation has been corrected by a load decrease or threshold increase Min Runtime restored The system runtime dropped below the configured minimum runtime and was restored Additional battery modules were installed the existing battery modules were recharged the load was reduced or the threshold was raised Module Bad Battery Module A battery module has failed and Refer to module installation in Failure requires replacement the Symmetra LX Physical Installation Guide Bad Power Module A power module has failed and requires replacemen
16. ovides access to help information CHAPTER 2 BASIC COMMANDS Basic Commands Supply Power to the UPS This procedure supplies power to the Symmetra LX and does not supply power to the equipment connected to the UPS 1 Turn ON the AC utility power to the UPS 2 Switch ON the circuit breakers for all connected equipment If connected equipment is hardwired check that the output circuit breakers in the distribution panel are a turned ON If connected equipment is plugged into the UPS Q check that each UPS PDU output circuit breaker is switched ON 3 Switch ON the UPS input circuit breaker c 4 Turn ON the UPS system enable switch To start the UPS when there is no AC utility power present press and hold either of the cold start O buttons E for four seconds Note 220 230 240 V lt YO A AV 5 After initialization the monitoring screen appears providing a view of operating parameters Chg100 Load 000 220 Vin 000 Vout 60Hz Runtime 00hr 30min CHAPTER 2 BASIC COMMANDS Set the Correct Output Voltage 1 Press the Esc button until the Main Menu appears Use the up and down arrow keys to choose Setup and ENTER to select Control Logging Status Display gt Setup Diags Accessories Help 2 Use the arrow keys and ENTER to select Other Settings Alarms Shutdown Bypass Defaults Copy Output Freq gt Other
17. ow the steps below to directly connect the output power of the UPS to the branch circuit mains using the command bypass mode 1 Use Esc to view the Main Menu and select Control gt Control Logging Status Display Setup Diags Accessories Help 2 Scroll down and select the UPS into Bypass command gt UPS into Bypass Do Self Test Simulate Power Fail Graceful Reboot y 3 Confirm choice by selecting YES Confirm UPS into Bypass NO ABORT gt YES UPS into Bypass You will see the following message The green Load On and yellow Bypass status indicators will be on as well UPS IS BYPASSED Press any key Maintenance Bypass Maintenance Bypass is used to manually bypass the UPS and directly supply power to the load while the input circuit breaker is turned ON Follow the steps below to directly connect the output power of the UPS to the branch circuit mains using the maintenance bypass mode 1 Check that the input circuit breaker is turned ON 2 220 230 240 V CHAPTER 2 BASIC COMMANDS Language Setting The factory default language of the user interface is English You can change the language by downloading new firmware into the PowerView French German Italian and Spanish are available on the enclosed CD Visit the APC web site at http www apc com for multilingual product documentation and firmware languag
18. ress Esc until the Main Menu appears gt Control Logging Status Display Setup Diags Accessories Help 2 Scroll down and select the Turn UPS Output Off command Graceful Turn Off Start Runtime Cal gt Turn UPS Output Off 3 Confirm choice by selecting YES Confirm Turn UPS Off NO ABORT gt YES Turn UPS OFF You will hear some clicking sounds and see the following message UPS HAS BEEN COMMANDED TO TURN LOAD POWER OFF In approximately 90 seconds you will see the following message and the green Load On status indicator will be OFF The output is now off UPS LOAD IS OFF Press any key 4 To fully remove power from the UPS turn OFF the system enable switch and open the input circuit breaker Bypass Operation The bypass operation can be performed manually using the maintenance bypass switch or automatically using the PowerView to issue commands O e In either bypass mode the utility and circuit breakers must be turned on e The UPS must remain functional to stay in command bypass mode Put the UPS in maintenance Note bypass before turning off the system enable switch or removing both intelligence modules CHAPTER 2 BASIC COMMANDS Command Bypass Command Bypass requires utilization of the commands on the PowerView display This mode is used to bypass the UPS electronics and directly supply power to the load Foll
