1. er or bwork e Stason Protect TOP AENEAN anz d Se iG Sone Madi o D T her Calne Mol de Head Mackie PLC made QOU Q mods CCT Cent CCIEREE Efwrmet Coane ET 10H Arressmw Heit Sen Majige CPU Seting Target Sn J J 3 j Torget PLC F 34 hat Soeafad 8 3 K 4 i813 Atep 8 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company RS 232 via a Startech EC1S952 Express Card RS 232 Adapter This card can be purchased at CDW COM http www cdw com shop products default aspx Pedc 1830145 amp enkwrd ALLPROD 3a 1830145 In Windows 7 64 Bit OS goto the product webpage and download the latest drivers EC1S952 zip uder the Drivers tab and unzip save to your PC http us startech com product EC1S952 1 Port Native Express Card RS232 Serial Adapter Card with 16950 UART Insert the card and install the drivers manually in Win 7 64 Bit OS by following the same procedure as the USB drivers above In the Computer Management Device Manager screen the device will intially come up under Other Devices Right click on the Unknown device and select Properties In the Properties menu select Update Driver and find the Vista 64 Bit driver from the EC1S952 zip file you previously downloaded 9 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation
2. COM amp LPT gt E Services and Applications 5 EC DaumibeesH gt gt gt gt be I Intel R Active Management Technology Y Keyspan USB Serial Port COM7 Y RIM Virtual Serial Port v2 COMS ne Vir erial Por OME gt D Processors gt SBE SD host adapters gt DP Security Devices 9 E Smart card readers gt Sound video and game controllers 4M System devices d F Universal Serial Bus controllers Generic USB Hub Generic USB Hub 9 Intel R 5 Series 3400 Series Chipset Family USB Enhanced Host Controller 3B34 9 Intel R 5 Series 3400 Series Chipset Family USB Enhanced Host Controller 3B3C Keyspan USB Serial Adapter NEC Electronics USB 3 0 Host Controller oo NEC Electronics USB 3 0 Root Hub USB Composite Device USB Root Hub gt USB Virtualization 18 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company To change the Com port Double Click on the Keyspan USB Serial Port COM7 under Ports go to the Port Settings Tab and select Advanced Change the COM Port Number on the bottom left of the screen to COM2 Fader 1 LIS Comte eere RT EA o Fue Achion Wom Mep i vite RIC BE ze Bw A Computer Management Local a STELLER Auctions i a Ui System Toots AB Datteries 2 Task ar h
3. Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company dE Computer Manageme it me 8 Ele Action View Help e AE El Ia e e og ge Computer Management Local 4 A SZELLER P ii System Tools T Batteries b 3 Task Scheduler E Biometric Devices gt BH Event Viewer B Bluetooth Radios gt mE Shared Folders b 4M Computer b Si Local Users and Groups b xc Disk drives b Ki Performance i My Display adapters Device Manager 53 DVD CD ROM drives 4 Gs Storage i fe Human Interface Devices c Disk Management xg IDE ATA ATAPI controllers p Bs Services and Applications g IEEE 1394 Bus host controllers M Imaging devices gt m Keyboards A Mice and other pointing devices i A Modems KS Monitors UOTE THE Jn Other devices 4 1 PCMCIA adapters AP Ports COM amp LPT n Processors b A SD host adapters b JB Security Devices b le Smart card readers b Sound video and game controllers p 4M System devices b 7 g Unrversal Serial Bus controllers Q USB Virtualization 10 Page More Actions MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Once the driver is installed you will see the card PCI Express Legacy COM Port COMx under the Ports COM amp LPT selection If you wish to select
