Home
Installation Manual
Contents
1. PEDESTAL Select a location for the keypad For door access control installations mount the keypad near the controlled door For gate control installations mount the keypad in clear view of the gate but far enough from the gate so the user cannot touch the gate from the keypad WARNING TO AVOID SERIOUS INJURY OR DEATH MOUNT BACKPLATE WITH MAKE SURE THAT THE UNIT IS FAR ENOUGH FROM THE SECURITY BOLTS AND LOCKNUTS GATE SO THAT THE USER CANNOT TOUCH THE GATE WHILE OPERATING THE KEYPAD HOWEVER THE GATE Figure 3s Pedestal Mounting Keypad Backplate MUST BE FULLY VISIBLE FROM THE KEYPAD Pedestal Mounting The F320 keypad can be mounted on a standard pedestal WALL MOUNTING Use four security bolts and locking nuts to secure the keypad s backplate to the pedestal see Figure 3 Wall Mounting The F320 keypad can be mounted directly to a wall or flat surface 0 Use the appropriate fasteners to secure the keypad s back plate to the mounting surface USE CONCRETE WEDGE ANCHORS When mounting the keypad to a concrete wall OR MOLLY ANCHORS use concrete wedge anchors or molly anchors see Figu re 4 Figure 4 Wall Mounting Keypad Backplate 4 F320 Instruction Manual rev 03 26 13 Gate Control O Route four wires between the gate and the keypad two for power two for control Connect the gate operator s auxiliary or radio power output terminals to the keypads POWER input
2. SS e SESS 25 SS 85 cu aS Bes USE KEY TO LOCK KEYPAD Figure 9 Locking the Keypad Case F320 Instruction Manual 9 F320 OPERATION V Users of the F320 have up to 40 seconds to key in their entry code V Up to eight seconds are allowed between each keystroke V All digits of the entry code must be entered Example If the code is 0042 the user must enter 0 0 4 2 J If the wrong key is pressed pressing the key will reset the keypad The correct code can then be re y entered After a correct code is entered the red LED will turn green and the programmed relay will activate for the y programmed time If the number of incorrect codes entered exceeds the keypad lockout count the yellow LED will light indicating that the keypad is locked out The lockout will remain for one minute After a valid code has been entered it will be unusable until the anti passback time expires YELLOW LED WILL LIGHT RED LED TURNS DURING KEYPAD LOCKOUT IF GREEN WHEN TOO MANY INCORRECT CODES ACCESS IS GRANTED ARE ENTERED Nez 0 PRESS STAR KEY TO RESET KEYPAD IF THE WRONG KEY IS PRESSED USERS HAVE UP TO 40 SECONDS TO ENTER THEIR COMPLETE CODE Figure 10 Operating F320 10 F320 Instruction Manual rev 03 26 13 GTO LIMITED TWO YEAR WARRANTY Gates That Open LLC gate openers and accessories are covered
3. Select Door Sense or Inhibit Input Default Door Sense The input on terminal block J4 terminal 3 can be programmed for DOOR SENSE or INHIBIT Press 1 0 Input Input 1 for Inhibit 0 for Door Sense When programmed for DOOR SENSE if an open condition on the input occurs before access is granted with an entry code or with the request to enter input a FORCED ENTRY output will occur If an open condition remains 60 seconds after a relay activation for access a DOOR AJAR output will occur When programmed for INHIBIT a closed condition on the input will prevent relay 1 from activating when access is requested with an entry code This mode is typically used with an external timer to disable the access device at certain times Select Forced Entry Output Default Output 3 Sets which output activates if the Door Sense input opens before access is granted This output is not timed Press 1 1 Output Output Output to Activate 0 4 1 Relay 1 2 Relay 2 3 Output 3 4 Output 4 0 No Output Select Door Ajar Output Default Output 4 Sets which output activates if the Door Sense input stays open after access is granted This output is not timed Press 1 2 Output Output Output to Activate 0 4 1 Relay 1 2 Relay 2 3 Output 3 4 Output 4 0 No Output Select Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output to sh
