Home

Manual - Crestron

image

Contents

1. INFINET Lamp Dimmer Crestron CLF DIMRFB To exit the bootloader and restore the firmware that is currently installed cycle power to the device by setting the selection switch to OFF and back to RUN or SET Reference Documents The latest version of all documents mentioned within the guide can be obtained from the Crestron website http www crestron com manuals This link will provide a list of product manuals arranged in alphabetical order by model number List of Related Reference Documents DOCUMENT TITLE 2 Series Control Systems Reference Guide C2N MNETGW infiNET Gateway Tranceiver Further Inquiries If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning customer service team by calling the Crestron corporate headquarters at 1 888 CRESTRON 1 888 273 7876 For assistance in your local time zone refer to the Crestron website http www crestron com offices for a listing of Crestron worldwide offices You can also log onto the online help section of the Crestron website http www crestron com onlinehelp to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features Future Updates As Crestron improves functions adds new features and extends the capabilities of the CLF DIMRFB additional information may be made available as manual updates These updates a
2. 3 Return freight charges following repair of items under warranty shall be paid by CRESTRON shipping by standard ground carrier In the event repairs are found to be non warranty return freight costs shall be paid by the purchaser CRESTRON Limited Warranty CRESTRON ELECTRONICS Inc warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three 3 years from the date of purchase from CRESTRON with the following exceptions disk drives and any other moving or rotating mechanical parts pan tilt heads and power supplies are covered for a period of one 1 year touchscreen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if 1t has been subjected to misuse accidental damage modification or improper installation procedures Furthermore this warranty does not cover any product that has had the serial number altered defaced or removed This warranty shall be the sole and exclusive remedy to the original purchaser In no event shall CRESTRON be liable for incidenta
3. Hold the foot switch for approximately 10 seconds until the LED flashes twice Release the foot switch at this point and the gateway connection will have been removed A dimmer can also be released from a gateway using Toolbox Refer to the latest revision of the C2N MNETGW guide Doc 6317 for instructions Restore Default Settings To restore the dimmer s default settings press and hold the foot switch while the selection switch is in the RUN position Then while still holding the foot switch move the selection switch to the SET position and back to the RUN position Release the foot switch The factory default settings are Preset 100 Fade time 0 5 seconds Ramp rate 3 seconds Lower limit 10 LED Behavior The CLF DIMREB has a single amber LED Its behavior is determined by the current state of the dimmer or the control system program For reference the LED can be in one of three intensity levels off low and high Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e 17 INFINET Lamp Dimmer Crestron CLF DIMRFB The following table describes the LED pattern in all modes of operation LED Behavior LED BEHAVIOR DEVICE STATE Low High Four brief off blinks every eight seconds Four brief high blinks every eight seconds Two brief off blinks every eight seconds Blink off for Y second low for Y second Blink off for one second high for one second Blink off for 74 second high fo
4. 11 InfiNET Lamp Dimmer Crestron CLF DIMRFB Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features However before attempting to upload or upgrade it is necessary to establish communication Once communication has been established files for example programs or firmware can be transferred to the control system and or device Finally program checks can be performed such as changing the device ID or creating an IP table to ensure proper functioning Establishing Communication Use Crestron Toolbox for communicating with the CLF DIMREFB refer to the Crestron Toolbox help file for details There is a single method of communication indirect communication Indirect Communication C2N MNETGW InfiNET CLF DIMRFB CRESNET SERIAL CONTROL SYSTEM ETHERNET OR USB PC RUNNING CRESTRON TOOLBOX e CLF DIMRFB connects to C2N MNETGW Gateway which connects to control system via Cresnet e Establish communication between the PC and the control system as described in the latest version of the 2 Series Reference Guide 12 e infiNET Lamp Dimmer CLF DIMRFB Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET Lamp Dimmer Doc 6256 which 1s available from the Crestron website http www crestron com manuals Programs and Firmware e Display the network device tree Tools Netwo
