1. rSource 14 rSource 15 rSource 16 Source 13 Source 14 Source 15 Source 16 Note Maximum 10 characters Cancel lt Figure 4 4 gt Source Stamping Messages panel There are 16 sources corresponded with the 16 Capcodes If Show Source is selected on the Option panel the source stamping message is appended to a new incoming message For example if Source 1 is set to Boss and the message is received on the first Capcode then a pager displays Boss at the end of the message Source 2 is connected to second Capcode Source 3 is connected to third Capcode and so on Each source stamping message can have up to 10 characters To save changes and exit click the OK button The Cancel button exits without saving any changes Source stamping messages must not contain and characters 4 4 Configuration panel The Configuration panel controls the environment of the software lt Figure 4 5 gt shows the configuration panel To SUN TELECOM INTERNATIONAL INC 9 18 User s Manual TITAN III Alphanumeric Pager Program Software v 3 2 save changes and exit click the OK button The Cancel button exits without saving any changes Configuration Communication Channel Parallel Port Serial Port e En Enable LPT ILPT 1 0x378 0x37F COM Port com 1 x case Check LPT Speed Baud Rate a500 z Open Log In Password Interval Curre
2. My Music My Pictures a Pager1 pgr Files of type Jpager par x Cancel J Open as read only lt Figure 4 10 gt Open File Dialog box 4 5 1 2 Save The Save menu allows the user to save a configuration to a file with a file extension of pgr Clicking the Save menu displays the Save File Dialog The saved file can be opened by the Open menu for future use 4 5 1 3 Print This menu makes a hard copy of the data that is currently specified in the software 4 5 1 4 Exit Clicking the Exit menu terminates the software Before terminating the software the window shown in lt Figure 3 3 gt is displayed 4 5 2 Pager Menu The Pager menu consists of four sub menus Read Write Auto Write and Write Info 4 5 2 1 Read The Read menu reads data from a pager This menu can be executed by pressing the F5 key also To read the data from a pager the pager password must match the password stored in the pager The progress bar on the main panel shows the progress of the read operation During the reading procedure Reading is displayed on the status bar of the main panel If reading is successful then Success is displayed on the status bar of the main panel If reading SUN TELECOM INTERNATIONAL INC 11 18 User s Manual TITAN III Alphanumeric Pager Program Software v 3 2 fails Fail is displayed on the status bar of the main panel and a separate error message window is displayed After successful
3. Frequency 331 0125 MHz Replace Password Serial Number lt Figure 4 1 gt Main panel 4 1 1 Address frame The address frame can configure up to 16 addresses Capcodes their types and priority option Priority options may not be available on all versions of Titan II FLEX Each Capcode can be either Personal type or Mail type The short Capcode range is from 1 to 1933312 and from 1998849 to 2031614 The long Capcode range is from 2101249 to 4291000000 It is recommended not to use from 3223326721 to 4291000000 on the long Capcode range due to FLEX protocol Short Capcodes can be specified in any of the 16 Capcode fields Long Capcodes must be specified in an odd numbered field As you can see in lt Figure 4 1 gt the third and fifteenth Capcode fields are in the long Capcode range The Corresponding even Capcode fields are disabled The first Capcode field must be used to be able to write to a pager Entering an illegal Capcode causes an error message Clicking on the Personal button changes it to Mail and another click changes it back to Personal toggles back and forth There are auto increase and decrease functions If Address 1 check box is checked and Increase or Decrease buttons are clicked Capcode 1 will be increased or decreased by one respectively Checking the Other Addresses check box will affect Capcodes 2 through 16 If one or both of these check boxe