4. REQUEST TO ENTER INPUT rev 03 26 13 COMPONENT LOCATIONS RED GREEN POWER ACCESS INDICATOR YELLOW LOCKOUT INDICATOR 0 NIGHT LIGHT 7 TACTILE KEYPAD WIRING DIAGRAM 1721 3 Le TERMINAL BLOCK J4 POWER AND INPUTS KEYLOCK Figure 1 Component Locations TYPICAL GATE INSTALLATION WIRING rev 03 26 13 F320 1 RELAY 1 COMMON2 3 J4 ouTPUT 34 1 OUTPUT 45 2 6 1 3 INHIBIT RELAY 2 7 09 4 COMMON N C 8 O 5 REQUEST TO ENTER COMMONO 6 EARTH GROUND INHIBIT TIMER FIRE ACCESS REQUIRED WIRING AUXILIARY POWER OPTIONAL WIRING Figure 2 Wiring Diagram F320 Instruction Manual 3 JUMPER JP2 RESETS MASTER CODE TERMINAL BLOCK J3 OUTPUTS JUMPER JP1 REMOVE TO REDUCE BEEPER SOUND INSTALLATION To avoid damage to the unit from static discharges connect the EARTH GROUND terminal to a good earth grounding point Suggested wiring size is 18 AWG for earth ground and power up to 500 feet of 18 AWG wire can be run for power use larger wire for longer runs Use 22 AWG or larger depending on the load for all other connections CAUTION If the unit is AC powered and one side of the power transformer secondary is connected to earth ground connect the grounded side to the power terminal of the unit
5. FACTORY DEFAULTS MASTER PROGRAMMING 123456 ENTRY CODE 4 DIGITS REQUEST TO ENTER 0 RELAY 1 ALARM SHUNT OUTPUT DISABLED FORCED ENTRY OUTPUT 3 DOOR AJAR OUTPUT 4 RELAY 1 2 SECONDS RELAY 2 2 SECONDS SOLID STATE OUTPUT 3 ONTIME 2 SECONDS SOLID STATE OUTPUT 4 ONTIME 2 SECONDS DOOR SENSE INHIBIT INPUT DOOR SENSE KEYPAD LOCKOUT DISABLED KEYPAD ACTIVE DISABLED DOWNLIGHT 2 BEEPER SOUNDS WHEN KEY PRESSED YES BEEPER SOUNDS DURING RELAY 1 NO BEEPER SOUNDS DURING RELAY 2 NO BEEPER SOUNDS DURING OUTPUT 3 NO BEEPER SOUNDS DURING OUTPUT 4 NO KEYPAD LOCKOUT COUNT 3 TRIES BEFORE LOCKOUT NO ANTI PASSBACK BASIC PROGRAMMING When the F320 is in programming mode both LEDs will turn off until programming begins After a programming option number is entered the yellow LED will blink This indicates that the F320 is ready to accept the new programming data After
6. Output Default No Output Sets which output activates when any keys are pressed This output is timed Press 1 4 Output Output Output to Activate 0 4 1 Relay 1 2 Relay 2 3 Output 3 4 Output 4 0 No Output rev 03 26 13 Solid state Output 3 On time Default 2 Seconds Sets the length of time Output 3 activates when triggered Press 2 3 Seconds Seconds Output time in seconds 0 60 99 Toggle mode Solid state Output 4 On time Default 2 Seconds Sets the length of time Output 4 activates when triggered Press 2 4 Seconds Seconds Output time in seconds 0 60 99 Toggle mode Default 2 Minutes Sets the time duration that the downlight remains on after a key press Set Downlight On Time Press 2 5 Duration 0 Always off 1 1minute 2 2minutes 3 3 minutes 4 4 minutes 99 Always on F320 Instruction Manual 7 Default Yes Selects whether or not the keypad beeps as each key is pressed Beep Sounds on Keystrokes Press 4 0 4 Sound Sound 1 for Yes 0 Default No Selects whether or not the keypad beeps during Relay 1 activation Beep Sounds During Relay 1 Press 4 1 Sound Sound 1 for Yes 0 for No Default No Selects whether or not the keypad beeps during Relay 2 activation Beep Sounds During Relay 2 Press 4 2 Sound Sound 1 for Yes O0for No Default No Selects whether or not the keypad be
