Sun Integrated Lights Out Manager 2.0 Supplement for Sun Blade

image

Contents

1. ILOM SP and type the default user name root with the default password changeme After you have successfully logged in the SP displays its default command prompt gt 6 Type the version command which returns output similar to the following gt version SP firmware version 2 0 3 6 SP firmware build number 36472 SP firmware date Tue Sep 2 13 47 18 PDT 2008 SP filesystem version 0 1 17 Chapter 2 Firmware Update Procedures 7 The ILOM firmware version and build number are listed above Using the Web Interface 1 Connect to the ILOM Web interface by entering the IP address of the server s SP in your browser s address field Use https For example https 129 146 53 150 2 Log in to the ILOM SP and type the default user name root with the default password changeme The System Information gt Versions page appears It includes the firmware version and build number FIGURE 2 1 ILOM Versions Page There Loo our Role r Administrator root SP Hostname SUNSP001E682EF121 Sun Integrated Lights Out Manager i System Information itori i User Management Remote Control i Versions Session Time Out Components Identification Information Versions View the version of LOM firmware currently in use Version Information Property Value SP Firmware Version 2 0 3 6 SP Firmware Build Number 36472 SP Firmware Date Tue Sep 2 13 47 18 PDT 2008 SP Filesystem Versio
2. Out Manager Firmware Upgrade Reset SP Firmware Upgrade A firmware upgrade will cause ILOM to be reset and may also reset the server if the BIOS gets updated It is recommended that a clean shutdown of the server be done prior to the upgrade procedure An upgrade takes about 6 minutes to complete ILOM will enter a special mode to load new firmware Users signed in through other sessions will lose connectivity when ILOM is reset Enter Upgrade Mode _ Flashing the Firmware With the ILOM CLI 1 Log onto the ILOM CLI through the Management Ethernet Port see Using the CLI Through the Management Ethernet Port on page 6 or the serial port see Using the CLI Through the Serial Port on page 7 2 From the ILOM CLI use the following command load source tftp tftpserver ilom firmware pkg where tftpserver is the trivial file transfer protocol TFTP server that contains the update and ilom firmware pkg is the firmware image file for example ilom X6450 2 0 3 6 r36158 pkg Resetting the Service Processor After flashing the ILOM BIOS firmware you must reset the ILOM SP To reset the ILOM SP you can do any of the following m From the ILOM SP graphical Web interface navigate to the Maintenance tab and the Reset SP tab and then click the Reset SP button Chapter 2 Firmware Update Procedures 11 FIGURE 2 3 ILOM Reset Service Processor Window Role User Administrator root SP Hostname SUN
3. Recoverable MB T_DIMM1 0x1c 7 0 Temperature 27 0 degrees C ok na na na 72 000 75 000 na unc ucr unc ucr MB Pn V_VCC where n is 0 3 3 n Voltage 1 317 0 Volts ok na na na na na na Chapter 3 Sensor Definitions 23 TABLE 3 7 Sensor Complete List of Sensors Continued Data Assertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled MB V_VTT Oxe 7 0 Voltage 1 197 0 Volts ok na 1 027 na na 1 386 1 449 lcr ucr unr lcr ucr unr MB V_ 1V5 Oxf 7 0 Voltage 1 498 0 Volts ok na 1 349 na na 1 646 na lcr ucr lcr ucr ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 TABLE 3 7 Complete List of Sensors Continued Sensor Data Sensor ID MB V_ 1V8B0 0x16 Entity ID 7 0 Sensor Type Analog Voltage Sensor Reading 1 802 0 Volts Status ok Lower Non Recoverable na Lower Critical 1 617 Lower Non Critical na Upper Non Critical na Upper Cri
4. SP CLI or web interface Using the SP to Update Firmware on page 4 BIOS Recovery DOS boot with Afudos Recovering the BIOS Firmware on updates BIOS only page 13 for Afudos ILOM Upgrade SP CLI or web interface Using the SP to Update Firmware on page 4 ILOM Recovery SOCFLASH Recovering the ILOM Firmware on page 14 Note The ILOM is also known as the service processor SP and it is sometimes referred to in the user interface as the BMC To ensure proper operation it is recommended that you synchronize your firmware updates so that if you update one you should update the others as well a Using the SP ILOM updates both the ILOM and BIOS firmware and the CPLD m If you recover the ILOM using SOCFLASH or if you recover the BIOS using Afudos after the recovery you should run the SP update procedure to synchronize the ILOM and the BIOS firmware Using the SP to Update Firmware This section describes how to use the service processor to update the ILOM and BIOS Note The procedures in this section also update the CPLD Use the procedures in this section to update the BIOS and the SP firmware This section can be used when you need to m Recover the BIOS m Update the BIOS a Update the ILOM Use the following sections in order 1 Obtain the IP address of the Service Processor See Getting the Service Processor s IP Address on page 5 2 Log on to the Service Process
