Users Manual - Electric Heaters
Contents
1. 330 0388 service sunpentown com www sunpentown com
2. Temperature sensor is off or Turn off unit and contact short circuit Sunpentown If you still cannot solve the problem after trying the above unplug unit and contact Sunpentown Int l Inc Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase it will be repaired free of charge This guarantee is subject to the following terms What is Oo Sunpentown must be notified of the fault Proof of purchase must be presented to Sunpentown s nominated representative The warranty will be void if the product if modified misused or repaired by an unauthorized person The warranty after repair will not be extended beyond the original one year period All replacement parts will be new or reconditioned Parts which are replaced become the property of Sunpentown The warranty applies for the use of the product in the USA only NOTCOVERED Warranty does not include freight charges Incidental or consequential damage caused by possible defects with this product Damage to product caused by improper power supply voltage accident fire floods or acts of nature Failure of product resulting from unauthorized modifications to the product Improper installation or failure to perform the necessary maintenance This GUARANTEE is in addition to your Statutory Rights SUNPENTOWN INTERNATIONAL INC 14625 Clark Ave City of Industry CA 91745 Tel 1 800
3. tank is correctly positioned The unit will re start when the tank is restored in its correct position 1 Pull out the bucket a little 2 Hold the two sides ofthe 3 Pour the water out l bucket with even strength and pull it out from the unit Continuous Drainage e Remove the plastic cover located at the rear of the unit e Push the drain hose into the drain hole see image below e Remove the water tank and securely attach the drain hose to the connector see image below e The hose should be smooth and without bends or kinks e Place the end of the hose to a suitable drainage facility ff Remove the plastic cover PS OTS i SAT els the hose into the drain hole MAINTENANCE Important e Be sure to unplug the unit before cleaning e Do not use petrol thinners or other chemical agents to clean the unit as this may damage the unit e Do not wash the unit directly under water The electrical components inside may be damages and cause the unit to become unsafe Air Filter Clean the air filter at least once every two weeks to prevent impaired performance e Pull the air filter out as shown in Fig A e Wash the air filter with clean water and allow dry completely e Replace cleaned filter as shown in Fig C Fig A Fig B Grille and Housing Use a soft clean cloth to wipe the surface Do not use water as this may cause an electrical fault or shock hazard Air intake and outlet should be ke
4. SP IT DEHUMIDIFIER MODELS SD 30E SD 40E SD 65E SD 70E 7 y INSTRUCTION MANUAL Please read these instructions thoroughly and keep it in a safe place for future reference CONTENTS FUNETONS Ii ie oaks SAFETY NOTES cut ad NAME OF PARTS taste erosiva aio tl alce dll iii CONTROL PANEL cocaina TECHNICAL SPECIF ICA TON Siccstoonariie ter ia is INSTALLATION 3 es ee o od OPERATING INSTRUCTIONS 100 ita td OPERATION cat E LO MAINTENANCE costra as TROUBLE SHOOTING uso sicnociasiosies asol aniecrato cias E E EAE ias YOUR GUARANTEE e ee ents eos e eto oo O a BEFORE YOU USE YOUR DEHUMIDIFIER PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY FUNCTIONS 1 Prevents mold growth on clothing cupboards doors and drawers 2 Prevents condensation on ceiling walls and windows 3 Dehumidifying is effective on moisture sensitive items like musical instruments cameras computers etc 4 Removes dampness from bookshelves and closets SAFETY NOTES Do not connect unit to any damaged AC electrical socket Ensure removable covers and containers are correctly fitted before switching on unit Always switch unit off when not in use and before unplugging Do not use in the following locations e Next to or near a heat source radiator heater dryer etc e Area where oil or water is likely to splash e Under direct sunlight e Near a bath shower or swimming pool e n a greenhouse 5 Never inser
5. de at original factory setting 60 RH Press again to turn unit OFF CONTINUOUS Button When unit is in operation press this button to set CONTINUOUS DEHUMIDIFYING mode TURBO Button Press this button to set unit in high fan speed NORMAL Button Press this button to set unit in low fan speed POWER Indicator Will flash slowly when power is connected at the socket initial power Indicator lights up when unit is turned ON and dark if unit is OFF CONTINUOUS Indicator Lights up when CONTINUOUS DEHUMIDIFYING mode is selected FULL Indicator Lights up when bucket is full unit will stop operating HUMITIDY Button Press this button to increase the humidity setting Range of adjustment is from 35 80 RH in 5 increments HUMIDITY Button Press this button to decrease the humidity setting Range of adjustment is from 80 35 RH in 5 increments TURBO Indicator Lights up when TURBO button is pressed unit will run in high fan speed NORMAL Indicator Lights up when NORMAL button is pressed unit will run in low fan speed FEATURES Bucket Full Light llluminates when bucket is ready to be emptied or when the bucket is removed or not replaced in proper position Auto Shut Off The water level control switch shuts off the unit when the bucket is full or when the bucket is removed or not replaced in proper position When the set humidity is reached unit will also shut off automatically Auto Defrost When frost col