7. is housed in a rugged cast aluminum enclosure that can be mounted to a pedestal or bolted directly to a wall The die cast keys have bright easy to read yellow graphics Up to 120 entry codes from 1 to 6 digits in length can be programmed They can activate either or both of the relay outputs Relay 1 has a 5 Amp capacity Relay 2 has a 1 Amp capacity Two LED indicators show the status of the entry system The left LED lights red to indicate power then turns green when access is granted The right LED lights yellow when the keypad is in lockout condition from too many incorrect code entries The keypad s courtesy light can be always off always on or be programmed to illuminate from 1 4 minutes after any keypress default 2 minutes An internal sounder beeps when each key is pressed The DOOR SENSE INHIBIT input can be used two ways If programmed for door sense a switch on the door detects forced entry or door ajar situations If programmed for inhibit the input can be wired to a service switch or automatic timer that will disable the Relay 1 when required The REQUEST TO ENTER input can be wired to a pushbutton or fire access keyswitch to provide codeless entry for authorized personnel The anti passback feature prevents using the same code twice before the programmed time elapses The ALARM SHUNT output activates when access is granted This output can be wired to shunt alarm contacts on the access door
8. keypad Connect the power supply s output terminals to the keypad s POWER input terminals observe wiring polarity O Route two wires between the door strike and the keypad Connect one of the door strike wires to the keypad s Relay 1 N O terminal Connect the other door strike wire to the keypad s POWER terminal Connect a wire between the keypad s POWER terminal and the Relay 1 COMMON terminal If a request to enter pushbutton or fire access keyswitch is going to be used route two wires from the keypad to the normally open switch Connect the wires to the normally open switch and to the keypad s REQUEST TO ENTER and COMMON terminals O To use the door sense feature to detect forced entry or door ajar conditions install a normally closed door switch on the door and route two wires from the switch to the keypad Connect the door switch to the keypad s DOOR SENSE and COMMON terminals If an inhibit switch or timer is going to be used route two wires from the switch or timer to the keypad Connect the inhibit switch timer terminals to the keypad s INHIBIT and COMMON terminals ws NOTE Either door sense or inhibit can be used Both features cannot be used at the same time DOOR SENSE SWITCH 2 WIRES FOR DOOR SENSE 2 WIRES FOR POWER FROM ELECTRIC 2 WIRES DOOR FOR DOOR POWER STRIKE STRIKE SUPPLY Figure 6 Door Installation F320 Instruction Manual 5
9. receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help F320 Instruction Manual 11 SYSTEMS Gates That Open LLC 3121 Hartsfield Road Tallahassee Florida 32303 www gtoaccess com For online Technical Support visit the Online Troubleshooter Wizard 24 hrs day 7 days week at http support gtoinc com support troubleshooter aspx and open a Tech Ticket Technical Support Hours MON FRI 8 00AM 7 00PM ET 1 800 543 1236
10. the new data entry is complete the green LED will light while the data is being stored The red LED will light if any programming data is entered incorrectly and the command will have to be fully re entered Entering Programming Mode The 6 digit Master Programming Code default 123456 is used to enter Programming Mode Press 9 Master Code Master Code the current 6 digit Master Programming Code Exiting Programming Mode Press The red LED will light when Programming Mode is exited t NOTE The F320 will automatically exit Programming Mode after two minutes of inactivity Re entering a Command After a Mistake If the red LED lights indicating an incorrect entry or a wrong key is pressed during programming to clear the keypad and re enter the command Press 9 6 F320 Instruction Manual Setting Entry Code Length Default 4 digits Press 0 3 Length Length 1 6 for entry code length NOTE If the Entry Code Length is going to be changed from the factory default of four digits make this change first before programming any entry codes Adding a New Entry Code Press 0 1 Code Code Action Code The new entry code 1 999999 depending on code length Action Relay output entry code will activate as follows 1 Relay 1 timed open 2 Relay 2 timed open 3 Both Relays timed open 10 Relay 1 toggled 20 Relay 2 toggled 30 Both Relay
