Home
StarTech.com 10/100 Mbps Fiber Ethernet Converter
Contents
1. 84 Or 90 e Input Rate Allows the user to select the input rate for this port from the following options Full 6 12 18 24 30 36 42 48 54 60 66 72 78 84 or 90 Media Port 2 100 FX e Port Mode Allows the user to set the port mode to Auto 10HD 10FD 100HD or 100FD e Flow Control Allows the user to enable or disable Flow Control If Flow Control is enabled the input and output rates are set in subsequent fields e Broadcast Storm Protection Allows the user to enable or disable Broadcast Storm Protection according to the parameters set in the Broadcast Limit field 8 Instruction Manual NOTE The Apply button in each sub menu page applies changes for that page but does not save them beyond the current session For any changes made the user must select Save from the main menu MAC Address Filter The MAC Address Filter sub menu contains fields for each of the two ports on the MMC110MMS that allows the user to enable MAC address filtering for specific addresses If one or more MAC addresses are en abled the filter process is turned on and only those MAC addresses that are enabled will be able to pass through the MMC110MMS All packets with MAC addresses that are not listed will be blocked NOTE The Apply button in each sub menu page applies changes for that page but does not save them beyond the current session For any changes made the user must select Save from the m
2. MC Link Status Changed System Reboot The user can choose Trap Host V1 or V2 and input IP addresses for four trap hosts 11 Instruction Manual NOTE The Apply button in each sub menu page applies changes for that page but does not save them beyond the current session For any changes made the user must select Save from the main menu Save The Save sub menu allows the user to confirm any changes that have been made in the monitoring system If changes are not confirmed with this function they will not be stored in the MMC110MMS Update Firmware The Update Firmware sub menu allows the user to download new firm ware for the MMC110MMS There are two fields in this sub menu TFTP Server IP Address Allows the user to enter the IP address of the server that the new firmware will be downloaded from e File Name Allows the user to enter the file name of the firmware to be installed Once the information in the fields is correct pressing the Upgrade button begins the installation Pressing the Reset button will clear the fields Reboot The Reboot sub menu allows the user to reboot the MMC110MMS Rebooting through this menu will require a new log in to the monitoring system after the MMC110MMS is successfully rebooted Telnet Management To begin managing the MMC110MMS through Telnet log in to the Media Converter by entering your password the username field is not required by the device The following command
3. D Status Indicators LED State Indication Steady Green Power On 1 PW FA Off Power Off Steady Orange Booting or failed Steady g Valid connection Flashing act 2 LK AT Off Transmitting receiving No connection Steady Full duplex mode 3 FD CL Flashing Collision occurred Off Half duplex mode Instruction Manual Technical Support StarTech com s lifetime technical support is an integral part of our commit ment to provide industry leading solutions If you ever need help with your product visit www startech com support and access our comprehensive selection of online tools documentation and downloads Warranty Information This product is backed by a one year warranty In addition StarTech com warrants its products against defects in materi als and workmanship for the periods noted following the initial date of purchase During this period the products may be returned for repair or replacement with equivalent products at our discretion The warranty covers parts and labor costs only StarTech com does not warrant its products from defects or damages arising from misuse abuse alteration or normal wear and tear Limitation of Liability In no event shall the liability of StarTech com Ltd and StarTech com USA LLP or their officers directors employees or agents for any damages whether direct or indirect special punitive incidental consequential or otherwise loss of profits loss of busi
4. Managed10 100 Mbps RJ45 to Multimode psijfiber Media Converter MMCHOMMST Instruction Manual C StarTech com Making hard to find easy FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide rea sonable protection against harmful interference in a residential installation This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio com munications However there is no guarantee that interference will not occur in a particu lar installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Use of Trademarks Registered Trademarks and other Protected Names and Symbols This manual may make reference to trademarks registered trademarks and other protected names and or symbols of third party compa
5. ain menu VLAN Configuration The VLAN Configuration sub menu has four main columns of fields e Active Allows the user to enable VLAN configuration VLAN ID Allows the user to enter a VLAN ID number VLAN Member Allows the user to configure which ports will be added 9 Instruction Manual to a VLAN group Users can choose TX Port FX Port or Mgmt Port If Mgmt Port is selected one of TX Port or FX Port must also be selected e Untag Allows the user to enable tagged or untagged VLAN for that VLAN group The MMC110MMS supports a maximum of one untagged VLAN NOTE The Apply button in each sub menu page applies changes for that page but does not save them beyond the current session For any changes made the user must select Save from the main menu SNMP Configuration The Simple Network Management Protocol SNMP Configuration sub menu provides four fields for users to edit GELIES e System Contact Allows the user to enter the name of the person in charge of the network system e System Location Allows the user to set the location of the network system e Get Community Allows the user to set the getcommunity string If the system only knows the get community string it can only read MIBs 10 Instruction Manual The default get community string for the media converter is public e Set Community Allows the user to
