Home

Draper 130030 projection screen

image

Contents

1. should furnish appropriate hardware as required Recessed Installation Recess should permit access for removal of screen if necessary Screen may be mounted as in suspended or wall installation Angles may be used pro vided by others Electrical Connections Screen operates on 110 120V AC 60 Hz 220V AC 50 Hz current depend ing on model ordered Duty Cycle On 26 seconds off 3 minutes Junction box is located inside left endcap and cover plate is secured to endcap with two screws Junction box contains pigtail leads and grounding screws per wiring diagram on reverse Screen is shipped with internal wiring complete and control switch es fully boxed Wire connecting screen to switch es and switch es to power supply should be furnished by installer Connections should be made in accordance with attached wiring diagram and wiring should comply with National and local electrical codes All operating switches should be off before power is connected Do NOT wire motors in parallel Operation Before operating screen remove tape securing fabric and dowel to roller If viewing surface hangs out of case 8 or 9 20 23 cm tape has probably been broken by rough handling in shipment allowing surface to unwrap one turn about the roller Manually wrap fabric back around the roller without turning the roller itself 110 120V 220V Single Station Control 3 position up off down switch permits operation to be stopped at any point F
2. 5 i i 1 by installer I i 1 Black Single gang box by others tl i 1 Min 4 x 2 1 8 x 1 7 8 deep f a 3 shown More or less equally ate z Z 1 ran Location of key feasible 2 ere 1i A I operated on off 2 y installer ae witch if furnished ii 1 220v 50 Hz To 110V AC Line Low Voltage IR Remote or RF Remote LVC III Red to screen directional Brown to screen directional Yellow to 110 220V AC Hot White or Blue Common to screen amp 110 220V ac Neutral Internal Screen Wiring White Blue Common _Red 110 Black 220 Up Black 410 Broumn 220 Down A GreenYellow 220V MC1 See separate Serial Communication RS232 Instruction sheet for enabling RS232 with the MC1 Internal Screen Wiring Black to 110 220V AC Hot Motor Ground Green Ground Motor Ground White or Blue Common White Blue Common ieaiai PA Red to Screen directional l Red 110 Black 220 Up OO E E by ots EIU b j Blacket Sereen fection a e ae Ros C Eye Port for IR Eye RF Receiver or LED 1 110 220V ProgramLED Brown Hot to AC S Green 110V Wall Switch For more than one of amp n Line f Green Yellow Ground Eo E Green Yellow 220V
3. Installation Operating Instructions Baronet HW 110V and 220V Electric Projection Screen by Draper These Installation Operating Instructions are available in the official language of the country where you purchase the product Please contact your distributor to request a copy Vous pourriez demander les instructions d installation et d op ration traduises dans la langue officielle du pays ou vous achetez le produit Veuillez demander a votre distributeur Die Gebrauchsanweisung f r Installation und Konstruktion sind in der offiziellen Sprache des Landes indem Sie das Produkt gekauft haben vorhanden Fragen Sie die jeweilige Verkaufs Abteilung Caution Read instructions through completely before proceeding Follow instructions carefully Installation contrary to instructions invali dates warranty Screen should be accessible for complete removal should fabric be come damaged or should other service be required Screen should be installed level using a carpenter s level Nothing should be fastened to screen dowel or viewing surface Operating switch es packed separately in screen carton Do not dis card with packing material Screen operates on 110 120V AC 60 Hz or 220V AC 50 Hz current depending on model ordered NOTE Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment eG 0868 O Hanging Screen General When locating viewing surface and check
4. actory adjusted limit switches automatically stop screen when fully down or fully up 220V version is CE certified 110 120V 220V Multiple Station Control Switches are similar in ap pearance to 110V 220V Single Station Control Screen stops when switch is released and may be restarted in either direction Factory adjusted limit switches stop screen automatically when fully up or fully down 24V Control Three button up stop down switches stop at any point de sired operate in any sequence Factory adjusted limit switches automatically stop screen when fully up or fully down Key Operated Switching Two kinds of key operated switches are option ally available with this unit The key operated power supply switch controls power to the screen and switches When it is off the switches will not operate screen Key may be removed from the switch in either on or off position A three position key switch permits the screen to be operated directly by key In this case the screen s operator must always have a key RS232 Ethernet Serial communication and network communication optionally available with wall switches RF or IR remote Adjustments Screen has been factory set and should not normally require further adjustment However if you desire to change the up and down stopping positions proceed as follows Down limit switch Down stopping position can be adjusted by turning white knob with a screw dri