11. After the two 2 year warranty period GTO will make any necessary repairs for a nominal fee Call GTO at 800 543 1236 for more information This warranty gives you specific legal rights and you may also have other rights which may vary from state to state This warranty is in lieu of all other warranties expressed or implied NOTE Verification of the warranty period requires copies of receipts or other proof of purchase Please retain these records rev 03 26 13 FCC NOTICE Changes or modifications not expressly described in this manual or approved by the manufacturer could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the
12. SYSTEMS PROFESSIONAL RESIDENTIAL F320 Heavy Duty Digital Keypad SYSTEMS PROFESSIONAL RESIDENTI 1181 8 3 51 6 ola Gates That Open LLC 3121 Hartsfield Road Tallahassee Florida 32303 Sales 1 800 543 GATE 4283 Technical Support 1 800 543 1236 www gtoinc com Printed in China for Gates That Open LLC 2013 GTO F320 CONTENTS INTRODUCTION csssssscssssssssssssssesesssssssssssnssesssessesesssesesees 2 SPECIFICATIONG ssssssssssssssossssssssssssssssesesessssssssssesesssesesenes 2 FEATURES 2 COMPONENT 5 3 WIRING 3 1 5 4 FACTORY DEFAULTS 6 BASIC PROGRAMMING eret tntn tnn 6 PROGRAMMING OPTIONS 7 F320 OPERATION 10 GTO ACCESS LIMITED WARRANTY 11 NOTICE eere eese tenen tone tentata tatto 11 INTRODUCTION The F320 is a digital keyless entry system designed for access control applications The keypad
13. e keypad will begin to beep signaling that the code has been reset STEP 4 Replace jumper JP2 THE MASTER PROGRAMMING CODE IS NOW 123456 rev 03 26 13 Solid State Outputs The two solid state outputs Output 3 amp Output 4 can be programmed to activate during various conditions These outputs can be used to activate indicators or sounders See Figure 7 for wiring examples using the solid state outputs DC POWER source 1 Q 12 volts 2K O Q 24 volts ELECTRONIC BEEPER OUTPUT 3 EACH OUTPUT OUTPUT 4 100 mA MAXIMUM EXAMPLE 1 OUTPUT 3 LIGHTS AN LED OUTPUT 4 LIGHTS AN LED AND SOUNDS A BEEPER EACH OUTPUT 3 OUTPUT 100 mA OUTPUT 4 LOW VOLTAGE POWER MAXIMUM LAMP SOURCE END OF LINE RESISTOR COMMON GROUND COMMON EXAMPLE 2 OUTPUT 3 LIGHTS A LAMP POWERED FROM AN EXTERNAL SOURCE OUTPUT 4 TRIGGERS A NORMALLY OPEN ALARM PANEL ZONE Figure 7 Using the Solid State Outputs Beeper Sound Level The keypad s beeper can be set to low or high level If the keypad s beeper is too loud for the keypad s location remove jumper JP1 see Figure 8 REMOVE JUMPER JP1 TO REDUCE THE SOUND LEVEL OF THE BEEPER Figure 8 Removing Beeper Jumper rev 03 26 13 Locking Keypad After the installation is complete Lock the keypad using the keylock see Figure 9 aS a SS SS aS 22 53 222 SS 27225 a HOOK KEYPAD ONTO BACKPLATE
