Sun Storage 2500-M2 Arrays Site Preparation Guide
Contents
1. are generated by normal operation of the unit TABLE 2 4 lists the environmental conditions in which the array is designed to operate TABLE 2 4 Controller Tray Temperature Parameter Requirement Operating range both cabinet and subsystem Maximum rate of change Storage range Maximum rate of change Transit change Maximum rate of change 50 F to 104 F 10 C to 40 C 50 F 10 C per hour 14 F to 122 F 10 C to 50 C 59 F 15 C per hour 40 F to 140 F 40 C to 60 C 68 F 20 C per hour Tf you plan to operate a system at an altitude between 3280 feet to 9842 feet 1000 meters to 3000 meters above sea level lower the environmental temperature 3 3 F 1 7 C for every 3280 feet 1000 meters above sea level Humidity TABLE 2 5 lists the relative humidity ranges of the controller tray TABLE 2 5 Humidity noncondensing Parameter Specification Operating range both cabinet and subsystem Storage range Transit range Operating gradient Storage gradient 20 to 80 noncondensing 10 to 90 5 to 90 50 F 10 C per hour maximum 59 F 15 C per hour maximum Chapter 2 Sun Storage 2500 M2 Arrays Specifications 7 TABLE 2 5 Humidity noncondensing Parameter Specification Transit gradient 68 F 20 C per hour maximum Maximum dew point 79 F 26 C Maximum gradient 10 per hour Altitude TABLE 2 6 lists the altitude specifications f
2. nominal input voltage Power Cords and Receptacles Sun Storage 2500 M2 Arrays are shipped with either two AC power cords or two DC power cords per tray depending on the configuration ordered AC Power Cords Each AC power cord connects one of the power supplies in a tray to an independent external AC power source such as a wall receptacle or a UPS If you have a cabinet with internal power cabling such as a ladder cord you do not need the AC power cords that are shipped with the controller drive tray Chapter 2 Sun Storage 2500 M2 Arrays Specifications 11 DC Power Connector Cables Each 48 VDC power connector cable plugs into the DC power connector on the back of the controller tray The three source wires on the other end of the power connector cable connect the tray to centralized DC power plant equipment typically through a bus bar above the cabinet Caution A qualified service person is required to make this DC power connection according to NEC and CEC guidelines Caution Risk of electrical shock This unit has more than one power source To remove all power from the unit all DC MAINS must be disconnected by removing all power connectors from the power supplies Two optionally four DC power connector cables are provided with each controller or expansion tray Two DC power connectors are on the back of each tray s DC power supply if additional redundancy is required Note It is not mandatory that
3. not block or cover the openings of your product Never place a product near a radiator or heat register Failure to follow these guidelines can cause overheating and affect the reliability of your product Air cools the system cabinets from front to back Air enters at the front circulates and is expelled at the back of the cabinet The front and back door clearances provide sufficient space for cooling See Chapter 2 for specific clearance specifications Chapter 1 Planning for the Installation 3 Site Preparation Guide August 2011 CHAPTER 2 Sun Storage 2500 M2 Arrays Specifications This chapter describes the physical environmental and electrical requirements for the Sun Storage 2500 M2 Arrays It contains the following sections Dimension and Weight Specifications on page 6 Environmental Requirements on page 7 Electrical Requirements on page 9 Dimension and Weight Specifications The floor space at the installation site must be strong enough to support the combined weight of the cabinet controller trays expansion trays and associated equipment The site also requires sufficient space for installation operation and servicing the arrays and sufficient ventilation to provide a free flow of air to the unit The total weight of an expansion tray depends on the number of drives installed TABLE 2 1 provides the physical dimensions and weight of the array TABLE 2 1 Dimensions