4. About Titan IN FLEX 4 5 5 Tool bar 4 5 6 Status bar 5 Default values of parameters and their allowed ranges 6 Error messages 7 Hardware connection 7 1 Parallel Port 7 2 Serial Port 8 Contact Info SUN TELECOM INTERNATIONAL INC TITAN II Alphanumeric Pager Program Software v 3 2 3 18 User s Manual TITAN III Alphanumeric Pager Program Software v 3 2 1 Software explanation This software is used to program the TITAN III FLEX Alphanumeric pager It is an upgrade from the previous version The software allows a user to program the addresses Capcodes PLL frequency Inventory control number various options power up greeting message signal phase collapse value mail type display timeout interval signal polarity canned messages and source stamping messages of a pager The software has a function to let a user preview the write information before writing to a pager and print it out It has an auto write function so a user can write many pagers automatically In addition a user is able to read data from a pager save the data to a file and load the file for future use 2 Installing software N a Installing software To install the software double click on the setup exe file The Install Wizard will start Follow the instructions to install the software After installation a short cut icon TITAN III FLEX PPS v 3 2 is created on the desktop as well as under Start gt Programs 2 2 System requirements gt Pro
5. The Help menu consists of only one sub menu About Titan HI FLEX 4 5 4 1 About Titan IIT FLEX The About Titan II FLEX menu displays the software about box shown in lt Figure 4 12 gt About Titan Ill FLEX Titan Ill FLEX PPS v 3 2 All rights are reserved to HANTEL CO LTD software team lt Figure 4 12 gt About Titan IIT FLEX 4 5 5 Tool bar The Tool bar has nine icons as shown in lt Figure 4 13 gt From the left they are Open Save Print Read Write Write Info Option Message Box and Configuration This tool bar allows a user to select one of nine listed menus in a quick manner Heo oe lt Figure 4 13 gt Tool bar 4 5 6 Status bar The Status bar displays current information It is located on the bottom of the main panel see Figure 3 2 The Progress bar is located on the status bar The Progress bar shows the progress of reading or writing from to a pager There are two text panes on the right side of the progress bar The first one displays Writing Reading Success Fail and Timeout Writing is displayed during a write procedure and Reading for a read procedure Success and Fail shows the result of the writing or reading procedures Timeout is only displayed when the COM port is used to communicate with a pager Timeout is another type of failure when writing or reading The second one dis
6. You have entered an illegal Reason Illegal characters are entered where prohibited Error 105 character Response Delete illegal characters You have entered an illegal Reason Illegal Capcode is entered Error 106 Capcode Response Check the Capcode range You have entered an illegal Reason Illegal PLL frequency is entered Error 107 PLL frequency Response Check the PLL frequency Error while creating Reason Error for using serial port Error 108 Thread WatchComm Response Terminate software and start again Reason Error for using serial port Error 109 Queue is full Response Terminate software and start again Reason Writing to a pager with empty first Capcode Error 111 First Capcode must be used Response Use the first Capcode Reason Error for using serial port Error 112 Fail to initialize COM port Response Open COM port manually from Configuration panel Reason Trying to open another COM port while one of the Error 113 Port is already opened COM port is opened Response Close the COM port first and open it Reason The serial buffer does not respond to PC Response Check if Serial Port is selected on Configuration Error 114 Timeout panel Check if the serial buffer is turned on and connected to PC Reason While writing reading a pager via serial port data is Data is corrupted during the corrupted Error 115 transmission Response Check the connection between a PC and the serial buffer Reason Trying t
7. reading all fields are updated with the newly read data 4 5 2 2 Write The Write menu writes data to a pager This menu can be executed by pressing the F6 key or space bar also Before writing the data to a pager the software checks if there are any invalid values in the Address PLL Frequency and Pager Password frames The progress bar on the main panel shows the progress of the write operation During the writing procedure Writing is displayed on the status bar of the main panel If writing is successful Success is displayed on the status bar of the main panel If writing fails Fail is displayed on the status bar of the main panel and a separate error message window is displayed 4 5 2 