19. s because the maintenance bypass switch is in the on position No corrective action necessary 18 CHAPTER 4 TROUBLESHOOTING Condition PowerView Message Reason Corrective Action General Fault On Battery The UPS is in the on battery mode The battery modules are being discharged No corrective action is necessary Note The runtime duration is limited Prepare to shutdown the UPS and the load equipment or restore incoming voltage Need Bat Replacement One or more battery modules are in need of replacement Refer to module replacement procedure UPS Fault A fault has occurred in a power module The UPS Fault message always occurs when there is a bad power module failure message Call your contract service provider or APC Technical Support Shutdown or unable to transfer to Batt due to overload The UPS has shutdown because an overload occurred and bypass is not available Option 1 Reduce the load to eliminate overload Option 2 If possible add power modules to eliminate overload Option 3 Replace failed power modules to eliminate overload Note If bypass is not available because of a power failure wait for power to be restored If there is a utility problem have it corrected Load Shutdown from Bypass Input Freq Volts outside limits The UPS shut the load down while itwas on bypass due to the input power going out of the accep
20. t Intelligence Module is The intelligence module in the installed and failed lower IM slot has failed Redundant Intelligence The intelligence module in the Module is installed and upper IM slot has failed failed Threshold Load is above kVA alarm The load has exceeded the user Option 1 Reduce the load Alarm threshold specified load alarm threshold Option 2 Use the PowerView interface to raise the alarm threshold Redundancy has been lost The UPS no longer detects redundant power modules The power module s failed or the load increased Option 1 If possible install additional power modules Option 2 Decrease the load Option 3 Disable the redundancy alarm by setting redundancy to zero Startup gt Setup gt Alarms gt Redundancy gt Zero 17 CHAPTER 4 TROUBLESHOOTING continued redundancy alarm threshold The power module s failed or the load has increased Condition PowerView Message Reason Corrective Action Threshold Redundancy is below Actual power module redundancy Option 1 If possible install Alarm alarm threshold has fallen below the user specified additional power modules Option 2 Decrease the load Option 3 Use the PowerView to decrease the redundancy alarm threshold Startup gt Setup gt Alarms gt Redundancy Runtime is below alarm threshold The predicted runtime is lower than the user specified for the minimum runtime alarm threshold
21. table range Correct the input voltage problem Fault Battery Charger Failure The battery charger in one or more power module s failed Refer to module replacement procedure Fault Bypass Relay Malfunction The bypass relay has malfunctioned Call your contract service provider or APC Technical Support Fault Internal Temp exceeded normal limits The temperature of one or more battery modules is too hot Replace the overheated module Refer to module replacement procedure 19 CHAPTER 4 TROUBLESHOOTING Condition PowerView Message Reason Corrective Action General Fault continued Input circuit breaker tripped open The input circuit breaker on the UPS tripped open Input voltage is disconnected from the UPS Option 1 If this occurs in conjunction with an overload condition decrease the load and reset the breaker Option 2 If no overload condition exists reset the breaker If the breaker trips open again call contract service provider or APC Technical Support System level fan failed A cooling fan in the UPS frame failed Call contract service provider or APC Technical Support The Redundant Intelligence Module IM is in control The intelligence module in the lower IM slot has failed or is not installed The intelligence module in the upper IM slot is managing all activity Replace the intelligence module Refer
22. to module replacement procedure IIC inter module communications failed The communications between the MIM and at least one other module failed Call contract service provider or APC Technical Support 20 Service CHAPTER 5 SERVICE If the UPS requires service do not return it to the dealer Follow these steps 6 Review the problems discussed in the Troubleshooting chapter to eliminate common problems Verify that the circuit breakers have not tripped A tripped circuit breaker is the most common UPS problem If the problem persists call customer service or visit the APC Web site at http www apc com Note the model number of the UPS the serial number and the date purchased A technician will ask you to describe the problem and try to solve it over the phone if possible If this is not possible the technician will issue a Returned Material Authorization Number RMA If the UPS is under warranty repairs are free If not there is a repair charge Pack the UPS in its original packaging If the original packing is not available ask customer service about obtaining a new set Visit the APC web site for customer support telephone numbers Pack the UPS properly to avoid damage in transit Never use polystyrene beads for packaging Damage sustained in transit is not covered under warranty Mark the RMA on the outside of the package APC Contact Numbers and Support Visit the APC
