1. Removing the DFC 1 Shut down the NAM II For more information refer to Shutting down the NAM II on page 29 Remove the power cord from the AC outlet Open the NAM II door and remove the front cover Refer to Accessing the inside of the NAM II on page 30 Locate the DFC in slot 8 Remove its slot cover screw Refer to Figure 35 on page 59 Disconnect the PEB Cable from the DFC Carefully hold the DFC with both hands along the top Lift the DFC straight up and out from the module Sometimes the DFC is tightly seated and hard to remove You may need to wiggle it out with a slight rocking motion Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing the Digital Fax Card DFC 47 Figure 27 Removing the DFC Installing the DFC expansion card 1 Align the two connectors on the expansion card with the connectors on the DFC and press the two boards together 2 Use the screws provided to fasten the expansion card to the DFC Figure 28 Installing the DFC expansion card Expansion Card Connectors Base Card Expansion Card 3 Insert the DFC into its slot Refer to Installing the DFC on page 40 4 Reconnect t
2. Video card post screw holes Video card posts Microprocessor heatsink 10 11 12 13 14 15 Lightly press the video card down into the video card connectors on the SBC The video card posts should be flush with the video card post screw holes on the SBC Also the SBC video card posts should line up with the screw holes on the video card Before pressing down on the video card ensure the male video card connectors line up with the female video connectors on the SBC Fasten the metal slot cover to the SBC using the two larger screws provided Using two of the four remaining screws fasten the video card to the two video card posts on the SBC Gently turn the SBC over and place it on a flat surface The microprocessor heat sink should be facing down Note Failure to place the SBC on a flat surface may result in serious damage to the SBC While the SBC is out of the NAM II be careful not to slide or catch the front or back of the SBC this may cause the modules on the SBC to become damaged Locate the remaining video card post screw holes on the back of the SBC Using the remaining two screws fasten the SBC to the video card Installation and Maintenance Manual Norstar Applications Module II NAM II 92 Adding and removing a monitor keyboard and mouse CAUTION Do not apply downward pressure to the SBC while fastening the screws Pressure
3. Press ADMIN Press NEXT until the display shows Press SHOW Press OK Press to end this session Norstar Applications Module Il NAM II 134 Using the ACCESS Server administration software from a telephone set Shutting down the NAM Il This option allows you to gently shutdown the NAM II OS 2 Warp requires a controlled shutdown to guarantee the integrity of the file system Three shutdown options are available Graceful Quick and Immediate The Graceful option allows an application to terminate all existing calls before shutting down The Quick option only allows 45 seconds for an application to terminate before shutdown and the Immediate option only allows 15 seconds When you are shutting down the NAM II you will usually use the Graceful option However if the system is not responding to the command you can speed up the process by changing the option to a Quick shutdown After 45 seconds a Quick shutdown is performed To shutdown the NAM II 1 Press Feature 9 fa 5 Password 2 Enter the default password 2 2 J 2 3 7 7 J 2 LITITITI TI PRETRY_ ACCESS2 ACCESS Server 3 Press NEXT em shutdown 4 Press SHOW down type 5 Press GRAC Note Press NEXT to change the shutdown option to QUI CK Quick or MMD Immediate 6 Press YES Note Press NO if you want to stop
4. Norstar Voice Mail and Automatic Call Distribution Interactive Voice Response ACD Settings Settings COM COM IRQ IRQ Sy oy By w BB WN e e Sy aj A w A Ww N e 4 Locate slot 3 5 Carefully hold the internal modem card along the top Insert the card by aligning it between the metal groove on one side and the slot opening on the other side 6 Gently push the internal modem straight down and back with the two teladapt jacks facing forward until it fits snugly in place Norstar Applications Module II NAM II Installation and Maintenance Manual Installing a new Internal modem 77 Figure 41 Inserting the internal modem 7 Fasten the slot cover screw in the modem slot cover 8 Reconnect the Serial Port A and Serial Port B connectors to the SBC Reconnect the keyboard mouse connector to the SBC Refer to Figure 43 on page 80 for the location of the connectors Note Ensure the keyboard mouse ribbon cable is still connected to the backplane 9 Replace the front cover Installation and Maintenance M anual Norstar Applications Module Il NAM II 78 Installing a new Internal modem Connecting the internal modem to an Analog Terminal Adapter ATA Once the new internal modem is installed you must connect it to the ATA or a Central Office CO line To connect the internal modem
5. 2 Press and then press Reurn The screen shows Allocate Channels to Applications Choice of Applications 1 ACCESS Server 2 NrstrVM Q Quit Enter Selection Number 3 Enter the Application you want to assign Channels to and then press Reurn The screen shows Voice and Fax Channel Allocation 1 Minimum number of Voice Channels 2 Maximum number of Voice Channels 3 Maximum number of Fax Channels Q Quit Enter Selection Number 4 Enter the type of allocation and the number of Channels you want allocated Norstar Applications Module II NAM Il Installation and Maintenance Manual Using the ACCESS Server administration software from a terminal 119 5 Press Q and then press Reum to return to the ACCESS Server Administration Menu Installing and removing applications The application Installation De installation option is used to e install applications onto the hard drive e remove applications from the hard drive The installation includes copying all the required files into the appropriate directories Before you can access the Installation De installation option the ACCESS Server Administration Menu must appear on your monitor For more information about accessing the Server Administration software refer to Administering an application on page 115 To access the Installation De installation option 1 Press to select Installation De installation and then press Reurn The screen sh
6. 88 Adding and removing a monitor keyboard and mouse Figure 46 Installing the video card 8 Push the card straight down until it fits snugly in place Ensure the edge connector is firmly inserted into the backplane connector 9 Fasten the slot cover screw 10 Using a small screwdriver you must set dip switch 8 on the side of the SBC to off in order to activate the video card Refer to Table 6 for information about the SBC dip switch settings Table 6 Setting the SBC dip switches for SVGA activation Position 1 2 3 4 5 6 7 8 9 State off off off on on on on off off Note To set a dip switch to off the switch must be up and point away from the SBC To set a dip switch to on the switch must be down towards the SBC Refer to Figure 48 on page 90 for the location of the SBC dip switches 11 Replace the front cover Norstar Applications Module Il NAM Il Installation and Maintenance Manual Adding and removing a monitor keyboard and mouse 89 To connect the monitor keyboard and mouse to the NAM II 12 Plug the monitor keyboard and mouse cables into the appropriate ports Refer to Figure 47 for the location of each port The monitor will plug into the bottom of slot 8 Figure 47 Module external points of connection O O Keyboard M o
7. Gently push the SIMM up into the clips The clips should snap onto the sides of the SIMM Carefully hold the SBC along the top Insert the card by aligning it between the metal groove on one side and the slot opening on the other side Push the SBC straight back until it fits snugly in place Ensure the edge connector is firmly inserted into the backplane socket refer to Figure 44 Reconnect the Serial Port A and Serial Port B connectors to the SBC Reconnect the keyboard mouse connector to the SBC Refer to Figure 34 on page 57 for the location of the connectors Note Ensure the keyboard mouse ribbon cable is still connected to the backplane Reconnect the reset and speaker two brown connectors to the side of the SBC Reconnect the three ribbon cable connectors near the top of the SBC Refer to Figure 43 on page 80 for the proper alignment of the connectors Fasten the slot cover screw Replace the front cover Norstar Applications Module Il NAM Il Installation and Maintenance Manual Adding and replacing memory 83 18 Plug the power cord into the AC outlet The NAM II will reboot and then automatically reboot a second time The second reboot is necessary for the NAM II to recognize the addition of memory Removing memory SIMMs are usually only removed when a failure is suspected To remove a SIMM l Shutdown the module For more information refer to Shutting down the NAM II on page 29 Remove the NA
8. 1 If you are not using an ATA connect the CO line to the Line teladapt jack on the internal modem 2 If you are using an ATA connect the teladapt cord from the ATA Phone teladapt jack to the Line teladapt jack on the internal modem 3 Close the cable trough door 4 Plug the power cord into the AC outlet and wait for the system to boot before attempting to test the modem Figure 42 Connecting to the ATA AV 24 VAC 16VA ATA Phone teladapt jack Internal modem teladapt jack To KSU port Norstar Applications Module II NAM Il Installation and Maintenance Manual Adding and replacing memory 1 1 Overview The NAM II is equipped with either 8 MB or 16 MB of EDO Random Access Memory RAM This memory is located in Single In line Memory Modules SIMMs on the SBC The first 8MB SIMM is located in memory slot 1 If the NAM II is equipped with 16 MB of RAM there will an additional 8 MB SIMM in memory slot 2 When the NAM Ilis mounted on a wall the SIMMs are on the upper left corner of the SBC For information about the location of the SIMM slots refer to Figure 44 on page 82 Adding memory You may want to increase the amount of RAM depending on the applications running on the NAM II You can expand the amount of RAM to e 16 MB with an extra 8 MB in SIMM slot 2 e 32 MB with 8 MB SIMMs in all four slots Note Before you begin installing additional
9. 86 Adding and replacing memory Norstar Applications Module II NAM Il Installation and Maintenance Manual Adding and removing a monitor 1 2 keyboard and mouse Overview A 14 inch color monitor a keyboard and a mouse can be added to the NAM II to allow the use of other Nortel approved software applications on the NAM II The monitor comes with a Super Video Graphic Array SVGA card Installing the SVGA video card This procedure is for installing an SVGA on a NAM II that does not have Norstar Voice Mail installed The SVGA video card provides high text and graphic resolution and can display up to 256 colors To install the video card 1 Shutdown the module For more information refer to Shutting down the NAM II on page 29 Remove the NAM II power cord from the AC outlet Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface Remove the NAM II front cover Refer to Removing the front cover on page 31 Unpack the video card from the shipping container and antistatic bag Inspect for damage Handle the board by its edges at all times Do not touch any card components Locate expansion bus slot 8 and remove its slot cover screw and metal slot cover Carefully hold the card along the top only and insert the card into the module by aligning it over the backplane connector Installation and Maintenance M anual Norstar Applications Module Il NAM II