5. Sun Integrated Lights Out Manager 2 0 Supplement for Sun Blade X6450 Server Module contains information about Integrated Lights Out Manager ILOM 2 0 that is specific to the Sun Blade X6450 server module For a complete discussion of ILOM 2 0 and its capabilities along with user procedures see the Sun Integrated Lights Out Manager 2 0 User s Guide the Addendum to the Sun Integrated Lights Out Manager 2 0 User s Guide and the Sun Blade X6450 Server Module Product Notes Related Documentation The document set for the Sun Blade X6450 server module is described in the Where To Find Sun Blade X6450 Server Module Server Documentation sheet that is packed with your system You can also find the documentation at http docs sun com Translated versions of some of these documents are available at http docs sun com Select a language from the drop down list and navigate to your document collection using the Product category link Available translations include Simplified Chinese French and Japanese English documentation is revised more frequently and might be more up to date than the translated documentation For all Sun documentation go to http docs sun com Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document with your feed
6. 7 Complete List of Sensors Continued Sensor Data Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status 12 222 0 Volts ok 9 513 10 773 na na 13 167 14 427 Icr Inr ucr unr lcr Inr ucr unr MB V_ 3V3STBYO 0x6d 7 0 Voltage 3 287 0 Volts ok na 2 993 na na 3 667 na lcr ucr lcr ucr MB V_ 3V3STBY1 0x e 7 0 Voltage 3 249 0 Volts ok Chapter 3 Sensor Definitions 27 Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical TABLE 3 7 Complete List of Sensors Continued Sensor Data Lower Non Recoverable na Lower Critical 2 975 Lower Non Critical na Upper Non Critical na Upper Critical 3 642 Upper N
7. ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 Etats Unis Tous droits r serv s Cette distribution peut comprendre des composants d velopp s par des tierces parties Sun Sun Microsystems le logo Sun Java Netra Solaris Sun Ray Sun ONE Studio Sun Blade X6450 Server Module Sun Storage TekTM RAID Manager software et Sun company logo sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc ou ses filales aux Etats Unis et dans d autres pays Intel est une marque de fabrique ou une marque d pos e de Intel Corporation ou de sa filiale aux Etats Unis et dans d autres pays Intel Xeon est une marque de fabrique ou une marque d pos e de Intel Corporation ou de sa filiale aux Etats Unis et dans d autres pays Intel Inside est une marque de fabrique ou une marque d pos e de Intel Corporation ou de sa filiale aux Etats Unis et dans d autres pays L utilisation de pieces detachees ou d unites centrales de remplacement est limitee aux reparations ou a l echange standard d unites centrales pour les produits exportes conformement a la legislation americaine en matiere d exportation Sauf autorisation par le
8. Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable MB V_ 1V5B1 0x71 7 0 Voltage 1 365 0 Volts ok na 1 349 na na 1 646 na lcr ucr lcr ucr MB V_ 2V5STBY 0x14 7 0 Voltage 2 496 0 Volts ok na 2 249 na na 2 743 na ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 TABLE 3 7 Complete List of Sensors Continued Sensor Data Assertions Enabled Icr ucr Deassertions Enabled Icr ucr Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled MB V_ 1V8B1 0x6b 7 0 Voltage 1 802 0 Volts ok na 1 617 na na 1 978 na lcr ucr lcr ucr MB V_ 0V9B0 0x72 7 0 Voltage 0 893 0 Volts ok na 0 806 na na 0 989 na lcr ucr lcr ucr Chap