4. page 2 Note Do not make mechanical or electrical modifications to the equipment Oracle Corp is not responsible for regulatory compliance of a modified product Handling Precautions Ensure that all surfaces this system will move over can withstand this load 1 Caution A fully populated cabinet can weigh in excess of 1500 pounds 682 kg The cabinet is equipped with wheels so you can move it Use enough personnel when moving the cabinet especially on sloped loading docks and ramps to gain access to a raised computer room floor Move the cabinet slowly and deliberately and make sure that the floor is free from foreign objects and cables that the cabinet could roll over A Caution To avoid injury wear protective footwear when moving a system Secure Installation Requirements To minimize personnel injury in the event of a seismic occurrence you must securely fasten the cabinet to a rigid structure extending from the floor to the ceiling or from the walls of the room in which the cabinet is located Install the cabinet on a level surface At each corner on the base of the cabinet are adjustable nonskid pads Extend these pads when the cabinet is installed to prevent the cabinet from rolling Do not use these pads to level the cabinet Placement of a Product Allow enough room surrounding the cabinet for access to the cabinet and arrays for maintenance Site Preparation Guide August 2011 Caution Do
5. the second DC power connection on the array s DC power supplies be connected The second DC power connection is provided for additional redundancy only and may be connected to a second DC power bus Battery Life For a fully rated battery backup unit BBU battery life cell limitations are listed in TABLE 2 12 TABLE 2 12 Battery Life Specifications Operating 50 F to 95 F 10 C to 35 C Storage 14 F to 113 F 10 C to 45 C up to three months Transit 4 F to 140 F 20 C to 60 C up to seven days 12 Site Preparation Guide August 2011 APPENDIX A Configuration Worksheets Use the worksheets in this appendix to help you collect the information you need to perform the installation TABLE A 1 lists the information you need to collect to configure the array TABLE A 1 Sun Storage 2500 M2 Arrays Configuration Worksheet Controller A MAC address Controller B MAC address Controller A IP address Controller B IP address Management host IP address Network mask Name server domain name IP address of the domain name server DNS Gateway IP address Email notification address 13 TABLE A 2 lists the information you need to collect for each data host connected to Sun Storage 2500 M2 Arrays TABLE A 2 Sun Storage 2500 M2 Arrays Data Host Information Host name Vendor Model Operating system Patch Service p
6. Sun Storage 2500 M2 Arrays Site Preparation Guide amp Sun Part No E20737 02 en August 2011 Copyright 2011 Oracle and or its affiliates All rights reserved The Sun Storage 2500 M2 Arrays Site a age Guide describes facilities and system requirements for in stalling Sun Storage 2500 M2 Arrays Follow the guidelines as outlined in this document when planning your installation This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws Except as expressly permitted in your license agreement or allowed by law you may not use copy reproduce translate broadcast modify license transmit distribute exhibit perform publish or display any part in any form or by any means Reverse engineering disassembly or decompilation of this software unless required by law for interoperability is prohibited The information contained herein is subject to change without notice and is not warranted to be error free If you find any errors please report them to us in writing If this is software or related software documentation that is delivered to the U S Government or anyone licensing it on behalf of the U S Government the following notice is applicable U S GOVERNMENT RIGHTS Programs software databases and related documentation and technical data delivered to U S Government customers are commercial comp
7. ack Number of HBAs HBA World Wide Name WWN HBA model HBA driver 14 Site Preparation Guide August 2011
8. and Weight Components Height Width Depth Weight Maximum Weight Emptyt Controller tray 3 4 in 8 64 cm 19 in 48 26 cm 21 75 in 55 25 cm 59 52 Ib 27 kg 41 01 Ib 18 60 kg Expansion tray 3 4 in 8 64 cm 19 in 48 26 cm 21 75 in 55 25 cm 57 98 Ib 26 3 kg 39 46 Ib 17 9 kg Maximum weight indicates a controller tray with all of its drives and other components installed Because drive weights can vary this value can vary from the value specified as much as either 0 66 Ib 0 3 kg times the maximum number of drives per controller tray for 3 5 in SATA drives or 0 18 Ib 0 08 kg times the maximum number of drives per controller tray for 2 5 in SATA drives Empty weight indicates a controller tray with the controller modules the power fan modules and the drives removed TABLE 2 2 provides the weight for array components TABLE 2 2 Controller Tray Component Weight Component Weight Controller module 4 70 Ib 2 131 kg Power fan module 5 51 Ib 2 5 kg 2 5 in SATA drive 0 66 Ib 0 3 kg 3 5 in SATA drive 2 2 Ib 1 0 kg TABLE 2 3 Controller Tray Shipping Weight Height Width Depth 9 5 in 24 13 cm 25 in 63 50 cm 23 in 58 42 cm Controller tray with twelve 3 5 in drives Site Preparation Guide August 2011 Environmental Requirements This section describes the environmental conditions that are prerequisite to installing the unit and heat conditions that
