Home

ATCA-1200 Quad AMC Carrier Installation Guide

image

Contents

1. RTM Where to go from here See the ATCA 1200 Quad AMC Carrier Reference for detailed information on the carrier s electrical mechanical environmental and software aspects Additional software information is covered in the Ethernet Switching Software Reference You should also set passwords for the root and the admin users and create user accounts for those who do not require administrative privileges See the ATCA 7200 Quad AMC Carrier Reference for more information Where to get more product information Please visit the RadiSys Web site at www radisys com for product information and other resources Downloads manuals release notes software etc are available via the Technical Support Library product links at www radisys com support or the product pages at www radisys com products
2. CH If you are not at the appropriate prompt see Connect to an external computer and the network on page 4 for instructions on how to get there 2 Follow these steps to enable a specific port other than the default port of 0 1 A Enter this command configure B Enter the specific port interface number to enable The s variable represents the specified slot or bay The p variable represents an individual port within the group of ports for the specified slot or bay interface lt s p gt Where s and p have the following values ATCA 6000 backplane slots s 0 p 1 4 ATCA 6006 backplane slots s 0 p 1 4 AMC ports s 1 4 p 1 5 Internal ports s 5 p 1 2 RTM S 6 p 1 2 C Enter this series of commands to enable the port d no shutdown b exit 3 Follow these steps to disable the default port of 0 1 A Enter this command configure B Enter the port number to disable For the default port this number is 0 1 interface 0 1 C Enter the next two commands to disable the specified port d shutdown b exit D Enter the next two commands to return to the ATCA 1200 prompt a exit b exit If you are asked to save changes enter y for yes or n for no If you choose y for yes this configuration will be saved as the startup configuration 4 Enter the exit command again to log off the carrier If you are connected to the carrier using the RTM disconnect the cable from the serial port or the Ethernet maintenance port on the
3. PROMENTUM QUAD AMC CARRIER INSTALLATION GUIDE ATCA 1200 ie This document describes how to install and to set up the Promentum ATCA 1200 Quad Advanced Mezzanine Card AMC carrier 007 02570 0000 September 2007 Follow ESD precautions During installation follow proper electrostatic discharge procedures when handling the carrier and electrical equipment WARNING This product contains static sensitive components and should be handled with care Failure to employ adequate antistatic measures can cause irreparable damage to components Handle this product only when wearing a grounded wrist strap at a grounded work area Additional precautions and ESD information are provided at www radisys com esd Do not remove the carrier from its ESD shielding bag until a step instructs you to do so Failure to follow ESD precautions may cause hardware damage Prepare for installation Installation of the carrier requires the following An AdvancedTCA ATCA shelf such as a RadiSys ATCA 6000 or ATCA 6006 shelf Adequate ventilation for the shelf To access the carrier through an external computer you may need the following An optional rear transition module RTM designed for the carrier A 9 pin D shell to RJ 45 serial port cable A standard crossover Ethernet cable Install AMCs AMCs are typically pre installed in the carrier at the factory Note If you are installing your own AMCs verify they ar
4. e compatible with the carrier and listed with UL Check the specified requirements for form factor power cooling and connectors in the ATCA 1200 Quad AMC Carrier Reference and in the documentation that came with the AMCs Follow ESD precautions when installing AMCs on the carrier see information above Copyright 2007 by RadiSys Corporation All rights reserved RadiSys is a registered trademark and Promentum is a trademark of RadiSys Corporation Linux is a registered trademark of Linus Torvalds AdvancedTCA and ATCA are registered trademarks of PCI Industrial Computer Manufacturers Group Procomm Plus and Symantec are registered trademarks of Symantec Corporation All other trademarks registered trademarks service marks and trade names are the property of their respective owners Install the RTM optional An RTM designed for the carrier can be used for I O access The RTM can be installed at any time but it is easier to do so before installing the carrier in the shelf This section describes the RTM being installed before the carrier Preparation Before installing the RTM RTM for carrier Verify it is compatible with the carrier Follow ESD precautions See page 1 for more information Determine which front node slot in the shelf you plan to use for the carrier The RTM will be installed in the corresponding rear slot For example if you intend to install the carrier in front physical slot number 3 install the RTM in
