Home
CyberPower CP1350EAVRLCD uninterruptible power supply (UPS)
Contents
1. CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION DO NOT USE WITH OR NEAR AGUARIUMS To reduce the risk of fire do not use with or near aguariums Condensation from the aguarium can come in contact with metal electrical contacts and cause the machine to short out CAUTION DO NOT USE WITH LASER PRINTERS The power demands of laser printers are too large for a UPS INSTALLING YOUR UPS SYSTEM UNPACKING The box should contain the following 1 PowerPanel Personal Edition software CD x1 2 USB cable A B type x1 3 Telephone communication cable x1 4 Power cord x2 5 user manual x1 6 UPS unit x1 OVERVIEW The CP1350EAVRLCD CP1500EAVRLCD provides automatic voltage regulation for inconsistent utility power The CP1350EAVRLCD CP1500EAVRLCD features 1215 Joules of surge protection and provides battery backup during power outages The CP1350EAVRLCD CP1500EAVRLCD ensures consistent power to your computer system and its included software will automatically save your open files and shutdown your computer system during a utility power loss HOW TO DETERMINE THE POWER REGUIREMENTS OF YOUR EGUIPMENT 1 Make sure that the total Volt Amp VA reguirements of your computer monitor and peripheral eguipment does not exceed 1350 VA 1500VA 2 Ensure that the eguipment plugged into the battery power supplied surge outlets does
2. CyberPower JOE Quality Value CP1350EAVRLCD CP1500EAVRLCD User s Manual K01 0000076 00 IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate CAUTION The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection DO NOT plug the UPS into an outlet that is not grounded If you need to de energize this eguipment turn off and unplug the UPS CAUTION DO NOT USE FOR MEDICAL OR LIFE SUPPORT EGUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect the operation or safety of any life support eguipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery There are no user serviceable parts inside except for the battery
3. ga stable 220 230 output voltage In the event of a complete power loss severe brownout or over voltage the UPS relies lel K STA on its internal battery to supply consistent 220 230 output INPUT OUTPUT ESTIMATE RUN TIME voltage The sa sa INPUT voltage meter can be used as a diagnostic tool to a l D 4 x identify poor guality input power Dal Ln bt Min OUTPUT voltage meter This meter measures the AC voltage that the UPS system is providing to the computer such as normal line mode AVR mode and battery back up mode Note The OUTPUT voltage meter shows the status of the battery back up outlets ESTIMATE RUN TIME This displays the run time estimate of the UPS with the current battery capacity and load NORMAL icon This icon appears when the UPS is working under normal GreenPower Bypass conditions BATTERY icon During a severe brownout or blackout this icon appears and an alarm sounds two short beeps followed by a pause to indicate the UPS is operating from its internal batteries During a prolonged brownout or blackout the alarm will sound continuously and the BATT CAPACITY meter shows one 20 capacity segment shaded to indicate the UPS s batteries are nearly out of power You should save files and turn off your equipment immediately AVR Automatic Voltage Regulator icon This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power This is a norm
4. not exceed the UPS unit s rated capacity 1350VA 810W for CP1350EAVRLCD 1500VA 2 900W for CP1500EAVRLCD If the rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down and the circuit breaker to trip 3 lf the power requirements of your equipment are listed in units other than Volt Amps VA convert Watts W or Amps A into VA by performing the calculations below Note The equation listed below only calculates the maximum amount of VA that the equipment can EN use not what is typically used by the equipment at given time Users should expect usage requirements to be approximately 60 of the maximum power requirements Watts W x 1 67 VA or Amps A x 230 VA Add the totals up for all pieces of equipment and multiply this total by 0 6 to calculate the approximate requirements There are many factors that can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s capacity BASIC OPERATION DESCRIPTION Power Switch 1 Used as the master on off switch for equipment connected to the battery power supplied outlets 2 Power On Indicator This LED is under the power switch It illuminates when the UPS outlets are providing power free of surges and spikes 3 LCD Module Display High resolution and intelligent LCD display shows all the UPS information with ico
