Emerson Liebert MPH, Managed Rack PDU

image

Contents

1. 10 Figure 11 Temperature humidity sensor mounting 11 Figure 12 Model number nomenclature 14 TABLES Table 1 Liebert MPH Model numbers and specifications 13 Table 2 Liebert MPH dimensions 14 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions Read all safety installation and operating instructions before installing Liebert MPH power distribution units Adhere to all warnings on the unit and in this manual Follow all operating and user instructions Individuals without previous training can install and operate this equipment The Liebert MPH is designed for data processing equipment The Liebert MPH is not intended for use with life support or other designated critical devices If uncertain about its application con sult your local dealer or Emerson representative Maximum load must not exceed that shown on the Liebert MPH rating label Operate the Liebert MPH in an indoor environment only in an ambient temperature range of 32 F to 131 F 0 C to 55 C Install it in a clean environment free of conductive contaminants moisture flammable liquids gases and corrosive substances Liebert MPH power distribution units have no user serviceable parts Under no circumstances attempt to gain internal access due to the risk of
2. Installation in Knurr Miracel Rack Vertical Zero U Mount 2 0 INSTALLATION IN KNURR MIRACEL RACK VERTICAL ZERO U MOUNT 2 1 2 2 A Liebert MPH can be installed in a Knurr Miracel rack on the frame members using field supplied Knurr hardware The unit can be installed on the face or the side of frame members Mounting Hardware and Tools Required Factory Supplied Brackets 2 Screws 6 32 x 1 4 8 Field Supplied Spring nuts supplied with Knurr rack Tool less fasteners supplied with Knurr rack Phillips screwdriver Install a Liebert MPH in a Knurr Miracel Rack Determine where in the Knurr Miracel the Liebert MPH will be installed and follow the applicable instructions below Installation requires attaching two brackets to the Liebert MPH inserting four spring nuts into the rack and using the brackets to attach the Liebert MPH to the rack Refer to Figures 2 3 and 4 Refer to Table 2 for the dimensions of the Liebert MPH The bracket is intended for attaching the Liebert MPH to the face of a frame member 1 Use four of the 6 32 screws to attach a bracket to each end of the Liebert MPH The supplied brackets have four holes that match holes on each end of the Liebert MPH If mounting on horizontal frame members attach the brackets in line as shown in the left side of Figure 2 If mounting on an upright frame member attach the brackets at a right angle to the Liebert MPH as shown in the r
3. the Liebert RPC which permits managing the Liebert MPH over a secure Web page and SNMP based network management system The Liebert RPC permits interconnecting multiple Liebert MPH units and connecting Liebert MPH with other units for monitoring and management A Liebert MPH can be monitored locally with an RPC BDM an optional display module that con nects directly to the communication card The monitoring unit can be handheld mounted in or on the rack or mounted on a nearby wall Multiple Liebert MPHs can be centrally managed with Liebert Nform which adds group based receptacle management Figure 1 Liebert MPH units horizontal 10 rack mount and vertical zero U mount Rack Mount Liebert MPH Vertical Mount Liebert MPH Introduction 1 1 General Characteristics Input current 16 to 82 Single phase and three phase power input Input voltages 120VAC 120 208VAC 208VAC 230VAC 230 400VAC 240VAC Line to Line and Line to Neutral Output Receptacles NEMA and IEC Input connection by hard wired cords 10 feet 3m long Input power cord plugs L5 20P L5 30P L6 20P L6 30P L21 30P IEC C20 IEC309 3 wire 82 IEC309 5 wire 32A For details refer to 6 0 Specifications Refer to Table 2 for the dimensions North American Input Output Systems 120VAC Single Phase Input Vertical Mount L5 20P or L5 30P plug connection 10 ft 3m input power cord 20 or 30A 5 20R T blade recepta cles