14. eps during Output 3 activation Beep Sounds During Output 3 Press 4 3 Sound Sound 1 for Yes 0 for No Default No Selects whether or not the keypad beeps during Output 4 activation Beep Sounds During Output 4 Press 4 4 Sound Sound 1 for Yes 0 for No Default 3 Tries Sets the number of incorrect entry code attempts allowed before the keypad locks out Press 5 0 Attempts Attempts Number of attempts before lockout 2 7 Keypad Lockout Count Anti passback Time Default No Anti passback Sets the length of time an entry code will not function after it is used Press 5 1 Minutes Minutes Time in Minutes 1 4 0 Anti passback 8 F320 Instruction Manual Master Reset CAUTION Performing a master reset will clear the entire memory of the F320 and return all programmable options to the factory default values ALL ENTRY CODES WILL BE ERASED STEP 1 Disconnect power from the keypad STEP 2 Press and hold down the and keys STEP 3 Apply power to the keypad continue holding the keys down until the red LED starts flashing STEP 4 Release the keys The red and yellow LEDs will remain lit until the process is complete then the yellow LED will go out Resetting the Master Code STEP 1 Open the F320 case STEP 2 Locate jumper JP2 This jumper is used to reset the master code STEP 3 With power applied to the keypad remove jumper JP2 Th
15. gate to prevent triggering of an alarm when authorized access occurs Two solid state outputs capable of switching 100 mA to common are programmable to signal forced entry door ajar lockout alarm circuit shunting request to enter and keypad active conditions The F320 is powered from a 12 24 Volt AC or DC source Power can be obtained from the access device or a separate power supply The EEPROM memory retains all entry codes and programming even without power 2 F320 Instruction Manual SPECIFICATIONS MECHANICAL Case dimensions 4 00 W x 5 50 H x 3 00 D ELECTRICAL Voltage 12 24 Volts AC or DC Current 10 mA typical 150 mA maximum Outputs Relay 1 Form C 5 Amps 24 Volts maximum Relay 2 Form C 1 Amp 24 Volts maximum Solid state outputs Outputs 3 amp 4 Short to common 100 mA 24 VDC maximum ENVIRONMENTAL Temperature 22 F to 149 F 30 C to 65 C Humidity 5 to 95 non condensing FEATURES V KEYPAD PROGRAMMABLE 120 ENTRY CODE CAPACITY 1 6 DIGIT ENTRY CODE LENGTH V 4INDEPENDENT OUTPUTS TIMED TOGGLED v 4INDEPENDENT TIMERS V EACH ENTRY CODE CAN BE PROGRAMMED TO ACTIVATE EITHER OR BOTH RELAYS V RELAY CONTACTS ARE FORM C N O amp N C V SOLID STATE OUTPUTS ARE OPEN COLLECTOR SWITCH TO COMMON V TWO LED INDICATORS COURTESY LAMP V PIEZO SOUNDER V TIMED ANTI PASSBACK LAST VALID ENTRIES V KEYPAD LOCKOUT V TACTILE KEY FEEL DOOR SENSE INPUT V INHIBIT INPUT
16. s toggled 12 Relay 1 toggled Relay 2 timed open 21 Relay 1 timed open Relay 2 toggled The yellow LED will flash quickly while the F320 searches its memory for available space and duplicate entries The green LED will light when the new code is stored If the new entry code chosen is already being used for another entry code the red LED will light A new unique code needs to be entered ts NOTE Leading zeros zeros before the code number i e 0001 do not need to be entered when programming a new entry code The F320 will internally add any zeros to fill all digits determined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Erasing a Single Entry Code Press 0 2 Code Code Code The entry code to delete The yellow LED will flash quickly while the F320 searches its memory for the code to erase The green LED will light when the code is erased Erasing All Entry Codes WARNING Performing this command will remove all entry codes from the memory Press 97 000000 000000 Code The entry code to delete NOTE The green LED will light while the memory is being erased This may take up to 15 seconds Changing the 6 Digit Master Programming Code Press 9 8 Master Code Master Code Code The entry code to delete Master Code The new 6 digit Master Programming Code New master code rev 03 26 13 PROGRAMMING OPTIONS