6. in menu of the monitoring system is persistently displayed on the left side of the screen after log in Options can be selected with the mouse cursor The sub menus available from the main menu are System Change IP Configuration MC Status MC Control MAC Address Filter VLAN Configuration SNMP Configuration Alarm Save Update Firmware Reboot NOTE The Apply button on each sub menu page applies changes for that page but does not save them beyond the current session For any changes made the user must select Save from the main menu System Change Menu The System Change menu contains the following fields that users can edit Instruction Manual e Device Name A device name for the MMC110MMS can be set by the user in this field e New Password A new password for the monitoring system can be set in this field Setting a new password in this field requires entering the previous password in the Old Password field e Old Password The password that was previously being used to log in to the monitoring system must be entered here when a new pass word is being applied If the password is being changed from the default blank field this field should be left blank The System Change menu also contains two fields that display reference information e Version The version of software currently being used MAC Address The MAC address assigned to the MMC110MMS NOTE The Apply button in each sub menu page applies cha
7. ness or any pecuniary loss arising out of or related to the use of the product exceed the actual price paid for the product Some states do not allow the exclusion or limitation of incidental or consequential damages If such laws apply the limitations or exclusions contained in this statement may not apply to you StarTech com Mla Making hard to find easy StarTech com has been making hard to find easy since 1985 providing high quality solutions to a diverse IT and A V customer base that spans many channels including government education and industrial facilities to name just a few We offer an unmatched selection of computer parts cables A V products KVM and Serv er Management solutions serving a worldwide market through our locations in the United States Canada the United Kingdom and Taiwan Visit www startech com today for complete information about all our products and to access exclusive interactive tools such as the Cable Finder Parts Finder and the KVM Reference Guide
8. nges for that page but does not save them beyond the current session For any changes made the user must select Save from the main menu IP Configuration The IP Configuration sub menu contains the following fields that can be set by the user Instruction Manual e DHCP Allows the user to set DHCP to Enable or Disable If DHCP is enabled the MMC110MMS will set its IP address according to a DHCP server This IP will replace any other IP address that the Media Converter had been using e IP Address Allows the user to set an IP address for the MMC 110MMS The default address is 192 168 1 10 e Netmask Allows the user to set the Netmask or subnet mask The default is 255 255 255 0 e Default Gateway Allows the user to set the gateway address of the MMC110MMS in the network The default is 192 168 1 254 NOTE The Apply button in each sub menu page applies changes for that page but does not save them beyond the current session For any changes made the user must select Save from the main menu MC Status The Media Converter Status sub menu contains the following reference fields for a user to view e Operation Status Normal Hardware Fault or Software Fault 6 Instruction Manual Media Port Status Individual status reports for both the 10 100 TX port and 100 FX port in these categories Link Status Receive Count CRC Count Drop Count Collision Count NOTE The Apply but
9. nies not related in any way to StarTech com Where they occur these references are for illustrative purposes only and do not represent an endorsement of a product or service by StarTech com or an en dorsement of the product s to which this manual applies by the third party company in question Regardless of any direct acknowledgement elsewhere in the body of this doc ument StarTech com hereby acknowledges that all trademarks registered trademarks service marks and other protected names and or symbols contained in this manual and related documents are the property of their respective holders Table of Contents Ji de e TO e TEE 1 VVC ATION EE Connecting to Power Configuration and Management ccsssseseseeeeee 3 Web Browser Configuration cscceeseeeseseeseeneerseeneereeenes 3 Logging Out Of The Monitoring System c ceeeeeeeees 3 System Change MeNU t ic2 iver eelisesteneetetecitaaessieseseeceraitived 4 IP GOmMPG UAL TE 5 le TEE MC Control MAC Address Elter 9 VU Re ee e DE 9 SNMP ContiQuration eesin se lse derved id ses nere 10 Telnet Management Specifications reel 14 LED Status Indicators scenerne 15 Technical Support 22455 ERE 16 Warranty Information screen 16 Instruction Manual Introduction Thank you for purchasing a StarTech com Managed 10 100 Mbps RJ45 to Multimode ST Fiber Media Converter A perfect solution for large high speed networks that require expansion of fa
10. r Connect the AC to DC power adapter to the receptacle on the rear panel of the MMC110MMS then insert the corresponding plug into a standard AC outlet with a voltage range from 100 to 240VAC PLEASE NOTE A grounding strap should be worn while handling the Media Converter as well as when plugging and unplugging the TX port connector Instruction Manual Configuration and Management The MMC110MMST Media Converter can be configured and managed through SNMP Web browsers and Telnet as outlined in the following sections Web Browser Configuration Logging Into The Monitoring System The MMC110MMS is accessible through a web browser such as Internet Explorer To access the MMC110MMS monitoring system enter the de fault IP address of the MMC110MMS 192 168 1 10 into your browser s address bar By default the username and password to access the monitoring system are set to blank fields The password can be changed once the user has logged in the username is not required to log into the monitoring system and can be left blank Logging Out Of The Monitoring System The MMC110MMS monitoring system does not include a separate log out function The system automatically ends a management session when the browser software is closed Logging off by closing the browser and then logging in again may be required if changes made during a management session do not seem to take effect on screen Instruction Manual Main Menu The ma