9. and wiring AC power requirements DC power requirements and power cord routing instructions Site Wiring and Power The controller tray uses wide ranging redundant power supplies that automatically accommodate voltages to the AC power source or the optional 48 VDC power source The power supplies meet standard voltage requirements for both North American USA and Canada operation and worldwide except USA and Canada operation They use standard industrial wiring with line to neutral or line to line power connections Chapter 2 Sun Storage 2500 M2 Arrays Specifications 9 10 Note Power for the optional 48 VDC power configuration is supplied by a centralized DC power plant instead of the AC power source in the cabinet Refer to the associated manufacturer s documentation for specific DC power source requirements Consider the following information when preparing the array s installation site Protective ground Site wiring must include a protective ground connection to the AC power source or the optional 48 VDC power source Note Protective ground is also known as safety ground or chassis ground Circuit overloading Power circuits and associated circuit breakers must provide sufficient power and overload protection To prevent possible damage to the array isolate its power source from large switching loads such as air conditioning motors elevator motors and factory loads Power interruptions Th
10. e controller tray can withstand the following applied voltage interruptions with or without an integrated uninterruptible power supply UPS Input transient 50 percent of the nominal voltage Duration One half cycle Frequency Once every 10 seconds Power failures If a total power failure occurs the controller tray automatically performs a power on recovery sequence without operator intervention after power is restored Note When a power failure occurs the controller tray uses battery power to back up the data that is in cache Site Preparation Guide August 2011 AC Power Input The AC power sources must provide the correct voltage current and frequency specified on the tray model and serial number label The tray can run without interruption within the limits shown in TABLE 2 11 TABLE 2 11 Tray AC Power Requirements Condition Specification Input voltage 100 240V Input frequency 50 or 60Hz Input current 7 0 2 9A DC Power Input The DC power source must provide the correct voltage current and frequency specified on the array nameplate label and the serial number label Nominal input voltages for the DC power source are as follows Input voltage 42 to 60VDC Operating current 21 7 to 15 3A Controller Tray Power Factor Correction Power factor correction is applied within the power supply which maintains the power factor of the controller tray at greater than 0 95 with
11. ml Support https support oracle com Training https education oracle com Site Preparation Guide August 2011 CHAPTER 1 Planning for the Installation This chapter describes the requirements for preparing the customer site for installation of Sun Storage 2500 M2 Arrays It contains the following sections m Customer Obligations on page 1 Safety Information on page 1 Customer Obligations The customer is obliged to inform Oracle Corporation of any and all ordinances and regulations that might affect the installation The customer is responsible for meeting all government codes and regulations concerning facilities The customer is also required to do the following Comply with all local national and international codes covered in this specification The subjects covered include fire and safety building and electrical codes Document and inform Oracle Corporation of any deviations from this specification Safety Information Install Sun Storage 2500 M2 Arrays in accordance with the local safety codes and regulations at the facility site Make sure that you read the safety precautions in the Sun Storage 2500 M2 Arrays Regulatory and Safety Compliance Manual The following sections contain additional safety information for the local facility Handling Precautions on page 2 Secure Installation Requirements on page 2 Placement of a Product on