5. een left end of screen Internal Screen Wiring o White Common Single Station Control CE Approved Junction box at Internal Screen Wiring eftendiot screen Junction box at left end of screen Multiple Station Control Not CE Approved r White Common I Internal Screen Wiring 1 2 Black Down poe e Black Down Internal Screen Wiring Blue 220v Common ior p o Rod Up 1 p 4 2 Red Up Blue 220v Common Brown 220v Down roa tase Green Motor Ground Brown 220v Di r i l Green Motor Ground EET k rown 220v Down Black 220v Up TEE SOR hel i r Black 220v Up i Green Motor Ground ae f Toka l H p Green Motor Ground 1 roy a ie ee g I Control i A Single gang box by others i i i 1 i Blue 47 Min 4 x 2 1 8 x 1 7 8 deep fet Poh 4 i ia Sar qe 1 I Cap off with wire RedI 5 2 eens semis iy 5 2 Black a se Cap off with wire i ioi a oe nut amp tape 1 Dashed wiring 1 Red Blue nut and tape hy ly jp eee 4 4 by electrician pan 1 f aes fe ies i oN os ee ST 1 Red 9 Blue bd ileeenenseig Black Dashed wiring a K 774 E f 7 ocation of ke da i PES operated on ow i i by electrician PERRE Lo i Lf switch if furnished t E i o i es Control e i E 1 To 110V AC Li i Tii satai ois An 2 ng la Black 7 i j 1 f l 1 Red Blue Dashed wiring 3
6. ing clearance for screen s opera tion remember surface is centered in case Handle case carefully to protect its finish Regardless of mounting method screen should be positively and securely supported so that vibration or even abusive pulling on the viewing surface will not cause case to work loose or fall Installer must insure that fasteners used are of adequate strength and suitable for mounting surface chosen Suspended Installation Suspend screens from holes in top of endcaps as shown S hooks chains or cable and turnbuckles should be provided by installer S hooks should go through the front holes on the endcaps see drawing below and both ends of the S hooks should be crimped for additional safety Chains should be attached to beams or other structural members Turnbuckles should be adjusted so screen hangs level Back hole for wall mounting Hardware by others Top Hole for Mounting angle and hardware by others Suggested for recessed installations Hardware by others slot for passage of viewing surface if iN suspended above ceiling Example of suspension above ceiling Ceiling tile and grid by others 411 S Pearl St Spiceland IN 47385 USA I 1 765 987 79 www draperinc com I fax 1 765 987 1689 Copyright 2010 Draper Inc Form BaronetHW_Inst10 Printed in U S A suspended mounting Wall Installation Mount screen through holes in back of endcaps as shown Installer
7. these a splitter is required 1 t ior Motor Ground Location of key Fuse Low Voltage Wiring byothers 1 3 Button Wall Switch AC Wiring by electrician Si DOWN Black 7 operated on off i COM White 3 switch if furnished RS232 Data FROM Control System Ea 2 UP Red oe RS232 Data TO Control System tt Control Signal Ground amp Manual Switch Common rt m Aux Port for connecting additional LVC III Switches Manual Switch Down tot modules up to six total can be linked 24v DC Manual Switch Up tou connect from Aux to Eye si E71 Location of key i an d on off Eye Port for IR Eye For RF Receiver or LED 1 operate Mel E Wall Switch a Splitter and a Power Supply L Switch if furnished is required Plug RF Receiver or LED Wall r Switch and Power Supply into splitter then run cable from Splitter to MC1 Eye Port To AC Line 110 120V 3 Position Wall Switch 220V 3 Position Surface Mount Wall Switch ma 38mm 11 2 45mm 194 32mm 11 4 4 3 6 lead 11 8mm 4 2 86mm 78mm 38 31 16 Y www draperinc com DRADER 765 987 7999
8. ver or hex wrench Turning knob counterclockwise will allow viewing surface to run farther down Turning it clockwise will reduce the amount of exposed viewing surface Up limit switch Up stopping position can be adjusted by turning red knob with a screw driver or hex wrench through the small grommet Turning knob counterclockwise will allow surface to run farther into screen case Turning it clockwise will allow viewing surface to stop farther out of screen case Z CAUTION Be sure all switches are in off position before adjusting limit switches Always be prepared to shut screen off manually when new adjustment is being tested Screen may be severely damaged if viewing surface is allowed to run too far up or too far down Baronet HW 110 120V AC version is certified by c US Underwriters Laboratories Inc for the U S and Canada Baronet HW220V AC version is CE certified If you encounter any difficulties installing or servicing your Baronet HW screen call your dealer or contact Draper Inc Spiceland Indiana 1 765 987 7999 or fax 1 765 987 1689 Baronet HW by Draper Page 2 of 2 Case Dimensions 38 83 mm a 3 96 mm 83 mm ot Fabric width 534 146 mm a Viewing Surface Wiring Diagrams Please Note Do not wire motors in parallel Baronet HW 110V AC Single Station Control Multiple Station Control Baronet HW 220V AC CE Junction box at Junction box at left end of scr

Download Pdf Manuals

image

Related Search

Related Contents

キャプコンOA-W シリーズ CTG16用L型アングルホルダー  Measurement Specialties PCI-DIO24 User's Manual  ITW Devcon Material Safety Data Sheet  Audio Dock DMS-R1 RADIO USB GENERAL Toshiba recommends  取扱説明書[F-VXK90] (8.70 MB/PDF)  第10期 定時株主総会招集ご通知  契約書(案)[134KB pdfファイル]  User Manual - Support Cleaning Apparatus  Instalaciones de dosificación de hidracina DULCODOS  New Majestic CL-96  