10. It is approximately equivalent to Bits Per Second BPS Typical baud rates are 300 1200 2400 4800 and 9600 Bit An abbreviation for Binary Digit A bit is the smallest unit of information recognized by the computer A bit has one of two values 0 or 1 to indicate off or on BIOS Basic Input O utput System A program contained in Read Only Memory ROM that acts as the interface between software programs and the computer hardware BPS Bits Per Second The speed of data transmission between two computers Bus A collection of communication lines that carry electronic signals either between elements on the system board or between the circuitry on the system board and any cards plugged into the system board Byte The amount of space required to store a single character One byte equals eight bits Installation and Maintenance M anual Norstar Applications Module Il NAM II 150 Glossary CD ROM Compact Disc Read Only Memory The CD ROM drive and the accompanying CD ROM disk are used to upgrade the system software Conventions The way certain information is described For example using underlined text to represent second line display prompt information Default The parameters that are preset within the NAM IL Disk drive A mass storage device that seeks reads and writes data on a disk Diskette A removable magnetic disk used to store data Display A one line or two line screen on a Norstar telephone that s
11. initialized and enabled Note Steps 9 and 10 are part of a first time monitor initialization process If the monitor keyboard and mouse are removed from the NAM II only steps 1 through 8 need to be performed to re enable the monitor package Norstar Applications Module II NAM Il Installation and Maintenance Manual Adding and removing a monitor keyboard and mouse 95 Removing the monitor keyboard and mouse If you remove the monitor keyboard mouse and SVGA card you must first disable the monitor package This is necessary for the NAM II software to recognize the removal of the components To remove the monitor keyboard and mouse 1 Press 2 Enter the ACCESS password Password PIPE I TS PP RETRY Note The default password is ACCESS2 2223772 Access Server 3 Press ADMIN BACK J NEXT ADMIH A Prtfqgueuejfmgr 4 Press NEXT until the display shows TI NEXT SHOW J G Moni torf Pkg G Monitor Pkg 5 Press SHOW QUI Tf NEXT f SHOW Pi Password 6 Enter the default password QUITSJII JIRETRY J EEEIEE SVGANEEDED Monitor 7 Press REM ou T ADD REM Reboot fneeded 8 Shutdown the Norstar Voice Mail system For more information refer to Shutting down the NAM II on page 29 9 Remove the NAM II power cord from the AC outlet 10 Remove the monitor keyboard mouse and SVGA card 11 P
12. 3 Fasten the bracket to the backboard Use two 10 X 2 5 cm 10 X 1 inch round head wood screws through the inner pair of holes Figure 8 The NAM II mounting bracket 4 Slide the NAM II down onto the center bracket flange Line up the notches on the far sides of the bracket to the flanges on the NAM II 5 Open the front cable trough door Fasten the bottom of the NAM II to the backboard Use two 10 X 2 5 cm 10 X 1 inch round head wood screws through the screw holes on each side of the cable trough Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing the NAM II 19 Figure 9 Hanging the NAM II Figure 10 Installing the cable trough screws Installation and Maintenance M anual Norstar Applications Module Il NAM II 20 Installing the NAM Il Floor mount stand The floor mount stand is an alternative to wall mounting the NAM II The stand allows the module to sit on any horizontal surface The floor mount stand is useful when you are attaching a monitor and keyboard to the NAM II and want it situated near a desk CAUTION Refer to Environment Checklist and Electrical Checklist on page 16 for acceptable environmental and electrical conditions before selecting a location for the NAM II Assembling the floor mount stand Before you can attach the floor mount stand to the NAM II you must first assemble the stand
13. 4 Chapter 5 Chapter 6 Preparing for the upgrade 27 Overview 27 Special tools 28 Shutting down the NAM II 29 Accessing the inside of the NAM II 30 Removing the front cover 31 Opening the cable trough 32 Removing the plastic case 32 Overview 35 Removing and replacing the battery 35 Installing the clock calendar battery 35 Overview 39 Installing the Digital Fax Card DFC 39 Precautions 40 Installing the DFC 40 Connecting the DFC to the DVCs with the PEB Cable 42 Upgrading the DFC 46 Installing the DFC expansion card 47 Removing fax functionality from the System 48 Overview 51 Increasing the number of Voice Channels 51 Types of DVCs 51 Norstar Applications Module Il NAM Il Installation and Maintenance Manual Chapter 7 Chapter 8 Chapter 9 Chapter 10 Chapter 11 Chapter 12 Installing and upgrading the Digital Voice Cards DVC s 51 Installing the second third or fourth DVC 52 Connecting a DVC to the distribution block 55 Installing the first DVC 56 Removing the second third or fourth DVC 58 Removing the first DVC 60 Adding a DVC after a DFC is installed 62 Overview 65 Installing a new floppy disk drive 65 Installing a new floppy disk drive 65 Overview 67 Backing up the NAM II capabilities file 67 Installing and upgrading the hard disk drive 67 Removing the hard disk drive 68 Installing a new hard disk drive 70 Restoring the NAM II capabilities file 71 Adding a secondary hard
14. Cable trough door 30 Cable trough opening 32 Capabilities file Backing up 67 Case 32 Caution symbol 2 Changing printer options 116 Channel status 142 Channels 5 51 Allocating 130 Disabling 145 Re enabling 146 Channels Voice 15 51 Checking the Channel status 142 Clock calendar removing 35 Components 30 Components hardware 6 Connecting a DVC 55 Connecting remotely 110 Connecting to the KSU 22 Conventions and symbols 2 Current Maximum 16 Nominal 16 D DB 25 pin 10 Connector 10 DFC expansion card installing 47 Diagnosing 140 Diagnostics 124 Server 124 Digit duration length 128 Digital Fax Card DFC DFC expansion 47 Expansion bus slot 40 Installation precautions 40 Installing 40 Installing PEB cable 42 Jumper position settings 41 Overview 39 PEB cable 39 PEB terminator 44 Norstar Applications Module Il NAM II 156 Index Removing 46 Removing Fax from the System 48 Upgrading 46 Digital Voice Card DVC 8 53 56 58 60 141 Adding after fax is installed 62 Connecting to distribution block 55 Dip switch settings 53 Increasing Voice Channels 51 Installing the first DVC 56 Installing the fourth DVC 52 Installing the second DVC 52 Installing the third DVC 52 N ot functioning 141 Ports and channels 51 Removing the first 58 Removing the fourth DVC 60 Removing the second 58 Removing the third 58 Types of DVCs 51 Dip switch settings DVCs 53 Dip switches SBC 104 Distribution block 55 Connecti
15. Channels Hard disk drive The NAM II comes equipped with an IDE 3 5 inch hard disk with a minimum capacity of 1 2 GB The hard disk drive stores all software messages greetings and voice prompts Note To ensure your system programming is protected against a hardware failure you must perform frequent backups of the hard disk drive For more information about backing up your hard disk refer to Backing up the NAM II capabilities file on page 67 Floppy disk drive The floppy disk drive on the NAM II is a 3 5 in 1 44 MB drive This drive is used to load programs and prompts from floppy disks onto the hard disk It is also used for backup and restore procedures Power supply The power supply converts AC line voltage to DC It provides 5V DC and 12V DC to the SBC and disk drives The power supply is shipped with the default setting of 115 volts but this setting can be changed to 230 volts For more information about changing the default voltage setting refer to Changing the power supply voltage on page 98 Note The NAM II is not equipped with an ON OFF power switch This module is designed for continual use therefore we recommend that you do not use a switched power outlet Norstar Applications Module Il NAM Il Installation and Maintenance Manual Components of the NAM II 9 Ports External devices such as a laptop computer are attached to the NAM II through its ports The ports are located on the bottom of the NAM
16. II and are accessed through the cable trough Figure 3 shows the location of the different ports Figure 3 Module external points of connection Expansion card slots Serial ports Parallel port Station ports Keyboard Mouse Internal modem Serial The NAM Ilis equipped with two serial ports that support asynchronous RS 232C communication Each port features a male DB 9 connector and supports all standard baud rates 9600 default The serial ports are used to connect e an RS 232 terminal e laptop computer e amodem Figure 4 details the serial port pin configuration Figure 4 Serial port pin out diagram and table Pin Number Signal Name 1 DCD Data Carrier Detected RX Receive data TX Transmit data DTR Data Terminal Ready GND Signal Ground DSR Data Set Ready RTS Request to Send CTS Clear to Send RI Ring Indicator 1to5 6 to 9 O ON oa un WN Installation and Maintenance M anual Norstar Applications Module Il NAM II 10 Components of the NAM II Parallel The NAM Il is equipped with one parallel printer port that features a female DB 25 connector This port is used to connect to an optional parallel printer or CD ROM drive for software upgrades Figure 5 shows the parallel pin configuration Figure 5 Parallel port pin out diagram and table Pin Parallel p
17. Il 135 Regulatory information vii Remote access 110 Removing an application 119 Removing Fax 48 Repair equipment 28 Repair facilities vii viii Requirements Electrical 16 Environment 16 Package 15 Requirements Special parts 17 Restoring 71 121 Capabilities file 71 121 Returning the NAM II 147 RFI filter 55 RS 232 Pin designations 109 RS 232 connection pin out 109 RS 232 terminal 108 Connecting 108 S Scheduled reboot 136 Secondary hard disk drive 72 Serial number viewing 133 Serial port 9 Pin configuration 9 Server admin 113 Server Administration software 116 Server diagnostics 124 Setting the DTMF 128 Sharing 130 Sharing Channels 130 Shutting down NAM Il Graceful 29 Immediate 29 Quick 29 Installation and Maintenance Manual Shutting down the NAM 121 Shutting down the NAM Il 134 SIMMs 7 79 Removing 83 single 53 Single Board Computer SBC 7 Dip switch settings 104 Installing 103 Overview 101 Removing 102 Replacing 102 Software 12 ACCESS 12 hierarchy 12 System 12 Stand NAM II 20 Starting the NAM II 24 Station Ports 15 SVGA video card 87 SVGA video card on the SBC 89 Symbols 2 System Software 12 T Time Compression M ultiplexing TCM 5 Tools for repairs 28 Troubleshooting Voice Channels 142 145 Diagnosing problems 140 Digital Voice Card DVC Voice card Troubleshooting 141 Hardware 140 Trough cable 32 U Upgrades DFC 46 DFC expansion card 47 M emory 79 uses for 9