3 Auto Write The Auto Write menu writes a pager automatically every few seconds as specified by the Auto Write Interval on the Configuration panel The Auto Write menu can be executed by pressing the F7 key also Clicking the Auto Write menu one more time stops the auto write procedure Disconnecting the pager from a PC stops the auto write procedure also While writing a pager the progress bar on the main panel shows the progress of the write operation and the status bar displays Writing When the write is complete Success is displayed on the status bar of the main panel If writing fails Fail is displayed on the status bar of the main panel and a separate error window is displayed When Success
8. 4 2 Option panel The Option panel controls all the available options for the TITAN II FLEX pager The Option panel consists of frames for different types of options To save changes and exit click the OK button The Cancel button exits without saving any changes The available options are defined below Depending on the version of TITAN III FLEX pager you are programming the available options will vary 4 2 1 Options frame gt gt gt Personal Slot Number If checked will show the slot number a personal message is received on default checked Mail Slot Number If checked will show the slot number a mail drop message is received on default unchecked Duplicate Message If checked and a duplicate message is received the duplicate icon is displayed for the message default checked Power Up Screen If checked the Power Up Greeting message is displayed when the pager is turned on default checked Out of Range Antenna If checked an antenna icon is displayed for out of service area If unchecked an antenna icon is displayed for in service area default unchecked Low Cell Reminder If checked an alert sounds every two hours to indicate a low battery condition default checked Smart Unread If checked and there are unread messages there is no reminder alert from 10 00 PM to 08 00 AM of the next day If unchecked reminder alerts sound regardless of the current time default checked New Mail Indicati
9. 8000 Because the current version of the serial port buffer supports only a Baud Rate of 9600 The Baud Rate settings must be 9600 The serial port can be closed and opened manually with the Open and Close buttons 4 4 3 Log In Password frame SUN TELECOM INTERNATIONAL INC 10 18 User s Manual TITAN III Alphanumeric Pager Program Software v 3 2 To change the log in password enter the current password in the Current PW edit box and the new password in the New 6 9 PW and Verify PW edit boxes They must not contain and characters The New password and Verify password must be the same The Password can be up to 10 characters After entering the New password and Verify password click the Change button to change the password 4 4 4 Interval frame Auto Write Interval sets the interval value when the Auto Write function is used For example if auto write interval is set to 10 it will write a pager every 10 seconds This value must be greater than the time duration of writing a pager For serial port the minimum value is 10 and for parallel port the minimum value is 3 4 5 Menu bar Tool bar and Status bar 4 5 1 File Menu File Menu consists of four sub menus Open Save Print and Exit 4 5 1 1 Open The Open menu allows the user to open a saved configuration file with a file extension of pgr Clicking the Open menu displays the Open File Dialog box shown in lt Figure 4 10 gt Ce
10. User s Manual TITAN II Alphanumeric Pager Program Software v 3 2 TITAN III FLEX Alphanumeric Pager Program Software v 3 2 User s Manual 2004 5 SUN TELECOM INTERNATIONAL INC 1 18 User s Manual Contents 1 Software explanation 2 Installing software 2 1 Installing software 2 2 System requirements 3 Starting terminating software 3 1 Starting software 3 2 Terminating software 4 Functions 4 1 Main panel 4 1 1 Address frame 4 1 2 PLL Frequency frame 4 1 3 Pager Password frame 4 1 4 Serial Number SN 4 1 5 Inventory Control Number 4 2 Option panel 4 2 1 Options frame 4 2 2 Error Message Indicator frame 4 2 3 Private Time frame 4 2 4 Power Up Greeting frame 4 2 5 Signal Phase frame 4 2 6 Collapse frame 4 2 7 Mail Type frame 4 2 8 Display Timeout frame 4 2 9 Signal Polarity frame 4 3 Messages panel 4 3 1 Canned Message panel 4 3 2 Source Stamping Message panel 44 Configuration panel 4 4 1 Parallel Port frame 4 4 2 Serial Port frame 4 4 3 Log In Password frame 44 4 Interval frame 4 4 5 Read Data Format frame 4 5 Menu bar Tool bar and Status bar 4 5 1 File menu 4 5 1 1 Open 4 5 1 2 Save 4 5 1 3 Print 4 5 1 4 Exit SUN TELECOM INTERNATIONAL INC TITAN II Alphanumeric Pager Program Software v 3 2 2 18 User s Manual 4 5 2 Pager menu 4 5 2 1 Read 4 5 2 2 Write 4 5 2 3 Auto Write 4 5 2 4 Write Info 4 5 3 Setting menu 4 5 3 1 Option 4 5 3 2 Message Box 4 5 3 3 Configuration 4 5 4 Help menu 4 5 4 1