4. another COM port other than the one originally selected right click and select Properties 2 Computer Management f i Ele Action View Help e gt AG E Ge e es Computer Management Local 4 x3 SZELLER 4 il System Tools DA Batteries p Task Scheduler D 18 Biometric Devices gt BH Event Viewer D e Bluetooth Radios z Shared Folders gt gil Computer gt S Local Users and Groups cq Disk drives b E Performance A Display adapters zi Device Manager gt d DVD CD ROM drives 4 fis Storage fs Human Interface Devices E Disk Management gt cg IDE ATA ATAPI controllers D Bs Services and Applications b g IEEE 1394 Bus host controllers M Imaging devices gt m Keyboards A Mice and other pointing devices 4E Modems i Monitors EP Network adapters 5 S Other devices PCMCIA adapters a Y Ports COM amp LPT eRe SOL COMMS I RIM Virtual Serial Port v COMMS RIM Vitter vio i n Processors gt AE SD host adapters DS Security Devices b E Smart card readers i Sound video and game controllers JE System devices T g Universal Serial Bus controllers b USB Virtualization 11 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Under the Port Settings Tab select Advanced Party 12 Page MITSUBISHI ELECTRIC Mitsubishi Electric
5. eta Dan Lu Aj Ahen REC Cacabdobamhas AC LI bok Qna ee in Usi St ril chaps if HAT ns tor an eam paul L 20 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Open Window 7 32 Bit Virtual PC Under the Tools Menu select Settings Ehsable In amp rgrainsn Features 21 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company In Settings change COM2 Port on the left side to Physical serial port COM2 on the Right Side This is now the COM port to use in the software Setting _ Name E Memory cow Hard Disk 1 cow Hard Disk 2 cow Hard Disk 3 cx Undo Disks eia DVD Drive By Integrate E Keyboard F Logon Credentials Auto Publish Close 22 Page Current Value Windows 7 32bit 3 200 MB Windows 7 32bit None None Disabled Auto Enable Full screen Saved Enabled Show message Named pipe Text file You can select a serial port on the computer a named pipe or a text file to use a COM port in the virtual machine More about using a COM port MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Com
6. use a COM part in the virtual machine More about using a COM port er Len Close the Window 7 32 Bit Virtual PC and restart 14 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Open GX Works2 and Setup Connection for COM1 and do a Connection Test Tools Cui Alt Dei EISOR Project Edit find Replace Compile View Online Deb OBAS i E i EEF gt dd Dmeoutiec 3 Retry Times 9 CC Cont CCIE fied Ethernet NET 100H E NN CClECa CCIEPeld Ethernet NET 10 Accessing Host Staton Mltple CPU Seting j E J j rarget ac Not Soecfied You should get a Connection Test Confirmation Message This test was done with a SC Q cable and a Q CPU using the RS232 Port 15 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company You should get a Connection Test Confirmation Message This test was done with a SCO9 cable and a FX1N CPU using the RS232 Port Hi Adi USE Took Cle Ale Dd Tt ar T ry X P Sere 16 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company RS 232 via a Keyspan USA 19HS USB Converter Co
7. 2 C Program GX Achie Files MELS All QPCU 19 CONFIG2 1 01A USB QO6UDEH ved OFT Easyso Communication MB cket USBDri Methods Work vers C Program GX Achie Files MELS All QPCU 20 CONFIG2 1 01A USB QO6UDEH wed OFT Easyso Communication DN cket USBDri Methods Work vers C Program GX Achie Files MELS All QPCU 21 CONFIG 2 325 USB QO6UDEH Jen OFT Easyso Communication QP cket USBDri Methods Work vers Projects should be kept on Local iQ Works VMWare C ne Navigator meu bdo NES NA Drive Do NOT use Network or Host Drive LCPU C Program j logging aan USE L26CPU Achie Files MELS i an Config BT ved OFT Easyso Piel eater Tool cket USBDri 29 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company MES Interface 1 07H Ethernet MESIT IT T x Configurat 1 01B USB with SW or 2 install T Configurat USB with SW Or install C Program MT Developer Q172D via Files MELS Direct driver 27 p 1 18U USB OFT Easyso install to file AN ADEN cket USBDri folder location Works2 vers MT 27 Developer Q172D via 2 MT 1 18U Ethernet QOGUDEH Works2 C Program Ach Files MELS All QPCU 28 ncm 3 14Q USB QO6UDEH OFT Easyso Communication nt cket USBDri Methods Work vers vers N A C Program Achie Files MELS All QPCU MX OPC QO6UDEH OFT Easyso Communication cket USBDri Methods Wor