12. ns fournies dans ce document sont susceptibles de modification sans pr avis Par ailleurs Oracle Corporation ne garantit pas qu elles soient exemptes d erreurs et vous invite le cas ch ant lui en faire part par crit Si ce logiciel ou la documentation qui l accompagne est conc d sous licence au Gouvernement des Etats Unis ou toute entit qui d livre la licence de ce logiciel ou l utilise pour le compte du Gouvernement des Etats Unis la notice suivante s applique U S GOVERNMENT RIGHTS Programs software databases and related documentation and technical data delivered to U S Government customers are commercial computer software or commercial technical data pursuant to the applicable Federal Acquisition Regulation and agency specific regulations As such the use duplication disclosure modification and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract and to the extent applicable by the terms of the Government contract the additional rights set forth in FAR 52 227 19 Commercial Computer Software License December 2007 Oracle America Inc 500 Oracle Parkway Redwood City CA 94065 Ce logiciel ou mat riel a t d velopp pour un usage g n ral dans le cadre d applications de gestion des informations Ce logiciel ou mat riel n est pas con u ni n est destin tre utilis dans des applications risque notamment dans des application
13. or the array TABLE 2 6 Altitude Ranges for the Controller Tray Environment Specification Operating 100 ft 30 5 m below sea level to 9840 ft 3000 m above sea level Storage 100 ft 30 5 m below sea level to 9840 ft 3000 m above sea level Transit 100 ft 30 5 m below sea level to 40 000 ft 12 000 m above sea level Airflow and Heat Dissipation TABLE 2 7 Airflow and Minimum Clearance Position Clearance Front 30 in 76 cm Back 24 in 61 cm TABLE 2 8 Power and Heat Dissipation for the Controller Tray Component KVA Watts AC Btu Hr Controller modules with two power fan 0 400 399 modules and 12 drives 1366 Site Preparation Guide August 2011 Acoustic Noise TABLE 2 9 Acoustic Noise at 25 C for the Controller Tray Measurement Level Sound power standby operation 6 2 bels maximum Sound pressure normal operation 6 2 bels maximum Shock and Vibration TABLE 2 10 lists the shock and vibration specifications for the controller tray TABLE 2 10 Shock and Vibration Condition Parameter Specification Vibration Operating 5 500 5 Hz sinusoidal Nonoperating unpacked 5 500 5 Hz sinusoidal 1 octave per minute flat profile 50 G Shock Operating no damage 10 g peak acceleration 5 ms duration 1 2 sine pulse Nonoperating unpacked 20 g peak acceleration 8 ms duration trapezoidal pulse Electrical Requirements This section provides information regarding site power
14. s Guide Before you begin to install Sun Storage 2500 M2 Arrays you must have already read the regulatory and safety requirements described in this book Sun Storage 2500 M2 Arrays Regulatory and Safety Compliance Manual Related Documentation Task Title Review safety information Review known issues and workarounds Prepare the site Install the array Install the management software Install multipath driver Manage the array Troubleshooting and hardware replacement procedures Sun Storage 2500 M2 Arrays Safety and Compliance Manual Important Safety Information for Sun Hardware Systems Sun Storage 2500 M2 Arrays Hardware Release Notes Sun Storage Common Array Manager Release Notes Sun Storage 2500 M2 Arrays Site Preparation Guide Sun Storage 2500 M2 Arrays Hardware Installation Guide Sun Storage Common Array Manager Quick Start Guide Sun Storage Common Array Manager Installation and Setup Guide Sun StorageTek MPIO Device Specific Module Installation Guide For Microsoft Windows OS Sun StorageTek RDAC Multipath Failover Driver Installation Guide For Linux OS Sun Storage Common Array Manager Array Administration Guide and Online Help Service Advisor launched from Sun Storage Common Array Manager vi Documentation Support and Training These web sites provide additional resources Documentation http www oracle com technetwork documentation oracle unified ss 193371 ht
15. s affili s ne sauraient tre tenus pour responsables des pertes subies des co ts occasionn s ou des dommages caus s par l acc s des contenus produits ou services tiers ou leur utilisation E Li Adobe PostScript Contents About This Guide v Planning for the Installation 1 Customer Obligations 1 Safety Information 1 Handling Precautions 2 Secure Installation Requirements 2 Placement of a Product 2 Sun Storage 2500 M2 Arrays Specifications Dimension and Weight Specifications 6 Environmental Requirements 7 Humidity 7 Altitude 8 Airflow and Heat Dissipation 8 Acoustic Noise 9 Shock and Vibration 9 Electrical Requirements 9 Site Wiring and Power 10 AC Power Input 11 5 DC Power Input 11 Controller Tray Power Factor Correction 11 Power Cords and Receptacles 11 AC Power Cords 11 DC Power Connector Cables 12 Battery Life 12 A Configuration Worksheets 13 iv Site Preparation Guide August 2011 About This Guide The Sun Storage 2500 M2 Arrays Site Preparation Guide describes facilities and system requirements for installing Sun Storage 2500 M2 Arrays Follow the guidelines as outlined in this document when planning your installation This guide helps you make decisions about ventilation electrical power floor loading and network configuration Conduct a power survey to make sure that the storage array and input power is free of noise spikes and fluctuations Before You Read Thi