5. Crestron CLF DIMRFB IniNET Lamp Dimmer Operations Guide This document was prepared and written by the Technical Documentation department at T CRESTRON Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2007 Crestron Electronics Inc Crestron CLF DIMRF infiNET Lamp Dimmer Contents InfiNET Lamp Dimmer CLF DIMRFB 1 A torent nares areas cen de ie ele eee on te the et l Featutessand FONCIONS aaa l O A maser ey cee earn te es l Physical DESCrI PONa a den a a a de ne 3 Indust Comp AICS AA 5 A POES POE I IIT E ee ee ee E PAAA E A EEE TAE O OE ET 6 A e a a net REE ey eRe ne ees 6 Hardware Tl OOK UD ics adios 6 PLOSTAMINING SOWIE NAAA AA eet 8 Earliest Version Software Requirements for the PC 8 Programming with Crestron D3 Pro or SystemBuilder nnn00000000000000000000000000000se 9 Programming with SIMPL Windows 9 Uploading and Upgrading sereine tenue 12 EStabliSi mies Communicati las 12 Programs and FIWA E Gena ti 13 ODOT aaa r a ame Ne ate eer ge a E E ee ee 14 D e eE E i E EE O A E E E E E Dion 14 S Fl RUB E 1 o A E ITE AE E EIN D mes 16 Proper ONI 10 n D 19 Troubleshoot ini eas a T T N 19 BONO Alca 21 Reference DOCUMENTS aa das 22 a le ters 22 A ner een tere ene rene ter 22 RETA Warranty PONCICS cas 23 Merchandise Returns Repair Service ss 23 CRESTRON Limited Wat i
6. all Dimensions Top view a 3 69 in cc Ce 6 LONG RIGHT ANGLE AC PLUG 3 CONDUCTOR Connectors Controls amp Indicators CONNECTORS DESCRIPTION CONTROLS amp INDICATORS AC Receptacle Plug table floor lamp in here ungrounded Foot Switch Operates dimmer LED Indicator Provides feedback Selection Switch Three position switch sets mode of operation AC Plug Connects to 120V AC power source Refer to Operation on page 14 4 e infiNET Lamp Dimmer CLF DIMRFB Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET _ Lamp Dimmer Industry Compliance This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc Us E239013 As of the date of manufacture the CLF DIMRFB has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling CEC NOTE This device complies with part 15 of the FCC rules Operation 1s subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are
7. arliest Version Software Requirements for the PC NOTE Crestron recommends that you use the latest software to take advantage of the most recently released features The latest software is available from the Crestron website Crestron has developed an assortment of Windows based software tools to develop an infiNET system The following are the minimum recommended software versions for the PC Software TASK REQUIRED SOFTWARE VERSION Program control system SIMPL Windows version 2 06 20 to operate CLF DIMRFB or later with SIMPL 9 Cross Compiler version 1 1 or later and Library update 382 or later Also requires Crestron Database version 18 1 0 or later Upload program and Crestron Toolbox 1 02 25 or later firmware Continued on following page 8 e infiNET Lamp Dimmer CLF DIMRFB Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET Lamp Dimmer Configuration Manager Software Continued TASK REQUIRED SOFTWARE VERSION Program with simple Crestron D3 Pro version 2 0 6 or wizards for lighting later or SystemBuilder version systems using a 2 0 6 or later Refer to software CLF DIMRFB optional release notes or Crestron website but recommended for other required Crestron software packages Programming with Crestron D3 Pro or SystemBuilder Crestron D3 Pro and SystemBuilder are the easiest methods of programming but do not offer as much flexibility as SIMPL Windows For additional details do
8. ction switch is in Move the selection not store the incorrect position switch to the SET position raise or lower the load level with the foot switch then switch to the RUN position to store the preset Cannot Selection switch is in Move the selection recall preset the incorrect position switch to the RUN light position to recall settings preset Press foot switch to toggle between preset level and off Bootloader In rare cases it may be necessary to bypass the dimmer s standard firmware and enter into the bootloader This might be necessary if the unit was loaded with a faulty version of firmware that might prevent future firmware upgrades To enter the bootloader move the selection switch to OFF Press and hold the foot switch while setting the selection switch to RUN The LED will blink once after five seconds to indicate the start of Acquire mode Acquire mode does not actually start until you release the foot switch Continue holding the foot switch for another five seconds and the LED will flash twice to indicate that the gateway connection will be released on the release of the foot switch Continue holding the foot switch an additional ten seconds twenty seconds in all until the LED flashes three times Then release the foot switch The unit is now running the bootloader New firmware can now be uploaded from the Crestron Toolbox Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e 21
9. designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and 1f not installed and used in accordance with the instructions may cause harmful interference to radio communications However there 1s no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures m Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver m Connect the equipment into an outlet on a circuit different from that to which the receiver 1s connected n Consult the dealer or an experienced radio TV technician for help Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e 5 InfiNET Lamp Dimmer Crestron CLF DIMRFB Setup Identity Code The MNET ID of the CLF DIMRFB has been factory set to 01 After an infiNET device is added to an infiNET network its MNET ID must be changed to a value that can be addressed by the control system program 03 to 20 The MNET IDs of multiple CLF DIMRFB devices in the same system must be unique MNET IDs are changed from a personal computer PC via the Crestron Toolbox When setting the MNET ID consider the f
10. ection switch is in the RUN position NOTE To recall a preset light level move selection switch to the RUN position without pausing at the SET position RUN Functions EVENT ACTION RUN position Recall last load state entered from OFF position RUN position Store the current load level to the entered from SET preset level Refer to SET Functions position on next page Cannot save 0 Any level less than 10 will store as 10 Continued on following page 14 e infiNET Lamp Dimmer CLF DIMRFB Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET Lamp Dimmer RUN Functions Continued EVENT ACTION Foot switch is pressed SET Toggle between the preset level and off using the following rule If load is currently off recall preset otherwise turn load off When the selection switch is in the SET position the desired preset level can be adjusted The LED will blink between off and low every 2 second to indicate that the dimmer is in the SET position Refer to the following table for a list of available functions when the selection switch 1s in the SET position NOTE Selection switch must be in the SET position for at least 0 5s for unit to accept a new preset SET Functions EVENT ACTION SET position entered from OFF or RUN position Foot switch is pressed Enables the device to set and store a preset level LED will blink at a steady rate while in this pos
11. foot switch while sliding the selection switch to the RUN position c Continue holding the foot switch until you see the LED blink once Now release the foot switch the unit is now in Acquire mode NOTE Acquire mode does not actually start until the foot switch is released After approximately 10 seconds the LED will start to blink slowly and the dimmer will attempt to acquire with a C2N MNETGW that is in the Acquire mode The device is acquired then the LED stops blinking Acquiring can take up to five minutes to complete After being acquired the device will exit the Acquire mode 3 Take the C2N MNETGW out of the Acquire mode by pressing ACQUIRE once all devices have been acquired Refer to the latest revision of the C2N MNETGW guide Doc 6317 16 e infiNET Lamp Dimmer CLF DIMRFB Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET Lamp Dimmer To communicate with the control system program an MNET ID value between 03 and 20 must be assigned to the dimmer Refer to Identity Code on page 6 Release Gateway Connection In some cases it might be desirable to release a dimmer from a gateway If a dimmer is to be released from a gateway the gateway information must be cleared from the dimmer s memory To clear a dimmer s gateway information 1 Move the selection switch to the OFF position 2 Press and hold the foot switch on the CLF DIMRFB while sliding the selection switch to the RUN position 3