11. s are available from the Main Screen e Get Command Usage get g lt OPTION gt 12 Instruction Manual mc status MS eee Get central MC status mc config MC wee Get central MC configuration netconf nc ww Get networking configuration SyYSinto E Get system information e Set Command Usage set s lt OPTION gt mc mode mm Mu Set central MC operation mode port mode pm Set central MC port mode port rate pr ee Set central MC port rate netconf nc Get networking configuration sysadmin Sa wee Set system administrator Instruction Manual Specifications Applicable Standards Ports Speed Performance Port LED Indicators Dimensions Weight Power Input Power Consumption Operating Temperature Storage Temperature Humidity Emissions IEEE802 3 10Base T IEEE802 3u 100Base TX 100Base FX 1 port 10 100Base TX with RJ 45 connector 1 port 100Base FX with fiber optic connector 100Base TX 200Mbps full duplex 100Mbps half duplex 10Base T 20Mbps full duplex 10Mbps half duplex 148 810pps forwarding rate for 100Mbps 14 880pps forwarding rate for 10Mbps Unit PW FA TX LK AT FD CL FX LK AT 80mm W x 145mm D x 20mm H 3 15 W x 5 71 D x 0 79 H 150g 0 33lb 0 27A 12VDC 3 24W Max 0 C 45 C 32 F 113 F 10 C 70 C 14 F 158 F 5 95 non condensing FCC Part 15 Class A CE Mark Class A Instruction Manual LE
12. set the setcommunity string If the SNMP Network management station only knows the set community string it can read and write to the MIBs The default set community string for the media converter is public NOTE The Apply button in each sub menu page applies changes for that page but does not save them beyond the current session For any changes made the user must select Save from the main menu Alarm The Alarm sub menu allows a user to enable or disable alarms for the following scenarios MC Fault Alarm will be triggered if the internal communication of the Media Converter fails e MC Link Status Changed Alarm will be triggered if the status of the link between two Media Converters changes e System Reboot Alarm will sound if the MMC110MMS reboots The Alarm sub menu allows the user to configure email alerts when an alarm is triggered Options available here include e Alarm by SMTP Allows the user to enable or disable email alerts e SMTP Server Address Allows the user to set the IP address of the server that will send the email alert Mail From Allows the user to set the From email address e Mail To Allows the user to set the email address that the email alerts will be sent to e User Name Allows the user to enter the username of the SMTP server account Password Allows the user to enter the password of the SMTP server account The Alarm sub menu also allows the user to set SNMP traps for
13. st Ethernet networks over long distances the MMC110MMST acts as a standalone device allowing for one channel media conversion between 10 100 Base TX and 100 Base FX network segments Featuring fully integrated managed software and support for Telnet SNMP v1 and v2 and Web Browser management the MMC110MMST ensures broad compatibility and maximum installation and configuration convenience Features e 10 100Mbps Full Half duplex Auto Negotiation Auto MDI MDIX e 1024 MAC addresses e 256Kbps of buffer memory e Compact design and weight makes it portable and unobtrusive to carry e Led Indicators that detect Power Link Activity Duplex mode and Col lision status e Provides MAC address filtering e Supports Telnet SNMP V1 amp V2 and Web Browser Management Package Contents e 1 x Instruction Manual e 1x MMC110MMST Instruction Manual Installation For optimal performance and safety ensure that the MMC110MMS is installed in an area that meets the following specifications e A temperature between 0 to 45 Celsius 32 and 113 Fahrenheit e Relative Humidity RH less than 95 non condensing e Surrounding electrical devices that do not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength e Adequate ventilation with the ventilation holes on each side of the equipment being clear of obstruction e Power outlet within 1 8 meters 5 9 of the product Connecting to Powe
14. ton in each sub menu page applies changes for that page but does not save them beyond the current session For any changes made the user must select Save from the main menu MC Control The Media Converter Control sub menu contains three main categories of fields Tink BE reneo E Wears e MC Options e Forwarding Mode Can be set to either Store amp For ward or Repeater mode e Broadcast Limit Allows the user to set a percent 7 Instruction Manual age limit on how much bandwidth is allocated for broadcast traffic passing through the MMC110MMS If Broadcast Storm Protection is enabled on either or both of the ports the Broadcast Limit percentage will be applied on the data packets using that port Media Port 1 10 100 TX e Port Mode Allows the user to set the port mode to Auto 10 Half Duplex HD 10 Full Duplex FD 100HD or 100FD e Flow Control Allows the user to enable or disable Flow Control If Flow Control is enabled the input and output rates are set in subsequent fields e Broadcast Storm Protection Allows the user to enable or disable Broadcast Storm Protection according to the parameters set in the Broadcast Limit field e Output Rate Allows the user to select the output rate for this port from the following options Full 6 12 18 24 30 36 42 48 54 60 66 72 78
Download Pdf Manuals
Related Search
Related Contents
Panasonic KX-DT346X telephone Pwn Plug Release 1.1 User Manual ASUS BM1845 SW7753 User's Manual Les Additifs alimentaires : ES1210 Installation and Operation Manual Welcome to the Hansoft Trial Altus Digital Recorder - KMI Support WIKI AVG 8.0 Desktop and Server Protection (User Manual) Copyright © All rights reserved.