9. Manager Administration Guide TABLE 3 1 through TABLE 3 6 list the sensor related events TABLE 3 7 provides a list of all of the sensors Entity Presence TABLE 3 1 Entity Presence Sensor Event Description Action Entity Device Present A FRU was installed Or if SP was Add to log during normal Presence 0x02 rebooted or AC power cycled FRU operation or if SP is rebooted was detected as being present Entity Device Absent A FRU was removed Add to log during normal Presence 0x01 operation and FRU was removed 17 Power TABLE 3 2 Power Sensor Event Description Action Power Supply Asserted Chassis power supply Nominally this is asserted and only added PSx PWROKx redundant side is now OK to the log if it was deasserted when the SP boots CMM controls chassis power supply and chassis LED behavior Power Supply DeAsserted Chassis power supply Add to log PSx PWROKx redundant side is not OK CMM controls chassis power supply and chassis LED behavior Power Supply Asserted Chassis power supply AC Nominally this is deasserted and only PSx VINERRx input AC power plug is not added to the log if it was deasserted when being supplied input voltage the SP boots User to check power plug x CMM controls chassis power supply and and that it is being supplied chassis LED behavior voltage Power Supply DeAsserted Chassis power supply AC Add to log PSx VINERRx input AC Power plug is CMM controls chassis pow
10. NY R SUN microsystems Sun Integrated Lights Out Manager 2 0 Supplement for Sun Blade X6450 Server Module Sun Microsystems Inc www sun com Part No 820 5834 11 May 2009 Revision A Submit comments about this document by clicking the Feedback link at http docs sun com Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved This distribution may include materials developed by third parties Sun Sun Microsystems the Sun logo Java Netra Solaris Sun Ray Sun ONE Studio Sun Blade X6450 Server Module Sun StorageTek RAID Manager software and Sun company logo are trademarks or registered trademarks of Sun Microsystems Inc or its subsidiaries in the U S and other countries Intel is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries Intel Xeon is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries Intel Inside is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries Use of any spare or replacement CPUs is limited to repair or one for one replacement of CPUs in products exported in compliance with U S export laws Use of CPUs as product upgrades unless authorized by the US Government is strictly prohibited DOCUMENTATION IS PROVIDED AS IS AND
11. RI 0x2b 10 0 Power Supply Digital State Predictive Failure Deasserted PS1 VINERRO 0x2d 10 1 Power Supply Digital State Predictive Failure Deasserted PS1 VINERRI 0x2e 10 1 Power Supply Digital State Predictive Failure Deasserted ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009
12. SP00144F794F77 Sun Integrated Lights Out Manager Firmware Upgrade Reset SP Reset Service Processor Resetting the SP disconnects your current ILOM session You must log in again to continue working in ILOM Reset SP m From the ILOM CLI use the following command reset SP a Using IPMItool use the following command ipmitool U root P password H SP IP bmc reset cold where SP IP is the IP address of the service processor m Reset the ILOM SP by shutting down the host then removing and restoring AC power cords to the system For complete details see the ILOM documentation for your server Clearing CMOS Settings Optional If you cannot get output to your serial console after the flash upgrade you might have to clear CMOS settings This is because your default CMOS settings might have been changed by the new BIOS upgrade 12 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 To clear CMOS settings use the following commands in this example the default username root and the default password changeme are used ipmitool U root P changeme H SP IP chassis power off ipmitool U root P changeme H SP IP chassis bootdev disk clear cmos yes where SP IP is the IP address of the service processor Note The P option might not be available on the Windows and Solaris versions of IPMItool Instead IPMItool prompts for a password Recovering the BIOS Firmware Use the f