12. i 23 Operations Guide DOC 6479A Contents e i Crestron CLF DIMRFB infiNET Lamp Dimmer InfiNET Lamp Dimmer CLF DIMRFB Introduction Features and Functions Free standing dimmer module designed to sit on the floor Provides control of a conventional floor lamp or table lamp toggling between on at a user preset level and off Enables local dimming control via a built in foot switch Crestron System Integration via infiNET Wireless Network Specifications Specifications for the CLF DIMRFB are listed in the following table CLF DIMRFB Specifications SPECIFICATION DETAILS Load Ratings 500 Watts VA Incandescent Tungsten Halogen Magnetic Low Voltage Power Requirements 120 Volts AC 60Hz Default MNET ID 01 Continued on following page Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e 1 INFINET Lamp Dimmer Crestron CLF DIMRFB CLF DIMRFB Specifications Continued SPECIFICATION DETAILS Minimum 2 Series Control Version 3 154 or later System Update File Wireless RF Transceiver 2 way RF 2 4 GHz ISM Channels 11 26 2400 to 2483 6 MHz IEEE 802 15 4 compliant RF Output Power 10mW Range typical 150 feet indoor 250 feet outdoor subject to site specific conditions range is increased by adding additional devices Environmental Temperature 32 to 104 F 0 to 40 C Humidity 10 to 90 RH non condensing Enclosure Free standing black metal with high impact i
13. ition refer to LED Behavior on page 17 Manually raise or lower the load level using the current ramp time parameter The behavior will be alternating releasing the button and pressing it again will cause the lights to ramp in the opposite direction Switch to RUN position to store preset User can abort any changes made in SET position by switching unit OFF before returning to RUN Fade time and ramp time are parameters that can be changed in SIMPL Windows Refer to the SIMPL Windows help file F1 for details Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e 15 INFINET Lamp Dimmer Crestron CLF DIMRFB Special Functions Enter Acquire Mode Before an infiNET device can be used on an infiNET network it must first be acquired by a C2N MNETGW gateway that is connected to a Cresnet network NOTE A dimmer can be acquired by only one gateway To acquire a CLF DIMRFB by a C2N MNETGW perform the following 1 Put the C2N MNETGW in the Acquire mode from the unit itself or from Toolbox as described in the latest revision of the C2N MNETGW guide Doc 6317 which 1s available from the Crestron website The gateway ACQUIRE LED lights NOTE In environments where multiple gateways are installed only one gateway should be in Acquire mode at a time 2 Place the CLF DIMRFB in the Acquire mode by doing the following a Move the selection switch to the OFF position b Press and hold the
14. l or consequential damages of any kind property or economic damages inclusive arising from the sale or use of this equipment CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party CRESTRON shall at its option repair or replace any product found defective without charge for parts or labor Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty Except as expressly set forth in this warranty CRESTRON makes no other warranties expressed or implied nor authorizes any other party to offer any warranty including any implied warranties of merchantability or fitness for a particular purpose Any implied warranties that may be imposed by law are limited to the terms of this limited warranty This warranty statement supersedes all previous warranties Trademark Information All brand names product names and trademarks are the sole property of their respective owners Windows is a registered trademark of Microsoft Corporation Windows95 98 Me XP Vista and WindowsNT 2000 are trademarks of Microsoft Corporation Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e 23 T CRESTRON Crestron Electronics Inc Operations Guide DOC 6479A 15 Volvo Drive Rockleigh NJ 07647 2014965 Tel 888 CRESTRON 04 07 Fax 201 767 7576 Specifications subject to www crestron com change without notice
15. llowing page Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e 19 INFINET Lamp Dimmer Crestron CLF DIMRFB CLF DIMRFB Troubleshooting Continued TROUBLE Dimmer does not respond to control system commands POSSIBLE CAUSE S lf the LED blinks off for 4 second four times then returns to low every eight seconds the dimmer is not currently communicating with a C2N MNETGW If the LED blinks off for 4 second two times then returns to low every eight seconds the MNET ID of device or the gateway ID is not set to match the MNET ID of the SIMPL Windows program Continued on following page 20 e infiNET Lamp Dimmer CLF DIMRFB CORRECTIVE ACTION Open Crestron Toolbox and select the Network Device Tree Expand the tree until the gateway to be managed is selected Right click the NET ID of the selected gateway to open the sub menu and select Functions MNET Gateway If devices are not listed acquire the device to the infiNET network as described in Enter Acquire Mode on page 16 Use the Network Device Tree infiNET network in Crestron Toolbox to poll the INfINET network Verify that the MNET ID for the infiNET device is set to match the MNET ID specified in the SIMPL Windows program Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET Lamp Dimmer CLF DIMRFB Troubleshooting Continued TROUBLE POSSIBLE CORRECTIVE CAUSE S ACTION Preset will Sele