4. 27 outlets 68 25 in 1735mm long 120VAC Single Phase Input Output Rack Mount L5 20P or L5 30P plug connection 10 ft 3m input power cord 20 or 30A 5 20R T blade recepta cles 9 outlets 1U tall 200 240VAC Single Phase Input Output Vertical Mount L6 20P or L6 30P plug connection 10 ft 3m input power cord 20 or 30A 27 IEC C13 or 21 IEC C13 plus 6 IEC C19 68 25 in 1735mm long 200 240VAC Single Phase Input Output Rack Mount L6 20P or L6 30P plug connection 10 ft 3m input power cord 20 or 30 IEC C13 receptacles 9 outlets 1U tall 120 208VAC Three Phase Input 208 amp 120VAC Output Vertical Mount L21 30P or L15 30P plug connection 10 ft 3m input power cord 20 or 30A 27 IEC C13 or 21 IEC C13 plus 6 IEC C19 or 21 IEC C13 plus 6 5 20R receptacles 27 outlets 68 25 in 1735mm long European Input Output Systems 230VAC Single Phase Input Output Vertical Mount IEC C20 or IEC 309 plug connection 3m 10 ft input power cord 16 or 32A 27 IEC C13 or 21 IEC C13 plus 6 IEC C19 68 25 in 1735mm long 230VAC Single Phase Input Output Rack Mount IEC C20 or IEC 309 plug connection 3m 10 ft input power cord 16 or 32A IEC C13 receptacles 9 outlets 1U tall 400VAC Three Phase Input 230VAC Output Vertical Mount IEC 309 plug connection 3m 10 ft input power cord 20 or 30A 27 IEC C13 or 21 IEC C13 plus 6 IEC C19 receptacles 27 outlets 1735mm 68 25 in long
5. 3 6 1 IEC C20 21 C 13 amp 6 C 19 Vertical MPH ECRO9NXXQ30 230 32 32 7 3 1 IEC 309 9 IEC C13 Rack mount MPH ECRO9NXXO30 230 16 16 3 6 1 IEC C20 9 IEC C13 Rack mount 13 Specifications Table 2 Liebert MPH dimensions Vertical Mount W x D x H in mm 1 97 x 3 13 x 68 1 50 x 80 x 1730 Rack Mount W x D x H in mm 17 25 x 7 0 x 1 73 438 x 178 x 44 mm Figure 12 Model number nomenclature MPH N C R 09 AX MODEL MPH TYPE NUMBER OF B Basic Monitor RECEPTACLES Only 09 9 Receptacles C Controlled 27 27 Receptacles Outlets REGION MOUNTING N North America V Vertical Mounting E Europe Zero U R Rack Horizontal Mounting EXAMPLE MPH NCRO9AXC30 Liebert MPH Controlled Outlets Rack Mounting 9 Receptacles 5 20R 00 Receptacle Type no second set of receptacles L5 20P Plug 3m Input Power Cord UNASSIGNED RECEPTACLE TYPE Two Sets Possible A 5 20R 00 N IEC C13 O IEC C19 C 30 INPUT CORD LENGTH two digits INPUT PLUG TYPE C L5 20P D L5 30P E L6 20P F L6 30P H L21 30P J L15 30 K to M TBD O IEC C20 Q IEC 309 32A 3W R IEC 309 32A 5W 14 Specifications 6 1 Agency Approvals 120V and 208V Single Phase and Three Phase Units UL 60950 1 Information Technology Equipment CAN CSA C22 2 No 60950 1 03 Information Technology Equipment FCC Title 47 Part 15 Subpart
6. A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference that the user must correct including the expense of all corrective modifications Introduction 1 0 INTRODUCTION The Liebert MPH Series is a managed single phase or three phase power distribution unit that offers monitoring only or monitoring along with receptacle control Liebert MPH units are available for mounting in either vertical zero U configuration and rack mount ing in standard 19 enclosures Vertical mount units may have as many as 27 receptacles The hori zontal mount units have up to nine receptacles The output receptacles support equipment requiring connection with NEMA 5 20R IEC60320 C13 and IEC60320 C19 plugs A Liebert MPH with single phase input has a capacity up to 7 4kW 230VAC 32A or 3 6kW 120VAC 30A Three phase input systems have a capacity up to 22 1kW 230 400VAC 32A or 10 7kW 120 208VAC 30A For further details refer to 6 0 Specifications Remote monitoring is enabled by the included communication card