13. States Asserted Sensor ID Entity ID Entity Presence Availability State Device Absent MB MCH DC4 PRSNT 0x85 32 16 Entity Presence Availability State Device Absent MB MCH DC5 PRSNT 0x86 32 17 Entity Presence Availability State Device Absent MB MCH DD0 PRSNT 0x87 32 18 Entity Presence Availability State Device Present MB MCH DD1 PRSNT 0x88 32 19 Entity Presence Availability State Device Present MB MCH DD2 PRSNT 0x89 32 20 Entity Presence Availability State Device Absent MB MCH DD3 PRSNT 0x8a 32 21 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 TABLE 3 7 Complete List of Sensors Continued Sensor Data Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Entity Presence Availability State Device Absent MB MCH DD4 PRSNT 0x8b 32 22 Entity Presence Availability State Device Absent MB MCH DD5 PRSNT 0x8c 32 23 Entity Presence Availability State Device Absent MB FEM PRSNT 0x8f 44 0 Entity Presence Availability State Device Absent MB REM PRSNT 0x90 44 1 Ent
14. TABLE 3 7 Complete List of Sensors Continued Sensor Data Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Entity Presence Availability State Device Absent MB MCH DB4 PRSNT 0x7f 32 10 Entity Presence Availability State Device Absent MB MCH DB5 PRSNT 0x80 32 11 Entity Presence Availability State Device Absent MB MCH DC0 PRSNT 0x81 32 12 Entity Presence Availability State Device Present MB MCH DC1 PRSNT 0x82 32 13 Entity Presence Availability State Device Present MB MCH DC2 PRSNT 0x83 32 14 Entity Presence Availability State Device Absent MB MCH DC3 PRSNT 0x84 32 15 Chapter 3 Sensor Definitions 36 TABLE 3 7 Complete List of Sensors Continued Sensor Data Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete
15. a A message appears stating that the BMC was not found The system takes up to five minutes to boot b Press F8 to get a list of boot devices c Choose the flash device to boot from 6 Once the flash device is booted run the following commands socflash p 1 sp binary file 7 After a successful flash use the r option to reset the SP socflash r 8 Access the BIOS Setup Utility to confirm that the BIOS does not report that the BMC was not found Notes m If the backup is selected b backup filename sufficient free space to store the SP binary backup file must be present on the USB flash device 14 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 m The BIOS is not upgraded by this emergency recovery procedure Perform a second ILOM based flash upgrade to update the BIOS version m This emergency flash recovery procedure returns the SP to the default configuration a The ILOM SPBIOS pkg file format for example ilom X6450 2 0 3 6 r36158 pkg cannot be used for emergency recovery Use the ilom2026 bin recovery image instead Chapter 2 Firmware Update Procedures 15 16 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 CHAPTER 3 Sensor Definitions This chapter lists and describes the Sun Blade X6450 server module sensors Instructions for displaying the sensors are in the Sun Integrated Lights Out Manager 2 0 User s Guide or the Sun Blade X6450 Server Module Embedded Lights Out
16. back Sun Integrated Lights Out Manager 2 0 Supplement for Sun Blade X6450 Server Module part number 820 5834 11 vi ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 CHAPTER 1 Introduction This supplement provides platform specific information related to ILOM 2 0 running on the Sun Blade X6450 server module The following topics are covered in this supplement m Chapter 2 Firmware Update Procedures m Chapter 3 Sensor Definitions ILOM 2 0 Features Supported The Sun Blade X6450 server module supports the entire ILOM 2 0 feature set except for the delayed BIOS upgrade The Addendum to the Sun Integrated Lights Out Manager 2 0 User s Guide describes a method of recovering from a corrupt ILOM using the SP U boot environment Do not use this method on the Sun Blade X6450 Instead follow the instructions in Recovering the ILOM Firmware on page 14 2 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 CHAPTER 2 Firmware Update Procedures Overview This chapter provides procedures for updating flashing the firmware that resides on The server itself BIOS The server s Service Processor ILOM It also provides procedures for recovering the BIOS or ILOM images TABLE 2 1 shows the tasks the methods used and the sections that describe them TABLE 2 1 Tasks Methods and Sections To Do This Task Use This Method Described in This Section BIOS Upgrade