5. saving money When the utility power is abnormal the UPS will operate under Battery or AVR Mode Under this condition Green Power UPS and a traditional UPS would operate about the 4 same On average utility power operates 88 of the time and the CyberPower GreenPower Technology will work in its money energy saving Bypass Mode BATTERY REPLACMENT CAUTION Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of personnel knowledgeable of batteries and their precautions CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present the risk of electrical shock Do not dispose of batteries in a fire as they may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 DO NOT lay tools or other metal parts on top of battery or any battery terminals 4 Wear rubber gloves and boots o Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT I
6. 40 C Physical Total of UPS outlets Maximum Dimensions LxWxH Weight kg 11 5kg Battery sealed Maintenance Free Lead Acid Battery Typical Recharge Time 8 hours Charging Current Max 0 7A User Replaceable Yes Status Indicators Indicators Audible Alarms Communication PowerPanel Personal Edition Software Management Self Test Auto Charger Auto Restart USB interface 230Vac 10 90 60Hz 1 8ms Typical On Utility Circuit Breaker On Battery Internal Current Limiting schuko x 6 Backup x 3 37 1 x 10 0 x 24 9cm 12 1kg 12V 8Ah x2 12V 8 5Ah x2 Power On LCD Display On Battery Low Battery Overload Windows Vista XP 2000 Server 2003 Linux CD a a m os m TROUBLESHOOTING Poem Possible Cause Soton O Full time surge protection outlets stop providing power to Circuit breaker has Turn the UPS off and unplug at least one piece of eguipment Wait 10 seconds reset the circuit equipment Circuit ear pe UR ab breaker by depressing the button and then turn button is projecting from the overload the UPS on side of the unit Battery not fully charged Recharge the battery by leaving the UPS plugged in The UPS does not perform expected runtime Battery is slightly worn out Contact CyberPower Systems about replacement batteries at service cyberpower eu com The on off switch is designed to prevent Turn the UPS off Wa
7. If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of eguipment from the battery power supplied outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on 8 Your UPS is eguipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically recharge 9 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 10 To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to ensure battery lite N CYBERPOWER GREENPOWER UPS TECHNOLOGY Our new UPS circuit is designed to save energy operating in GreenPower Bypass Mode A traditional UPS circuit with AVR provides normal output voltage through the Relay and AVR transformer The current travels first through the transformer conducting energy and generating heat This heat creates energy dissipation resulting in a Power Loss or consumption of utility power and money CyberPower s GreenPower Circuit Design is a solution to this Power Loss When the Utility Power is operating normally our Green Power UPS works in Bypass Mode Our GreenPower design conducts power only through the Relay and still provides normal output voltage Bypassing the transformer reduces power consumption thereby conserving energy and
8. N ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit BATTERY REPLACEMENT PROCEDURE 1 Turn off and unplug all connected equipment 2 Turn the UPS off and unplug it from the AC power source 3 Turn the UPS upside down 4 Remove the retaining screw 5 Slide the battery compartment cover front panel completely off of the unit 6 Remove the batteries from the compartment 7 Disconnect the battery wires from the batteries 8 Install the replacement batteries by connecting the red wire and black wire to the same color wires from the battery pack 9 Put the batteries back into the compartment 10 Slide back the battery compartment cover and tighten the retaining screw 11 Recharge the UPS for 8 16 hours to fully charge the battery REMINDER Batteries are consider HAZARDOUS WASTE and must be disposed of properly Almost any retailer that sells lead acid batteries collects used batteries for recycling as required by most state laws 5 DEFINITIONS FOR ILLUMINATED LCD INDICATORS INPUT voltage meter his meter measures the AC voltage that the UPS system is receiving from the utility wall outlet The LOAD CAPACITY y 9 y m O NE V UPS is designed through the use of automatic voltage regulation to continuously supply connected eguipment with zs na U N