18. Media Services Base Interface Card MSBIC you will need to refer to the Media Services Base Interface Card Documentation Supplement This guide provides instructions on installing a Norstar station port if there are no free station ports available at the distribution block Installation overview Installing a NAM II involves the following power supply switch setting if required mounting the unit on the wall connecting the station port s connecting the power cord Installation and Maintenance M anual Norstar Applications Module Il NAM II 18 Installing the NAM II Changing the power supply voltage The power supply on the NAM II is set at the factory to operate at 115 volts If you plan to use 115 volts to power the NAM II do not change the voltage switch If you plan to use 230 volts to power the NAM II you must change the power supply voltage setting before mounting the unit on the wall Refer to Changing the power supply voltage on page 98 Mounting on the wall Caution A The NAM II contains fragile electronic components Do not drop or bump the module The NAM II weighs 13 6 kg 30 Ibs You must fasten the back of the module to the backboard to fully support the weight of the NAM II 1 Install the 3 4 inch plywood backboard on the wall 2 Position NAM II mounting bracket on the backboard Place the smooth side flush against the backboard with the screw holes near the top Ensure the bracket is level
19. NAM II For more information refer to Shutting down the NAM II on page 29 Remove the NAM II power cord from the AC outlet Open the front cover of the NAM II Refer to Accessing the inside of the NAM II on page 30 Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface Locate slot 8 on the expansion bus Remove the slot cover screw and the metal slot cover from the slot Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing the Digital Fax Card DFC 41 Figure 18 Locating the expansion bus slots 6 Ensure there is a jumper on position 10 of J4 on the DFC Switch S1 should be set according to the following table Position 8 7 6 5 4 3 2 1 State off jon off loff jon on on on The settings in this table are the default values and should be set properly when the board is received Refer to Figure 17 on page 39 for the location of the jumper posts J4 and switch S1 7 Carefully hold the DFC along the top Insert the c
20. Printer 10 Rebooting 135 Remote access 110 Removing Fax 48 Removing the front cover 30 31 Removing the hard disk drive 68 Restoring the capabilities file 71 Secondary hard disk drive 72 Serial number 133 Serial Ports 9 Shutting down 29 134 shutting down 29 Single Board Computer SBC 7 101 102 103 Software hierachy 12 Stand 20 System software 12 Norstar Applications Module Il NAM II 158 Index Tools 28 Troubleshooting 140 Voice Channels 51 Voltage 18 97 Voltage changing 98 NAM Il serial number 133 N etwork Interface Card 11 O O perating system 12 O ptional equipment 11 Modem 11 Monitor package 11 N etwork Interface Card 11 Printer 11 OS 2 Warp 12 P Parallel port 10 Password 120 125 ACCESS Server admin 120 System 125 PCM Expansion Bus PEB cable 39 Installing 42 PEB cable 39 Installing 42 PEB terminator 44 Pin configuration 10 Pin connector 10 Plastic case 30 NAM II 32 Removing 32 Port sharing 130 Ports 9 Keyboard 10 M ouse 10 Parallel 10 Printer 10 Serial 9 Station 15 Ports Voice 51 Power requirement 16 Power supply 8 98 Changing 18 Changing voltage 98 Specification 97 Power maximum 16 Powering up 24 Printer 10 127 Changing options 127 Norstar Applications Module Il NAM II Printer connection 10 Printing 110 116 Changing printer options 116 Connecting a printer 110 Processor 7 R Rebooting NAM Il 122 Rebooting the NAM NAM Il Rebooting 122 Rebooting the NAM
21. and upgrading the Digital Voice Cards DVC s Figure 36 Removing the DVC 8 Replace the front cover 9 Plug the power cord into the AC outlet Removing the first DVC This procedure is only for removing the first DVC from the NAM II The first DVC will be found in slot 2 If you are removing any other DVCs refer to Removing the second third or fourth DVC on page 58 A DVC is removed when a failure is suspected or confirmed Note If your system has Norstar Voice Mail installed ensure the TCM loop connected to the DVC is not associated with the Norstar Voice Mail DN If the TCM loop is associated with the Norstar Voice Mail DN make sure you reconnect the loop back to another DVC To remove the first DVC 1 Shutdown the NAM II For more information refer to Shutting down the NAM II on page 29 2 Remove the NAM II power cord from the AC outlet 3 Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing and upgrading the Digital Voice Cards DVC s 61 4 Remove the front cover Refer to Removing the plastic case on page 32 earlier in this section for more information on accessing the module 5 Disconnect the Serial Port A and Serial Port B connectors from the SBC Disconnect the keyboard mouse connector
22. anual Norstar Applications Module Il NAM II viii Regulatory information Repair facilities In the event of equipment malfunction all repairs will be performed by Northern Telecom or by one of its authorized dealers In the USA In Canada Northern Telecom Inc N orthern Telecom Canada Ltd Nashville Repair and Distribution Center 30 Norelco Drive 640 Massman Drive W eston ON Nashville TN 37210 M9L2X6 Attn RA Tel 416 744 5201 Tel 615 883 9220 Fax 416 744 5227 Note You receive an RA when you call the repair center in Nashville This number should appear on the package of any and all parts sent to this location for repair Norstar Applications Module II NAM Il Installation and Maintenance Manual How to use this manual 1 Introduction The Norstar Applications Module II NAM II Installation and Maintenance Manual provides technical information and procedures required by a technician to install the NAM II and perform various replacement and upgrade tasks This manual is useful during and after an initial installation To use this manual you should be e an experienced Norstar installer e familiar with basic Norstar terminology How this manual is organized The NAM II Maintenance Manual is organized in five sections that cover NAM II Components This section provides an overview and functional description of NAM II hardware a description of the hardware components and shows where the co
23. bJ z E J JIJJRETRY_ ACCESS2 ACCESS Server 3 Press ADMIN BACK J NEXT f ADMIH Prtfqueuejmgr 4 Press SHOW T NEXT SHOW a The display shows the Printer Option Menu 1 Queue status 5 Press NEXT until you reach the printer option you QUI T S HESTI SHOW want 6 Follow the instructions on the display Installation and Maintenance Manual Norstar Applications Module II NAM II 128 Using the ACCESS Server administration software from a telephone set Setting the DTMF digit duration length Talk Off occurs when an application interprets certain voice patterns as tone dialing signals Tone dialing signals are produced when keys are pressed on a touch tone telephone When you press a key on the dialpad the application receives a touch tone signal and performs the correct operation associated with that key For example after you enter a password you can press the key The tone dialing signal sent indicates you are finished entering your password Some voice patterns are the same as the touch tone signal and this may cause an application to function incorrectly For example if in the middle of a message you said something that sounded the same as the touch tone signal created by pressing the t key the recording session would end Correcting Talk Off requires adjustments to the DTMF digit duration length The DTMF digit duration length can be
24. from the SBC Refer to Figure 34 on page 57 6 Locate the DVC in slot 2 and disconnect the teladapt cord Note If you are removing a two board DVC you must also disconnect the RFI filter s 7 Remove the slot cover screw Refer to Figure 35 on page 59 8 Use both hands to carefully hold the DVC along the top Lift the DVC straight up and out from the module Sometimes the DVC is tightly seated and hard to remove You may need to wiggle it out with a slight rocking motion 9 Reconnect the Serial Port A and Serial Port B connectors to the SBC Reconnect the keyboard mouse connector to the SBC Refer to Figure 34 on page 57 for the location of the connectors Note Ensure the keyboard mouse ribbon cable is still connected to the backplane 10 Replace the front cover 11 Plug the power cord into the AC outlet Installation and Maintenance M anual Norstar Applications Module Il NAM II 62 Installing and upgrading the Digital Voice Cards DVC s Adding a DVC after a DFC is installed These steps are only for systems that have Norstar Voice Mail and Norstar Voice Mail FAX installed The installation of a DVC after a DFC is installed requires a few extra steps These extra steps are required to remove PEB terminators and install the PEB cable WARNING The microprocessor heat sink may be hot Pay careful attention not to touch the heat sink while installing the PEB cable To install a DVC 1 10 Shutdown th
25. on the SBC can cause severe damage to the SBC components 16 Using a small screwdriver you must set dip switch 8 on the SBC to off in order to activate the video card Refer to Table 7 for the SBC dip switch settings Table 7 Setting the SBC dip switches for SVGA activation Position 1 2 3 4 5 6 7 8 9 State off off off on on on on off off 17 To set a dip switch to off the switch must be up and point away from the SBC To set a dip switch to on the switch must be down towards the SBC 18 Insert the SBC back into the NAM II Refer to Removing and replacing the SBC on page 102 19 Replace the front cover To connect the monitor keyboard and mouse to the NAM II 20 Plug the monitor keyboard and mouse cables into the appropriate ports Refer to Figure 50 for the location of each port The monitor will plug into the bottom of slot 4 SBC Figure 50 Bottom view external points of connection for SBC mounted video card O O Keyboard M ouse SVGA connector 21 Plug the power cord into the AC outlet Norstar Applications Module II NAM Il Installation and Maintenance Manual Adding and removing a monitor keyboard and mouse 93 Enabling the monitor keyboard and mouse After you have added the monitor keyboard and mouse you must enable it This is necessary for the NAM II software t
