1. lever open all the way CPU Power Connector Detail 2 Prepare the I O shield Do not remove the three circular knockouts that are at the edge next to the openings for the NIC USB Serial A and 1394 ports Use caution so you do not deform the shield Note Make sure you install the labels on the correct side of the 1 0 shield Note the orientation of the cutouts in the drawing before attaching your labels D Remove the backing from the 1 0 Shield labels included with your server board Press each label onto the 1 0 shield as shown Install the 1 0 shield of chassis The labels Should be visible from the outside of the chassis cy Insert one side edge of shield as shown Push shield firmly into chassis opening until it clicks into place Attach the Bumpers Remove the backing from each bumper D Press a bumper onto each of the five circles B Open the Load Plate amp Push the rear tab with your finger tip to bring the front end of the load plate up slightly Auxiliary Signal Power Detail Go to Side 2 Installing the I O Shield and Attach O Labels Attach the Labels to the I O Shield Labels on outside face of I O shield Intel Server Chassis SC5650WS shown Sa Chassis Back shield installs from inside Panel Opening C Remove the Processor Protective Cover E Take the processor out of the box and remo
2. 5650WS Supported Maximum 95 Maximum 130 watt processor Processor watt processor Supported One maximum ONE maximum 300 watt graphics card in Graphics Card 150 watt graphics PCI Express Slot 6 or TWO maximum card in PCI 150 watt graphics cards Empty PCI Express Slot6 Express Slot 3 when a graphics card is installed in PCI Express slot 4 NOTE Graphics cards with power greater than 75 W must be self cooled with exhaust out the back of the chassis SP install Workstation Board Bumpers NOTE If you are using an Intel Server Chassis you must install the chassis bumpers included with the chassis Refer to your Intel Workstation Board and Intel Server Chassis Quick Start User s Guide for proper bumper installation guidelines If you are using a non Intel server chassis that includes bumpers refer to the non Intel server chassis documentation for the correct bumper installation procedure If the non Intel server chassis does not include bumpers then you should consult with the chassis vendor to determine whether bumpers are required or not Prepare Workstation Board Rotate board to show underside and hold upright as shown CAUTION To avoid damage to the board do not lay flat with the component side down intel Locate the five circles as shown B Attach the Workstation Board Install the Processor s The Intel Server Chassis SC5600Base and the Intel Server Chassi
3. Intel Workstation Board S5520SC Quick Start User s Guide Thank you for buying the Intel Workstation Board S 5520SC The following information will help you integrate your new server board into a server chassis The Intel Workstation Board S5520SC is designed for use with the Intel Server Chassis SC5600Base and the Intel Server Chassis SCS650WS For details on these chassis or to select a third party chassis please visit http support intel com support motherboards server When installing the server board into a reference chassis refer to the reference chassis instructions Service Guides are also available on the CDs that accompanied your Intel Workstation Board S5520SC If you are not familiar with ESD Electrostatic Discharge procedures used during system integration please see the Intel Workstation Board S5520SC Service Guide available on the Intel Server Deployment Toolkit 3 0 CD or at http support intel com support motherboards server S5520SC manual Atm WORKSTATION inside Read all caution and safety A statements in this document before performing any of the instructions Also see the ntel Server Board and Server Chassis Safety Information document at http support intel com support motherboards server sb cs 010770 Atm for complete safety information Installation and service of A this product should only be performed by qualified service personnel to avoid risk of inj
4. er Connector Detail Attach the CPU 2 power connector to the workstation board E Close Load Plate and Socket Lever Make Workstation Board Power Connections o Close the load plate all the way as aZ Pa gt D Attach the main power connector to VX the workstation board Close the socket lever SA CAUTION o Remove the protective cover after it been Er HE eee I oy ae Se automatically disengaged from the load plate Cee Cee eee I WINING IMPORTANT NOTE If you are using a non Intel il 5 Ul CPU 1 Socket matching tab on each workstation board socket server chassis with an ATX power supply see the documentation that came with your chassis for installation information Preparing the Chassis Observe normal ESD Electrostatic Discharge procedures Place your Intel Server Chassis on a flat anti static surface to perform the following integration procedures Observe ESD procedures before reaching inside to make server board connections or install components LJ JAA APS Oana N bak A Open the Socket Lever Push the lever handle down and away from the socket to release it Rotate the
5. otches on the processor align with the two CAUTION The underside orientation posts on the socket of the processor has Install the processor as shown components that may damage the socket wires if installed improperly obo p aang Opona aaa maaana I O Openings Orientation Notches Components Processor must align correctly with the socket opening before installation DO NOT DROP processor ket Orientation Posts Minimum Hardware Requirements To avoid integration difficulties and possible board damage your system must meet the following minimum requirements e Processor Minimum of one Intel Xeon Processor 5500 Series or one Intel Xeon Processor 5600 Series e Supports maximum 95 watt processor in the Intel Server Chassis SC5600Base e Supports maximum 130 watt processor in the Intel Server Chassis SC5650WS e Heat Sink s Minimum of one active heat sink for the Intel server Chassis SC5600Base and SCS650WS e Memory Type Minimum of one 1 GB 240 pin RDIMM or UDIMM DDR3 800 DDR3 1066 or DDR3 1333 e AC Power SSI EPS 12V compliant power supply Recommended minimum of 670 Watts with 3 A of standby current or calculate your system power demand with the power budget tool For a complete list of compatible processors heat sinks and memory see http support intel com support motherboards server s5520SC 4 the ised a the risa A erver Chassis erver Chassis CAUTION C5600Base SC
6. s SC5650WS use different screws Cauti to attach the workstation board to the chassis Use the screws indicated for your chassis dUTIONS For a non Intel server chassis use the fasteners that came with your chassis 1 When opening a socket DO NOT TOUCH the gold socket wires e ntel Server Chassis SC5600Base Attach the board to the chassis at the nine locations indicated by the solid blue arrows in the figure and at the one location indicated by the solid red arrow e Intel Server Chassis SC5650WS Push down firmly to engage the snap top standoffs at the location indicated by the solid red arrow rr 2 When unpacking a processor hold by the edges only to avoid touching the gold gt contact wires SS eaa o lHa Use screws to attach the board to the chassis at l the nine locations indicated by the solid blue ain arrows a n a Intel Server Cx Intel Server i me VD Chassis SF Chassis Hi lt 3 C5600Base S amp S SC5650WS 6 A Attach auxiliary power signal connector to the workstation board Attach the CPU 1 power connector to the workstation board Main Pow
7. ury from electrical shock or energy hazard Observe normal ESD Electrostatic Discharge procedures during system integration to avoid possible damage to server board and or other components Tools Required 2 Phillips screwdriver Anti static wrist strap Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries Other names and brands may be claimed as the property of others Copyright 2011 Intel Corporation All rights reserved E39546 009 Install the Workstation Board Intel Server Chassis IMPORTANT NOTE If you are using a SC5600Base Shown non Intel server chassis See your chassis documentation for preparatory Steps prior to server board installation A Insert Workstation Board Place the board into the chassis making sure that back panel I O openings and chassis standoffs align correctly e When using the Intel Server Chassis Intel Server Chassis SC5600Base remove the rear chassis fan oe and then insert the 1 0 connector side back of the board first e When using the Intel Server Chassis SC5650WS remove the front drive bay and rear chassis fan and then insert the front of the board first Slide the board back so the 1 0 connectors fit through the I 0 shield 3 D Install the Processor s continued D Install the Processor Orient the processor with the socket so that the orientation n
8. ve the protective shipping cover gt C