16. njection molded plastic footswitch Dimensions Height 2 38 in 6 03 cm Width 3 15 in 8 01 cm Depth 3 69 in 9 37 cm Weight 14 46 oz 410 g Available Accessories C2N MNETGW INfINET Gateway Transceiver 1 Requires set up with Crestron Toolbox 2 The latest software versions can be obtained from the Crestron website Refer to the NOTE following these footnotes 3 Crestron 2 Series control systems include the AV2 and PRO2 Consult the latest Crestron Product Catalog for a complete list of 2 Series control systems 4 C2N MNETGW gateway transceiver required NOTE Crestron software and any files on the website are for authorized Crestron dealers and Crestron Authorized Independent Programmers 2 e infiNET Lamp Dimmer CLF DIMRFB Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET Lamp Dimmer CAIP only New users may be required to register to obtain access to certain areas of the site including the FTP site Physical Description This section provides information on the connections controls and indicators available on your CLF DIMRFB CLF DIMRFB Physical View CLF DIMRFB Overall Dimensions Front view 3 15 in 8 01 cm s 0 54 in J asym ooo 2 29 in ommen 2 38 in 6 03 cm i o Y y Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e 3 INFINET Lamp Dimmer Crestron CLF DIMRFB CLF DIMRFB Over
17. ollowing e The MNET ID of each unit must match an ID code specified in the SIMPL Windows or D3 Pro SystemBuilder program e Each network device must have a unique MNET ID For more details refer to the Crestron Toolbox help file Hardware Hookup Make the necessary connections as called out in the illustration that follows this paragraph Apply power after all connections have been made When making connections to the CLF DIMRFB consider the following e The included cable cannot be extended e Do not use an extension cord 6 e infiNET Lamp Dimmer CLF DIMRFB Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET Lamp Dimmer Hardware Connections for the CLF DIMRFB a D Pl po TO ANY 120V AC 60Hz POWER SOURCE 60H2 SOOVA MAX j TO LAMP DIMMER Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e 7 INFINET Lamp Dimmer Crestron CLF DIMRFB Programming Software Have a question or comment about Crestron software Answers to frequently asked questions FAQs can be viewed in the Online Help section of the Crestron website To post a question or view questions you have submitted to Crestron s True Blue Support log in at http support crestron com First time users will need to establish a user account E
18. r second In RUN position operating normally Device is in the bootloader Refer to Bootloader on page 21 for more information In RUN position but there is no communication with a gateway Device failed to acquire with a gateway In RUN position and communicating with a gateway but the dimmer is not addressed in a control system program In SET position The dimmer is in the Acquire mode and searching for a gateway This touch settable device is waiting for user to press a button to identify it 1 Refer to Enter Acquire Mode on page 16 2 Refer to the Crestron Toolbox help file 18 e infiNET Lamp Dimmer CLF DIMRFB Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET Lamp Dimmer Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations If further assistance is required please contact a Crestron customer service representative CLF DIMRFB Troubleshooting TROUBLE POSSIBLE CAUSE S CORRECTIVE ACTION Dimmer Dimmer is notreceiving Verify that dimmer is does not AC power properly plugged into function an AC outlet and that the circuit breaker is closed Load is not connected Verify that load is operational and that the selection switch is not in the OFF position Dimmer selection switch is in Move the selection does not the SET position switch to the RUN function as position expected Continued on fo
19. re solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision Check the Crestron website periodically for manual update availability and its relevance Updates are identified as an Addendum in the Download column 22 e infiNET Lamp Dimmer CLF DIMRFB Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET Lamp Dimmer Return and Warranty Policies Merchandise Returns Repair Service 1 No merchandise may be returned for credit exchange or service without prior authorization from CRESTRON To obtain warranty service for CRESTRON products contact an authorized CRESTRON dealer Only authorized CRESTRON dealers may contact the factory and request an RMA Return Merchandise Authorization number Enclose a note specifying the nature of the problem name and phone number of contact person RMA number and return address 2 Products may be returned for credit exchange or service with a CRESTRON Return Merchandise Authorization RMA number Authorized returns must be shipped freight prepaid to CRESTRON 6 Volvo Drive Rockleigh N J or its authorized subsidiaries with RMA number clearly marked on the outside of all cartons Shipments arriving freight collect or without an RMA number shall be subject to refusal CRESTRON reserves the right in its sole and absolute discretion to charge a 15 restocking fee plus shipping costs on any products returned with an RMA