5. erify you are at this prompt ATCA 1200 If you are not at the appropriate prompt see Connect to an external computer and the network on page 4 for instructions on how to get there 2 Enter this command to access the Ethernet command line interface ethernet This results in the ATCA 1200 Eth prompt 3 Enter this command to show the status of the ports show port all View the status information of the ports to see which ports are enabled If needed press the space bar to view more of the list By default Base port 0 1 is enabled 4 Proceed to the applicable section or step To change which port is enabled see Change the enabled port on page 7 To keep the default settings continue with step 5 5 Enter the exit command to return to the ATCA 1200 prompt If you are asked to save changes enter y for yes or n for no If you choose y for yes this configuration will be saved as the startup configuration 6 Enter the exit command to log off the carrier If you are connected to the carrier using the RTM disconnect the cable from the serial port or the Ethernet maintenance port on the RTM Change the enabled port Note RadiSys recommends only having one port enabled at a time on the carrier if the platform configuration has two switches with interconnected switching domains A connection between the Base Ethernet switching domains is enabled by default on RadiSys switches 1 Verify you are at this prompt ATCA LA2A00 E
6. isplay check the cabling and verify the terminal emulator settings are correct You can also check the LED states on the carrier If necessary press the reset button and see if any text is displayed If text is displayed it may provide some hints as to what else to check Enter admin at the prompt Verify that you receive a welcome message and a prompt showing ATCA 1200 From this prompt you can perform diagnostic and verification procedures To log off the carrier at any time enter the exit command See the ATCA 1200 Quad AMC Carrier Reference for information on diagnostic and verification procedures Disconnect the serial port cable from the RTM when you are through performing the diagnostic and verification procedures RTM front Ol Ethernet maintenance port LMP ETH Serial port LMP SER aren 200 5050 a 5060 LE si Teet D Bs IOlOl RESET Power LED Connect to the Ethernet maintenance port ie Connect a crossover Ethernet cable between the RJ 45 Ethernet maintenance port labeled LMP ETH on the RTM and the RJ 45 Ethernet port on a Linux host computer that is connected to your network Configure the host computer to a subnet IP address of 10 0 0 x For the x variable select a value from the range 2 254 for example 10 0 0 2 to 10 0 0 254 Set the netmask to 255 255 255 0 From the host computer use a Telnet or an SSH connection to access the carrier s defa
7. ng for Shelf Manager Solid blue Ready for hot swap Short blink Preparing for removal Off Normal operation Connect to an external computer and the network Connect to an external computer and the network using one of these methods with the optional RTM designed to mate with the carrier with Telnet or SSH via the backplane Ethernet interfaces Connect with the RTM This section assumes you have installed the optional RTM as described on page 2 The Quad AMC carrier can be accessed by an external computer through the serial and the Ethernet maintenance ports on the RTM Use the serial port to perform diagnostic and verification procedures Use the Ethernet maintenance port to connect the carrier to the network and to perform configuration procedures Connect to the serial port l Connect the serial port cable by plugging one end into the RJ 45 serial port labeled LMP SER on the RTM For a description of the serial port cable pinouts see the ATCA 1200 Quad AMC Carrier Reference Connect the cable s other end to the COM1 or the COM2 serial port of an external computer such as a laptop Start a terminal emulator application such as Procomm Plus or minicom from the operating system on your computer or laptop Specify 115200 baud 8 data bits no parity one stop bit and no hardware or software flow control Press the Enter key to get the ATCA 1200 login prompt If the ATCA 1200 login prompt does not d
8. rear physical slot number 3 Remove the airflow management panel installed in the rear node slot Note If you are using another vendor s RTM check the RTM s documentation for installation instructions or precautions Installation 1 Follow ESD precautions and make sure you are adequately grounded before handling the RTM i s f Y 2 Remove the RTM from its antistatic bag 3 Open both ejector latches on the RTM 4 Slide the RTM into the empty rear slot on the shelf 5 Close both ejector latches Push in the thumbscrews and tighten 6 Install the carrier see below 7 After installing the carrier verify the RTM s power LED is green the RTM gets its power through the front module 8 Use the shelf management software to verify the RTM and the corresponding front module are available as resources and operating correctly Install the carrier 1 This section assumes you are installing the carrier in an ATCA shelf and the shelf power is on The ATCA shelf architecture lets you insert and remove the carrier from the shelf without powering down the system 2 Follow ESD precautions and make sure you are adequately grounded before handling the carrier see page 1 Remove the carrier from its antistatic bag Open both ejector handles outward at the same Open ejector handles time Slide the carrier into one of the node slots on the shelf If correctly aligned the edges of the carrier will fi
