Home

Xpert/XLite Voice Modem Users Manual

image

Contents

1. a le Xpert XLite Voice Modem S a Users 8080 0005 1B amp 2B SERIE OPERATIONS amp MAINTENANCE MANUAL Part No 8800 1178 RevA January 2011 Sutron Corporation 22400 Davis Drive Sterling VA 2016 Sutron Corporation Xpert XLite Voice Modem Users Manual 8800 1178 RevA 01201 1 Sutron Voice Modem Operation Manual Models 8080 0005 1B and 2B TABLE OF CONTENTS 0 Benet eee eS NEE eee oe eee ae ee 1 JuUMpersvand Connections massassa east ovate 2 DB 9 serial CONNECtOR Neate 2 Extermal power and grounding ceessncesnorarsisnrini edad 2 Recommended Jumper 35 1 3 Operation with the Xpen XLite ss need 4 Operation with Xpert NIFC option 2 model 6 Connection to BK rebel tecsaacadaarabarteas 6 Operation witha 7 Operation with SUTRON Sensors and loggers SDR Bubbler Monitor
2. G Power supply ground Should be at the same potential as the RS 232 ground Pin 5 of the DB 9 Supply voltage 5 to 16 VDC Power can either be supplied via this terminal or via pin 9 of the DB 9 connector If power is supplied from both modem will pull power from the higher voltage Note If using the two mounting screws on the rear of the modem to provide the earth ground for the unit the screws threads should be 6 32 The two screws have a separation of 3 inches In addition the screws should protrude no more than on half inch into the case Note While the internal transient protection provides a high degree of ruggedness to the unit it is not intended to replace the heavy duty external telephone line transient protection that is needed in more remote locations Sutron Corporation 22400 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com Sutron Corporation Xpert XLite Voice Modem Users Manual Recommended Jumper Settings 8800 1178 RevA 07 2011 JUMPER JUMPER Function FACTORY XPERT SDR 8210 POSITION DEFAULTS XLITE MONITOR J5 DSR 1 2 DSR CD 2 3 DSR DSR normal X x J4 Wake up 1 2 Wake on RTS 2 3 Wake on DTR J3 Pin 9 use 1 2 RI out 2 3 Power in Sutron Corporation Note Sutron s products do not require the RI signal and J3 should be left in the factory default position of
3. 2 3 If using the modem with a device software that requires RI to announce an incoming call change J3 to position 1 2 22400 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com Sutron Corporation Xpert XLite Voice Modem Users Manual 8800 1178 RevA 01201 4 Operation with the Xpert XLite You must configure the Xpert XLite in order to use the modem connected to one of the serial ports The modem can connect to any of the serial ports however Sutron recommends using COM3 COM2 is typically used for SATLINK and COM1 is typically used for a direct laptop connection From the factory the Xpert and XLite will be configured to supply 5V from pin 9 of COM 3 and the modem will be configured to be powered through the DB 9 This arrangement will make it possible to use one RS 232 cable to both power the modem and to communicate Refer to the Xpert manual for details if power needs to be configured on for the comport or for more detailed instructions on the following steps The following example assumes the modem will be connected to COM3 The first thing to do is to edit the autoexec bat file to support the modem This is done by adding or editing the line where the remote program is run Note you create or edit the file on your PC and then use XTERM to transfer the file to the Xpert Adding the text voice3 115200 tells remote that there will be a Sutron modem connected to COM3 and to use a baud r
4. 0 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com Sutron Corporation Xpert XLite Voice Modem Users Manual 8800 1178 RevA 072010 5 For voice mode Select add additional voice files for specfic sensors Prefix and units Suffix Edit the dial out message for alarms Edit the dial in message Example dial in message Speak prefix data suffix and alarm status for three sensors then to hang up SpeakPhrase Hello welcome to the Sutron xpert Pause 2 0 SpeakTag RAIN Pause 2 0 SpeakTag ELEVATION Pause 2 0 SpeakTag LEVEL Hangup For data mode Nothing else needs configured Sutron Corporation 22400 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com Sutron Corporation Xpert XLite Voice Modem Users Manual 8800 1178 RevA 07200 6 Operation with Xpert NIFC option 2 model When using the NIFC version 2 the modem becomes an interface between an Xpert and a radio It allows an operator to remotely wake up an Xpert Station with a remote Radio with DTMF keypad The operator enters the unique station id of interest and then listens to a pre programmed set of sensor values The modem decodes the DTMF tones and provides the speech playback capabilities for the Xpert Station With this option the modem DOES NOT operate as a normal phone line modem and SHOULD NOT be connected to a phone line The validation of the Station ID and the configuration of the sens