11. cessor Intel Pentium or better gt OS Windows 95 98 2000 XP ME Windows NT 3 1 or later gt Hard disk space Approximately 10 MBytes gt Monitor resolution Best at 1024 x 768 3 Starting terminating software W Starting software After successful installation of the software Windows creates an icon TITAN M FLEX v 3 2 on the desktop Double clicking of the icon starts the software You can also select Start gt Programs gt TITAN III FLEX v 3 2 to start the software The first window after starting the software is the Log In dialog box lt Figure 3 1 gt Enter the proper password and clicking the OK button to start the Pager Program Software PPS The login password can be a combination of up to 10 alphanumeric characters The Cancel button terminates the Log In dialog box and exits the software lt Figure 3 2 gt shows the main panel that appears after clicking the OK button on the Log In dialog box with the correct password Ci xi SUN TELECOM INT Titan FLEX Alphanumeric Pager Program Software Password Cancel lt Figure 3 1 gt Log In dialog box SUN TELECOM INTERNATIONAL INC 4 18 User s Manual TITAN II Alphanumeric Pager Program Software v 3 2 TITAN Ill FLEX PAGER PROGRAM SOFTWARE 43 2 Status bar lt Figure 3 2 gt Main PPS start up screen 3 2 Terminating software Selecting Alt X the X on the right top corner of the window or F
12. ile gt Exit terminates the software When terminating the software lt Figure 3 3 gt appears TITAN ITI FLEX lt Figure 3 3 gt Exit window Clicking either the Yes or No button terminates the software The Yes button saves the data whereas the No button does not The Cancel button does not terminate the software and go back to the main panel 4 Functions 4 1 Main panel As displayed in lt Figure 3 2 gt the user must read a pager or open a saved configuration to continue Once the user reads a pager or opens a saved configuration the main panel shows all the options The main panel controls the address Capcode PLL frequency and pager password lt Figure 4 1 gt shows the main panel of the software SUN TELECOM INTERNATIONAL INC 5 18 User s Manual TITAN III Alphanumeric Pager Program Software v 3 2 m TITAN Ill FLEX PAGER PROGRAM SOFTWARE 3 0 Arch File Pager Setting Help 2aH4a Scda A Rpe Address Priority Priority 1 wl ar 55574 m 9 Mail 2 a oOo oOo m 10 Personal Mail aa 20249 oOo m 11 Personal Personal 14 r o m 12 Personal Personal 5 e 34 y 13 Personal 6 14 7 15 8 Personal Personal Personal C 125674 r Personal Personal C asar Personal Personal B m 16 Personal M Address 1 Inventory Control Other Addresses Increase Decrease PLL Frequency Pager Password 929 0125 MHz 932 0000 MHz cimen Paes card e
13. is displayed on the status bar of the main panel place another pager in the cradle to write the next pager 4 5 2 4 Write Info The Write Info menu displays the data to be written to a pager in the info box shown in lt Figure 4 11 gt As shown in lt Figure 4 11 gt there are two buttons Print and Close Clicking the Print button makes a hard copy via a printer Close button closes the box Information 0001234567 PERSONAL Not Used N A Not Used Not Used Not Used 6 Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used lt Figure 4 11 gt Write Information box 4 5 3 Setting Menu The Setting menu consists of three sub menus Option Message Box and Configuration SUN TELECOM INTERNATIONAL INC 12 18 User s Manual TITAN III Alphanumeric Pager Program Software v 3 2 4 5 3 1 Option The Option menu displays the Option panel shown in lt Figure 4 2 gt 4 5 3 2 Message Box The Message Box menu displays either the Canned Message panel shown in lt Figure 4 3 gt or the Source Stamping Message panel shown in lt Figure 4 4 gt depending on the selection of Canned Message or Source Stamping Message in Option panel If neither is selected the Canned Message panel is displayed 4 5 3 3 Configuration The Configuration menu displays the Configuration panel shown in lt Figure 4 5 gt 4 5 4 Help
