Home
PCS220 - Test Equipment Depot
Contents
1. need to increase reduce beyond 1 kg A z GD Z X TS Iv r i g g Ww Press SET to start program amount Press to increase setting charging amount or pause when charging Press to reduce setting charging amount Switch 2G or 5G resolution Activates Deactivates stored pro gram Check if electromagnetic valve operates normally LCD background lamp 10 27 2011 10 08 10 AM Basic Weighing Operation To operate the PCS220 as a basic weight scale perform the following steps 1 2 Remove the PCS220 from the carry case When using the PCS220 ensure the coiled cord does not touch the top of the weighing platform or inaccuracies may result lf desired extend the easel at the top back of the control box by pulling it out The easel may be used straight for hanging or folded at an angle for resting on a level surface Install the batteries into the control box as described in the Battery installation section below Place the weighing platform on a firm level surface Turn the PCS220 ON by pressing select the proper measurement units by repeated pressing The units will cycle as follows kilograms pounds lf using a container to hold the objects being measured place it empty on the center of the platform TARE Press to zero out the scale The display will read zero Place the material to measure in the container or on the center of the platform Re
2. the rated capacity of the PCS220 1 PCS220 Manual indd 3 D 10 27 2011 10 08 08 AM PCS220 Manual indd 4 LCD Display Option Keypad eee Coiled Cord Weighing Platform Valve Balance Point Speaker Grill Charging Hose Control Box Rear View Easel Extended Battery Cover Valve Outlet gt gt lt 4 Valve Inlet 10 27 2011 10 08 09 AM PN LCD Display I I I LI I gt I ZERO SET RUN HOLD VALVE CLOSED OPEN LOW H A 9 lbs IGH RESOLUTION 91011 12 item Function item 1 Main Numeric Display 8 2 Valve Indicator Light ON OFF 9 3 Battery Level Indicator 10 4 Floating Negative Indicator 11 Indicates weight removed from platform m 5 Display TARE ZERO 13 6 Indicate Units For oz 7 Indicate units For kg and g PCS220 Manual indd 5 Function Indicate Units For Ibs Programmable Weight Set Run Mode Indicator Hold Mode Indicator Valve Open Close Set Resolution 2G high 5G low 10 27 2011 10 08 10 AM TARE UNITS FAST aN PCS220 Manual indd 6 Electronic Refrigerant Programmable Charging Scale Press to power on Press and hold 2 seconds to power off Press to TARE ZERO current reading on display Shift imperial metric measurements Press to shift FAST SLOW setting amount Use 5g setting when you need to increase reduce within 1 kg Use 1009 setting when you
3. Test Equipment 99 Washington Street Depot Melrose MA 02176 Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431 DicrTaAL CHARGING SCALE User Gube PCS220 Manual indd 1 E 10 27 2011 10 08 04 AM Introduction Thank you for your purchase of the PCS220 electronic refrigerant programmable charging scale The PCS220 utilizes the most technologically advanced and precise refrigerant meter available today with features that cannot be found anywhere else It is ideal for HVAC and refrigeration service including Critical Charging of small refrigeration systems With the PCS220 you can measure weight in both English and metric units The PCS220 is programmable and has a built in alarm to indicate a programmed threshold has been exceeded Features e High visibility LCD display e Measures weight in Ibs and kgs Si e Built in memory remembers all previous settings e Rugged compact design e High accuracy and resolution e Programmable e Can be calibrated in the field with inexpensive reference weight Specifications Capacity 220 pounds 100 kilograms Accuracy 0 5 of reading 1 least significant digit Resolution 0 010 Ibs 5g Power 5x 1 5 V AA alkaline batteries 7 5 VDC Battery Life Type 60 hours continuous use Qty 5 AA Operation Temperature 50 F 122 F 10 C 50 C Weight 6 03 Ibs 2 74 kg Dimensions 9 13 x 9 13 x 2 28 23 2cm x 23 2 x 5 8m NOTE To prevent damage never exceed
4. ad the weight on the display A positive number indicates the applied weight is greater than the zero value A negative number indicates the applied weight is less than the zero value Turn the PCS220 OFF by pressing until the scale turns off 14 To conserve battery life the PCS220 will turn itself off after 30 minutes of inactivity unless PCS220 Manual indd 7 D 10 27 2011 10 08 11 AM it is currently running a program see programming section The last state of the PCS220 will be restored upon power up D Mt gt E Ts Refrigerant charging recovery operation 1 Install the batteries into the control box as described in the Battery Installation section on page 8 2 Place the weighing platform on a firm level surface 3 Connect one end of charging hose to INLET and the other end to refrigerant tank 4 Connect one end of charging hose to OUTLET and the other end to either the manifold gauge or auto A C system 5 Turn onthe PCS220 by pressing 6 Select the proper measurement units by repeated pressing The units will cycle as follows kilograms lt pounds 7 Place the refrigerant tank on the center of platform and open refrigerant tank valve weight displayed on the screen PCS220 Manual indd 8 D 10 27 2011 10 08 11 AM 8 Press to set weight 1 If set weight within 1kg press or gt repeatly HOLD Press to start charging work 2 I
5. f set weight beyond 1 kg press and press a HOLD or gt repeatly press to start charging work STOP 9 When finished refrigerant charging the Valve will auto shut off and alarm for 6 seconds N a oO se Note amp 1 Press if you want to pause the charging work amp 2 Press a if you want to stop and cancel charging work STOP PCS220 Manual indd 9 D 10 27 2011 10 08 11 AM Mit E Ts Battery Installation 1 Remove the battery cover from the rear of the control box by compressing tab at the base of the battery cover 2 lf necessary remove old set of batteries 3 Insert 5 AA Replace battery cover by aligning Important TO PREVENT DAMAGE TO THE PCS220 CAREFULLY OBSERVE BATTERY POLARITY AS MARKED INSIDE THE BATTERY COMPARTMENT DO NOT LEAVE DEAD BATTERIES INSIDE THE CONTROL BOX REMOVE BATTERIES IF THE PCS220 IS NOT TO BE USED FOR AN EXTENDED PERIOD OF TIME Over Range Indicator lf the weight applied to the weighing platform exceeds the maximum capacity of the PCS220 200 Ibs OL will be displayed in the middle of the display To prevent damage to the PCS 220 immediately remove the weight from the platform Parts Included 1 1 Set refrigerant charging scale 2 5PCS 1 5V AA alkaline batteries 3 1PCS charging hose 4 1 user s guide manual 5 1PCS molded case PCS220 Manual indd 10 D 10 27 2011 10 08 11 AM Test Equipment Depot 800 517 8431 99 Washingt
6. on Street Melrose MA 02176 TestEquipmentDepot cgm