26. power cord from the AC outlet Unplug the station Channel s from the DVC s on the module and disconnect any other cabling or wiring to the module Remove the two screws in the cable trough Grasp the module on its sides and gently lift straight up until the module is clear of the wall mounting bracket If you are returning the NAM II for service pack it in its original shipping container If the container is not available package the module well with plenty of shock absorbing insulating material Installation and Maintenance M anual Norstar Applications Module Il NAM II 148 Troubleshooting Norstar Applications Module II NAM Il Installation and Maintenance Manual Glossary AMIS Audio Messaging Interchange Specification AMIS provides voice messaging to different mailboxes located at different sites on a communication network Application A computer program that performs a wide range of tasks as specified by the user Examples of application programs include word processing packages spreadsheet packages and accounting packages Backplane The backplane hosts the SBC and all other cards inserted in the NAM II The backplane connects the wiring between all circuits Back up To make a duplicate copy of data files so that you can store the originals in a safe place Backing up your original files protects them from damage if a hardware failure occurs Baud rate A unit of measurement of data transmission speed
27. recommends and supports any EPSON compatible printer Network Interface Card A Network Interface Card can be installed in either a PCI or ISA expansion slot depending on the configuration of your system The Network Interface Card allows your NAM II to be connected to a network Note For systems with ACD installed Before you install ACD wallboard you must install a Serial Port Network Interface Card The Serial Port Network Interface Card must be installed in an empty ISA expansion slot on the NAM Il Slots 2 5 6 7 and 8 are ISA expansions slots The Network Interface Card must be configured to specific settings The IRQ setting must be set to 2 9 or 2 9 The I O address must be set to COM 3 Ox3E8 Installation and Maintenance M anual Norstar Applications Module Il NAM II 12 Components of the NAM Il About the System software The NAM II comes equipped with system software that allows other Nortel approved applications to operate In effect the applications run on top of this software Figure 7 shows the hierarchy of the applications and system software System software includes the e ACCESS Server Software e IBM OS 2 Warp Operating system Figure 7 Software hierarchy Nortel Approved Applications ACCESS Server Software IBM OS 2 Warp Operating System ACCESS is designed to communicate with the Norstar system and provide support for voice fax and other applications running on the NAM II This sof
28. server software from the NAM II monitor 1 Open the minimized window viewer 2 Choose and open the SPMSRV window 3 Press Return Connecting a printer to the NAM II Connecting and using a printer to print reports is optional The NAM II supports any EPSON compatible printer This printer is attached to the module s parallel port Refer to Figure 55 on page 109 for the location of this port Remote access You can also perform NAM II System administration from a remote location such as your office To perform administration from a remote location both the NAM II and the remote PC must have a modem installed The NAM II modem must be connected to Serial Port A COM 1 Figure 56 Remote terminal access to NAM Il RS 232 cable connects NAM II to the modem Public N DOE Ni Modem A RS 232 cable connects the PC and the modem or PC has an internal modem LEED lt Modem B 2 RS 232 terminal or PC running Norstar Applications Module Il NAM Il Installation and Maintenance Manual Preparing to use the ACCESS Server administration software 111 Figure 56 shows how the different components are connected to allow remote terminal access to NAM II Note The modems must be set to Auto Answer in order for remote access to function Refer to the manuals that came with your modem and PC communication software documentation for more informat
29. supply wiring and ribbon cable from the floppy disk drive CAUTION Only pull or push on the plastic connectors Do not pull on the cable If the connector is tight wiggle it loose with a slight rocking motion Installation and Maintenance M anual Norstar Applications Module Il NAM II 66 Installing a new floppy disk drive Figure 37 Removing the floppy disk drive To install a new floppy disk drive 1 23 Connect the power supply wiring and ribbon cable to the floppy disk drive Slide the floppy disk drive with its two screws still attached into the two mounting slots in the module wall Fasten the screws Replace the front cover and plastic case Plug the power cord into the AC outlet Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing and upgrading the hard disk o drive Overview The NAM II includes one factory installed hard disk drive This hard disk drive can be replaced if a problem is diagnosed When you replace a hard disk you must backup and restore the NAM I capabilities file Table 4 Hard disk drive summary Hard Disk Drive Hard disk size Hours of message storage minimum minimum Primary 1 2 GB 70 Secondary 1 2 GB 77 A pproximate the amount of message storage time depends on what applications are installed on the NAM Il hard disk drive Backing up the NAM II capabilities file You m
30. system Three shutdown options are available Graceful Quick and Immediate The Graceful option allows an application to terminate all existing calls before shutting down The Quick option only allows 45 seconds for an application to terminate before shutdown and the Immediate option only allows 15 seconds When you are shutting down the NAM II you will usually use the Graceful option However if the system is not responding to the command you can speed up the process by changing the option to a Quick shutdown After 45 seconds a Quick shutdown is performed To shutdown the NAM II 1 Press Feature fo i jis J 2 Enter the ACCESS password Note The default password is ACCESS2 2223772 ACCESS Server 3 Press NEXT BACKI NEXT ADMIN J ystemf shutdown 4 Press SHO ACK NEXT SADON A Shutdownftype 5 Press GRACE QUI Tf NEXT GRACE Note Press NEXT to change the shutdown option to QUI CK Quick or MMD immediate 6 Press YES Note Press NO if you want to stop the shutdown The NAM II issues a series of tones descending in pitch when the shutdown is complete Wait for the tones before you unplug the NAM II Installation and Maintenance M anual Norstar Applications Module Il NAM II 30 Preparing for the upgrade Accessing the inside of the NAM Il You must unplug the NAM II before you install or remove any components The NAM
31. system has Norstar Voice Mail installed ensure the TCM loop connected to the DVC is not associated with the Norstar Voice Mail DN If the TCM loopis associated with the Norstar Voice Mail DN make sure you reconnect the loop back to another DVC To remove a DVC 1 2 Shutdown the NAM II For more information refer to Shutting down the NAM II on page 29 Remove the NAM II power cord from the AC outlet Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing and upgrading the Digital Voice Cards DVC s 59 3 Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface 4 Remove the front cover Refer to Removing the front cover on page 31 for more information on accessing the module 5 Locate the DVC and disconnect the teladapt cord Note If you are removing a two board DVC you must also disconnect the RFI filter s 6 Remove the slot cover screw Figure 35 Removing the slot cover screw yg 7 Use both hands to carefully hold the DVC along the top Lift the DVC straight up and out from the module Note Sometimes the DVC is tightly seated and hard to remove You may need to wiggle it out with a slight rocking motion Installation and Maintenance Manual Norstar Applications Module Il NAM II 60 Installing
32. the DFC in slot 8 Remove the slot cover screw Refer to Figure 35 on page 59 Disconnect the PEB Cable from the DFC Carefully hold the DFC with both hands along the top Lift the DFC straight up and out from the module Sometimes the DFC is tightly seated and hard to remove You may need to wiggle it out with a slight rocking motion Remove the DVCs and re install both PEB terminators XRN1 and XRN2 on all the DVCs Refer to Figure 23 on page 44 or Figure 24 on page 44 for the location of the terminators Re install the DVCs in the appropriate slots Insert the FXDSABLE diskette into the floppy disk drive Plug the power cord into the AC outlet and wait for the NAM II to boot from the disk This should take two or three minutes Once all disk activity has ceased and the light on the floppy disk drive has gone out unplug the NAM II and remove the FXDSABLE diskette from the floppy disk drive Close the module door To lock the door turn the lock 90 clockwise until the screwdriver slot is horizontal Plug the power cord into the AC outlet Installation and Maintenance M anual Norstar Applications Module Il NAM II 50 Installing the Digital Fax Card DFC Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing and upgrading the J Digital Voice Cards DVC s Overview The NAM Ilis factory equipped with at least one Digital Voice Card DVC Up to four DVC s can be installed in the module
33. 115 To access the Alarm and Message Log 1 Press to select Alarm and Message Log and then press Reurn The screen shows the Application Administration Menu Alarm and Message Log 1 View Log 2 Clear Log Q Quit Enter Selection Number 2 Press the number of the function you want 3 Press Q and then press Reurn to return to the ACCESS Server Administration Menu Allocating Voice and Fax Channels If you are upgrading the number of Voice Channels you can use the ACCESS Server to allocate the new Channels You can allocate Channels by giving voice mail sole ownership of a Channel or you can assign the Channel to a pool where it is shared Before you can access the Voice and Fax Channel Allocation option the ACCESS Server Administration Menu must appear on your monitor For more information about accessing the Server Administration software refer to Administering an application on page 115 Installation and Maintenance M anual Norstar Applications Module Il NAM II 118 Using the ACCESS Server administration software from a terminal To access the Voice and Fax Channel Allocation menu 1 Press to select Voice and Fax Channel Allocation option and then press Reurn The screen shows the Voice and Fax Channel Allocation Menu Voice and Fax Channel Allocation 1 View Current Channel Allocation 2 Allocate Channels to Applications 3 Default Channel Allocation Q Quit Enter Selection Number
34. 30 40 50 or 60 milliseconds ms The default is 40 ms If the DTMF digit duration length is to low the application may mistake speech for DTMF tones If the DTMF digit duration length is too high the application may fail to recognize the touch tone signals If you are changing the DTMF digit duration on a NAM II that has DVCs installed you must reboot the system in order for the changes to take effect To change the DTMF digit duration length 1 Press Feature 9 1 5 Password 2 Enter the default password 2 2 _ 2_ 3 7 J 7 l2 JISIIITIIIIRETRY ACCESS2 ACCESS Server 3 Press NEXT until the display shows BACKI NEXT AGMIN DTMF Delay 4 Press SHOW a BACKI NEXT SHOU A DIMF delay xxms 5 Press CHG to change the DTMF digit duration QUIT eaj OK J length xx will be the DTMF digit duration length DTMF delay 6 Enter the new DTMF digit duration length and press QUIT RETRY OK J OK 30 40 50 or 60 ms are the only acceptable DTMF digit duration length values DTMF delay XXms 7 Press OK to accept the DTMF digit duration length oul T CHG OK Norstar Applications Module Il NAM Il Installation and Maintenance Manual Using the ACCESS Server administration software from a telephone set 129 l Reboot needed 8 Systems with DVCs installed must be rebooted in order for the changes i