7. B for Class B operation as defined by ANSI Standard C63 4 ROHS Compliant ISTA Procedure 1A and 2A 230V and 400V Three Phase Units CE Markings Directive 93 68EEC according to the Low Voltage Directive LVD CE Markings Directive 73 23 EEC Electromagnetic Compatibility EMC Directive 89 336 EEC European Directive 2002 95 EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment ROHS and WEEE Compliant EC 61709 ISTA Procedure 1 A and 2A 6 2 Product Warranty Registration To register for warranty protection visit the Service and Support section of the Liebert Web site at www liebert com Click on Product Registration and fill out the form 15 Specifications NOTES 16 Specifications 17 Specifications 18 Ensuring The High Availability Of Mission Critical Data And Applications Emerson Network Power the global leader in enabling business critical Technical Support Service continuity ensures network resiliency and adaptability through Web Site a family of technologies including Liebert power and cooling www liebert com technologies that protect and support business critical systems Monitoring Liebert solutions employ an adaptive architecture that responds liebert monitoring emerson com 800 222 5877 Outside North America 00800 1155 4499 Single Phase UPS amp Server Cabinets liebert upstech emerson com 800 222 5877 Outside
8. North America 00800 1155 4499 Three Phase UPS amp Power Systems 800 543 2378 Outside North America 614 841 6598 Environmental Systems 800 543 2778 Outside the United States 614 888 0246 Locations United States 1050 Dearborn Drive P O Box 29186 Columbus OH 43229 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco PD Italy to changes in criticality density and capacity Enterprises benefit from greater IT system availability operational flexibility and reduced capital equipment and operating costs 39 049 9719111 While every precaution has been taken to ensure the accuracy Fax 39 049 5841 257 and completeness of this literature Liebert Corporation assumes no Asia responsibility and disclaims all liability for damages resulting from use of ores this information or for any errors or omissions 29 F The Orient Square Building 2009 Liebert Corporation F Ortigas Jr Road Ortigas Center All rights reserved throughout the world Specifications subject to change Pasig City 1605 without notice Philippines Liebert is a registered trademark of Liebert Corporation 63 2 687 6615 All names referred to are trademarks or registered trademarks of their respective owners Fax 63 2 730 9572 SL 20827_REVO1_08 09 Emerson Network Power The global leader in enabling Business Critical Continuity EmersonNetworkPower com BE AC Power EI Embedded Computing I Outside Plant Racks amp
9. electric shock or burn Do not continue to use the Liebert MPH if the LED panel or monitoring interface indicators are not in accordance with these operating instructions Refer all faults to your local dealer Emerson representative or Emerson Network Power Applications Engineering Never block or insert any object into the Liebert MPH DO NOT CONNECT equipment that could overload the Liebert MPH Refer to 6 0 Specifications to determine the electrical ratings and specifications of your Liebert MPH It is imperative that the power supply and connections match the specifications of the unit being installed WARNING Opening or removing the cover of a Liebert MPH may expose you to lethal voltages within the power distribution unit Observe all cautions