17. cess the OK to Remove LED remains OFF This section describes two methods of flashing the ILOM BIOS firmware Use the ILOM Web interface Use the ILOM CLI load command Note You can also use the Sun xVM Ops Center if it is available Online documentation for Sun xVM Ops Center can be found at http wikis sun com display xvmOCIdot1 Home Chapter 2 Firmware Update Procedures 9 Note Due to increased memory use during Web interface operations you might find that using the ILOM web interface which is the easiest procedure will not work satisfactorily In such a case you will need to use the ILOM CLI load command or the Sun xVM Ops Center to flash the firmware Flashing the Firmware with the ILOM Web Interface 1 Log into the ILOM web interface by pointing your browser at the IP address of the Service Processor Use https For example https 10 6 78 144 2 Select the Maintenance tab 3 Select the Firmware Upgrade tab 4 Click the Enter Upgrade Mode button 5 Browse for the flash image file you click the Upload button the ILOM will shut down the host and any open files A Caution Power off the host before proceeding If the host is powered on when might be corrupted 6 Click the Upload button 10 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 FIGURE 2 2 Firmware Upgrade Screen Role User Administrator root SP Hostname SUNSP00144F794F77 Sun Integrated Lights
18. e chassis CMM Establish an SSH connection using the following command ssh 1 root sp ip where sp_ip is the IP address of the server s Service Processor Enter the default password when you are prompted changeme After you have successfully logged in the SP displays its default command prompt gt 6 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 2 Type the version command which returns output similar to the following gt version SP firmware version 2 0 3 6 SP firmware build number 36472 SP firmware date Tue Sep 2 13 47 18 PDT 2008 SP filesystem version 0 1 17 The ILOM SP firmware version and build number are listed above Using the CLI Through the Serial Port 1 Configure your terminal device or the terminal emulation software running on a laptop or PC to the following settings 8N1 eight data bits no parity one stop bit 9600 baud Disable hardware flow control CTS RTS Disable software flow control XON XOFF 2 Connect a dongle cable to the server module 3 Connect a serial cable from the RJ 45 SER MGT port on the server module dongle to your terminal device or PC 4 Press Enter on the terminal device to establish a connection between that terminal device and the server s SP The SP displays a login prompt SUNSP0003BA84D777 login Here 0003BA84D777 is the Ethernet MAC address of the SP This will be different for each server 5 Log in to the
19. ed Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID TABLE 3 7 Complete List of Sensors Continued Sensor Data Lower Non Recoverable 1000 000 Lower Critical 1500 000 Lower Non Critical 2000 000 Upper Non Critical 7000 000 Upper Critical 7500 000 Upper Non Recoverable 8000 000 Inc lcr Inr unc ucr unr Inc lcr Inr unc ucr unr FMn FAIL where n is the fan module number 29 n Fan Digital State Predictive Failure Deasserted PSn PRSNT 10 Entity Presence Availability State Device Present PS0 PWROKO 0x5e 10 0 Power Supply Digital State State Asserted PSO PWROK 1 0x5f 10 0 Power Supply Digital State State Asserted PS1 PWROKO 0x61 Chapter 3 Sensor Definitions 39 40 TABLE 3 7 Complete List of Sensors Continued Sensor Data Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted 10 1 Power Supply Digital State State Asserted PS1 PWROKI 0x62 10 1 Power Supply Digital State State Asserted PSO VINERRO 0x2a 10 0 Power Supply Digital State Predictive Failure Deasserted PS0 VINER
20. er supply and being supplied input voltage chassis LED behavior It is OK ACPI TABLE 3 3 ACPI Sensor Event Description Action ACPI Asserted Host power has been enabled Add to log ACPI DeAsserted Host Power has been disabled Add to log 18 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 Power Budget TABLE 3 4 Sensor Event Description Action SYS VPS UCR Asserted Server module power is over Add to log utilizing chassis power Power Supply Asserted This server module exceeds the Power on of server module will not SYS PWRCTLSTATE available power budget for the work If server module powers on it chassis may be powered off in 30 seconds during BIOS POST Add to log Power Supply DeAsserted There is enough power budget in Allow power on of server module SYS PWRCTLSTATE the chassis to power on the server Add to log module You can now power it on Fans TABLE 3 5 Sensor Event Description Action Fan Predictive Failure A fan module has failed or has No action on server module CMM Fmx FAIL Asserted been removed from the chassis handles LED behavior on chassis and fan modules Fan Predictive Failure A fan module failure has cleared or No action on server module CMM Fmx FAIL DeAsserted has been inserted from the chassis handles LED behavior on chassis and fan modules Chapter 3 Sensor Definitions 19 Other Sensors TABLE 3 6 Sensor State Description SYS SLOTID 0 11 Reflects the server m