35. 5 on the other end The end of the cable attached to the NAM II must be female Norstar Applications Module Il NAM Il Installation and Maintenance Manual Preparing to use the ACCESS Server administration software 109 Figure 54 Pin out diagram Table 12 Pin definition NAM II Pin RS 232 terminal Transmit data 2 Receive data Receive data 3 Transmit data Ground 5 Ground 2 Attach the RS 232 cable to the NAM II Serial Port A COM1 Refer to Figure 55 for the location of Serial Port A COM1 Figure 55 Module external points of connection Expansion card slots Serial ports Internal modem AC power Parallel H plug port Keyboard Mouse MSBIC Internal Modem SBC 3 Attach the other end of the cable to the modem connector on the terminal You must use a null modem cable The parameters must be set to match the NAM II default parameters Installation and Maintenance M anual Norstar Applications Module Il NAM II 110 Preparing to use the ACCESS Server administration software Using the Server administration software from the NAM II monitor If you have an optional monitor attached to the NAM II there is no need to attach an external RS 232 terminal or laptop computer You can access the server software by opening the OS 2 Warp Connect window SPMSRV To access the
36. Applications Module II NAM Il Installation and Maintenance Manual Section V Troubleshooting e Troubleshooting Installation and Maintenance M anual Norstar Applications Module II NAM Il 138 Troubleshooting Norstar Applications Module II NAM Il Installation and Maintenance Manual Troubleshooting 18 Overview Troubleshooting NAM II problems involves determining the symptoms and diagnosing the cause of the problem A problem can be the result of more than one component failure Diagnosing a NAM II problem involves isolating the cause and determining whether or not the malfunction involves a failed hardware component After you have determined the cause of the problem and corrected the problem by replacing a component you must test the NAM II to determine whether or not it is working properly Installation and Maintenance M anual Norstar Applications Module Il NAM II 140 Troubleshooting Diagnosing problems A malfunctioning NAM II can be caused by a faulty component This section describes the symptoms that occur when the NAM II malfunctions The section describes symptoms particular to hardware The symptoms are described first followed by procedures to confirm and correct the problem CAUTION A Before attempting any repair procedures that require replacing internal components attach one end of your grounding strap to your wrist and the other end to the NAM Il Hardware problems Hardware problems appe
37. Each DVC supports two station ports each with two Voice Channels Figure 29 DVC ports and channels Digital Voice Card First TCM channel First port lt Second TCM channel Third TCM channel Second port lt Fourth TCM channel Increasing the number of Voice Channels On each DVC card the first two Voice Channels are factory enabled the second two Voice Channels are spares and are enabled using an upgrade software Security Key Code How you implement the upgrade depends on how many Voice Channels you are adding and how many are already enabled Upgrades are either done by adding a new DVC or by using an upgrade software Security Key Code Types of DVCs There are two types of DVCs available for the NAM II a two board DVC and a single board DVC Both DVCs function exactly the same and can be readily interchanged The difference between the single board and the two board DVC is the single board incorporates the functionality of both boards and the RFI filter onto a single board Refer to the figure Two board Digital Voice Card on page 52 and the figure single board Digital Voice Card on page 53 Installation and Maintenance Manual Norstar Applications Module II NAM II 52 Installing and upgrading the Digital Voice Cards DVC s Installing the second third or fourth DVC This procedure is for installing the second third or fourth DVC on the NAM II These DVCs will be placed in slots 5 6 and 7 respectively If you ar
38. ID as the device type If any Channel numbers connected to Norstar Voice Mail show NONE as the device type it indicates the DVC is not working Note You can also use an M7324 set to display the working Norstar Voice Mail Channels After you have identified which Channels are not appearing in the Channel DN Status display trace the teladapt cords from the teladapt jacks to the Applications Module This shows you which DVC is not working If any DVCs are identified as not working 12 Verify the DVC Switch and Jumper settings Refer to Installing the second third or fourth DVC on page 52 13 Replace the DVCs and retest the DVC Channels Refer to Installing and upgrading the Digital Voice Cards DVC s on page 51 14 If the NAM II is attached to a Centrex KSU make sure all Channels are defined as Norstar only Checking the Channel Status Checking the Channel Status allows you to check each Channel for the following e If the Channel is installed e If the Channel is idle e If the Channel is currently receiving or dialing a call e If the Channel is connected to a call e If the Channel is connected to the KSU but no application using the Channel e Ifthe Channel is available but has been not connected to the KSU e Disable or re enable a Channel Note Channel Status will show the status for all Channels Channel Status will not identify the Channels as Voice or Fax Fax Channels are only available on systems with N orstar Voice Mai
39. II components are accessed by removing the front cover or plastic case Access to external connections is made through the cable trough Figure 13 shows the different access points on the module Figure 13 Parts involved while accessing the inside of the module a Front cover Plastic case CT Ii MA iy ny i HA ny Cable trough door The front cover must be removed when you need to access all internal components You must remove both the front cover and plastic case when you need to replace the floppy disk drive WARNING The plastic door is part of the fire enclosure system This door is required to meet safety requirements It must be closed upon completion of each installation or repair Norstar Applications Module Il NAM Il Installation and Maintenance Manual Preparing for the upgrade 31 Removing the front cover For most component upgrades or replacements you must remove the front cover The front cover protects the components from dust and assists in evenly distributing air flow from the fan To remove the front cover 1 Shutdown the NAM II Note For more information refer to Shutting down the NAM II on page 29 2 Remove the NAM II power cord from the AC outlet 3 Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal su
40. M II power cord from the AC outlet Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface Remove module front cover Refer to Accessing the inside of the NAM II on page 30 Disconnect the Serial Port A and Serial Port B connectors from the SBC Disconnect the keyboard mouse connector from the SBC Refer to Figure 34 on page 57 Disconnect the reset and speaker two brown connectors from the side of the SBC Disconnect the three ribbon cable connectors near the top of the SBC Refer to Figure 43 on page 80 WARNING The microprocessor heat sink may be hot Pay careful attention not to touch the heat sink while removing or installing the SBC Remove the SBC slot cover screw Use both hands to carefully hold the SBC along the top Lift the SBC straight up and out from the module Sometimes the SBC is tightly seated and hard to remove You may need to wiggle it out with a slight rocking motion Place the SBC on a flat surface with the SIMM slot facing up Refer to the figure Removing the SIMM on page 84 Installation and Maintenance M anual Norstar Applications Module Il NAM II 84 Adding and replacing memory Caution A Failure to place the SBC on a flat surface may result in serious damage to the SBC W hile the SBC is out of the NAM Il be careful not to slide or catch the back of the SBC this may cause the modules on the back of the SBC to become d
41. Norstar Applications Module II Installation and Maintenance Manual Norstar is a trademark of Northern Telecom Copyright Northern Telecom 1997 1 800 4 NORTEL www nortel com norstar Norstar is a trademark of Northern Telecom P0869547 Issue 02 Printed in Canada Contents Chapter 1 Regulatory information vii Repair facilities viii Introduction 1 How this manual is organized 1 How to use this manual 1 Knowing the symbols 2 NAM Il Components 3 Chapter 2 Components of the NAM II 5 NAM II upgrades 6 Hardware components of the NAM II 6 Single Board Computer SBC 7 Digital Voice Cards DVC 8 Hard disk drive 8 Floppy disk drive 8 Power supply 8 Ports 9 Optional equipment 11 About the System software 12 Installing the NAM Il 13 Chapter 3 Installing the NAM Il 15 Introduction 15 Station ports versus Voice Channels 15 Before you start 15 Packaging Checklist 15 Environment Checklist 16 Electrical Checklist 16 Special parts and equipment 17 Other documentation 17 Installation overview 17 Changing the power supply voltage 18 Installation and Maintenance M anual Norstar Applications Module Il NAM II Mounting on the wall 18 Floor mount stand 20 Assembling the floor mount stand 20 Attaching the floor mount stand to the NAM H 20 Installing the end caps 22 Connecting to the KSU 22 Connecting the internal modem 24 Powering up the NAM II 24 NAM Il Hardware Upgrades and Replacements 25 Chapter
42. T DETAIL 1 2225 ee 7 QUIT HEST DSBL 3i 2221 N 8 3 Not in sync 9 Press Enter the default password ACCESS2 Press NEXT until the display shows Press SHOW Press SHO gt Press DETAIL Press NEXT until the Channel you want to disable is displayed Press DSBL Press R s to end this programming session Norstar Applications Module Il NAM II 146 Troubleshooting To re enable the Channel 1 Press Password 2 Enter the default password LITITITITIPRETRY ACCESS2 ACCESS Server 3 Press NEXT until the display shows BACK NEXT ADMIN Channel Status 4 Press SHOW BACK NEXT SHOW Chan Status Menu 5 Press SHOW QUITS ALL SHOW J 01 08 gt cc crr 6 Press DETAIL QUIT NEXT DETAIL i 2225 xx 7 Press NEXT until the Channel you want to re enable QUI HERT DSBL is displayed 3 Not in sync 8 Press ENBL QUIT NEXT ENEL J 3 2221 FFE 9 Press R QUIT NEXT DSBL s to end this programming session Norstar Applications Module II NAM Il Installation and Maintenance Manual Troubleshooting 147 Preparing the NAM II for travel Perform the following if you are returning the NAM II to the factory for service or are mounting it in a new location 1 Shutdown the NAM II For more information refer to Shutting down the NAM II on page 29 Remove the NAM II
