Contents
1. G O WW COO a a _ wr a na a O i oO N 1 Preface A member of the growing familv of rugged switches this switch addresses a need for a smaller switch This switch provides an affordable solution for rugged and outdoor environment transportation road side cabinet industrial floor shop multitenant dwellings or Fiber To The Home FTTH applications Capable of operating at temperature extremes of 34 C to 74 C this is the switch of choice for harsh environments constrained by space Plug and Play Solution The switch is a plug and play Fast Ethernet Switch in compact size It doesn t have any complicated software to set up This manual describes how to install and use the hardened compact Ethernet Switch This switch integrates full wire speed switching technology This switch brings the answer to complicated hardened networking environments To get the most out of this manual you should have an understanding of Ethernet networking concepts In this manual you will find e Features on the switch e Illustrative LED functions e Installation instructions e Specifications XPress Pro 92000 SW User Guide 4 2 Product Overview Hardened Compact Switch Package Contents When vou unpack the product package vou shall find the items listed below Please inspect the contents and report anv apparent damage or missing items immediatelv to vour authorized reseller This Switch User s Manual Ext
2. LANIRONIX XPress Pro SW 92000 User Guide Part Number 900 505 Revision A May 2007 Copyright amp Trademark 2005 Lantronix All rights reserved No part of the contents of this book may be transmitted or reproduced in any form or by any means without the written permission of Lantronix Printed in the United States of America Ethernet is a trademark of XEROX Corporation UNIX is a registered trademark of The Open Group Windows 95 Windows 98 Windows 2000 and Windows NT are trademarks of Microsoft Corp Netscape is a trademark of Netscape Communications Corporation Contacts Lantronix Corporate Headquarters 15353 Barranca Parkway Irvine CA 92618 USA Phone 949 453 3990 Fax 949 453 3995 Technical Support Online www lantronix com support Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact XPress Pro SW 92000 2 Contents 1 Preface Plug and Plav Solution 2 Product Overview Hardened Compact Switch Package Contents Product Highlights Front Panel Displav Physical Ports Connectivity 3 Installation Selecting a Site for the Switch DIN Rail Mounting Connecting to Power 12VDC DC Jack Redundant DC Terminal Block Power Inputs Alarms for Power and Port Failure Connecting to Your Network Cable Type amp Length Cabling A Specifications B Connector Pinouts XPress Pro SW 92000 N NO UO a oO A A O
3. andards IEC 61000 4 11 Environmental Test Compliance Vibration Resistance IEC 60068 2 6 Shock IEC 60068 2 27 Free Fall IEC 60068 2 32 XPress Pro 92000 SW User Guide 12 B Connector Pinouts Pin arrangement of RJ 45 connectors 12545678 Snag ta 4 The following table lists the pinout of 10 100BaseT TX ports Pin Regular Ports Uplink port Input Receive Data Output Transmit Data 2 ji nput Receive Data Output Transmit Data 3 Output Transmit Data jInput Receive Data Ne NG i NC SINC NC 6 Output Transmit Data Jinput Receive Data eee 8 INe NC XPress Pro 92000 SW User Guide 13
4. cifications Specification Hardened Compact Switch Applicable Standards Switching Method Forwarding Rate 10BaseT 100BaseT X FX Performance Cable 10BaseT 100BaselX 100BaseFX LED Indicators Dimensions Net Weight Power Operating Voltage amp Max Current Consumption Power Consumption Operating Temperature Storage Temperature Humidity Safety Emissions Description 10 100BaseT TX auto negotiating ports with RJ 45 connectors 100BaseFX fiber ports IEEE 802 3 10BaseT IEEE 802 3u 100BaseTX FX Store and Forward 10 20Mbps half full duplex 100 200Mbps half full duplex 148 80pps for 10Mbps 148 800pps for 100Mbps 2 pair UTP STP Cat 3 4 5 2 pair UTP STP Cat 5 Up to 100m 328ft MMF 50 or 62 5um SMF 9 or10um Per unit Power status PWR1 PWR2 Per port LNK ACT Green 10 100TX or 100FX 100 Yellow 10 100TX or 100FX W50mm x D110mm x H136mm Compact Size 0 8kg approx DC Jack 12VDC External AC DC required Terminal Block 10 48VDC 12VDC 0 99A 24VDC 0 55A 48VDC 0 39A 18 72W Max 34 C to 74 C 45 C to 93 C 10 95 non condensing UL CUL 60950 EN60950 IEC 60950 IEC 61000 6 2 FCC CE Standards ESD Standard IEC 61000 4 2 Radiated FRI Standards IEC 61000 4 3 Burst Standards IEC 61000 4 4 Surge Standards IEC 61000 4 5 Induced Conducted RFE Standards IEC 61000 4 6 Magnetic Field Standards IEC 61000 4 8 Voltage Dips St