and warnings in this manual Failure to do so may result in serious injury or death Liebert MPH units contain no user serviceable parts For service contact Emerson Network Power Applications Engineering or your local Emerson representative Do not attempt to service this product yourself Never work alone CAUTION Connecting your Liebert MPH and rack equipment to a power supply with an incorrect rating in voltage amperes or phase may damage the connected equipment and your Liebert MPH If you have questions about the power supply connections contact Emerson Network Power Applications Engineering or your local Emerson representative CAUTION Shut down and unplug all e
10. power plate 2 Reposition so that power cord enters from front 3 Reinstall the screws and tighten them Figure 5 Reposition input power cord auedury oz IRIS ANIMO puwa Input Power Plate Screws Input Power Plate Repositioned for Different Cable Angle Installation in Knurr Miracel Rack Horizontal Rack Mount 3 0 INSTALLATION IN KNURR MIRACEL RACK HORIZONTAL RACK MOUNT A Liebert MPH can be installed in a Knurr Miracel rack in only 1U of equipment space using field supplied Knurr hardware 3 1 Mounting Hardware and Tools Required Factory Supplied L shaped bracket 2 Screws 6 32 x 1 4 8 Field Supplied Phillips screwdriver 3 2 Install a Liebert MPH in a Knurr Miracel Rack 3 2 1 Attach Mounting Brackets to the Liebert MPH Before attaching the horizontal mount brackets to the Liebert MPH determine whether to attach the brackets to the front edge or rear edge of the unit This will depend in part on whether the Liebert MPH would be best placed in the front of the rack or in the rear for routing power and communication wires Bracket location also determines whether the Liebert MPH display is viewed from the front or rear of the rack When mounting the Liebert MPH position the unit for ease of access and clearance Refer to Table 2 for the dimensions of the Liebert MPH To attach the brackets 1 Hold one mounting bracket against the side of the Liebert MPH making sure that the e
11. 30 208 240 20 16 3 3 1 NEMA L6 20 27 IEC C13 Vertical MPH NBV27NOXH30 208 120 30 24 8 6 3 NEMA L21 30 21 IEC C13 amp 6 IEC C19 Vertical MPH NBV27NOXF30 208 240 30 24 4 9 1 NEMA L6 30 21 IEC C13 amp 6 IEC C19 Vertical MPH NBV27AXXH30 208 120 30 24 8 6 3 NEMA L21 30 27 NEMA 5 20R T Slot Vertical MPH NBV27AXXD30 120 30 24 2 8 1 NEMA L5 30 27 NEMA 5 20R T Slot Vertical MPH NBV27AXXC30 120 20 16 1 9 1 NEMA L5 20 27 NEMA 5 20R T Slot Vertical MPH NBV27ANXH30 208 120 30 24 8 6 3 NEMA 121 30 21 IEC C13 amp 6 NEMA 5 20R T Slot Vertical MPH NBRO9NXXF30 208 240 30 24 4 9 1 NEMA L6 30 9 IEC C13 Rack mount MPH NBRO9NXXE30 208 240 20 16 3 3 1 NEMA L6 20 9 IEC C13 Rack mount MPH NBRO9AXXD30 120 30 24 2 8 1 NEMA L5 30 9 NEMA 5 20R T Slot Rack mount MPH NBRO9AXXC30 120 20 16 1 9 1 NEMA L5 20 9 NEMA 5 20R T Slot Rack mount European Applications MPH EBV27NXXR30 400 230 32 32 12 8 3 IEC 309 27 IEC C13 Vertical MPH EBV27NXXQ30 230 32 32 7 3 1 IEC 309 27 IEC C13 Vertical MPH EBV27NXX030 230 16 16 3 6 1 IEC C20 27 IEC C13 Vertical MPH EBV27NOXR30 400 230 32 32 12 8 3 IEC 309 21 C 13 amp 6 C 19 Vertical MPH EBV27NOXQ30 230 32 32 7 3 1 IEC 309 21 C 13 amp 6 C 19 Vertical MPH EBV27NOXO30 230 16 16 3 6 1 IEC C20 21 C 13 amp 6 C 19 Vertical MPH EBRO9NXXQ30 230 32 32 7 3 1 IEC 309 9 IEC C13 Rack mount MPH EBRO9NXXO30 230 16 16 3 6 1 IEC C20 9 IEC C13 Rack mount Monitoring Level Contr