8. 3 install GT10 For use with GT USB to GOT RS RSTUSB 5S GT1020 May Designer Achie for USB have to direct 1 28E 232 Converter GT1020 3 GT GT10 RSTUSB 5S ved Device and driver installer to Works3 COM Port folder that holds Device GT10 RSTUSB 5S Drivers Keyspan USA er TAR An RE Achie bined 3 GT 1 28E GT1020 v 19us Works3 B B Connected Cable to PC GT15 w GT15 Designer BE Ethernet J71E71 100 dui SS vag Module Installed Works3 GT Simulator 3 GT 1 28E N A N A N A N A N A Works3 GT Manuals 3 GT 1 28E N A N A N A N A N A Works3 GT SoftGOT1 Achie 000 GT 3 28E Ethernet QO6UDEH ved N A N A Works3 chis All QPCU 7 04E Ethernet QOGUDEH ved N A Communication Methods Work GX Keyspan USA ST I O Achie Drivers 27 Page G I Ui gt O 2 D 12 Configurat MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company or ST RS 232 Programming Cable e 8 952 USB Developer 14 GX PC USB out to FX 8 957 USB AW or FX3U a Developer USB BD Keyspan USA 19HS and SCO9 RS 232 Programming Cable 14 GX b Developer nid PC USB out to GOT1000 USB Pass Thru 14 GX 8 957 c Developer QO6UDEH FX3U FX3U FX3U with USA 19HS Connected to PC C Program Files MELS Direct driver install to file folder location Achi Ms OFT Easy
9. Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Under COM Port Number select the number you want Use COMI if it is open Select lower settings to comect connection problems Select higher settings for faster performance Receive Buffer Low 1 5 High 14 14 Transmit Buffer Low 1 p High 16 16 Select OK and Reboot your laptop Open Window 7 32 Bit Virtual PC and from the WINDOWS VIRTUAL PC Titlebar goto Tools gt Settings Toots Cirle Aie Mef Diable leitegrabson Prahat 13 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Under the Windows Virtual PC Settings select COM1 setting on the Left and assgin COM1 under Physical serial Port to COM1 or the port that was selected by the Serial Card perviously Then Select OK Current Value Name Windows 7 32bit Memory 3 200 MB cow Hard Disk 1 Windows 7 32bit cw Hard Disk 2 None cw Hard Disk 3 None cow Undo Disks Disabled e DVD Drive D sical serial e Mamed pipe T COM2 a Networking Network adapters 2 By Integration Features Auto Enable 2 Text file es Keyboard Full screen 7 Logon Credentials Saved E7 Auto Publish Enabled 3 Close Show message Browse You can select a serial port on the computer a named pipe or a text file to
10. Bit VMWare Software Image and Test to MEAU Devices The following Mitsubishi Software Titles and Versions have been fully testing in May 4 2011 VMWare Version 7 1 4 build 385536 using Windows 7 Service Pack 1 32 Bit OS Revision Date Connection Driver Software Version Method DEVICE Required fespan US ecd 19HS and Alpha l 1 Alpha win 2 6 RS 232 M jo N A Programmin MER dis pM Connected to PC fes US se 19HS and CAB30 Achie with USA RS 232 E1070 MEN E ved 19HS 6 Connected to PC Ethernet E1070 Ache N A an ved m i Achie haat Configurat E700 e With SW N A or install Ete FR Configurat Drivers Keyspan USA 700 installed 19HS and SC FRPC eon Achie with USA Green RS 232 ved 19HS UP Connected to PC cyepan USA zonae Achie with USA 232CAB 1 RS 232 F940 Programming ue xdi Connected to PC Direct driver installer to PCUSBouttoFX FX3U Achie PUSB folder that holds 20SSC H ved AW FX3U FX USB USB BD AW FX3U USB BD for USB and RS 232 Function Configurat or FP 25 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Keyspan USA hala 5a a rat 1 50 wir a del mesic wine N A Bu 20SSC H ved 19HS or FP Programming Connected Cable to PC 5b Configurat Drivers PC USB out to FX3U Achie installed 1 50 GOT1000 USB 20SSC H ved with
11. MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Technical Bulletin Installing GX Works2 V1 48a on a Win7 64 Bit PC Index Chapter 1 Installing GX Works2 V1 48a in Win7 64 Bit PC sees Page 1 Chapter 2 Installing GX Works2 V1 48 in Win7 32 Bit WINDOWS VIRTUAL PC Page 2 Chapter 3 Installing GX Works2 V1 48 in Win7 32 Bit VMware Workstation Page 24 Because GX Works2 V1 48a is NOT Windows 7 64 Bit Compatible Windows Virtual PC using Windows 7 32 Bit Mode or VMWare using a Window 7 32 bit Image can be used See next page s for details 1 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Chapter 2 Installing GX Works2 V1 48 in Win7 32 Bit WINDOWS VIRTUAL PC It installs but this warning appears when installing USB drivers It appears twice Select Install this driver software anyway 71 Windows 7 32bit Windows Virtual PC e jme Action USB v Tools v Ctrl Alt Del See Don t install this driver software You should check your manufacturer s website for updated driver software for your device gt Install this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned softw
12. SW N A Pass Thru install Direct driver installer to FX PC USB out to FX FX USB folder that holds FX3U Achie Configurat 1 30 USB AW or FX3U ENET AW FX3U FX USB or EN USB BD USB BD AW FX3U USB BD for USB and RS 232 Function Dri Keyspan USA heehee C Bes m Bio d FX3U Achie with USA cie ENET ved 19HS or EN Programming Cable Connected to PC Drivers FX PC USB out to Configurat 1 30 GOT1000 USB pue enews seas ENET ved with SW or EN Pass Thru install EA yeu ache IP Address Must 6c Configurat Ethernet ENET ved Be Set First Via or EN RS 232 or USB Designer 2 GT Works2 USB Drivers Achie installed ved with SW install GT10 For use with USB to GOT RS RSTUSB 5S GT1020 May Achie for USB have to direct fee convener 29A ved Device and driver installer to SERB COM Port folder that holds Device GT10 RSTUSB 5S Keyspan USA Drivers 19HS and SC Q Achie installed RS 232 even ved with USA Programming 19HS Designer 2 GT Works2 Designer 2 GT Works2 26 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Cable Connected to PC GT GT15 w GT15J71 GT15 w GT15 Designer 5 103H Ethernet GT15 Achie 74 100 J71E71 100 2 GT GT16 ved Module Module Installed Works2 Installed GT Drivers Designer Achie installed 3 GT d uH ved with SW Works
13. are from other sources may harm your computer or steal information v See details rex gt r a fs Re uno MA Select NO to this prompt 2 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company TI Windows 7 32bit Windows Virtual PC Action USB Tools Ctrl Alt Del B ox we D u GX Works2 InstallShield Do you want to register the software for speeding up the startup of GX Works2 into the Start up folder When registered the security software may affect and cause an error at the speed up software startup However the GX Works2 operation is not affected 9 51 AM PRI zio USB Driver on Win7 64 side failed to install when USB cable connected to PLC CPU B Driver Software Installation Device driver software was not successtully installed Unidentified Device No driver found What can I do if my device did not install 3 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company To install USB driver manually in the WINDOWS VIRTUAL PC you have to goto USB gt Unidentified Device and select it in the WINDOWS VIRTUAL PC Titlebar Then follow the USB driver Installation as documented in Technical Bulleting FA A 0091 B pages 7 th
14. e MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company In the Setting Menu Select Networking and make sure for Adapter 1 you have your physical network card selected 31 Windows 7 32bit Windows Virtual PC Settings Setting Current Value Name Windows 7 32bit B Memory 3 200 MB cow Hard Disk 1 Windows 7 32bit cw Hard Disk 2 Mone cw Hard Disk 3 Mone c Undo Disks Disabled e DVD Drive D Adapter 2 Not connectec H cou None None Network adapters 2 Adapter 4 Mot connected By Integration Features Auto Enable ee Keyboard Full screen 7 Logon Credentials Saved Auto Publish Enabled A Close Show message amp The virtual machine must be shut down before you can add or remove a network adapter How do I shut down A Networking lt Number of network adapte Adapter 3 Not connected You can use Shared Networking NAT or a network adapter to access an external network Use Internal Network to communicate with other virtual machines on this computer More about networking and virtual machines 7 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Setup your Ethernet Connection Destination as you normally would and do a Connection Test ra Series