14. message when the pager is turned on It can have up to 16 characters To change the power up greeting message click the Edit button If you enter f or an error message is displayed default SUN TELECOM 4 2 5 Signal Phase frame Sets the signal phase of the pager There are five options Any Phase Phase A Phase B Phase C and Phase D It is recommended not to change this value because the pager may not operate properly with a different setting default Any Phase 4 2 6 Collapse frame Sets the collapse value This value is related to the battery life The range of the value is from zero to seven default four 4 2 7 Mail Type frame If set to Update each Mail type Capcode will store the most recent message If set to History each Mail type Capcode will store up to the last 8 messages received Clicking the button toggles from Update to History to Update 4 2 8 Display Timeout frame Sets the time interval before going back to the initial screen of the pager after the user stops pressing buttons It has two options 8 seconds and 12 seconds Clicking the button toggles from 8 seconds to 12 seconds to 8 seconds default 8 seconds 4 2 9 Signal Polarity frame Sets the signal polarity It can be either Normal or Inverted It is recommended not to change this value because the pager may not operate properly with a different setting default Normal 4 3 Messages panel There are two panels for messages Canned Me
15. nt PW Auto Write Interval New PW jio seconds minumum value depends on Verify PW Change communicatoin channel Cance lt Figure 4 5 gt Configuration panel 4 4 1 Parallel Port frame To use the parallel port for the connection between a pager and a PC select Parallel Port LPT is enabled and can be set to LPT1 or LPT2 When the parallel port is selected Check LPT Speed checks for the fastest communication speed with a pager Clicking the Check LPT Speed button displays the message box shown in lt Figure 4 6 gt TITAN III FLEX x Make sure if the pager is connected A It may take a few seconds to several minutes Do you want to proceed lt Figure 4 6 gt Check LPT Speed Click Yes to proceed While checking the LPT speed a user must not change anything in the software until one of following two message boxes shown in lt Figure 4 7 gt and lt Figure 4 8 gt are displayed TITAN III FLEX x TITAN III FLEX x A LPT speed detection Failed AN LPT speed has been successfully detected lt Figure 4 7 gt Fail to check LPT Speed lt Figure 4 8 gt Success to check LPT speed 4 4 2 Serial Port frame Select Serial Port to use the serial port to communicate with a pager To use the serial port the COM Port and Baud Rate must be set properly The COM port can be defined as COM1 through COM20 The Baud Rate can be defined as 9600 19200 38400 57600 or 12
16. o write or read a pager while COM port is Error 116 COM port is not opened not opened Response Open the COM port from Configuration panel Minimum auto write interval Reason Entered the number less than minimum allowed for COM port is 10 seconds Error 117 interval value Minimum auto write interval Response Change the interval value for LPT is 3 seconds Reason There is no data on EEPROM for a pager Error 118 EEPROM is empty Response The pager must be replaced Reason Given pager password does not match with the You entered wrong pager password that pager has Error 119 password Response Check the pager password and enter the correct password 16 18 User s Manual TITAN UI Alphanumeric Pager Program Software v 3 2 Error during initialization of Reason Error for using parallel port Error 121 parallel port Response Terminate software and run again Reason Error during writing procedure via LPT Failure during writing Error 122 Response Check the connection and try again Or do the procedure via LPT Check LPT Speed on Configuration panel Reason This software only writes reads to from TITAN II FLEX pager Error 123 Titan version is different Response Check the pager model name and make sure it is TITAN II FLEX Reason Bad connection while reading a pager Failure during reading Error 125 Response Check the connection between a PC and a pager procedure and try again Invent