5. e relay output is normal open position when there is no power to the switch Please do not connect any power source to this terminal to prevent the shortage to your power supply XPress Pro 92000 SW User Guide 10 3 Installation Connecting to Your Network Cable Type amp Length It is necessary to follow the cable specifications below when connecting the switch to your network Use appropriate cables that meet your speed and cabling requirements Port Speed Cable Max Speed Connector 10BaseT RJ 45 100BaseTX RJ 45 100BaseFX SC ST VF 45 MT RJ 100BaseFX SC Cabling Half Full Duplex Distance 10 20 Mbps 2 pair UTP STP Cat 3 4 5 100m 100 200 Mbps 2 pair UTP STP Cat 5 100 m 100 200 Mbps MMF 50 or 62 5um 2 km 100 200 Mbps SMF 9 or 10um 15 40 or 75 km 1 First ensure the power of the switch and end devices is turned off 2 Note Always ensure that the power is off before any installation 3 Prepare cable with corresponding connectors for each type of port in use 4 Note To connect two regular RJ 45 ports between switches or hubs you need a cross over cable 5 Consult the previous section for cabling requirements based on connectors and speed 6 Connect one end of the cable to the switch and the other end to a desired device 7 Once the connections between two end devices are made successfully turn on the power and the switch is operational XPress Pro 92000 SW User Guide 11 A Spe
6. ernal power adapter amp Power Cord Optional Product Highlights 70 0 XPress Pro 92000 SW User Guide 5 Meets NEMA TS2 Environmental requirements such as temperature shock and vibration for traffic control equipment Meets IEC61000 6 2 EMC Generic Standard Immunity for industrial environment Support 802 3 802 3u 802 3X Auto negotiation 10 100Mbps Full half duplex Auto MDI MDIX Support 2K MAC addresses Provides 96K bvtes memorv buffer 2 Product Overview Alarms for power and port failure bv relav output Operating voltage and Max current consumption 12VDC 0 99A 24VDC 0 55A 48VDC 0 39A Power consumption 18 72W Max Power Supply Redundant DC Terminal Block power inputs or 12VDC DC JACK with 124 240VAC external power supply Supports Din rail mounting installation Front Panel Display LED State Indication POWER PNR Stead Switch is properly connected to power and turned on PWR2 PNR FAULT Switch is not connected to power and is turned off Steady Steady Power failure occurred y Port failure occurred when port fault alarm dip switch is enabled FAULT Power failure is not occurred Red OWE Port failure is not occurred when port fault alarm dip switch is enabled 3 Port fault alarm dip switch is disabled 10 100TX or 100FX LNK ACT LNK stands for LINK ACT stands for ACTIVITY 100 Light solid yellow for a port transferring at 100Mbps Yellow The port is transf
7. erring at 10Mbps If this LED is dark XPress Pro 92000 SW User Guide 6 2 Product Overview Phvsical Ports This switch provides Eight 10 100BaseTX ports Eight 10 100BaseTX ports one 100BaseFX port Six 10 100BaseTX ports two 100BaseFX ports Four 10 100BaseTX ports four 100BaseFX ports Connectivity RJ 45 connectors SC ST VF 45 or MT RJ connector on 100BaseFX fiber port XPress Pro 92000 SW User Guide T 3 Installation This chapter gives step bv step instructions about how to install the switch Selecting a Site for the Switch As with anv electric device vou should place the switch where it will not be subjected to extreme temperatures humiditv or electromagnetic interference Specificallv the site vou select should meet the following requirements The ambient temperature should be between 34 to 74 degrees Celsius The relative humidity should be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards Make sure that the switch receives adequate ventilation Do not block the ventilation holes on each side of the switch The power outlet should be within 1 8 meters of the switch DIN Rail Mounting Fix the DIN rail attachment plate to the back panel of the switch Installation Place the switch on the DIN rail from above using the slot Push the front of the switch toward the mount
8. ing surface until it audibly snaps into place Removal Pull out the lower edge and then remove the switch from the DIN rail XPress Pro 92000 SW User Guide 3 Installation Connecting to Power Redundant DC Terminal Block Power Inputs or 12VDC DC Jack 12VDC DC Jack 1 Connect the supplied AC to DC power adapter to the receptacle on the topside of the switch 2 Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage DC12V 3A Redundant DC Terminal Block Power Inputs There are two pairs of power inputs can be used to power up this device You only need to have one power input connected to run the switch Connect the DC power cord to the plug able terminal block on the switch and then plug it into a standard DC outlet Disconnect the power cord if you want to shut down the switch XPress Pro 92000 SW User Guide 9 3 Installation PORT FAULT O O O 000 0 O J Alarms for Power and Port Failure 1 There are two pins on the terminal block are used for power failure detection It provides the normally closed output when the power source is active Use this as a dry contact application to send a signal for power failure detection Terminal Assignment PWRI Power Input 1 10 48 DC GND PWR2 Power Input 2 10 48 DC GND Earth Ground ON Enable Port Fault Alarm OFF Disable Port Fault Alarm PIN 10 BIHA Note Th
Download Pdf Manuals
Related Search
Related Contents
Samsung DV8700 7.4 cu. ft. Electric Top-Load Dryer (Stainless Platinum) User Manual Plaquette les légumes de la mer Cables Direct B6-502R networking cable Samsung WF7522S8C Washing Machine User Manual Pdf Targus Flexible Mobile Keyboard M3T-CC32R V.4.30 User`s Manual Jackson BP8J Instructions / Assembly Copyright © All rights reserved.
Failed to retrieve file