Home
KSEI62 - MyChoice
Contents
1. ese Omeg Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es Bruksanvisning KSEI62 INDICE SOMMAIRE CONSEIES E SUGGESTIONS aA 16 CARACTERISTIQUES UTILISATION wees ENTRETIEN INHALTSVERZEICHNIS BEDIENUNG WARTUNG TANANA RAS INHOUDSOPGAVE ADVIEZEN ENSUGGES TES A 28 EIGENSCHAPPEN INDICE CONSE 05 Y SUGERENCIAS 34 CARACTERISTICAS MANTENIMIENTO NDICE CONSELHOS E SUGESTOES 40 CARACTERISTICAS 41 INSTALA O 42 44 45 aa aa nn aei aian 46 47 48 530 51 INNE
2. HALL Ea a aa aa 52 EGENSKAPER nren INSTALLATION ANVANDING ua WNDERHAL ds tara Yaar LG aay T A A ord Sepa ak a ald RECOMMENDATIONS AND SUGGESTIONS AXThe Instructions for Use apply to several versions of this appliance Accord ingly you may find descriptions of individual features that do not apply to your specific appliance INSTALLATION The manufacturer will not be held liable for any damages resulting from incor rect or improper installation The minimum safety distance between the cooker top and the extractor hood is 650 mm some models can be installed at a lower height please refer to the paragraphs on working dimensions and installation Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood For Class appliances check that the domestic power supply guarantees adequate earthing Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm The route of the flue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas burning appliances a sufficient degree of aeration must be guaranteed the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicatin
3. ast every six months or more frequently if the hood is used consistently To replace the charcoal filter support the filter with one hand remove the round disk through the centre of the charcoal filter and rotate it till the filter will come away Replace by reversing the operation WARNING It is a possible fire hazard if the filters are not cleaned and replaced as recommended Lighting LIGHT REPLACEMENT 40 W incandescent light Remove the metal grease filters e Unscrew the bulbs and replace them with new ones having the same characteristics Replace the metal grease filters
4. g directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to elimi nate kitchen smells Never use the hood for purposes other than for which ithas been designed Never leave high naked flames under the hood when itis in operation T7 650 mm min Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambe under the range hood risk of fire This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appli ance MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work Clean and or replace the Filters after the specified time period Fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recy cl
5. ing of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product CHARACTERISTICS Dimensions Components 122 Ref Q ty Product Components gt 1 1 Hood Body complete with Controls Light Blower Filters 9 1 Flange 9120 mm Ref Q ty Installation Components 7 2 2 Hood Body Fixing Brackets 7 3 2 Safety Squares 11 6 Wall Plugs 12a 6 Screws Q ty Documentation 1 Instruction Manual INSTALLATION FIXING OF THE FRONTAL PANEL TO THE VISOR Pull out the metal visor and at the same time unlock the lever on the left side of the hood Use the cardboard template when drilling the front panel Fix the panel to the visor using the screws supplied FIXING OF THE HOOD TO THE WALL Hood depth can vary from 275 to 360 mm Regulate the Vx screws when adjusting the brackets to the right depth When adjusting the lower part of the hood to the requested depth it is necessary to loose the screws of the metal distance piece and to move it as much as necessary Use the specific cardboard template when drilling the holes into the wal
6. l Put the dowels into the holes and fix the two metal brackets using the four screws supplied together with other accessories Use the specific cardboard template when drillig the side clos ets When the hood is used in ducting version it is necessary to re move the grid from the air outlet Hang the hood on the metal brackets Put back the visor again paying attention that the runners are put correctly into the proper places Adjust the visor sliding by means of the two screws Regulating the Vy screws it is possible to align the hood height compared to the closets When necessary adjust again the hood depth Place the safety squares above the fixing brackets Mark the midpoint of the holes Drill the wall and fix the safety squares together with screws and dowels supplied Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using either a flexible or rigid pipe 120 mm the choice of which is left to the installer e Fix the pipe in position using sufficient pipe clamps not sup plied e Remove any activated charcoal filters AIR OUTLET IN RECYCLING VERSION Make sure that the hood body has been completely fixed Make sure that hood is equipped with charcoal filters ELECTRICAL CONNECTION e Connect the hood to the mains through a two pole switch hav ing a contact gap of at least 3 mm e Remove the grease filte
7. rs see paragraph Maintenance being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan USE Control board 1 Lighting On off lighting system 2 Motor On off motor 3 Speed Speed control 1 Minimum speed particularly silent continuous air exchange suitable in pres ence of only few cooking vapours and odours 2 Medium speed due to an optimum relation between hood extraction capacity and the noise level it is suitable for most of the cooking conditions 3 Maximum speed suitable for the cooking conditions when vapours and smells are of the utmost emission even for a longer time OPTIONAL 4 Microswitch Microswitch which is activated by the movement of the visor It switches on and off the hood basing on the conditions which have been earlier established with the sliders of the control panel 5 Led Led indicating when the motor is on MAINTENANCE METAL GREASE FILTERS The metal grease filters should be cleaned every two months with normal usage and can be cleaned in a dishwasher or by hand us ing a mild detergent or liquid soap Removal e Open the metal grille pushing the knobs towards the centre while pulling downwards Remove the wire clips and remove the filters CHARCOAL FILTER In the recycling mode the charcoal filter absorbs smells and odours The charcoal filter cannot be cleaned and should be re placed at le
Download Pdf Manuals
Related Search
Related Contents
認証依頼書 WinTV-PVR-250 WinTV-PVR-350 安全データシート 取扱説明書 要保存 B60 W Bp 取扱い説明書 DTN DataConnect™ Jwin JX-CD1000 CD Shelf System Copyright © All rights reserved.
Failed to retrieve file