43. To assemble the floor mount stand 1 Align the two halves of the floor mount stand back to back 2 Using the four screws provided fasten the two sides together Refer to Figure 11 for an illustration of an assembled floor mount stand You must use all four screws Attaching the floor mount stand to the NAM II To fasten the floor mount stand to the NAM II 1 Rest the module on a tabletop with the door facing down The cable trough should hang over the edge of the table If a table is not available rest the module on the floor mount stand carton 2 Remove the top screws at the back of the module Leave the washers in place You will need them if you want to place the module on the wall again 3 Rest the floor mount stand on top of the module aligning the stand into the groove on the back of the module The longer of the two feet on the stand must be pointing down towards the front of the module 4 Align the four screw holes between the module and the stand 5 Fasten the screws into the module Norstar Applications Module II NAM II Installation and Maintenance Manual Installing the NAM II 21 Caution Only use the screws that came with the floor mount stand or are on the back of the unit Do not substitute screws Substitute screws can damage the module Figure 11 Fastening the floor mount stand to the module 6 Put the module in the location you want 7 Reconnect the cables Note You can run t
44. V Video card Enabling 93 Installed on SBC 89 Installing 87 89 Voice card Connecting 55 Installing 56 Removing 58 Voice Cards 8 Installation and Maintenance Manual Index 159 Voice cards 51 Voice Channel sharing 130 Voice Channels 15 51 117 Allocating 117 130 Increasing number 51 Re enabling 146 Voice Channels B1 and B2 5 Voltage of the NAM Il 18 Voltage Nominal 16 Range 16 Selected 16 Voltage changing 98 WwW W arning symbol 2 Norstar Applications Module II NAM II 160 Index Norstar Applications Module II NAM Il Installation and Maintenance Manual
45. amaged 10 Each SIMM is connected to the SBC by two metal clips on each side of the SIMM s edge connector Gently push each clip away from the SIMM until it unlatches from the SIMM The SIMM should fall back slightly when released 11 Pull the SIMM back from its connector 12 Remove the SIMM from the slot Figure 45 Removing the SIMM 13 Carefully hold the SBC along the top Insert the card by aligning it between the metal groove on one side and the slot opening on the other side 14 Push the SBC straight down until it fits snugly in place Ensure the edge connector is firmly inserted into the backplane socket refer to Figure 53 on page 103 Norstar Applications Module Il NAM Il Installation and Maintenance Manual Adding and replacing memory 85 15 Reconnect the Serial Port A and Serial Port B connectors to the SBC Reconnect the keyboard mouse connector to the SBC Refer to Figure 43 on page 80 for the location of the connectors Note Ensure the keyboard mouse ribbon cable is still connected to the backplane 16 Reconnect the reset and speaker two brown connectors to the side of the SBC Reconnect the three ribbon cable connectors to the top of the SBC Refer to Figure 43 on page 80 for the proper alignment of the connectors 17 Fasten the slot cover screw 18 Replace the front cover 19 Plug the power cord into the AC outlet Installation and Maintenance M anual Norstar Applications Module Il NAM II
46. application The Application Administration menu allows you to administer the NAM II system or the ACCESS Server If other applications are installed on the NAM II they can also be administered from this menu For information on accessing and using the NAM II Administration software refer to Using the Server administration software from the NAM II monitor on page 110 To access the ACCESS Server menu 1 Press for Application Administration then press Reurn The screen shows the Application Administration Menu Application Administration Menu 1 ACCESS Server 2 NAM II Q Quit Enter Selection Number 2 Press and then press Reurn 3 Enter the ACCESS password then press Reurn Note The default password is 2223772 ACCESS2 The screen shows the Application Administration Menu ACCESS Server Administration Print Queue Manager Alarm and Message Log Voice and Fax Channel Allocation Application Installation De Installation Server Password Control Backup Restore Q Quit Enter Selection Number Installation and Maintenance M anual Norstar Applications Module Il NAM II 116 Using the ACCESS Server administration software from a terminal Changing the printer options The Print Queue Manager allows the control of print requests to an optional printer and provides the following options hold or cancel a print request resume printing clearing the queue alter the print priority Before yo
47. ar Applications Module Il NAM II 70 Installing and upgrading the hard disk drive Figure 39 Removing the hard disk drive from bracket CAUTION Shock can damage the hard disk Do not drop or bump the hard disk drive If you are returning the disk drive to a Nortel repair facility package it carefully in the box that the replacement disk drive came in If you do not have the original box package the drive in another box with plenty of shock absorbing material Installing a new hard disk drive Before you can install a new hard disk drive you must remove the hard disk drive bracket from the NAM II When you are replacing the hard disk drive you must also remove the existing hard disk from the disk drive bracket To install a new hard disk drive 1 Fasten the hard disk drive to the bracket The hard drive must be positioned with the bottom of the hard disk drive the side with the exposed electronic connectors facing down and into the module Refer to Figure 2 on page 7 for the location of the hard disk drive 2 Insert the tongues on the bracket into the holes in the module wall 3 Press the bracket firmly against the module wall so each of the nylon fasteners partly goes through the holes in the module wall 4 Press each nylon fastener through the hole in the module wall until the fastener snaps shut Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing and upgrading the hard disk driv
48. ar as any of the following e NAM II does not function at all e The Power on diagnostics fail e The Power on diagnostics run but the download diagnostics do not e NAM II Digital Voice Cards DVCs are not functioning properly Note The procedures describe the components in the order of the most likely to cause the trouble The NAM II does not function at all If there is no response from the NAM II or the Feature Codes do not appear on the Norstar display 1 Make sure the e AC power cord is plugged in e NAM Ilis getting power from the AC outlet Note When the power is connected the fan works 2 Unplug the NAM II and remove the front cover Reseat the DVC s Check to ensure all ribbon cable and power supply connectors are properly connected 3 Reseat the SBC located in slot 4 Check to ensure all ribbon cables are connected to the SBC 4 Replace the front cover and plug in the NAM II Norstar Applications Module Il NAM Il Installation and Maintenance Manual Troubleshooting 141 Digital Voice Cards are not functioning properly 1 Check the setting of Auto Set Relocation on the Norstar System Set it to Off Refer to the Norstar Installation Guide for instructions 2 Unplug the NAM I and open the module door Remove the two screws holding the front cover to the module The screws are located along the top of the front cover Slide the front cover out from the module 3 Ensure that each card is securely seated in it
49. ard by aligning it between the metal groove on one end and the slot opening on the other end 8 Push the DFC straight in until it is snugly in place Ensure the edge connector is firmly inserted into the backplane socket Installation and Maintenance M anual Norstar Applications Module Il NAM II 42 Installing the Digital Fax Card DFC Figure 19 Inserting the DFC 9 Fasten the slot cover screw in the DFC slot cover Note If there is a DVC in slot 7 you must connect the PEB cable to the DFC before installation 10 Proceed to step 1 of Connecting the DFC to the DVCs with the PEB Cable Connecting the DFC to the DVCs with the PEB Cable Figure 20 and Figure 21 show examples of how the PEB cable is installed In the examples the module is equipped with four DVCs The DFC is at the right end of the PEB chain in slot 8 and the leftmost DVC DVC 1 is at the other end of the chain in slot 2 Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing the Digital Fax Card DFC 43 Figure 20 PEB Cable installation example with two board DVCs WARNING The microprocessor heat sink may be hot Pay careful attention not to touch the heat sink while installing the PEB cable To connect the DFC to the DVCs with the PEB cable 1 Remove all DVCs from the NAM II Refer to Removing the second third or fourt
50. ating frequency in cycles per second Initialization The steps required to prepare hardware or software for operation Install To set up for operation For example hardware is installed by attaching it to the appropriate connectors or sockets either inside or outside the NAM II Interface An information interchange path that allows communication between computer parts Interleave The number of hard drive revolutions required to read from or write to one entire track of data For example a 3 1 interleave requires three revolutions to read from or write to an entire track of data a 1 1 interleave requires only one complete disk revolution to read from or write to an entire track of data The lower the ratio the faster the read write operation IRQ Interrupt Request A signal sent by a hardware device to the microprocessor requesting its immediate attention For example each communications port has an interrupt request line for notifying the microprocessor when data has been received or transmitted Kbyte The abbreviation for kilobyte A kilobyte is equal to 1024 bytes Mailbox A storage place for messages on the Norstar Voice Mail system Mbyte The abbreviation for megabyte A megabyte is equal to 1 048 576 bytes Megabyte is also abbreviated as MB Installation and Maintenance M anual Norstar Applications Module Il NAM II 152 Glossary MHz The abbreviation for megahertz This is a unit of measure indicatin
51. d electronic connectors facing down and into the module Use the placement of the primary hard disk drive as an example Note Refer to Figure 2 2 for the location of the two hard disk drives 3 Set the jumper position for the secondary hard disk drive Refer to the figure Setting the jumper position for the secondary hard disk drive Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing and upgrading the hard disk drive 73 Figure 40 Setting the jumper position for the secondary hard disk drive Primary hard drive Secondary hard drive Nylon fastener Primary hard drive _ a Secondary hard drive jumper position jumper position Bracket 4 Insert the tongues on the bracket into the holes in the module wall 5 Press the bracket firmly against the module wall so each of the nylon fasteners partly goes through the holes in the module wall 6 Press each nylon fastener through the hole in the module wall until the fastener snaps shut 7 Connect the ribbon cable and hard disk power supply wiring The connector at the end of the ribbon cable is used for the primary disk drive the second connector is used for the secondary hard disk drive CAUTION All connectors are keyed or shaped so they cannot be inserted backwards If you cannot push a connector in easily do not force it 8 Replace the front cover 9 Insert the AUTO CONFIGURATION DISK into the floppy disk d
