Home

StarTech.com NETRS23POEGB

image

Contents

1. Utilities D Em 2 Configure your hardware mode to support VSP Run the EM exe application to find the device hardware fe Ethernet Manager MAC Address Device ID 66 61 3C D6 4F 64 Enter the setup menu by double clicking the listed hardware Click Login by default settings there is no password Controller Status Setup Login Pasvord m 10 StarTech com Change the settings to COM Port save the changes and exit the setup menu 100 coMPot vg RS 232 3600 None fs sp 101 COMPot gt 1 RS 232 X 9600 None Jer 102 COMPort gt 9 5 232 z 35600 x none zle 1 1 gd BE I I II I Iaa t 103 OOO RS 232 h Baud rate parity data and stop bits 9600 v None v 8 v 1 16 Interface 3 Run the VSP Setup Program Double click the VSP COM exe application in the VSP folder on the supplied CD You may receive a message indicating that this driver has not yet passed Windows logo testing If so click Continue Anyway Select the COM ports to be redirected by checking the boxes next to them Please select the COM Ports you would ke to redrectto SerialIP 11 StarTech com Set the COM Port settings The following figure shows only one COM port setting being changed You may have 4 COM ports or 1 2 ports depending on the model you
2. industrial facilities to name just a few We offer an unmatched selection of computer parts cables A V products KVM and Serv er Management solutions serving a worldwide market through our locations in the United States Canada the United Kingdom and Taiwan Visit www startech com today for complete information about all our products and to access exclusive interactive tools such as the Cable Finder Parts Finder and the KVM Reference Guide
3. will need to set it 4 times for once for each COM port 12 168 1 254 im Create COM Port Select Ports Port Monitor Checking the Installation Go to the Device Manager right click My Computer Hardware Device Manager to check the installation a successful settings will look something like the following figure E9 Network adapters 5 9 Ports COM amp LPT 7 com cows 7 come 7 com I Communications Port COM1 Communications Port COM Printer Port LPT1 Processors 12 StarTech com Specifications Specification NETRS2321POE Connector RJ45 Speed 10 100Mbps Number of Ports 1 x RS 232 Signals TXD RXD RTS CTS DTR DSR DCD GND Connector DB9 Male RS 232 Parity None Odd Even Data Bits 6 7 8 Stop Bits 1 2 Speed 300 to 115 2Kbps Power Input 12V DC via DC Jack or 48V DC via Ethernet Cable PoE model only Power 110mA 12V DC Consumption Material Metal Gross Weight 250 5g 0 55 Ib 13 StarTech com Specification NETRS2321POE Operating 0 to 55C 32 to 131F Temperature Storage 20 to 85C 4 to 185F Temperature Operating 5 to 95 RH Humidity 14 StarTech com Technical Support StarTech com s lifetime technical support is an integral part of our com mit ment to provide industry leading solutions If you ever need help with your product visit www startech com support and access our com p
4. NETRS2321R0E Instruction Manual Ethernet Device Server 1 Port Industrial RS 232 Ethernet Device Server Power E StarTech com Making hard to find easy FCC Compliance Statement This equipment has been tested and found to comply with the limits for Class digital device pursuant to part 15 of the FCC Rules These limits are designed to provide rea sonable protection against harmful interference in a residential installation This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio com munications However there is no guarantee that interference will not occur in particu lar installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Use of Trademarks Registered Trademarks and other Protected Names and Symbols This manual may make reference to trademarks registered trademarks and other protected names and or symbol
5. cations eere ttr naamaan naai 13 Technical Support eere rere 15 Warranty Information StarTech com Hardware Guide Package Contents e 1x Driver CD 1 x Industrial Switch e 1 x Instruction Manual e 1 x Power Adapter Front Panel 1 Switch to Restore Default Settings This switch can be used to reset the product to its factory default settings Pressing the switch using either pen or similar tool will inmediately restore the unit to its default settings 2 RJ45 LAN Connector 10 100Mbps Ethernet port It supports the auto cross over feature and allows use of the same cable to connect to either Hub Switch or host computer 3 Heartbeat LED 4 7 12VDC Power Input DC Jack StarTech com Rear Panel 1 RS 232 Connector LED Indicators oO 1 10 100 Mbps LED amber color 2 Link Activity LED green color 3 Heartbeat LED green color LED Name Colour Function 10 100 Mbps On 100Mbps Off 10Mbps Link Activity On Linked Blinking Transfering Data Heartbeat Amber Blinking Normal Operation Not Blinking Malfunction 3 StarTech com Hardware installation 1 Use static electricity discharge precautions Remove possible static discharge potential from any objects that the adapter may come in contact with prior to installation This can be accomplished by touching a bare metal chassis rail after you have