23. transfer Step 6 press Esc until the beep about one second Start HyperTerminal or another terminal emulation program on the computer e Set the communication parameters to 8 bits no parity no flow control 1 stop bit and 19 200 bps e After establishing a connection use the Xmodem protocol to transfer the language program file from PowerView e When the file transfer is complete the PowerView will reset itself and display the Start Up screen in the new language If the file transfer fails PowerView will reset itself Retry the file transfer by repeating Step 6 and Step 7 Quit the terminal session Disconnect the programming cable on the PowerView RJ 45 port Connect the UPS cable to the PowerView RJ 45 port Install the display bracket to the rear of the PowerView by securing the two screws to the display With two hands grip the display and gently snap the tabs onto the frame Secure the PowerView display by tightening the two screws to the UPS frame CHAPTER 3 MENU COMMANDS Menu Commands The following sections describe the details of each command Commands are organized according to the menu hierarchy in the PowerView Accessories Menu The Accessories Menu allows you to monitor APC accessories if they are installed The PowerView must be connected to the computer interface port at the back of the UPS frame in order to monitor internal accessories Control Menu Use the Control Menu and its submenus to
24. voltage Display to UPS versions may not yield optimum results The output Copy command definition voltage selection should be reviewed by the user found in Powerview manual Copying between different product lines may leave 990 0142 page 11 some parameters in the target UPS set to factory defaults especially when copying from a product with lesser capability Self Test The UPS can automatically test itself at this user At Power On 7 days specified interval 14 days default or Disabled UPS ID Assigns an eight character text string to a system en Output Sets output voltage Selection depends upon US JAPAN system configuration 200 V 208 V 240 V INTERNATIONAL 220 V 230 V 240 V Vout Reporting Reports the most significant output voltage 14 Troubleshooting CHAPTER 4 TROUBLESHOOTING The PowerView reports various messages on the display including alarm status and changes in system configuration This section lists all the PowerView display messages the reason for the message and the appropriate corrective action Contact APC Technical Support Staff for assistance with complex UPS problems Refer to the APC Web site at http www apc com for a location near you Messages may occur simultaneously If this happens be sure to review all of the messages for a better understanding of the system condition Condition PowerView Message Reason Corrective Action Start Up Pwr modules changed
25. ys detailed battery module status and information Help Menu Displays detailed redundant intelligence module status and information To access PowerView online help screens press the Scroll Up and Scroll Down keys simultaneously to access context sensitive help Logging Menu The Logging Menu allows the user to customize the UPS log View Lo Logs the most recent 64 events Point to an entry and press ENTER for 9 more information on that event Records the total number of transfers to battery low battery faults and MS on battery runtime events Allows different types of events to be included or excluded from the log Configure Logging Event types include Power Events UPS Controls UPS Faults and User Activity Measure UPS Events 11 CHAPTER 3 MENU COMMANDS Logging Menu continued List Event Groups Lists the specific events in each group uPSContolevenis Control Events eres Activities uPSFautevents Fault Events Measure UPS Events Measure UPS Events Events Status Menu The Status Menu displays load battery power module voltage and electrical current information Vin Vout lout Displays input voltage s output voltage s and output current information load assuming Compares the current load to the total capacity of all power modules no redundancy load allowing for Compares the current load to the total capacity of all power modules except the pow