5. DTR and RTS for power up signal Jumper to force DSR output to follow CD Capability to be powered over RS 232 cable Wide input power supply of 5 to 16V Digital Line Guard for protection if accidentally connected to digital telephone line Built in transient protection Sutron Corporation 22400 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com Sutron Corporation Xpert XLite Voice Modem Users Manual 8800 1178 RevA 01201 2 Jumpers and Connections DB 9 serial connector The modem is designed with a DB9 Female DCE connection This allows the modem to be connected directly to DTE devices such as the Xpert and XLite or a PC using a straight cable Jumpers allow the DTE device to provide power to the modem through pin 9 of the DB9 connector For connection to devices that can not provide power on pin 9 there is also separate power connector Pin Name Direction 2 RD Out 3 TX In 4 DTR Out 5 GND GND 6 DSR Out 7 RTS In 8 CTS Out 9 RI or PWR IN Out or In set by J3 External power and grounding The modem has a three position terminal block to provide easy connections for power and for earth grounding of the modem Label Function Earth ground ground for internal transient protection Grounding can also be achieved by mounting the modem to a grounded metal plate via the two mounting screws on the back of the modem
6. ate of 115200 A typical autoexec bat appears as follows windows remote com1 115200 voice3 115200 flash disk xpert OPTIONAL For advanced customization of how the modem works create an initialization file for the modem e g scom3 ini The modem by default is initialized so that when it powers up it will not echo characters will not provide result codes and will ignore DTR Remote exe will send the contents of the init file to the modem when it starts A typical init file for the Sutron modem is ATSO 1 ATE0Q1 amp D0 amp W Be sure there is a CR at the end of the last line in the file or the program will ignore the line Again you create or edit the scomx ini file on your PC and then use Xterm to transfer the file to the Xpert The meaning of each setting is S0 1 answer on first ring don t echo characters Q1 don t send result codes amp DO ignore DTR amp W save settings into profile In the Setup of the Xpert Xlite add a COMS TAG to each data point that is needed optionally add an ALARM block in front of the COMS TAG to trigger and send alarm data Edit COMS TAG ALARMS with appropriate data Next set up the Xpert Xlite control panel COMS entry Select Coms and change COM3 to VOICE Once the VOICE is selected for COM3 a plus sign will allow the VOICE3 to be configured Set answer mode number of rings and language Set phone number s number of redials and the redial delay for alarms Sutron Corporation 2240
7. ccccececseeeeeceeeeeeeeeeseeaeees 7 POWEN ON E sana ceessandaaarenarcens 7 Testing troubleshooting the modem with an Xpert or 8 Compliance IM Ornato sisirin iiiad aaa aiaa a a aad EA 9 6 68 5 68 68 10 selecting County COdES A RAAT TTA 14 Overview The 8080 0005 1B is a telephone modem designed for voice and data communications with Sutron s data recorders The 8080 0005 2B is a special version designed to interface to a radio instead of a telephone line and requires the Xpert XLite to be configured for fire weather operations The 8080 0005 offers the features commonly offered by standard modern modems along with some special power saving features These features include RS232 interface baud rate up to 115 200 V 34 33 6 kbps data sending and receiving Voice playback and record DTMF decode 40 C to 60 C extended operating temperature V 42 MNP 2 4 and 10 EC error correction V 42bis and MNP 5 data compression Auto power up on ring with time out Power up LED TX RX CD leds Jumper to select between
8. e modem s perspective For more in depth details on the specifics for each product when working with a modem please refer to appropriate product manual The default settings from Sutron for the modem will typically work If the settings have been changed and need to be reset connect the modem to a PC see above or other device and issue these commands to the modem ATSO 1 ATE0Q1 amp D0 amp W This is what the commands mean AT amp F set to factory defaults S0 1 answer on first ring don t echo characters Q1 don t send result codes 800 ignore DTR amp W save settings into profile A null modem cable is needed between the device and the modem since they are both configured as DCE devices If the null modem cable routes pin 9 through from end to end you can power the modem from the device but most null modem adapters leave pin 9 disconnected In that case just connect the power 5V 16V DC to the power connector Note this can be done even if the cable routes power through pin 9 The modem will utilize which ever is providing the higher voltage The modem also must be configured to power up in RTS instead of DTR and to output CD on the DSR pin Set J4 to pins 1 2 to have the modem wake up on RTS Set J5 to pins 1 2 to route CD out the DSR pin Auto power on mode The modem enters a power down mode when DTR is low J3 in default 2 3 position If in the 1 2 position then RTS In this mode the power is turned off to the mode
