1. e Select Input Voltage The Line R provides a three position User Selectable Voltage Switch for adjusting the input voltage for the region where it is being used example Russia 220V Denmark 230V United Kingdom 240V Slide the switch to select the proper voltage for your location e Plug the Line R into Wall Outlet Detach your computer s power cord from the back of your computer and use it to plug the Line R into the wall socket Use one of the two power cords supplied with the Line R to reconnect your computer to any of the four outlets on the back of the Line R The Line R should only be used in buildings having proper grounding on a branch circuit protected by a fuse or circuit breaker Connect Your Equipment Plug equipment into the Line R rear panel outlets and switch the equipment ON The equipment will not be powered until the Line R is switched ON CAUTION The total power consumption of all equipment plugged into the Line R must not exceed the ratings listed in the Specifications table below A total load in excess of the listed ratings will cause the push button circuit breaker to trip Switch ON the Line R Press the front panel power switch to the on 1 position This switch may be used as the master switch for the device and all equipment connected to it Specifications Characteristics Model LE600I Model LE12001 600 W or 600 VA 1200 W or 1200 VA Nominal Output Volt
2. Line R Automatic Voltage Regulator Models LE600I and LE1200I Arc by Schneider Electric Thank you for purchasing APC s Line R Automatic Voltage Regulator Please fill out and mail the product warranty registration form or fill out an online form at www apc com The Line R automatically corrects brownouts by boosting low voltage and overvoltages by stepping down high voltage from the power utility service to levels that are safe for computers as well as other sensitive equipment APC s Line R provides the highest degree of protection from line voltage sags and swells and has been designed for many years of reliable maintenance free service Applications CAUTION The total power consumption of all equipment plugged into the Line R must not exceed the Maximum Output Power Capacity rating listed in the Specifications table A total load in excess of this rating will cause the circuit breaker to trip The Line R is designed for use with voltage sensitive equipment such as a computer monitor inkjet printer scanner or fax It is also designed for use with home electronics TVs stereos CD players etc Appliances not suitable for use with the Line R are items such as refrigerators freezers power tools air conditioners dehumidifiers blenders or any device that employs an AC motor for operation Not for use with life sustaining equipment and any device with a power requirement exceeding the Maximum Output Pow
3. age 220 230 or 240V User Selectable Nominal Input Current 2 6A 5 2 A 160 270V Selector Switch set to 220V 166 280V Selector Switch set to 230V 170 290V Selector Switch set to 240V Maximum Output Power Capacity Acceptable Voltage Range Tolerance Rated Input Voltage 250Vac Maximum Acceptable Input Voltage 300V Surge Energy 300 Joules Output Regulation 10 Response Time lt 2 AC Cycles Efficiency gt 92 Nominal Frequency 47 63 Hz Number of Outlets 4 32 104 F 0 40 C Operating Temperature Relative Humidity 0 95 Non condensing Dimensions 4 6 x 84x 5 5 inches 118 x 214 x 141 mm Weight 3 1 kg 6 8 Ib 4 2 kg 9 2 1b Limited Warranty American Power Conversion APC warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its sole option any such defective products To obtain service under warranty you must obtain a Return Material Authorization RMA number from APC or an APC service center Products must be returned to APC or an APC service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment which has been damaged by accident negligence or mis
4. application or has been altered or modified in any way This warranty applies to the original purchaser who must have proper registered the product within 10 days of purchase EXCEPT AS PROVIDED HEREIN AMERICAN POWER CONVERSION MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE Some countries do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT SHALL APC BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which may vary from location to location APC Contact Information Online Technical Support http support apc com Web Site www apc com USA Canada 800 800 4272 Worldwide 1 401 789 5735 India 1 800 4254 877 272 Europe Middle East Africa 35391 702020 2010 APC by Schneider Electric APC the APC logo and SurgeArrest are owned by Schneider Electric Industries S A S American Power Conversion Corporation or their affiliated co
5. er Capacity rating listed in the Specifications table Features Lights when input voltage is high Flashes when input voltage is above rated Input Voltage Range NS Input voltage is normal VY Lights when input voltage is low Flashes when input voltage is below rated Input Voltage Range Thepower switch applies and removes power to from the Line R I on O off Power Switch Connect the Supplied Power Cord from any Outlet to Your Device AC Outlets 4 connect equipment here Connect Your Detachable Device Power Cord Here and to an AC Wall Outlet User Selectable Voltage Switch see Select Input Voltage Push Button Circuit Breaker Power Switch The Line R provides a front panel power switch I on O off which functions as the master power switch for the Line R and all devices connected to the device Push Button Circuit Breaker The Line R provides a push button circuit breaker on the rear panel of the unit to protect it from being overloaded If the circuit breaker trips unplug the last device connected to the unit and push the circuit breaker fully inward Installation e Placement Please install the Line R in a protected environment free of excessive dust mechanical vibration inflammable gases and explosive or corrosive atmospheres Do not block the top or side air vents on the unit Allow 1 inch 2 5 cm minimum vent clearance 2 5 cm 1 inch
6. mpanies All other trademarks are property of their respective owners 990 1287A