6. king environment between 41 95 F If the unit has been switched off please wait 3 minutes before switching on again If switched on immediately allow 3 minutes for unit to resume correct operation Do not connect unit to a multiple socket outlet with other electrical appliances Select a suitable location with easy access to an electrical outlet Plug the unit into an 115V 60Hz electrical socket with earth connection Make sure the water tank is correctly fitted or unit will not operate Turning the unit ON or OFF 1 Plug the cord to a proper power requirement The units computer system will have a self check If normal POWER indicator will flash at 0 5Hz Press the POWER button to start operation Unit will begin to operate at 60 humidity setting press or to change humidity setting Press CONTINUOUS button to run in continuous dehumidifying mode In continuous mode or buttons are disabled Press POWER button again to turn off unit You do not need to unplug the cord except when unit will not be used for a long period of time OPERATION Water Tank When water tank is full unit will stop operating and FULL indicator light will flash Never remove the water tank while unit is in operation Grip the left and right handles securely and carefully pull straight out Do not place tank on the floor as the bottom of the tank is not even and will tilt Empty the water and gently push the tank all the way in Ensure the
7. lects on the evaporator coils compressor will cycle off and fan will continue to run until frost disappears Auto Restart Function When there is power failure unit will restore to previous function setting and restart when power returns TECHNICAL SPECIFICATIONS MODEL SD 30E SD 40E SD 65E SD 70E Dehumidifying Capacity 30 pints per day 40 pints per day 65 pints per day 70 pints per day Power Supply 115V 60Hz Current 4 3A 5 4A 6 7A 7 5A Power Consumption 420W 525W 710W 810W 41 95 F Working Environment 25 RH and above Water Tank Volume 5L 11 pints 10L 21 pints Net Weight 30lbs 45 2lbs Dimension 15 4 16x11 11 16x21 in 18x15x26 in Capacity will vary according to actual room ambient temperature and humidity conditions INSTALLATION Place the dehumidifier on a flat surface and in a location where the air inlets and outlets will not be obstructed Do not install underneath desks or inside cupboaras as this will restrict the airflow Keep unit at least 40 inches away from televisions and radios as the unit may disrupt the image or sound Maintain a minimum clearance of 20cm 7 5in around the unit and 40cm 16in above the unit 40cm or more li Air intaks grille Air outlet grille y 20cm or mor 20cm or more 20cm or more A i 20cm or more OPERATING INSTRUCTIONS Operating Conditions This unit is designed to operate with a wor
8. pt free of obstacles Use a vacuum attachment or brush to clean Water Tank Wash the tank using warm water and neutral detergent Rinse and allow dry replace when dry Power Cord Wrap the cord and bundle it with a band Wiring Ear Power cord TROUBLE SHOOTING BEFORE COTACTING THE MANUFACTURER PLEASE CHECK THE FOLLOWING POSSIBILITIES PROBLEM CHECK e Power is OFF e Power cord is unplugged or not securely fitted Unit fails to operate e Water tank not placed properly e Water tank is full e Set humidity has been reached e Blocked air filter e Room windows and doors are open e Obstacles in air outlet or inlet e Not enough time allowed to remove the moisture e Humidity setting may be set too high e Ambient temperature is too cold below 41 F Performance decreased e Unstable setting of unit or floor surface is not level Pate Rely e Blocked filter Frost appears on coils e This is normal The dehumidifier has Auto Defrost feature e Hose connection for continuous drainage is loose Water on floor e Intend to use the bucket for water collection but the back drain plug is removed The following displays indicate an error or problem Display code Problem What to do Unit will automatically restart P1 Defrosting starts after defrosting P2 Water tank is full Empty the tank E1 Humidity sensor is off or short Turn off unit and contact circuit Sunpentown E2
9. t your finger or other foreign objects into grills or openings Take special care to warn children of these dangers Allow unit to stand upright for at least 24 hours before initial operation and after moving or tilting the unit Store the unit upright to maintain the compressor in proper working condition Always unplug the unit before cleaning and maintenance Do not cover the unit and it air inlets outlets Do not spray insecticides or any other flammable sprays on the machine 0 Do not spray water on the unit 1 There are no user serviceable parts Should the unit or supply cord become damaged contact the manufacture immediately 12 Empty the water tank before moving the dehumidifier 13 This unit is equipped with auto defrosting which operates when the evaporator generates frost This function ensures continuous operation when the temperature is down to 41 F PROD 9 za ooN NAME OF PARTS Control Panel a _ ow Air Inlet 7 2 Pe Ss lt ab Air Outlet Air filter Drain Hole fle For permanent drainage Water tank E f _ k i e cg r _ Wiring Ear E os ul so Power Cord CONTROL PANEL 10 11 S J 49 G f P TFT 7 o o o o o Powe orto Fl rho Normal ans TIBIO o 5 p at Pos o a z 7 E i J A a AN POWER Button Press once to turn unit ON unit will begin operating in dehumidifying mo
Download Pdf Manuals
Related Search
Related Contents
Philips 3000 series Blu-ray Disc/ DVD player BDP3380K user`s manual - Derive Systems Tilda user manual BE24_OEM_US (2) Copyright © All rights reserved.
Failed to retrieve file