21. ice Processor s IP Address Using the CMM on page 5 To Display the Service Processor s IP Address Using the CMM Note This procedure can be used for ELOM as well as ILOM 2 0 and ILOM 3 0 1 Log in to the CMM ILOM CLI 2 Type the command show CH BLn SP network where n is the server module number or chassis slot ID The CMM ILOM displays information about the server module including its IP address and MAC address For example gt show CH BLO SP network CH BLO SP network Targets Properties type Network Configuration Chapter 2 Firmware Update Procedures 5 commitpending Cannot show property ipaddress IPaddress ipdiscovery dhcp ipgateway IPgateway ipnetmask 255 255 252 0 macaddress Macaddress pendingipaddress Paddress pendingipdiscovery dhcp pendingipgateway I Pgateway pendingipnetmask 255 255 252 0 Commands cd set show Determining Your Current Firmware Versions There are three alternate procedures in this section that you can use m Using the CLI Through the Management Ethernet Port on page 6 m Using the CLI Through the Serial Port on page 7 m Using the Web Interface on page 8 Using the CLI Through the Management Ethernet Port See the Sun Blade X6450 Embedded Lights Out Manager Administration Guide for more detailed information on this procedure 1 Connect an RJ 45 Ethernet cable to the NET MGT Ethernet port on th
22. ity Presence Availability State Device Absent CMM PRSNT 0x68 6 0 Entity Presence Availability State Device Present NEM0 PRSNT 0x66 44 2 Chapter 3 Sensor Definitions TABLE 3 7 Complete List of Sensors Continued Sensor Data Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Entity Presence Availability State Device Present NEM1 PRSNT 0x67 44 3 Entity Presence Availability State Device Present PEMO PRSNT 0x64 44 4 Entity Presence Availability State Device Absent PEM1 PRSNT 0x65 44 5 Entity Presence Availability State Device Absent BLn PRSNT where n is the blade number 41 n Entity Presence Availability State Device Present FMn Fx TACH where n is the fan module x is the fan 30 n Fan 5300 0 RPM ok ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Assert
23. k na na na na 708 000 na ucr ucr MB MCH DA0 PRSNT 0x75 32 0 Entity Presence Availability State Device Present MB MCH DA1 PRSNT 0x76 32 1 Entity Presence Availability State Device Present MB MCH DA2 PRSNT 0x77 32 2 Entity Presence Availability State Device Absent MB MCH DA3 PRSNT 0x78 32 3 Chapter 3 Sensor Definitions 33 34 TABLE 3 7 Complete List of Sensors Continued Sensor Data Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Entity Presence Availability State Device Absent MB MCH DA4 PRSNT 0x79 32 4 Entity Presence Availability State Device Absent MB MCH DA5 PRSNT 0x7a 32 5 Entity Presence Availability State Device Absent MB MCH DB0 PRSNT 0x7b 32 6 Entity Presence Availability State Device Present MB MCH DB1 PRSNT 0x7c 32 7 Entity Presence Availability State Device Present MB MCH DB2 PRSNT 0x7d 32 8 Entity Presence Availability State Device Absent MB MCH DB3 PRSNT 0x7e 32 9 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009
24. n 0 1 17 Downloading Firmware File Download the flash image pkg file using these steps 1 Browse to http www sun com download 2 Click View by Category 3 Click X64 Servers and Workstations in the Hardware Drivers area 4 Click the link for the desired server module and software release 8 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 5 Click Download 6 Enter your Username and Password If you do not have a Username and Password you can register free of charge by clicking Register Now 7 Click Accept License Agreement 8 Click the appropriate firmware image file name ilom firmware pkg For example ilom X6450 2 0 3 6 r36158 pkg Flashing the ILOM BIOS Firmware Caution ILOM enters a special mode to load new firmware Note the following requirements 1 The host power must remain off 2 No other tasks can be performed in ILOM until the firmware upgrade is complete and the ILOM is reset To ensure a successful update do not attempt to modify the ILOM configuration or use other ILOM Web CLI SNMP or IPMI interfaces during the flash update process Wait until after the update succeeds before making further ILOM configuration changes The update requires a system server and takes about 20 minutes This is the procedure that actually flashes the firmware replacing the existing images with the new images from the pkg file you downloaded previously During the firmware loading pro