52. d port 10 KSU connecting the NAM II 22 L LAN card 11 Laptop computer 108 Connecting 108 M Manual organization 1 Manual overview 1 Memory Adding 79 Expansion capabilities 7 79 Removing 83 Modem Connecting to an ATA 78 Installing 76 Internal 75 Module parts Door 30 Monitor Enabling 93 Removing 95 Monitor package Enabling 93 Installing the SVGA 87 89 Removing 95 Monitor keyboard and mouse Enabling 93 Mounting the NAM Il 18 Mouse Enabling 93 Port 10 Removing 95 N NAM Il ACCESS Server 12 Accessing interior components 30 Adding memory 79 Attaching a stand 20 Backing up the capabilities file 67 Cable trough 32 Connecting 22 Connecting a DVC 55 Connecting a printer 110 Installation and Maintenance M anual Index 157 Connection points 9 Digital Fax Card DFC slot 40 Digital Fax Card DFC removing 46 Digital Voice Card DVC 8 DVC types 51 Floppy disk drive 8 65 Hard disk drive 8 67 70 Hardware 6 Hardware components 7 Installing a DFC 40 Installing a PEB cable 42 Installing clock calendar battery 37 Installing the fourth DVC 52 Installing the second DVC 52 Installing the SVGA 87 89 Installing the third DVC 52 Interior components 7 Internal modem 75 Keyboard port 10 Memory 7 Monitor package 93 95 Mounting 18 Mouse port 10 Operating system 12 Optional equipment 11 Packing 147 Parallel Port 9 Parallel port 10 Parts 30 PEB cable 39 Plastic case NAM Il case 32 Ports 9 Power Supply 8
53. disk drive 72 Overview 75 Removing the internal modem 75 Installing a new Internal modem 75 Installing a new internal modem 76 Connecting the internal modem to an Analog Terminal Adapter ATA 78 Overview 79 Adding memory 79 Adding and replacing memory 79 Removing memory 83 Overview 87 Installing the SVGA video card 87 Adding and removing a monitor keyboard and mouse 87 Installing the SVGA video card on the SBC 89 Enabling the monitor keyboard and mouse 93 Removing the monitor keyboard and mouse 95 Overview 97 Installation and Maintenance M anual Norstar Applications Module Il NAM II iV Chapter 13 Chapter 14 Changing the power supply voltage 97 Changing the power supply voltage 98 Overview 101 Installing and replacing the Single Board Computer SBC 101 Removing and replacing the SBC 102 ACCESS Server Administration 105 Chapter 15 Chapter 16 Chapter 17 Preparing to use the ACCESS Server administration software 107 Overview 107 Using an RS 232 terminal or laptop PC 108 Using terminal emulation 108 Connecting an RS 232 terminal or laptop computer 108 Using the Server administration software from the NAM II monitor 110 Connecting a printer to the NAM II 110 Remote access 110 Using the ACCESS Server administration software from a terminal 113 Overview 113 Administering an application 115 Changing the printer options 116 Viewing the Alarm and Message Log 117 Allocating Voice and Fax Channe
54. e 71 5 Connect the hard disk power supply wiring and ribbon cable The connector at the end of the ribbon cable is used for the primary hard disk drive Note All connectors are keyed or shaped so they cannot be inserted backwards If you cannot push a connector in easily do not force it 6 Replace the front cover 7 Plug the power cord into the AC outlet Restoring the NAM II capabilities file If your system fails and a new hard disk drive is installed the new drive is installed with all the necessary system software The SEKUR file contains all upgrade and capability information about your system and must be restored if a hard disk failure occurs If this file is lost and your hard disk drive fails all upgrades made to your system will be lost When you restore the SEKUR file you must make sure you are restoring the most recent backup To restore the NAM II capabilities file 1 Beanie PET RED RT BACK NEXT ADMIN Installation and Maintenance M anual 2 Accessf Server 3 A Prt fqueue mgr 4 QUI T NEST SHOW E fBckp Rstr Vp 5 QUIT NEXTS SHOW Backup amp jRestore 6 QUIT BCKP RSTR Press Feature fo fi jis Enter the ACCESS password Note The default password is ACCESS2 2223772 Press ADMIN Press NEXT until the display shows E Bckp Rstr Press SHOW Press RSTR Insert the bac
55. e NAM II For more information refer to Shutting down the NAM II on page 29 Unplug the module from the AC outlet Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface Remove the front cover Refer to Removing the front cover on page 31 Open the module door and remove the front cover Set the switches and jumpers on the DVC you are adding Settings for the switches and jumpers are listed in Installing the second third or fourth DVC on page 52 Remove the XRN1 and XRN2 terminators from the DVC you are installing For the location of the terminators refer to Figure 23 on page 44 Disconnect the PEB cable from the DVCs already installed in the NAM II Remove the slot cover screw and the metal slot cover from the slot you are adding the new DVC to Note DVC slot assignment is listed in Table 3 on page 54 Carefully hold the DVC along the top Insert the card by aligning it between the metal groove on one side and the slot opening on the other side Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing and upgrading the Digital Voice Cards DVC s 63 11 Push the DVC straight down until it fits snugly in place Ensure the edge connector is firmly inserted into the backplane socket refer to Figure 32 on page 55 12 Fasten the slot cover screw in the DVC slot cover 13 Connect the PEB cable to each DVC in the NAM II 14 F
56. e Norstar KSU for more information 3 Shutdown the NAM II For more information refer to Shutting down the NAM II on page 29 Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing and upgrading the Digital Voice Cards DVC s 57 4 Remove the NAM II power cord from the AC outlet 5 Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface 6 Remove the front cover Refer to Removing the front cover on page 31 7 Disconnect the Serial Port A and Serial Port B connectors from the SBC Disconnect the keyboard mouse connector from the SBC Refer to Figure 34 Figure 34 Disconnecting the Serial Ports A and B and the keyboard mouse connector Keyboard mouse backplane connector Serial Port A Connector Serial Port B Connector Keyboard mouse Connector 8 Unpack the DVC from the shipping container and antistatic bag Inspect for damage Handle the board by its edges at all times Do not touch any card components 9 Set the dip switch on SW1 Refer to Table 2 on page 53 for information about the dip switch settings 10 Ensure the jumper on JP1 is on position 11 11 Position the jumper on JP7 according to the settings outlined in Table 3 on page 54 Note No changes to factory default settings are required for the remaining switches and jumpers Installation and Maintenance M anua
57. e installing the first DVC in slot 2 refer to Installing the first DVC on page 56 Before you begin to install a DVC make sure you have a teladapt cord and if necessary an upgrade password If you are installing a two board DVC you will require an RFI filter You must also make sure that you have an antistatic strap to ground yourself with Note Before you add functionality to the NAM II you must first perform a backup Refer to Backing up the NAM II capabilities file on page 67 To install a DVC 1 Ensure there is a Norstar station port available at the distribution block and wired to the KSU For more information on connecting the KSU to the NAM II refer to the Connecting to the KSU on page 22 For instructions on mounting teladapt jacks and connecting the teladapt jacks to the station ports refer to the Norstar Installation Guide 2 Ensure that Auto Set Relocation on the Norstar system is set to NO Refer to the Norstar Installation Guide that came with the Norstar KSU for more information Figure 30 Two board Digital Voice Card Installation and Maintenance M anual Norstar Applications Module Il NAM Installing and upgrading the Digital Voice Cards DVC s 53 Figure 31 single board Digital Voice Card 3 Shutdown the NAM II For more information refer to Shutting down the NAM II on page 29 4 Remove the NAM II power cord from the AC outlet 5 Ground yourself by at
58. e keyboard mouse connector from the SBC Refer to Figure 43 on page 80 Locate the internal modem card and disconnect the teladapt cord The internal modem will be located in slot 3 Remove the slot cover screw Refer to Figure 35 on page 59 Use both hands to carefully hold the internal modem card along the top Lift the card straight up and out from the module Note Sometimes the internal modem card is tightly seated and hard to remove You may need to wiggle it out with a slight rocking motion Installation and Maintenance Manual Norstar Applications Module II NAM II 76 Installing a new Internal modem Installing a new internal modem Before you begin to install the new internal modem make sure that you have an antistatic strap to ground yourself with To install the internal modem 1 Unpack the internal modem from the shipping container and antistatic bag Inspect for damage Handle the board by its edges at all times Do not touch any card components 2 Locate the COM and IRQ jumpers on the internal modem Hold the internal modem by the metal slot cover with the board facing up The jumpers will be on the top lefthand side closest to the card edge connectors The jumpers will be positioned across the pins 3 Depending on the software loaded on your NAM II set the jumpers according to the settings in Table 5 The grey blocks signify where the jumpers are to be placed Table 5 Internal modem IRQ and COM settings
59. e of the SBC Reconnect the three ribbon cable connectors to the top of the SBC Refer to Figure 52 on page 101 for the proper alignment of the connectors 16 Check the dip switch settings to ensure they are in the proper position Use a small screwdriver to adjust the dip switches Refer to Table 9 on page 104 and Table 10 on page 104 for the SBC dip switch settings 17 Table 9 contains the dip switch settings for systems that do not have an SVGA video card installed Table 10 contains the dip switch settings for systems that have an SVGA video card installed Installation and Maintenance M anual Norstar Applications Module Il NAM II 104 Installing and replacing the Single Board Computer SBC Table 9 SBC dip switch settings for systems without an SVGA video card installed Position 1 2 3 4 5 6 State off off off on on 7 8 9 on on on off Table 10 SBC dip switch settings for systems with an SVGA video card installed Position 1 2 3 4 5 6 State off off off on on 7 8 9 on on off off Note To set a dip switch to off the switch must be up and point away from the SBC To set a dip switch to on the switch must be down towards the SBC 18 Replace the front cover 19 Plug the power cord into the AC outlet Norstar Applications Module II NAM Il Installation and Maintenance Manual Section IV ACCESS Server Administration e Prepa