12. Hi AC Power For Business Critical Continuity Liebert MPH User Manual North American amp European Applications 4 P 9 EMERSON Network Power TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS lesen hh 1 1 0 INTRODUCTION Ga adr See AA IA 3 1 1 General Characteristics ss ii x sale ti ead eae Gis la wa da 4 1 1 1 North American Input Output Systems 4 1 1 2 European Input Output Systems 4 2 0 INSTALLATION IN KNURR MIRACEL RACK VERTICAL ZERO U MOUNT 5 2 1 Mounting Hardware and Tools Required 5 2 2 Install a Liebert MPH in a Knurr Miracel Rack 5 2 3 Reposition Input Power Cord oss scena nu za anna u 7 3 0 INSTALLATION IN KNURR MIRACEL RACK HORIZONTAL RACK MOUNT 8 3 1 Mounting Hardware and Tools Required 8 3 2 Install a Liebert MPH in a Knurr Miracel Rack 8 3 2 1 Attach Mounting Brackets to the Liebert 8 3 2 2 Attach the Liebert MPH to Rack Rails 8 4 0 INSTALLING OPTIONAL ITEMS eee eee eee eee eee eee 9 4 1 RPC BDM Basic Display Module 9 4 2 Install an Optional RPC BDM in the
13. Integrated Cabinets HI Connectivity l Embedded Power Power Switching amp Controls Services EI DC Power E Monitoring E Precision Cooling Surge Protection Business Critical Continuity Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co 2009 Emerson Electric Co
14. Rack 9 4 2 1 Mounting Hardware ev nee URL hee len te Seb ee kan 9 4 2 2 RPC BDM Installation on Knurr MiracelFrame 9 4 3 Temperature Humidity Sensor Installation Optional 10 5 0 USING THE LIEBERT MPH nn nen 12 6 0 SPECIFICATIONS 2 A eo ua Ra et wre ee e ee 13 6 1 Awency Approval Sis o 75 52 09 SX re A ORT E POM ONE VES ERAS 15 6 2 Product Warranty Registration 15 FIGURES Figure 1 Liebert MPH units horizontal 10 rack mount and vertical zero U mount 3 Figure 2 Attach brackets to the Liebert MPH 5 Figure3 Inserting a spring nut into a T slot 6 Figure 4 Attaching a Liebert MPH to a Knurr Miracel horizontal frame member 6 Figure 5 Reposition input power Cord 7 Figure 6 Liebert MPH ready for installation in a rack horizontal mount 8 Figure 7 Rack mounting the Liebert MPH 8 Fisure 8 RPG BDM sioe a ay a edere e UR CR RATE Post Ve eR ee 9 Figure 9 RPC BDM installation rack 10 Figure 10 RPC BDM cable connection port on Liebert RPC
15. fer to the Liebert RPC manual SL 20825 available at the Liebert Web site www liebert com 3 Connect input power to the Liebert MPH 4 Route the rack equipment s power cables to the Liebert MPH following proper procedures and good practices such as segregating power cables from control cables and keeping cable bends to recommended angles 5 Connect the rack equipment s input power cables to the Liebert MPH recording where each piece of rack equipment is connected using the receptacle numbers on the Liebert MPH 6 Post the connection information on or near the rack and at any remote monitoring location 7 Switch On the connected rack equipment one piece at a time and verify that each is operating properly 8 Monitor and control the Liebert MPH as detailed in the Liebert RPC manual SL 20825 available at the Liebert Web site www liebert com 12 Specifications 6 0 SPECIFICATIONS Table 1 Liebert MPH Model numbers and specifications Input Output Max Rated Continuous Receptacle Socket Form Part Number Voltage Amps Amps kW Phase Plug Configuration Factor Monitoring Level Basic North American Applications MPH NBV27NXXH30 208 120 30 24 8 6 3 NEMA L21 30 27 IEC C13 Vertical MPH NBV27NXXF30 208 240 30 24 4 9 1 NEMA L6 30 27 IEC C13 Vertical MPH NBV27NXXE