9. ephone company may temporarily disconnect service The telephone company may make changes in its technical operations and procedures If such changes affect the compatibility or use of this device the telephone company is required to give adequate notice of the changes If the telephone company requests information on what equipment is connected to their lines inform them of the following a The telephone number and the device it connected to b The Ringer Equivalence Number REN 0 7B The device uses an RJ11 type jack d The FCC Registration Number US 3A4M507B336SM T W The REN is used to determine the number of devices that may be connected to the telephone line Excessive REN on a telephone line may result in devices not ringing in response to an incoming call In most but not all areas the sum of the REN should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as determined by the total REN contact the telephone company The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or any other electronic device including fax machines to send any message unless such message clearly contains in a margin at the top or bottom of each transmitted page or on the first page of the transmission the date and time it is sent and an identification of the business or other entity or other individual sending the message and the telephone number of the sending
10. m thus conserving the 360 mW that the modem would otherwise use When a ring is detected on the phone line the power is automatically turned on to the modem This power on sequence takes about 3 seconds at which time the modem will be fully active Typically the modem will then answer the phone on the next ring SO 1 to make 8 connection with the calling modem Sutron Corporation 22400 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com Sutron Corporation Xpert XLite Voice Modem Users Manual 8800 1178 RevA OY2001 8 Testing troubleshooting the modem with an Xpert or XLITE If the modem does not seem to be working with an Xpert try these following steps If any tests fail contact customer service for further help If the modem does not power up Check that the jumpers are configured for the correct input power and that the power is making it to the modem To bypass the Xpert and see if the modem powers up do the following Apply 12V power to the modem Modem should turn on and light up the power LED for up to two minutes and then power off If the modem does not answer an incoming call Check phone line using a handset Check all cables between modem and Xpert Via a P C and terminal program HyperTerminal connected to Xpert com1 issue the command type autoexec bat Verify that remote exe is being set for a modem connection on the correct com port I E a line that states windows re
11. machine or such business other entity or individual The telephone number provided may not be a 900 number or any number for which charges exceed local or long distance transmission charges This equipment must not be used on party lines Connection to party line service is subject to state tariffs Contact state public utility commission for information In order to program this information into your fax machine or fax modem consult your fax machine s user s manual for setup instructions Industry Canada CS 03 IC 2377A 11813 This product meets the applicable Industry Canada technical specifications Le present materiel est conforme aux specifications techniques applicables d Industrie Canada Sutron Corporation 22400 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com Sutron Corporation Xpert XLite Voice Modem Users Manual 8800 1178 RevA 072010 10 Specifications Features Features e RS232 interface baud rate up to 115 200 84 33 6 kbps data sending and receiving Voice playback and record DTMF decode 40 C to 60 C extended operating temperature V 42 MNP 2 4 and 10 EC error correction V 42bis and MNP 5 data compression Auto power up on ring with time out Power up LED TX RX CD leds Jumper to select between DTR and RTS for power up signal Jumper to force DSR output to follow CD Capability to be powered over RS 232 cable Wide input power supply of 5 to 16V Digital Line Guard for p