17. on If checked and a pager has a new message the power on icon blinks in stand by mode If unchecked the power on icon does not blink even if there are new messages default unchecked Reminder Default If checked the reminder alert is enabled If unchecked the reminder alert is disabled default checked Show Source Displays the address a message was received on at the end of the message The sources can be edited in the Source Stamping Message panel default unchecked Canned Message If checked Canned Messages are enabled They can be edited in the Canned Message panel default unchecked Note that both of Show Source and Canned Message cannot be enabled at the same time Error Message If checked the pager displays an E indicator in front of the message when the message contains errors SUN TELECOM INTERNATIONAL INC 7 18 User s Manual TITAN II Alphanumeric Pager Program Software v 3 2 4 2 2 Error Message Indicator frame The user can select either Underscore or E indicator for error message indicator If the user selects underscore then the erred characters will be displayed with the underscore The E indicator simply displays an E mark in front of the message 4 2 3 Private Time frame The user can enable or disable the private time option by clicking the check mark on the frame The user can also set the Private Time ON and OFF values 4 2 4 Power Up Greeting frame Sets the greeting
18. ory Control Number Reason 12 characters are not specified on this field Error 127 must consist of 12 Response Either leave the field blank or enter 12 characters alphanumeric characters Reason The cable jig is not firmly connected to pager Pager is not connected Error 128 Response Check the cable connection and hold down the jig Check the cable connection to the pager firmly Reason The EEPROM data has been corrupted Pager Firmware version Response Insert battery into the pager and wait until the Error 129 does not match pager starts up Then try to read the pager again via the PPS If it does not work then the pager must be replaced Reason The version of the pager you try to write Pager F W version mismatches that of PPS has Error 130 mismatches Please read Response Read the pager again so that the PPS updates the the pager again pager version information SUN TELECOM INTERNATIONAL INC 17 18 User s Manual TITAN II Alphanumeric Pager Program Software v 3 2 7 Hardware connection 7 1 Parallel Port FA Jig _ To LPT1 or LPT2 To pager 7 2 Serial Port jig To COM port To pager Power 8 Contact Info Company Sun Telecom International Inc 5875 Peachtree Industrial Blvd Suite 160 Norcross GA 30092 TEL 678 720 0303 SUN TELECOM INTERNATIONAL INC 18 18
19. plays COM when the COM port is selected from the Configuration panel The software checks the connection between the PC and serial port buffer every second If a connection is made Connect is displayed on the text pane Disconnect is displayed when there is no connection between them If LPT is selected from the Configuration panel then LPT is displayed on the text pane 5 Default value of parameters and their allowed ranges Panel Fields Default Range Main panel Address 1 1234567 Short amp Long Capcode SUN TELECOM INTERNATIONAL INC 13 18 User s Manual TITAN II Alphanumeric Pager Program Software v 3 2 Address 3 5 7 9 11 13 None Short amp Long Capcode 15 Address 2 4 6 8 10 12 None Short Capcode 14 16 PLL Frequency 931 0125 929 0125 932 0000 Pager Password None 6 characters or numbers Inventory Control Number Empty 12 alphanumeric characters Personal Slot Number Checked N A Mail Slot Number Unchecked N A Duplicate Message Checked N A Show Source Unchecked N A Canned Message Unchecked N A Power Up Screen Checked N A Out of Range Antenna Unchecked N A Low Cell Reminder Checked N A Smart Unread Checked N A New Mail Indication Unchecked N A Reminder Default Checked N A Option panel Error Message Indicator E indicator E indicator or underscore Priva
20. rce 11 lt 11 gt 10 characters or numbers Source 12 lt 12 gt 10 characters or numbers Source 13 lt 13 gt 10 characters or numbers Source 14 lt 14 gt 10 characters or numbers Source 15 lt 15 gt 10 characters or numbers Source 16 lt 16 gt 10 characters or numbers Parallel Port Disabled N A LPT LPT1 LPT1 LPT2 Serial Port Enabled N A COM Port COM1 COM COM20 Swine oes 9600 19200 38400 57600 Configuration 128000 panel Interval 10 Parallel Port 3sec 99sec Serial Port 10sec 99sec E Saath Window Screen Text File Format Window Format Screen Format 6 Error messages Error Message Contents Reason and Response Number Reason Incorrect login password is given Error 101 Incorrect Login password Response Enter the correct login password case sensitive Reason Specified file is not for TITAN IN FLEX Error 102 Load file has been failed Response Make sure the file is for TITAN III FLEX Pager password must consist Reason Pager password is not given or it is not 6 characters Error 103 of 6 characters Response Give the 6 character pager password New and Verify passwords Reason New and verify passwords are different Error 104 do not match Response Make sure they are the same SUN TELECOM INTERNATIONAL INC 15 18 User s Manual TITAN II Alphanumeric Pager Program Software v 3 2 SUN TELECOM INTERNATIONAL INC