9. rrier SCM 2 Configure the IP address of the host computer using the following 10 2 lt chassis gt x The lt chassis gt parameter represents the shelf address the physical location of the shelf within a central office For the x variable select a value from the range 17 254 for example 10 2 lt chassis gt 17 to 10 2 lt chassis gt 254 Set the subnet to 255 255 0 0 for the eth1 0 interface 3 From the host computer use a Telnet or an SSH connection to access the eth1 0 interface on the carrier The static IP address is 10 2 lt chassis gt lt slot gt The lt chassis gt parameter represents the shelf address and the lt slot gt parameter represents the carrier s location in the shelf The ATCA 1200 login prompt for the carrier will display If the prompt does not display verify the Telnet or the SSH connection to the static IP address is correct 4 Login as admin to get the ATcA 1200 prompt From this prompt you can perform configuration procedures To log off the carrier at any time enter the exit command Note To connect to the Linux shell on the carrier log in as root and enter ifconfig to view eth configuration settings 5 Disconnect the Ethernet cable from the Base Ethernet port on the module through when you are done performing the configuration procedures Verify Ethernet switch operation Use these steps to view port status and to enable ports on the Ethernet switch View port status 1 V
10. t within the narrow guide rails of the shelf and the carrier will mate with the alignment receptacles of the corresponding compatible RTM if one is installed Once the carrier is inserted all the way into the shelf simultaneously close both ejector latches inward This will seat the carrier s connectors into the shelf s backplane The hot swap H S LED flashes until the carrier is fully powered see Front panel LED indicators below Once powered the H S LED will turn off and the Power LED will become green If the H S LED remains solid blue or keeps flashing after the carrier is inserted it indicates the installation may have failed Please see the ATCA 1200 Quad AMC Carrier Reference for information on i Slide hot swap x troubleshooting LED states Pee au ara handie and pull handle out Secure the carrier in its slot by hand tightening the two fastening screws on each end of the carrier s front panel If the optional RTM is installed verify the RTM s power LED Is green Use the shelf management software to verify the carrier and the RTM are available as resources and are operating correctly Front panel LED indicators Label LED Definition Color States OOS LED 1 Out of service Red or amber Out of service Off Normal operation PWR LED 2 Power Amber Application defined Green Power good APP LED 3 Application Amber Application defined Green Application defined H S H S Hot swap Long blink Searchi
11. ult IP address 10 0 0 1 port 23 The ATCA 1200 login prompt for the carrier will display lf the ATCA 1200 login prompt does not display verify the Telnet connection to the carrier s IP address is correct Log in as admin to get the ATCA 1200 prompt From this prompt you can perform configuration procedures To log off the carrier at any time enter the exit command Note To connect to the Linux shell on the carrier use either a serial port or a Telnet connection After connecting log in as root and enter ifconfig to view ethO configuration settings Disconnect the Ethernet cable from the RTM when you are through performing the configuration procedures Connect with Telnet or SSH via the backplane Ethernet interfaces l Connect a crossover Ethernet cable between the RJ 45 Ethernet port on a module that has access to the Base Ethernet interface and the RJ 45 Ethernet port on a Linux host computer that is connected to your network Examples of modules that have access to the Base Ethernet interface include CPU modules and switch and control modules like the RadiSys ATCA 2210 SCM For example if the ATCA 2210 SCM is installed on the shelf you can connect to the Base Ethernet SFP port e g port 1 6 on the front panel Front panel Base port e g 1 6 Base Fabric Ethernet Ethernet switch switch Base backplane link eth1 interface Local management Local management processor processor ATCA 1200 ATCA 2210 Quad AMC Ca

Download Pdf Manuals

image

Related Search

Related Contents

UBZ-LJ8 - Onedirect  Memorex Clock Radio Mini Alarm  Maintenance Manual MM-2075  manual de servicio maquina vendedora de refrescos  LRP Hyper Pack 4600  Table of Content - Mul-T  Maroo MR-UC8001  Samsung BCD-290WNSIWW1 用户手册  

Copyright © All rights reserved.
Failed to retrieve file