17. terminals observe wiring polarity L Connect the gate operator s OPEN terminals to the keypad s Relay 1 COMMON amp N O terminals NOTE For operator wiring specifics refer to the gate operator s wiring diagram If a request to enter pushbutton or fire access keyswitch is going to be used route two wires from the keypad to the normally open switch Connect the wires to the normally open switch and to the keypad s REQUEST TO ENTER and COMMON terminals O If an inhibit switch or timer is going to be used route two wires from the keypad to the inhibit switch or timer relay Connect the inhibit switch timer terminals to the keypad s INHIBIT and COMMON terminals t NOTE If the INHIBIT input is going to be used it must be programmed to select that input type See the Programming Options section of this manual GATE OPERATOR BEHIND GATE 2 WIRES FOR REQUEST TO ENTER FIRE ACCESS KEYSWITCH 2 WIRES FROM AK 11 TO TRIGGER GATE OPEN 2 WIRES FROM OPERATOR FOR F320 POWER Figure 5 Gate Installation rev 03 26 13 Door Control O Install a low voltage electric door strike for unlocking the door O Choose a location for the power supply or transformer O Route two wires between the power supply and the
18. under warranty by the manufacturer against defects in materials and manufacturer workmanship for a period of two 2 years from date of purchase provided the recommended installation procedures have been followed In the case of product failure due to defective material or manufacturer workmanship within the two 2 year warranty period the product will be repaired or replaced at the manufacturer s option at no charge to the customer if returned freight prepaid to GTO 3121 Hartsfield Road Tallahassee Florida USA 32303 IMPORTANT Call 800 543 1236 for a Return Goods Authorization RGA number before returning accessory to factory Products received at the factory without an RGA number will not be accepted Replacement or repaired parts are covered by this warranty for the remainder of the two 2 year warranty period or six 6 months whichever is greater GTO will pay the shipping charges equal to United Parcel Service GROUND rate for return to the owner of items repaired under warranty The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair or for the reinstallation of those parts after repair This warranty shall be considered void if damage to the product s was due to improper installation or use connection to an improper power source or if damage was caused by electrical power surge lightning wind fire flood insects or other natural agent
19. unt alarm contacts attached to the access door This output may be timed or latched Press 15 Output Output Output to Activate 0 4 1 Relay 1 2 Relay 2 3 Output 3 4 Output 4 0 No Output Select Request to Enter Output Default Relay 1 Sets which output activates when the Request to Enter input is grounded This output remains activated for at least the length of time specified by the On times for the relays or outputs If the Request to Enter input continues to be grounded beyond the time specified by the On times for the relays or outputs the output will remain activated as long as the Request to Enter input remains grounded Press 1 6 Output Output Output to Activate 0 4 1 Relay 1 2 Relay 2 3 Output 3 4 Output 4 0 No Output Default 2 Seconds Sets the length of time Relay 1 activates when triggered Press 2 1 Seconds Seconds Output time in seconds 0 60 Relay 1 On time Default 2 Seconds Sets the length of time Relay 2 activates when triggered Press 2 2 Seconds Seconds Output time in seconds 0 60 Relay 2 On time Select Keypad Lockout Output Default No Output Sets which output activates when the keypad is locked out after toomany incorrect entry code attempts The lockout time is 60 seconds Press 1 3 Output Output Output to Activate 0 4 1 Relay 1 2 Relay 2 3 Output 3 4 Output 4 0 No Output Select Keypad Active
Download Pdf Manuals
Related Search
Related Contents
Manual de instrucciones Ósmosis Inversa 5 ETAPAS Iron StoneTM/MC [ HKT 2000/3/2 ODF ] 9S54 取扱説明書 INSTRUCTION Copyright © All rights reserved.
Failed to retrieve file