16. s pouvant causer des dommages corporels Si vous utilisez ce logiciel ou mat riel dans le cadre d applications dangereuses il est de votre responsabilit de prendre toutes les mesures de secours de sauvegarde de redondance et autres mesures n cessaires son utilisation dans des conditions optimales de s curit Oracle Corporation et ses affili s d clinent toute responsabilit quant aux dommages caus s par l utilisation de ce logiciel ou mat riel pour ce type d applications Oracle et Java sont des marques d pos es d Oracle Corporation et ou de ses affili s Tout autre nom mentionn peut correspondre des marques appartenant d autres propri taires qu Oracle AMD Opteron le logo AMD et le logo AMD Opteron sont des marques ou des marques d pos es d Advanced Micro Devices Intel et Intel Xeon sont des marques ou des marques d pos es d Intel Corporation Toutes les marques SPARC sont utilis es sous licence et sont des marques ou des marques d pos es de SPARC International Inc UNIX est une marque d pos e conc d e sous licence par X Open Company Ltd Ce logiciel ou mat riel et la documentation qui l accompagne peuvent fournir des informations ou des liens donnant acc s des contenus des produits et des services manant de tiers Oracle Corporation et ses affili s d clinent toute responsabilit ou garantie expresse quant aux contenus produits ou services manant de tiers En aucun cas Oracle Corporation et se
17. tion All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc UNIX is a registered trademark licensed through X Open Company Ltd This software or hardware and documentation may provide access to or information on content products and services from third parties Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third party content products and services Oracle Corporation and its affiliates will not be responsible for any loss costs or damages incurred due to your access to or use of third party content products or services Copyright 2011 Oracle et ou ses affili s Tous droits r serv s Ce logiciel et la documentation qui sr ng sont ag par les lois sur la propri t intellectuelle Ils sont conc d s sous licence et soumis des restrictions d utilisation et de divulgation Sauf disposition de votre contrat de licence ou de la loi vous ne pouvez pas copier reproduire traduire diffuser modifier breveter transmettre distribuer exposer ex cuter publier ou afficher le noel m me partiellement sous quelque forme et par quelque proc d que ce soit Par ailleurs il est interdit de proc der toute ing nierie inverse du logiciel de le d sassembler ou de le d compiler except des fins d interop rabilit avec des logiciels tiers ou tel que prescrit par la loi Les informatio
18. uter software or commercial technical data pursuant to the applicable Federal Acquisition Regulation and agency specific supplemental regulations As such the use duplication disclosure modification and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract and to the extent applicable by the terms of the Government contract the additional rights set forth in FAR 52 227 19 Commercial Computer Software License December 2007 Oracle America Inc 500 Oracle Parkway Redwood City CA 94065 This software or hardware is developed for general use in a variety of information management applications It is not developed or intended for use in any inherently dangerous applications including ln which may create a risk of personal injury If you use this software or hardware in dangerous applications then you shall be responsible to take all appropriate fail safe backup redundancy and other measures to ensure its safe use Oracle orporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications Oracle and Java are registered trademarks of Oracle and or its affiliates Other names may be trademarks of their respective owners AMD Opteron the AMD logo and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices Intel and Intel Xeon are trademarks or registered trademarks of Intel Corpora
Download Pdf Manuals
Related Search
Related Contents
Cooler Master HAF XM SOLAR BATTERY USER MANUAL FLENDER couplings - Service, Support Intel® Rapid Start Technology Driver Personnel de soutien Syndicats indépendants La présente lettre d GE 00019577 Telephone User Manual Article Bedienungsanleitung SPS24 SENCOM® PC-Software USBスマートメディアカードリーダ取扱説明書 ADR-SMU Philips L 1250 - HPM User's Manual Copyright © All rights reserved.