12. mote exe com1 115200 voice3 115200 Make sure remote exe is running by issuing the Status command The Xpert should report that remote is running on COM1 and COMx where x is the port you have connected to the modem Disconnect the modem from the Xpert Connect a P C with a terminal program to the modem and apply power via the external power connector Issue an AT amp V command to the modem The modem should respond with the current profile and the stored profiles Verify modem active profile and stored profile is set to 5051 Q1 amp DO Disconnect modem Reconnect modem to Xpert Dial into the modem either via a phone line or line simulator See prompt to login or flash disk if using a terminal program or see login menu if using Xterm If the modem picks up the phone line but does not speak Check Dial in message from Xpert Xlite Sutron Corporation 22400 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com Sutron Corporation Xpert XLite Voice Modem Users Manual 8800 1178 RevA 01201 9 Compliance Information The Federal Communication Commission FCC has established rules which permits this device to be directly connected to the telephone network If this device is malfunctioning it may also be causing harm to the telephone network This device should be disconnected until the source of the problem can be determined and until repair has been made If this is not done the tel
13. ng 3D France is the current country selected OK Note When a country code is changed you do not have to store the setting with the AT amp W command The modem will automatically store the setting when the AT GCI command is issued It will remain in effect until overwritten with a new selection To view which countries are available in the modems firmware enter AT GCl lt CR gt The modem will display all of the possible two digit country codes available Country Code Country Code Country Code Australia 09 Poland 8A Austria OA India 53 Portugal 8B Belgium OF Ireland 57 South Africa 9F Brazil 16 Singapore 9C Italy 59 Spain AO China 26 Japan 00 Sweden AS Korea 61 Switzerland A6 Denmark 31 Malaysia 6C Taiwan FE Finland 3C Mexico 73 United Kingdom B4 France 3D Netherlands 7B United States B5 Germany 42 Hong Kong 50 Norway 82 TBR21 FD Sutron Corporation 22400 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com
14. ors to read back are all handled by the Xpert application software Refer to the appropriate Xpert or 9210 Users manual for detailed set up instructions The modem jumpers should be set to connect to an Xpert 566 jumper table above to operate with the Xpert and BK radio Connection to BK Radio The 8080 0005 2 can be connected to a BK radio A drawing of the RJ11 connector on the modem and the connections to the radio are shown below D T neg DEN Ec3 38s Q ror NYOOO RJ 11 BK Radio Radio Ext Speaker Signal direction connector Accessories Connector 1 2 Black T2 No Connect No Connect No Connect 3 Red Ring 3 ground Ground reference 4 Green Tip Ext Speaker signal Audio into modem 5 Yellow R2 4 mic audio Audio out of modem 6 Sutron Corporation 22400 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com Sutron Corporation Xpert XLite Voice Modem Users Manual 8800 1178 RevA 01201 T Operation with a PC Connect modem to external power 5 to 16V DC since a PC does not supply power on pin 9 Connect to a standard serial port on a PC With the exception of the auto power on mode explained below the modem will operate as a standard modem Operation with SUTRON Sensors and loggers SDR Bubbler Monitor The instructions here are the general instructions for configuring and connecting the 8080 0005 1B modem to these products written from th
15. rotection if accidentally connected to digital telephone line Built in transient protection Agency Approvals 8080 0005 1B e FCC68 amp IC CS 03 registered TBR21 ETSI TS103 021 1 2 3 Countries supported by the existing firmware Australia Austria Belgium Brazil Canada China Denmark Finland France Germany Hong Kong India Ireland Italy Japan Korea Malaysia Mexico Netherlands Norway Poland Portugal Singapore South Africa Spain Sweden Switzerland Taiwan UK US and TBR21 Generic Ratings 25 C Parameter Min Max Units Tip Ring Current Continuous 10 120 mA Dielectric Withstanding Voltage 1500 VRMS Operating Temperature 40 60 C Voltage Requirement 4 75 16 V Power Consumption 500 mW Transmit amp Receive Level 10 Tx 43 Rx dbm Sutron Corporation 22400 Davis Drive Sterling VA 20164 703 406 2800 www sutron com sales sutron com Sutron Corporation Xpert XLite Voice Modem Users Manual 8800 1178 RevA 072010 1 Selecting Country Codes Setting the modem s country code is done by with the GCI command To change to one of the 30 available countries issue the AT GCl n command where n is one of the two digit country codes Example AT GCl 3D lt CR gt Meaning Change country code to France OK Meaning The modem has accepted the command and is now configured for operation in France AT GClI lt CR gt Meaning Display current country code GCl 3D Meani

Download Pdf Manuals

image

Related Search

Related Contents

~TWーNBーRD  Instrucciones de servicio  Operating Instructions - Manuals, Specs & Warranty  OSD8224 OM  Calibration guide for the UNIPAR SL 700 Laser Speed  User Manual  株式会社アドバンスコープ インターネット接続サービス契約約款 第1章 総  Policy Number: 4:10    CEREC / inLab MC XL  

Copyright © All rights reserved.
Failed to retrieve file