15. euer J tion z ace Manager li Evert Viewer 5j Blue erp USA Seral Port OMT Properties E Mare Actions k BE Shared Folders i ca z a Local Users and Groups i a Disk j ssnand Fed Sero Diis En Perfermance M Disp qi Device Manager fj DWD P3 Borage R Hur imf Disk Management a IDE E Brice and AggbcMions IEEE bons P oue dj Medi K Han Recreo FIPO Sine tea o p n Traramit Crmpleson Timing Adee Etnis efe 3 m Best un i F E In Brod BU 50 Hi P Sedi T mal E bou E ate dirt 9 L LJ HEH AM 25 2011 EE aid 19 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company If the PC does not automatically install the drivers use the Keyspan Windows 7 driver install software did not have to use this but it is available on the Keyspan website Toole PLE Kun AM P bane r Documents Keyspan Diver USA 18H5 r r 0 irate kri per chart eth s Ies folder UP Favonter Documents library BE Cesktop Keyspan Driver USA LOM Ji Downloads 3 Recent Placet Ub Eeyspan Diver for U5A 19HG vib Beta A 3 Libewies ES Windows 7 wib eta Danumentz a Mu Wes Piue H Videos D Computer EL Local Disk CJ GF C on SELLER D D on SZELLER GP Bon STELLER Di U on STELLER tg Y on ELLER Vig Network ETE Windows T vib
16. he procedure is exactly the same TIT BA 3 9 2011 a Mr Y oda Eile Action View Help n c BE flor 2 Computer Management Local 4 23 WIN 96C6838RAJO 4 System Tools Ago Batteries Task Scheduler amp Computer d Event Viewer cs Disk drives More Actions amp amp Shared Folders amp Display adapters amp Local Users and Groups 43 DVD CD ROM drives Performance ei Floppy disk drives ay Device Manager e Floppy drive controllers 3 Storage 5 Human Interface Devices f Disk Management g IDE ATA ATAPI controllers Es Services and Applications Jungo amp Keyboards A Mice and other pointing devices E Monitors amp Network adapters TE Dag z Device Manager Communications Port COMI 9 Communications Port COM6 Ed Keyspan USB Serial Port COM2 YD Printer Port LPT1 MEO CESSOTS X Sound video and game controllers lt gt Storage controllers JE System devices 4 Universal Serial Bus controllers Q Generic USB Hub Intel R 82371AB EB PCI to USB Universal Host Controller Keyspan USB Serial Adapter Standard Enhanced PCI to USB Host Controller USB Composite Device USB Root Hub USB Root Hub 24 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Here is a list of all Mitsubishi software and Connection Methods that have been tested Windows 7 32
17. k vers QD8 amp 1DL9 6 Log 1 03D Ethernet QD81DL96 m Config 31 Ethernet E1070 p ender Designer Menu ee SD Achie BE I eee Epa i m Keyspan USA Drivers 19HS and MR installed CPCATCBL3M RS MRJ25 B with USA NA 232 Programming 19HS 30 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Cable Keyspan USA 19HS and WSO 1 2 1 0 C20R2 RS 232 WSO CPU Programming Cable WS Developer Keyspan USA 19HS can be purchased from www cdw com http www cdw com shop products Keyspan Hi Speed USB Serial Adapter PC MAC supports Cisco Break Sequence 555201 aspx This information does NOT guarantee compatibility or connectivity Use as a general guideline for software 2 and hardware use Mitsubishi USB Drivers DO NOT need to 3 loaded on the HOST OS Win 7 64 bit first 31 Page Connected to PC Drivers installed with USA 19HS Connected to PC
18. nnected Conveter to PC and in Win7 64 Bit OS These are the install messages Driver Software Installation Installing device driver software Keyspan USA 19H Q Installing driver software Device driver software was not successfully installed Please consult with your device manufacturer for assistance getting this device installed Keyspan USB Serial Adapter Failed Keyspan USB Serial Adapter Preloader Ready to use Keyspan USB Serial Port COM JM Ready to use What can I do if my device did not install properly 17 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company In the Win7 64 bit Device Manager the Adapter is shown under PORTS and under USB Controllers assigned to COM7 Port number may differ on your system The Keyspan Adatper is ALWAYS seen as a COM Port not a USB Device E Computer am Sm File Action View Help Af BA S W Computer Management Local gj IDE ATA ATAPI controllers 4 System Tools b Q IEEE 1394 Bus host controllers Task Scheduler gt JS Imaging devices ll Event Viewer gt Keyboards More Actions a Shared Folders gt F Mice and other pointing devices Local Users and Groups gt 4E Modems amp Performance gt KD Monitors gy Device Manager bs amp Network adapters 4 Storage gt PCMCIA adapters t Disk Management 4 9 Ports