25. odule s chassis slot ID number MB THERMOVRD Asserted Sever module is requesting 100 fan speed from the chassis to cool itself down This is not logged MB THERMOVRD DeAsserted CMM is controlling fan speed This is not logged MB MCH Dxy PRSNT Device Present Device Absent SYS VPS 0 X Watts MB T_VRD1 Degrees Celsius Detects DIMM presence Shows the actual power being consumed by the server module Is used as an ambient sensor for the server module If it exceeds the UNR value the server module host powers down 20 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 Complete List of Sensors TABLE 3 7 Complete List of Sensors Sensor Data Sensor ID ACPI 0x21 Entity ID 7 0 Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete Sensor ID Entity ID Sensor Type Discrete Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted System ACPI Power State System ACPI Power State S0 G0 working SYS PWRCTLSTATE 0x30 7 0 Power Supply Digital State State Deasserted NMIBTN 0x22 7 0 Critical Interrupt SYS SLOTID 0x23 7 0 OEM reserved c0 MB THERMOVRD 0x8d 7 0 OEM reserved c0 Digital State State Deasserted MB Pn PRSNT where n is the power supply number 3 n Entity Presence Availabilit
26. ollowing procedure to recover the BIOS firmware for example if the BIOS image becomes corrupt or if the update process fails 1 Copy the following files to a bootable USB flash device Afudos exe S95 3B16 ROM Note S90 3B16 ROM is an example If you have a later file use it 2 Connect the USB flash device to the USB connector on the dongle 3 Reset the server module 4 Press F8 to enter display a list of bootable devices 5 Select the USB flash device from the list 6 Fun the following command from the DOS prompt Afudos S95 3B16 ROM P B K C X The BIOS is updated and the server module restarts Chapter 2 Firmware Update Procedures 13 Recovering the ILOM Firmware Use the following procedure to recover the ILOM firmware for example if the upgrade fails or if the firmware image becomes corrupt 1 Copy all the files from the Sun Download area or Tools and Drivers CD to a bootable USB flash device The files are located in the BMCrecovery directory on the Tools and Drivers CD They consist of m SOCFLASH EXE m DOS4GW a ilom X6450 number bin Where number is a build number for example 2 0 3 6 r36158 Note Use the binary bin file nota pkg file 2 Set up your server module to respond to POST messages and boot prompts 3 Remove AC power from the system to be flashed 4 Insert the bootable flash drive into the USB port 5 Connect AC power and power on the system
27. on Recoverable na Assertions Enabled Icr ucr Deassertions Enabled Icr ucr MB V_ 3V3 0x10 7 0 Voltage 3 287 0 Volts ok na 2 958 na na 3 616 na lcr ucr lcr ucr MB V_ 5V 0x11 7 0 Voltage 4 921 0 Volts ok na 4 488 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 TABLE 3 7 Complete List of Sensors Continued Sensor Data Lower Non Critical na Upper Non Critical na Upper Critical 5 482 Upper Non Recoverable na Assertions Enabled Icr ucr Deassertions Enabled Icr ucr Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical MB V_ 1V25STBY 0x6f 7 0 Voltage 1 260 0 Volts ok na 1 096 na na 1 373 na lcr ucr lcr ucr MB V_ 1V5B0 0x70 7 0 Voltage 1 490 0 Volts ok na 1 349 na na Chapter 3 Sensor Definitions 29 TABLE 3 7 Complete List of Sensors Continued Sensor Data Upper Critical 1 646 Upper Non Recoverable na Assertions Enabled Icr ucr Deassertions Enabled Icr ucr Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower
28. or ILOM to check the versions of firmware you have See Determining Your Current Firmware Versions on page 6 3 Use the ILOM to download the new versions of firmware See Downloading Firmware File on page 8 4 Use the ILOM to install the new firmware See Flashing the ILOM BIOS Firmware on page 9 Note Alternately you can use the Sun xVM Ops Center 5 Reset the Service Processor See Resetting the Service Processor on page 11 4 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 Getting the Service Processor s IP Address You use the Service Processor SP on your server for various firmware update tasks and you must use its IP address to access it If you do not already know the Service Processor s IP address you must determine it There are several different methods you can use to locate ILOM SPs and their IP addresses 1 DHCP server Refer to the ILOM documentation for your ILOM version for instructions on how to determine the IP address of an SP 2 Linux and Solaris open source nmap command The open source nmap command provides a p port option to scan for port 623 which can be used to quickly detect IPMI enabled devices such as your server s SP on a network For example nmap p 623 10 6 154 1 24 Interesting ports on net address 623 10 6 154 1 24 PORT STATE SERVICE 623 tcp closed unknown 3 Chassis Monitoring Module CMM See To Display the Serv
29. s autorites des Etats Unis l utilisation d unites centrales pour proceder a des mises a jour de produits est rigoureusement interdite LA DOCUMENTATION EST FOURNIE EN L ETAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFACON Sd mon Ca Adobe PostScript Contents Preface v Introduction 1 ILOM 2 0 Features Supported 1 Firmware Update Procedures 3 Overview 3 Using the SP to Update Firmware 4 Getting the Service Processor s IP Address 5 v To Display the Service Processor s IP Address Using the CMM 5 Determining Your Current Firmware Versions 6 Using the CLI Through the Management Ethernet Port 6 Using the CLI Through the Serial Port 7 Using the Web Interface 8 Downloading Firmware File 8 Flashing the ILOM BIOS Firmware 9 Flashing the Firmware with the ILOM Web Interface 10 Flashing the Firmware With the ILOM CLI 11 Resetting the Service Processor 11 Clearing CMOS Settings Optional 12 Recovering the BIOS Firmware 13 Recovering the ILOM Firmware 14 3 Sensor Definitions 17 Entity Presence 17 Power 18 ACPI 18 Power Budget 19 Fans 19 Other Sensors 20 Complete List of Sensors 21 iv ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 Preface The
30. ter 3 Sensor Definitions 31 TABLE 3 7 Complete List of Sensors Continued Sensor Data Sensor ID MB V_ 0V9B1 0x73 Entity ID 7 0 Sensor Type Analog Voltage Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID 0 887 0 Volts ok na 0 806 na na 0 989 na lcr ucr lcr ucr MB V_ 1V9NIC 0x74 7 0 Voltage 1 930 0 Volts ok na 1 709 na na 2 083 na lcr ucr ler ucr SYS VPS 0x8e ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 TABLE 3 7 Complete List of Sensors Continued Sensor Data Entity ID 7 0 Sensor Type Analog Power Unit Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID Sensor Type Discrete States Asserted Sensor ID Entity ID 284 0 Watts o
31. tical 1 978 Upper Non Recoverable na Assertions Enabled lcr ucr Deassertions Enabled lcr ucr Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID MB V_ 1V8STBY 0x6c 7 0 Voltage 1 782 0 Volts ok na 1 617 na na 1 978 na lcr ucr lcr ucr MB V_ 1V2NIC 0x12 Chapter 3 Sensor Definitions 25 TABLE 3 7 Complete List of Sensors Continued Sensor Data Entity ID 7 0 Sensor Type Analog Voltage Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog 1 238 0 Volts ok na 1 074 na na 1 312 na Icr ucr lcr ucr MB V_ 12VCPUn where n is the cpu number 7 n Voltage 12 222 0 Volts ok na 10 773 na na 13 167 na Icr ucr ler ucr MB V_ 12V 0xd 7 0 Voltage ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 TABLE 3
32. y State Device Present Chapter 3 Sensor Definitions 21 TABLE 3 7 Complete List of Sensors Continued Sensor Data Sensor ID MB Pn TCCAT where n is the power supply number Entity ID 3 n Sensor Type Discrete Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical OEM reserved c0 MB T_VRDn where n 0 3 7 0 Temperature 28 0 degrees C ok na na na na na na MB T_DIMMO 0x1b 7 0 Temperature 30 0 degrees C ok na na na 72 000 22 ILOM 2 0 Supplement for Sun Blade X6450 Server Module May 2009 TABLE 3 7 Complete List of Sensors Continued Sensor Data Upper Critical 75 000 Upper Non Recoverable na Assertions Enabled unc ucr Deassertions Enabled unc ucr Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non Recoverable Assertions Enabled Deassertions Enabled Sensor ID Entity ID Sensor Type Analog Sensor Reading Status Lower Non Recoverable Lower Critical Lower Non Critical Upper Non Critical Upper Critical Upper Non