16. he sensor support Choose where in the rack to install the sensor assembly Emerson recommends placing the sensor in the area that is likely to be warmest Hold the sensor bracket on a T slot on the Knurr Miracel frame where the sensor will be placed Insert the included quarter turn fastener through the rectangular hole in the sensor bracket base and into the T slot see Figure 11 Turn the fastener clockwise 90 degrees a quarter of a turn Route the sensor cable to the Liebert RPC and insert it into the card s external sensor port For further details refer to the Liebert RPC user manual SL 20825 which shipped with the card and is available at Liebert s Web site www liebert com Temperature humidity sensor mounting Sensor Support Lem Bracket Base 11 Using the Liebert MPH 5 0 USING THE LIEBERT MPH The Liebert MPH is ready for service after it has been installed in the rack and equipment has been connected to the output sockets Refer to the Liebert RPC user manual SL 20825 available at the Liebert Web site for full details on controlling and monitoring the Liebert MPH www liebert com Emerson recommends following these steps when starting a newly installed Liebert MPH 1 Shut down and unplug all equipment in the rack from input power sources 2 Ifthe Liebert MPH will be monitored over a network connect an Ethernet cable to the network port on the factory installed Liebert RPC for details re
17. ight side of Figure 2 2 Tighten the screws firmly 3 Insert two spring nuts into the appropriate T slot on the frame member Position the spring nuts to accommodate screws inserted through slots in the brackets To move the spring nuts press down on each with a small pointed object and slide each into position 4 Hold the Liebert MPH in place and attach the top of the unit to the rack with tool less fasteners 5 Tighten the screws firmly 6 Repeat Steps 3 through 5 for the lower bracket on the lower end of the Liebert MPH Figure2 Attach brackets to the Liebert MPH In Line Bracket 90 Degree Bracket Attachment on Liebert MPH Attachment on Liebert MPH used for mounting on horizontal used for mounting on an upright frame members frame member Figure 3 Installation in Knurr Miracel Rack Vertical Zero U Mount Inserting a spring nut into a T slot poe E T slot Spring nut inserted into T slot leaf spring goes inside E Figure 4 Attaching a Liebert MPH to a Knurr Miracel horizontal frame member Tool less fasteners supplied with Knurr rack Installation in Knurr Miracel Rack Vertical Zero U Mount 23 Reposition Input Power Cord The Liebert MPH is shipped from the factory with the input power cord entering from the end of the unit The cord can be repositioned if it will need to enter from the front To reposition the cord 1 Remove the four screws retaining the input
18. le and general mounting provisions are provided A single display can be used for up to four Liebert MPH connected in a Rack PDU Array Figure8 RPC BDM 4 2 4 2 1 4 2 2 EMERSON Network Power Install an Optional RPC BDM in the Rack The RPC BDM Basic Display Module can be mounted in the rack with either the included hardware or with a cable tie through the slot on the back of the module see Figure 9 Either method permits moving the RPC BDM to a different place in the same rack or to another rack Mounting Hardware Spring nut M5 1 Spacer sleeve 1 Special MPH screw 1 Cable clip 1 Tools Required Flat blade screwdriver RPC BDM Installation on Knurr Miracel Frame 1 Determine the mounting location in the rack 2 Inserta spring nut into a T slot on the frame member where the RPC BDM will be installed refer to Figure 3 9 Insert the Liebert MPH screw 1nto the spacer sleeve Insert the Liebert MPH screw into the spring nut and tighten securely with the screwdriver 5 Hangthe RPC BDM on the Liebert screw with the hooded mounting slot on the back of the RPC BDM see Figure 9 6 Connect the RPC BDM to the Liebert RPC with an Ethernet cable Be certain to connect the cable to the correct port on the Liebert RPC see Figure 10 gt Installing Optional Items Figure9 RPC BDM installation in rack Cable tie fits in small slot on RPC BDM loops around cabinet member Head of