19. pany In GX Works2 setup a RS232 Connection Using COM2 and do a Connection Test This test was done with a SC Q cable and a Q CPU using the RS232 Port 23 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Chapter 3 Installing GX Works2 V1 48 in Win7 32 Bit VMware Workstation Using VMWare Windows 7 32 Bit Workstation the following Connection Methods were tested e Direct USB e Direct Ethernet e Keyspan USB to RS232 Adapter Comm Port Assignment in VMWare Device Manager VMWare does not require the Manual connecting and reconnecting of USB devices VMWare does not require the manual selection of Ethernet ports or RS232 Ports VMWare does not require product spectific USB Drivers be loaded in the Host PC Windows 7 64bit The handling of Connections and Ports are all automatically done in VMWare The bottom right hand corner on the VMWare Workstation shows all the connected devices including hard drives ethernet connections printers and USB Mitsubishi Device shown in RED or Keyspan Device shown in BLUE default devices If the connection is shown here the connection can be made within the VMWare Workstation If a USB driver needs to loaded manually in VMWare follow the above directions for loading the USB driver manually in the Virtual PC T
20. rough 10 This is done thru the Computer Management gt Device Manager Menus in Win 7 Action of Tools v Ctrl Alt Del gt Wireless Bluetooth Device Attach HP Webcam 2 MP Macro Release Unidentified Device Release Leer P m 4 CO spo 4 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Connection Test with USB Device Attached in WINDOWS VIRTUAL PC USB Menu Action v USB v Tools Ctrl Alt Del aiima mmc i Project Edit P E Fil tion Desti GX Wo i CC IE Field CP cy 0m GOT CC IE Field Master Local Communication Current Conne Module Module Head Module gt Connectio PLC Mode QCPU Q mode All Connections Connection Channel List Line Connection Q 46TEL C24 CCIECont CC IE Field Ethernet NET 10 H Accessing Host Station Multiple CPU Setting 3333 Target PLC t Specified gt o pe Q4 TS AM 2 10 2011 5 Page MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 478 2100 An ISO9001 Certified Company Ethernet In order for the Win 7 32bit WINDOWS VIRTUAL PC to have access to the Ethernet Card you have to Tools Settings Menu in the WINDOWS VIRTUAL PC Titlebar 6 Pag
21. so cket USBDri vers lt D abo Direct driver installer to folder that holds FX USB AW FX3U USB BD for USB and RS 232 Function Drivers installed with USA 19HS N A Connected to PC FX USB AW FX3U USB BD Achie lt D e Achie lt D ab Drivers Achie installed with SW 14 GX Achie iQ CPU Front 95Z Eth DEH N A d Developer idis MERNE eee Ethernet Port aH oS 8 957 Ethernet FX3U BENE N A FX3U ENET e Developer ved GX Log Viewer did me 16 ae 7 24A N A N A N A N A Simulator GX PC USB out to FX of Se USB AW or FX3U a Works2 E USB BD D les 28 Page 17 Works2 1 55H QO6UDEH FX3U C Program Files MELS OFT Easyso cket USBDri vers Direct driver install to file folder location Achie ved Direct driver installer to folder that holds FX USB AW FX3U USB FX USB AW FX3U USB BD Achie ved MITSUBISHI ELECTRIC Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 phone 847 An ISO9001 Certified Company 17 GX i 17 GX GX em Keyspan USA 19HS and SCO9 RS 232 Programming Cable PC USB out to GOT1000 USB 478 2100 BD for USB and RS 232 Function Drivers installed with USA 19HS Connected FX3U to PC Drivers installed Achie ed Achie V FX3U V V V g Pass Thru En ID d install 17 Achie iQ CPU Front GX 18 Simulator 1 55H N A N A N A N A N A