21. s are checked writing to a pager will increase or decrease the corresponding Capcode s by one automatically Each Capcode has a priority option If the user wants to enable the priority then simply click on the priority check mark in front of the Capcode field 4 1 2 PLL Frequency frame The range of the PLL frequency is from 929 0125 MHz to 932 0000MHz The fractional part of the frequency must be divisible by 125 An illegal PLL frequency causes an error message 4 1 3 Pager Password frame SUN TELECOM INTERNATIONAL INC 6 18 User s Manual TITAN II Alphanumeric Pager Program Software v 3 2 To be able to write or read to from a pager the correct pager password must be specified The pager password must consist of 6 alphanumeric characters Current PW field must have the correct pager password to write or read to form a pager If the pager password needs to be changed check the Replace PW check box The edit box is enabled to allow a new pager password to be entered If you enter or characters an error message is displayed 4 1 4 Serial Number SN The Serial Number field cannot be edited It only displays the serial number of the pager that was read When writing a pager the serial number is ignored 4 1 5 Inventory Control Number The Inventory Control Number field can have up to twelve alphanumeric characters Entering or characters causes an error message
22. ssage panel and Source Stamping Message panel 4 3 1 Canned Message panel Canned Message panel is displayed when Canned Message is selected from the Option panel The screen shot of the panel is shown in lt Figure 4 3 gt SUN TELECOM INTERNATIONAL INC 8 18 User s Manual TITAN II Alphanumeric Pager Program Software v 3 2 xi Message 2 Honey Friend Message 3 _ Message 4 Love you Home Message 5 _ Message 6 Office Congrats Message 7 _ Message 8 Urgent Miss you Message 3 _ Message 10 Good Night Hello Note Maximum 11 characters Cancel i lt Figure 4 3 gt Canned Message panel The number of canned message is ten and each message can have up to 11 characters It must not contain and characters If so an error message is displayed To save changes and exit click the OK button The Cancel button exits without saving any changes 4 3 2 Source Stamping Message panel This panel sets the source stamping messages The screen shot of the panel is shown in lt Figure 4 4 gt Source Stamping Messages Source 1 Source 2 Source 3 Source 4 Source Source 2 Source 3 Source 4 Source 5 Source 6 Source 7 Source Source 5 Source 6 Source i Source 8 Source 9 Source 10 Sourcel1 Source 12 Source g Source 10 Source 11 Source 12 Sourcel3
23. te Time Enable Enable Disable On Time 22 00 0 00 23 59 Off Time 07 00 0 00 23 59 Power Up Greeting SUN TELECOM 16 characters or numbers Any Phase Phase A Phase Signal Phase Any Phase B Phase C Phase D Collapse 4 0 7 Mail Type Update Update History Display Timeout 8 seconds 8 seconds 12 seconds Signal Polarity Normal Normal Inverted Message 1 Honey 11 characters or numbers Canned Message Message 2 Friend 11 characters or numbers panel Message 3 Love you 11 characters or numbers Message 4 Home 11 characters or numbers Message 5 Office 11 characters or numbers Message 6 Congrats 11 characters or numbers Message 7 Urgent 11 characters or numbers Message 8 Miss you 11 characters or numbers Message 9 Good Night 11 characters or numbers Message 10 Hello 11 characters or numbers SUN TELECOM INTERNATIONAL INC 14 18 User s Manual TITAN II Alphanumeric Pager Program Software v 3 2 Source 1 lt I gt 10 characters or numbers Source 2 lt 2 gt 10 characters or numbers Source 3 lt 3 gt 10 characters or numbers Source 4 lt 4 gt 10 characters or numbers Source 5 lt 5 gt 10 characters or numbers Source 6 lt 6 gt 10 characters or numbers Source 7 lt 7 gt 10 characters or numbers Source 8 lt 8 gt 10 characters or numbers Source Stamping Source 9 lt 9 gt 10 characters or numbers Message panel Source 10 lt 10 gt 10 characters or numbers Sou