19. nd of the bracket with the round holes is against the unit 2 Attach the bracket to the unit with four Phillips head screws tightening them firmly 3 Repeat Steps 1 and 2 for the bracket on the opposite side of the Liebert MPH Figure 6 Liebert MPH ready for installation in a rack horizontal mount Front mounting holes Slots will attach to rack mount rail 3 2 2 Attach the Liebert MPH to Rack Rails Determine where the Liebert MPH would be best placed in the rack for routing power and communi cation wires The rack mount Liebert MPH is installed horizontally in standard rack face position on the rails using the square EIA spaced holes They use four captive nuts snapped into the rail holes and four screws to attach the Liebert MPH brackets to the rail As with all Liebert rack mount equipment obtain the appropriate size rack mounting hardware kit for captive nuts and screws Figure 7 Rack mounting the Liebert MPH Screws go through bracket holes through rail and insert into the be captive nuts Installing Optional Items 4 0 INSTALLING OPTIONAL ITEMS 4 1 RPC BDM Basic Display Module The RPC BDM provides local display of electrical status for all connected Liebert MPH systems Dis play information is accessed via a navigation switch on the RPC BDM The RPC BDM is cable con nected to the Liebert RPC allowing the user to locate the display to suit the local reading requirements A 2 meter cab
20. olled North American Applications MPH NCV27NXXH30 208 120 30 24 8 6 3 NEMA L21 30 27 IEC C13 Vertical MPH NCV27NXXF30 208 240 30 24 4 9 1 NEMA L6 30 27 IEC C13 Vertical MPH NCV27NXXE30 208 240 20 16 3 3 1 NEMA L6 20 27 IEC C13 Vertical MPH NCV27NOXH30 208 120 30 24 8 6 3 NEMA L21 30 21 IEC C13 amp 6 IEC C19 Vertical MPH NCV27NOXF30 208 240 30 24 4 9 1 NEMA L6 30 21 IEC C13 amp 6 IEC C19 Vertical MPH NCV27AXXH30 208 120 30 24 8 6 3 NEMA L21 30 27 NEMA 5 20R T Slot Vertical MPH NCV27AXXD30 120 30 24 2 8 1 NEMA L5 30 27 NEMA 5 20R T Slot Vertical MPH NCV27AXXC30 120 20 16 1 9 1 NEMA L5 20 27 NEMA 5 20R T Slot Vertical MPH NCV27ANXH30 208 120 30 24 8 6 3 NEMA L21 30 21 IEC C13 amp 6 NEMA 5 20R T Slot Vertical MPH NCRO9NXXF30 208 240 30 24 4 9 1 NEMA L6 30 9 IEC C13 Rack mount MPH NCRO9NXXE30 208 240 20 16 3 3 1 NEMA L6 20 9 IEC C13 Rack mount MPH NCRO9AXXD30 120 30 24 2 8 1 NEMA L5 30 9 NEMA 5 20R T Slot Rack mount MPH NCRO9AXXC30 120 20 16 1 9 1 NEMA L5 20 9 NEMA 5 20R T Slot Rack mount European Applications MPH ECV27NXXR30 400 230 32 32 12 8 3 IEC 309 27 IEC C13 Vertical MPH ECV27NXXQ30 230 32 32 7 3 1 IEC 309 27 IEC C13 Vertical MPH ECV27NXX030 230 16 16 3 6 1 IEC C20 27 IEC C13 Vertical MPH ECV27NOXR30 400 230 32 32 12 8 3 IEC 309 21 C 13 amp 6 C 19 Vertical MPH ECV27NOXQ30 230 32 32 7 3 1 IEC 309 21 C 13 amp 6 C 19 Vertical MPH ECV27NOXO30 230 16 16
21. quipment in your rack enclosure before beginning to connect equipment to your Liebert MPH When connecting the rack equipment to the Liebert MPH s receptacles arrange cables and connections to avoid tangling and crisscrossing the power cables For power management purposes record the receptacle where each piece of equipment is connected Receptacles on the Liebert MPH have a numerical designation The Liebert MPH with more than one circuit has the outlets named with numbers and are grouped by branch with a number referring to the proper circuit breaker When connecting power to the Liebert MPH s receptacles follow generally accepted procedures such as routing the power cables separately from low voltage communication and control wires to prevent electromagnetic interference CAUTION All configuration steps must be completed before attempting to start equipment connected to the Liebert MPH Notice to European Union Customers Disposal of Old Appliances This product uses components that are dangerous for the environment such as electronic cards and other electronic components Any component that is removed must be taken to specialized collection and disposal centers If this unit must be dismantled this must be done by a specialized center for col lection and disposal of electric and electronics appliances or other dangerous substances This product has been supplied from an environmentally aware manufac turer that complies wi