6. d static IP address the DHCP server will be able to assign an IP address Note By default DHCP is disabled If you wish to support DHCP Enable it in the Adapter Setup Menu Note If you will set the IP address using another method you will need to use a static IP address To do this Disable DHCP this is the default setting in the Adapter Setup Menu 2 Setting the IP Address using a Web Browser Please ensure that your PC s IP address is set to the same subnet as the adapter If not you will need to change your PC s IP address from the Local Area Connection Properties menu shown below vernet Protocol Ter 0 ropert General General Connect using You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for Bj Realtek RTL8163 8110 Family Gigabit Ethernet NIC the appropriate IP settings Configure Obtain an IP address automatically Components checked are used by this connection Use the following IP address B Client for Microsoft Networks IP address 192 168 1 1 File and Printer Sharing for Microsoft Networks Subnet mask 255 255 255 0 M Y Internet Protocol TCP IP ne Default gateway Install install bian DNS server address autor Deen Use the following DNS server addresses Transmission Control Protacol Intemet Protocol The default Preferred DNS server wide area network protocol
7. rehensive selection of online tools documentation and downloads Warranty Information This product is backed by a one year warranty In addition StarTech com warrants its products against defects in materials and workmanship for the periods noted following the initial date of purchase During this period the products may be returned for repair or replacement with equivalent products at our discretion The warranty covers parts and labor costs only StarTech com does not war rant its products from defects or damages arising from misuse abuse alteration or normal wear and tear Limitation of Liability In no event shall the liability of StarTech com Ltd and StarTech com USA LLP or their officers directors employees or agents for any dam ages whether direct or indirect special punitive incidental consequen tial or otherwise loss of profits loss of business or any pecuniary loss arising out of or related to the use of the product exceed the actual price paid for the product Some states do not allow the exclusion or limitation of incidental or consequential damages If such laws apply the limita tions or exclusions contained in this statement may not apply to you 15 Making hard to find easy StarTech com has been making hard to find easy since 1985 providing high quality solutions to a diverse IT and A V customer base that spans many channels including government education and
8. s of third party companies not related in any way to StarTech com Where they occur these references are for illustrative purposes only and do not represent an endorsement of a product or service by StarTech com or an en dorsement of the product s to which this manual applies by the third party company in question Regardless of any direct acknowledgement elsewhere in the body of this doc ument StarTech com hereby acknowledges that all trademarks registered trademarks service marks and other protected names and or symbols contained in this manual and related documents are the property of their respective holders StarTech com Table of Contents Hardware Guide Package Contents Front Panel Rear sz EEE AERES REEERE 3 3 Hardware 4 Configuring the Adapter Setting the IP Address Setting the IP Address from a DHCP Server 5 Setting the IP Address using a Web Browser 5 Setting the IP Address using the Em exe Utility 6 Managing the Adapter Settings Controller Setup Menu Items Software Installation VSP Virtual COM Port Driver 9 Installing the VSP Virtual COM Port Driver esse 10 Specifi
9. s separated by dots If enabled these can be assigned by the DHCP server 4 numbers separated by dots If enabled these can be assigned by the DHCP server 4 numbers separated by dots If enabled these can be assigned by the DHCP server If disabled the IP address Subnet mask and Gateway address must be assigned manually StarTech com Menu Item Description If disabled the IP address Subnet mask and Gateway address must be assigned manually Port Number Any number between 1 and 65536 except 80 and 8080 these have been designated as the web pages Socket Type TCP Server Uses TCP protocol passively waits for Client TCP Client Uses TCP protocol actively connects to Server UDP Client Uses UDP protocol exchanges packets with Server without connection Spared function for the future expansion Currently has no function The Server IP address under TCP client or UDP client mode Baud Rate 300 115200 bps Parity Bits No Parity Even Odd Data Bits 5 6 7 8 Stop Bit 1 or2 RS 232 If packet mode is disabled the data received from the serial port will be transmitted immediately with minimal delay If packet mode is enabled the data will be saved in the buffer memory first and transmitted when the entire packet is received or when the buffer memory is full StarTech com Menu Item Description In packet mode the time constant used to de