9. al automatic operation of your UPS and no action is required on your part SILENT MODE icon This icon appears whenever the UPS is in silent mode The buzzer does not beep during silent mode until the battery reaches low capacity OVER LOAD icon This icon appears and an alarm sounds to indicate the battery supplied outlets are overloaded To clear the overload unplug some of your equipment from the battery supplied outlets until the icon turns off and the alarm stops FAULT icon This icon appears if there is a problem with the UPS Contact CyberPower Systems at service cyberpower eu com for further help and support BATT CAPACITY meter This meter displays the approximate charge level in 20 increments of the UPS s internal battery During a blackout or severe brownout the UPS switches to battery power the BATTERY icon appears and the charge level decreases LOAD CAPACITY meter This meter displays the approximate output load level in 20 increments of the UPS s battery outlets TECHNICAL SPECIFICATIONS CP1350EAVRLCD 1350VA 810W CP1500EAVRLCD 1500VA 900W Capacity VA Input Voltage Range 165VAC 265VAC Freguency Range 50 60Hz Auto Sensing AVR Function Boost 200 10V On Battery Output Voltage On Battery Output Frequency Transfer Time Overload Protection Surge Protection Lightning Surge Protection S OSE RJ11 RJ45 One In One Out Modem Protection Operating Temperature 32 F to 104 F 0 C to
10. it 10 seconds and then damage by rapidly turning turn the UPS on l it off and on UD a LEREN Contact CyberPower Systems about The battery is worn out replacement batteries at service cyberpower eu com Contact CyberPower Systems at service Acyberpower eu com Th Connect the USB cable to the UPS unit and an e USB cable is not M osnneced open serial port on the back of the computer You PowerPanel Personal Edition must use the cable that came with the unit is inactive The unit is not providing Shutdown your computer and turn the battery power UPS off Wait 10 seconds and turn the UPS back on This should reset the unit Additional troubleshooting information can be found at eu cyberpowersystems com Mechanical problem For more information visit eu cyberpowersystems com or contact CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 40 2348170 E MAIL sales cyberpower eu com Entire contents copyright 2004 CyberPower Systems B V All rights reserved Reproduction in whole or in part without permission is prohibited PowerPanel and PowerPanel Plus are trademarks of CyberPower Systems USA Inc ke 7 a F
11. mum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet The unit will charge in both the on and off position If you will use the software connect the USB cable to the USB port on the UPS 3 With the UPS unit off and unplugged connect the computer monitor and any externally powered data storage device Zip drive Jazz drive Tape drive etc into the battery power supplied outlets DO NOT plug a laser printer copier space heater vacuum paper shredder or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 4 To protect a fax telephone modem line or network cable connect a telephone cable or network cable from the wall jack outlet to the IN jack of the UPS Then connect a telephone cable or network cable from the OUT jack on the UPS to the modem computer telephone fax machine or network device 5 Plug the UPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service eguipment with large electrical demands e g air conditioner refrigerator copier etc Avoid using extension cords If used the extension cord must be grounded and rated for 15 amps 6 Depress the power switch to turn the unit on The power on indicator light will illuminate and the unit will beep 7
12. ns and messages For more information please check the Definitions for Illuminated LCD Indicators section LCD Display Toggle Selected Switch The switch can be used to select the LCD display contents including Input Voltage Output Voltage and Estimated Run Time The toggle frequency is set to one time per second Holding the switch for more than two seconds while running on battery will silence the buzzer USB Port to PC The USB port allow communication from the UPS to the computer The UPS communicates its status to the PowerPanel Personal Edition software when connected with a USB port Battery and Surge Protected Outlets The unit has three battery powered surge protected outlets for connected eguipment and ensures temporary uninterrupted operation of your eguipment during a power failure 7 Full Time Surge Protection Outlets The unit has three always on surge suppression outlets Communication Protection Ports Communication protection ports will protect any standard modem fax telephone line broadband network or Ethernet connection AC Input Connect the AC Power cord to a properly wired and grounded outlet Circuit Breaker Located on the side of the UPS the circuit breaker serves to provide overload and fault protection Hardware Installation Guide 1 Your new UPS may be used immediately upon receipt However recharging the battery for at least 8 hours is recommended to ensure that the battery s maxi
Download Pdf Manuals
Related Search
Related Contents
Panasonic SL-PR300 4 PW-AM500 取扱説明書 Vendo V-Max Manual Owner``s Manual Samsung M1777N Manual de Usuario Libretto di Istruzioni Instructions Manual Manuel d InCD Fichier la danse en JEU corrigé 22 02 2012 version complète Copyright © All rights reserved.
Failed to retrieve file