Home
Sun Blade T6340 Server Module Getting Started Guide
Contents
1. Note The default user name is root and the default password is changeme For example ssh root 10 3 212 24 Password Sun TM Integrated Lights Out Manager Version 2 0 4 0 Copyright 2008 Sun Microsystems Inc All rights reserved Warning password is set to factory default You are now connected to the CMM ILOM software CLI Vv To Log Into the Service Module SP Using the CLI 1 Navigate to the server module SP by typing this ILOM command gt cd CH BLn SP cli Where n is an integer 0 11 that identifies the target server module 2 Type the start command 3 Type y to continue or n to cancel After you enter y the ILOM software running on the server module SP prompts for the password specific to that server module SP Note The CMM ILOM logs on to the server module ILOM using the user name that is in the user target under CH BLn SP cli where n is the server module number 4 Type the password when prompted The default password is changeme The following display shows an example of the procedure above gt start Are you sure you want to start CH BL2 SP cli y n y start Connecting to CH BL2 SP cli as user root start Change the user property to connect as a different user Password changeme Waiting for daemons to initialize Daemons ready Sun TM Integrated Lights Out Manager Version 2 0 4 0 Copyright 2008 Sun Microsystems Inc All rights reserved U
2. 008
3. 1 1 f 1 1 1 1 1 Seamer Figure Legend Computer connected to CMM RJ 45 serial connector 1 Server local or remote Computer connected to dongle cable RJ 45 serial connector 2 Computer connected to RJ 45 Ethernet remote KVM supported 3 Ethernet cable connected to RJ 45 Ethernet connector on the chassis management module CMM NET MGMT 0 8 Keyboard video monitor mouse local KVM 4 CMM with two connectors 9 Dongle cable with one RJ 45 serial two USB 2 connectors and one HD15 pin connector VGA 5 RJ 45 cable connected to CMM serial port SER MGT 10 Sun Blade T6340 server module with service processor SP Connect to the CMM SP Using Ethernet Port NET MGT 0 Use the CMM service processor proxy and the command line interface to navigate to the Sun Blade T6340 server module SP ILOM firmware You can also use the CMM SP web interface to control the server module Items 1 through 3 This method is described in this getting started guide The methods below are described in the Sun Blade T6340 Server Module Installation Guide 820 3900 Connect to the CMM serial connector SER MGT Use the CMM SP proxy to navigate to the server module SP ILOM firmware This method supports CLI access only Item 6 Use a dongle cable to connect directly to the server module SP with an RJ45 serial connection This method supports CLI access only Items 7 and 9 Dongle cables are intended for setup testing or se
4. SS Ry SUN microsystems Sun Blade T6340 Server Module Getting Started Guide This guide describes the minimum steps you must perform to power on and boot your server module You should install optional components before powering on your server module Detailed installation information can be found in the Sun Blade T6340 Server Module Installation Guide 820 3900 which is available at this web site http docs sun com app d ocs prod blade t6340 l en hic Shipping Kit Contents and Safety and Compliance Information Before installing the server module refer to the printed safety document Important Safety Information for Sun Hardware Systems 816 7190 and the Sun Blade T6340 Server Module Safety and Compliance Manual 820 3903 Available online at the Sun documentation web site Figure Legend 1 Documentation 2 Server module 3 Shipping carton 4 Antistatic wrist strap 5 Customer information sheet 912 8 Ibs 9 0 kg Register the System Locate the serial number for your system on the customer information sheet on the shipping carton Go to this website to register your system http www sun com service warranty index xml reg Connection Options This section summarizes five methods to connect to the server module Complete procedures are provided in the Sun Blade T6340 Server Module Installation Guide 820 3900 ewww cwnn a commmewnnnn ween ae x x x Fi i 1 i
5. or translated documentation select your language at this website http docs sun com Task Document Type Part Number or URL Review known issues workarounds and new Sun Blade T6340 Server Module Product Notes 820 3901 information Connect server to network configure software Sun Blade T6340 Server Module Installation Guide 820 3900 Set remote access View system status and event Sun Integrated Lights Out Manager 2 0 Supplement for Sun Blade T6340 logs Server Modules 820 3904 Diagnose and troubleshoot the server module Sun Blade T6340 Server Module Service Manual 820 3902 Remove and replace components Review safety information Sun Blade T6340 Server Module Safety and Compliance Manual 820 3903 Important Safety Information for Sun Hardware Systems 816 7190 Chassis specific hardware and ILOM information http docs sun com app docs prod blade srvr hic Sun Contact Information Topic URL Patches and firmware http www sun com support updates Technical support http www sun com service contacting Submitting comments http www sun com hwdocs feedback Please include the title and part number of your document with your feedback Sun Blade T6340 Server Module Getting Started Guide 820 3899 Copyright 2008 Sun Microsystems Inc All rights reserved Copyright 2008 Sun Microsystems Inc Tous droits r serv s sS Sun Microsystems Inc Part No 820 3899 10 v2 Rev A Giusti esta 6 September 2
6. rvice purposes and should be removed when not in use Use a dongle cable to connect directly to the server module host with a local keyboard video and mouse local KVM Items 8 and 9 Connect to the server module SP using the Ethernet DHCP or static This method supports a CLI or a web interface The web interface can also control the server module host using a remote keyboard video and mouse remote KVM Items 1 through 3 VY To Install the Server Module Into the Chassis 1 2 3 Remove a filler panel from the chassis Insert the server module in the chassis until it is about 1 5 cm one half inch from the front of the chassis Push the ejector levers in simultaneously until they snap in place When the server module is plugged in standby power is supplied to the service processor and the green OK LED on the front panel blinks T Caution For proper cooling ensure that all chassis slots are filled with a server module or filler panel Connecting Through the Chassis CMM Ethernet Port You can connect to the CMM through the RJ 45 NET MGT 0 Ethernet port Before you can use the Ethernet connection you must know the IP address for the CMM Vv To Log Into the CMM Using SSH ILOM supports SSH access to the CLI over the Ethernet 1 Log into the CMM with the SSH client In the example below replace 10 3 212 24 with the IP address of your CMM 2 Type your password when prompted
7. se is subject to license terms Warning password is set to factory default gt You are now connected to the server module service processor V To Power On the Host 1 Type the start SYS command and type y gt start SYS Are you sure you want to start SYS y n y Starting SYS 2 Type the start SP console command and type y gt start SP console Are you sure you want to start SP console y n y Serial console started To stop type 0 0 0 gt POST enabling CMP 0 threads ffffffff ffffffff 0 0 0 gt POST enabling CMP 1 threads ffffffff ffffffff After you issue the start command the CPU and memory controllers initialize and the OpenBoot PROM OBP firmware initializes The system may take several minutes to complete POST diagnostics and boot If a boot device installed with the Solaris OS is accessible locally that device will be booted Otherwise the system will use the boot net command to seek a boot device on the network For more information about system configuration and installing the Solaris OS see the Sun Blade T6340 Server Module Installation Guide 820 3900 Firmware Upgrades For instructions on upgrading the firmware on your server module refer to the Sun Integrated Lights out Manager 2 0 User s Guide 820 1188 Documentation for This Product Find the server module documentation at this URL http docs sun com app docs prod blade t6340 1l en thic F
Download Pdf Manuals
Related Search
Related Contents
Guide d`Utilisation Cables Direct 4OPT-101H HDR-XR200VE Manual do Usuário - Repetidor M300EW Qedit for Windows Quick Start Guide NT2S-SF121B-E NT2S-SF122B-E Programmable Terminal 2612 KB Eng & French 8x14 02-10.cdr Copyright © All rights reserved.
Failed to retrieve file