20. ree of the control system displays the device in the appropriate slot with a default MNET ID as shown in the following illustrations C2Net Device Slot 9 E A PROZ pu Slot 1 Empty C2 Card Slot 2 Slot 2 Empty C2 Card Slot 3 Slot 3 Empty C2 Card Slot HE Slot 4 C2I COME HEE Slot 6 C21 108 FES Slot 7 C2I R YE i Slot 8 Empty C2Z Card Slot BE Slot 9 C Net Device EB 10 oF C2N MNETGW E Eh MNET ID 03 CLF DIMRE ff Slot 10 C21 PRO2 LODPANEL e Additional CLF DIMRFB devices are assigned different MNET ID numbers as they are added e If necessary double click a device to open the Device Settings window and change the MNET ID as shown in the following figure 10 e infiNET Lamp Dimmer CLF DIMRFB Operations Guide DOC 6479A Crestron CLF DIMRFB infiNET Lamp Dimmer CLF DIMRFB Device Settings Window Device Settings Crestron CLF DIMRF AFAR ID Connection Sheet Device Info AFAR os e The ID code specified in the SIMPL Windows program must match the MNET ID of each unit is rogramming Programming Manager is the view where programmers program a anager g Crestron control system by assigning signals to symbols The symbol can be viewed by double clicking on the icon or dragging it into Detail View A description for each signal in the symbol 1s described in the SIMPL Windows help file F1 Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e
21. rk Device Tree to show all network devices connected to the control system Right click on the CLF DIMREFB to display actions that can be performed on the CLF DIMRFB gt gt Upgrade firmware gt Change MNET ID e Upload the SIMPL Windows file to the control system using SIMPL Windows or Crestron Toolbox e Upgrade CLF DIMRFB firmware via Crestron Toolbox Establish communication with the CLF DIMREB and display the System Info window gt Select Functions Firmware to upgrade the CLF DIMREB firmware For details on uploading and upgrading refer to the SIMPL Windows help file or the Crestron Toolbox help file Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB e 13 InfiNET Lamp Dimmer Crestron CLF DIMRFB Operation The CLF DIMRFB may be warm to the touch during operation This is normal Selection Switch These dimmers use a three position selection switch to set the mode of operation OFF When the selection switch is in the OFF position the foot switch will not have any function and the load is disconnected from the power source This must be used when changing light bulbs to ensure that the load is fully disconnected from power RUN The RUN position of the selection switch is the normal position for operating the dimmer When the selection switch is in the RUN position the preset light level can be recalled Refer to the following table for a list of available functions when the sel
22. wnload D3 Pro or SystemBuilder from the Crestron website and examine the extensive help files Programming with SIMPL Windows NOTE While SIMPL Windows can be used to program the CLF DIMREB it is recommended to use D3 Pro or SystemBuilder for configuring system SIMPL Windows is Crestron s premier software for programming Crestron control systems It is organized into two separate but equally important Managers Configuration Manager 1s the view where programmers build a Crestron control system by selecting hardware from the Device Library e To incorporate the CLF DIMRFB into the system first drag the C2N MNETGW MNET Gateway from the Wireless Receivers Wireless Receivers RF folder of the Device Library and drop it in the System Views Then drag the CLF DIMRFB from the Lighting Wall Dimmers Switches infiNET CLW Series folder of the Device Library and drop it on the C2N MNETGW Operations Guide DOC 6479A infiNET Lamp Dimmer CLF DIMRFB 9 INFINET Lamp Dimmer Crestron CLF DIMRFB Locating the C2N MNETGW in the Device Library Y Crestron Devices DwcLib 382 H Control Systems a Wireless Receivers EU wireless Receivers IF ERGY wireless Receivers RF EA CON MNETGW Locating the CLF DIMRFB in the Device Library Y Crestron Devices DwcLib 382 H Control Systems A E Lighting BR Wall Dimmers Switches infiNET CLw le CLF DIMRF QL CLW DIMIRF QL CLW DIM4RF e The system t