10. termine if the packet is finished Acceptable range is 10 to 1000 ms User assigned device ID number Acceptable range is 0 to 65535 If this function is enabled the device will report the device ID after the socket is connected The format is Serial I O socket nnnnnA LFJ CR Digital I O socket nnnnnB LF CR There are eight bytes nnnnn is the 5 digit device ID LF is decimal 10 and CR is decimal 13 The login password can be empty or 1 to 15 characters long If the password is empty then no password is required for login Software Installation VSP Virtual COM Port Driver The VSP is a redirector driver that allows your applications to use serial devices provided by serial device servers on your network This redirection is achieved by creating one or more virtual COM port s that allow these networked serial devices to function as though they are directly connected to the local computer Since the redirector s virtual COM port s function much like standard Windows COM ports your application software sees no difference between local serial device and one provided by serial server StarTech com Installing the VSP Virtual COM Port Driver 1 Locate the necessary Software in the following folder on your driver CD The VSP COM exe is the redirector software The Em exe is used to setup the hardware mode to support VSP redirector a o Drivers 3 00 E amp 10 over IP 5 Drivers y
11. that provides communication At DNS 4 across diverse interconnected networks Remit DNS server I Show icon in taskbar when connected ak Cancel Cancel Run your browser and access the product by entering the default 192 168 1 254 or current IP address into your browser s address window Enter the password default has no password then go to Change your IP Address and make the necessary changes 5 StarTech comfa 3 Setting the IP Address using the Em exe Utility The Em exe is a Microsoft Windows based utility used to identify the adapters connected on the same subnet and network segment To run the Em exe utility please insert the driver CD supplied with the Adapter Open the program at the following location assume the CD ROM drive is at E E IO_over_IP Utilities Em Em exe 5 Drivers 3 01 8 2 10 over IP amp 00 Utilities Gen Managing the Adapter Settings When you enter the Adapter Setup Menu the following page will be available for your access By default there is no password for entry Controller Status 00 00 18 Setup Login Once you have entered the Controller Setup Menu and made the necessary changes click the Update button Also ensure that you make note of your password as you will need it to enter the setup menu again StarTech com Controller Setup Menu Items Controller Setup o EMO 80 Menu Item Description 4 number
12. turned off the power 2 If you will be externally powering the device connect the DC power adapter If connecting to a PoE switch hub or other device then a power adapter is not required as the product will draw its power from the host device it is connected to In this case ensure that your switching hub is the PoE type that can act as PSE Power Source Equipment 3 Connecting LAN cable Use a standard straight through Ethernet cable to connect to a Hub or Switch If you connect the adapter to your computer s Ethernet port instead you don t need to change to a cross over type cable since the adapter provides the auto cross over feature 4 Connect the Adapters serial port to your serial device 5 Use the DIN RAIL mounting Kit if you want to place the product on the industrial DIN RAIL optional Configuring the Adapter Setting the IP Address Please consult your Network Administrator to determine the appropri ate IP address The adapter comes with the factory installed IP address 192 168 1 254 It is ready to accept a new IP address from a DHCP Server If your network has a DHCP server it will automatically assign an IP address to the Adapter the first time it is connected and powered up StarTech com 1 Setting the IP Address from a DHCP Server A DHCP server will automatically assign an IP address dynamic address as well as Subnet Mask and Gateway to this adapter If you power up the Adapter without a fixe

Download Pdf Manuals

image

Related Search

Related Contents

24 comptines pour s`amuser CPEM LOIRE 09  

Copyright © All rights reserved.
Failed to retrieve file