22. th the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 CE The crossed out wheelie bin symbol at right is placed on this product to encourage you to recycle wherever possible Please be environmentally responsible and recycle this product through your recycling facility at its end of life Do not dispose of this product as unsorted municipal waste Follow local municipal waste ordinances for proper disposal provisions to reduce the environmental impact of waste electrical and electronic equipment WEEE For information regarding the scrapping of this equipment please browse http www eu emersonnetworkpower com Products session or Con tact us session or call our worldwide technical support at 00 80011554499 toll free number 39 0298250222 toll number based in Italy ROHS Compliance The Liebert MPH modules comply with the Restriction of Hazardous Substances Directive ROHS prohibiting use of six hazardous materials manufacturing of electronics including lead free solder FCC Compliance This unit complies with the limits for a Class A device pursuant to Part 15 of the FCC Rules Opera tion is subject to the following two conditions This device may not cause harmful interference and This device must accept any interference received including interference that may cause unde sired operation NOTE Q This equipment has been tested and found to comply with the limits for a Class
23. the Liebert MPH Screw in frame fits into hooded slot on back of RPC BDM Figure 10 RPC BDM cable connection port on Liebert RPC 4 3 RPC BDM cable connection port on Liebert RPC PN RPC 1000 Temperature Humidity Sensor Installation Optional Optional Liebert SN temperature humidity sensors are available to assist in monitoring conditions in the rack Liebert SN sensors are designed for installation in a Knurr Miracel without tools but each may be placed in any area to monitor temperature and humidity levels Each connects to the Liebert RPC which makes readings available to Liebert monitoring methods Only one mounting method is addressed in this manual attaching a single sensor with a bracket to a Knurr Miracel frame member For details on other mounting locations and methods refer to the Lie bert SN quick start guide SL 20840 or to the Liebert RPC user manual SL 20825 Each is available at Liebert s Web site www liebert com 10 Installing Optional Items To install a sensor on a Knurr Miracel frame member 1 Figure 11 Liebert SN Sensor Cable Liebert SN Sensor snapped into support Quarter Turn Fastener Rectangular protrusion passes through bracket slot above and into T slot on Knurr Miracel frame member below Assemble the Liebert SN and sensor bracket a Insert the sensor bracket base into one end of the sensor support as shown in Figure 11 b Snap the sensor into the other end of t

Download Pdf Manuals

image

Related Search

Related Contents

Manual de instrucciones Cryo Gauge  Manual for SIENA version 4.0 - the Department of Statistics    Sistema FOREVER BF084 - produzione e vendita generatori di vapore  - NEC Display Solutions Europe  Gabarit - Mode d`emploi - Mode d`emploi pour dialoguer avec les  User`s Manual - CNET Content Solutions  CareDirector Youth User Guide    