60. econds a Quick shutdown is performed Installation and Maintenance M anual Norstar Applications Module Il NAM II 122 Using the ACCESS Server administration software from a terminal Before you can access the System Shutdown option the ACCESS Server Administration Menu must appear on your monitor For more information about accessing the Server Administration software refer to Using the ACCESS Server administration software from a terminal on page 113 earlier in this section To shutdown the NAM II 1 Start from the ACCESS Server Main Menu 2 Press to select System Shutdown and then press Reurn The screen shows The system shutdown procedure will check that all the appli cations running on the server and registered with ACCESS are not running before shutting down the system Options Graceful 1 2 Quick 3 Immediate Q Quit Enter the Shutdown Option 3 Press the number of the Shutdown option you want 4 A confirmation screen appears 5 Press Y if you want to proceed with the System Shutdown 6 The NAM I issues a series of tones descending in pitch when the shutdown is complete Wait for the tones before you unplug the NAM II 7 Unplug the NAM II Rebooting the NAM Il This option allows the installer to reboot the system The Reboot option makes sure all applications are terminated before a reboot is performed The Reboot screen provides you with three options Graceful Quick and Immedia
61. ectors from the top of the SBC Refer to Figure 43 on page 80 Use both hands to carefully hold the SBC along the top Lift the SBC straight up and out from the module Sometimes the SBC is tightly seated and hard to remove You may need to wiggle it out with a slight rocking motion If you are returning the NAM II for service place the SBC in an antistatic bag Package the SBC with plenty of shock absorbing insulating material Unpack the replacement SBC from the shipping container and antistatic bag Inspect for damage Handle the board by its edges at all times Do not touch any card components Carefully hold the card along the top only and insert the card into the module by aligning it over the backplane connector Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing and replacing the Single Board Computer SBC 103 Figure 53 Installing the SBC 12 Push the card straight down until it fits snugly in place Ensure the edge connector is firmly inserted into the backplane connector Refer to Figure 53 13 Fasten the slot cover screw 14 Reconnect the Serial Port A and Serial Port B connectors to the SBC Reconnect the keyboard mouse connector to the SBC Refer to Figure 43 on page 80 for the location of the connectors 15 Reconnect the reset and speaker two brown connectors to the top sid
62. els for an application you must reboot the NAM II in order for the changes to take effect To set the minimum and maximum number of Channels for an application 1 Press Feature fo ft jis Password 2 Enter the default password 2 2 J 2 3 7 7 J 2 LITITITISIPRETRY_ ACCESS2 ACCESS Server 3 Press ADMIN A J Prt queuejmgr 4 Press NEXT until the display shows the Voice and QUI TJ HERTS SHOW Fax heading C Voices amp Fax 5 Press SHOW QUITS J NEXT SHOW Norstar Applications Module Il NAM Il Installation and Maintenance Manual Using the ACCESS Server administration software from a telephone set 131 appl 6 Voice Ports 10 QUITI MI f MAX Min ports X 11 DECIS INCT OK Min ports X y als DECI INCI OK lt Applicati on gt BB QUI TI NEXT SHOW a Voice Port 14 QUI TSI NEXT SHOW Voice Ports le Lo QUIT MINS f MAX Installation and Maintenance Manual Press SHOW until the display shows Press NEXT until the application you want appears Press SHOW when the application you want appears on the screen Press SHOW to change the minimum and maximum number of Voice Channels Note Press NEXT and SHOW to change the minimum and maximum number of Fax Channels and follow ste
63. es to the NAM II are required when additional capacity or functionality is needed This section describes upgrade or replacement procedures for the following e clock calendar battery e Digital Fax Card DFC e Digital Voice Cards DVC and Voice Channels e floppy disk drive e hard disk drive e internal modem e memory e monitor keyboard and mouse e Single Board Computer SBC O nly on systems with applications that support FAX functionality For example Norstar Voice Mail Refer to Figure 2 on page 7 for the location of the NAM II interior components Note The power supply is not a field replaceable part Installation and Maintenance M anual Norstar Applications Module Il NAM II 28 Preparing for the upgrade Special tools Before you begin replacing or upgrading the components ensure you have the following equipment e 2 Phillips head screwdriver that has a blade 3 5 in long e 3 16 in slot screwdriver e an antistatic grounding strap e 3 16 in nut driver recommended CAUTION You must wear an antistatic grounding strap at all times when handling electronic components Failure to do so may result in damage to the equipment Norstar Applications Module II NAM Il Installation and Maintenance Manual Preparing for the upgrade 29 Shutting down the NAM Il This option allows the installer to gently shutdown the NAM II OS 2 Warp requires a slow shutdown to guarantee the integrity of the file
64. ess SHOW BACK NEXT SHOW Reboot ftype 5 Press GRACE QUI Tf NEXT f GRACE Note Press NEXT to change the shutdown option to QUI CK Quick MMD Immediate or SCHDL Scheduled 6 Press YES Note Press NO if you want to stop the reboot Installation and Maintenance M anual Norstar Applications Module Il NAM II 136 Using the ACCESS Server administration software from a telephone set Scheduling a reboot of the NAM II This option allows you to schedule a time to reboot the system This makes it possible to schedule a reboot of the system when it is not busy The reboot option ensures all applications are terminated before a reboot is performed You must enter the time of the day the day month and year of when you want the reboot to take place When the entered time is reached the system will automatically reboot itself To schedule a reboot of the NAM II 1 Press Feature 9 fa 5 Password 2 Enter the default password 2 2_ 2 3 J 7 EJ PETTITT TIPRETRY J ACCESS2 ACCESS Server 3 Press NEXT until the display shows BACK I HESTI ADMIN System reboot 4 Press SHOW BACK NEXT SHOW Reboot type 5 Press NEXT until the display shows QUI Tf HEXT GRACE Reboot type 6 Press SCHDL QUI TI NEXT SCADE Vyyymmdd e e 7 Press TIME QUIT RETRY TIME Norstar
65. g frequency in millions of cycles per second Microprocessor A chip that is the center of all activity inside the Applications Module The microprocessor controls all logical and arithmetic operations for the computer and is responsible for executing program commands It is also referred to as the Central Processing Unit CPU Modem A communications device that allows data to be exchanged between computers over telephone lines The exchange is done by electronic processes called modulation and demodulation The modem changes modulates the data into tones to send to another modem and also converts demodulates tones when receiving from another modem M7100 telephone The Norstar model M7100 telephone that has a single line display and one programmable button without an indicator M7208 telephone The Norstar model M7208 telephone that has a single line display and eight programmable buttons with indicators M7310 telephone The Norstar model M7310 telephone that has a two line display with three display buttons 10 programmable buttons with indicators and 12 dual programmable buttons without indicators M7324 telephone The Norstar model M7324 telephone that has a two line display with three display buttons and 24 programmable buttons with indicators Network Two or more computers linked together electronically to share programs and exchange data Joining computers over a network requires adding specialized hardware and s
66. h DVC on page 58 and Removing the first DVC on page 60 Installation and Maintenance M anual Norstar Applications Module Il NAM II 44 Installing the Digital Fax Card DFC 2 Remove the PEB terminator XRN2 from DVC1 by placing a flat head screwdriver between the terminator and its socket and gently pry the terminator loose Note Refer to Figure 22 for the location of the PEB terminators Figure 22 PEB terminator locations PEB connector PEB terminator XRN1 PEB terminator XRN 2 Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing the Digital Fax Card DFC 45 3 Remove both PEB terminators XRN1 and XRN2 from any remaining DVCs Note Save the PEB terminators after removing them from the DVCs You will need to re install them on the DVCs if the DFC is removed 4 Connect one end of the PEB cable to the PEB socket on the DFC The PEB cable is keyed and can only be installed one way You must also ensure the Pin 1 indicator colored stripe is on the edge furthest away from the top of the module Figure 25 Installing the PEB Cable PEB Cable au ae Fax Card iem IBGE 5 Insert t
67. he DVCs and connect the PEB cable to each card To ease installation start with the DVC that is closest to the DFC and finish with the DVC farthest away Also make sure you connect the PEB cable before you insert the next DVC If you have less than four DVCs installed the remaining connectors on the PEB cable can remain empty 6 Fold the PEB cable so it lies flat against the card edges 7 Insert the FXENABLE diskette into the floppy disk drive 8 Plug the power cord into the AC outlet and wait for the NAM II to boot from the disk This should take two or three minutes 9 Once all disk activity has ceased and the light on the floppy disk drive has gone out unplug the NAM II and remove the FKENABLE diskette from the floppy disk drive 10 Replace the front cover Insert the tongues on the bottom of the front cover into the module slots 11 Fasten the two screws holding the front cover to the module Installation and Maintenance M anual Norstar Applications Module Il NAM II 46 Installing the Digital Fax Card DFC 12 Close the module door To lock the door turn the lock 90 clockwise until the screwdriver slot is horizontal 13 Plug the power cord into the AC outlet Upgrading the DFC The DFC can be upgraded from two to four Channels by adding a 2 Channel daughterboard to the 2 Channel base card The DFC must be removed from the NAM II in order to add the expansion card Figure 26 The DFC expansion card
68. he PEB cable to the DFC Installation and Maintenance M anual Norstar Applications Module Il NAM II 48 Installing the Digital Fax Card DFC 5 Replace the front cover Insert the tongues on the bottom of the front cover into the module slots 6 Fasten the two screws holding the front cover to the module 7 Close the module door To lock the door turn the lock 90 clockwise until the screwdriver slot is horizontal 8 Plug the NAM II power cord into the AC outlet The additional two fax Channels are automatically enabled and ready to be used Removing fax functionality from the System These steps are to be used only if you are removing the DFC and fax functionality from a NAM II that is equipped with Norstar Voice Mail If you are replacing the DFC or upgrading the DFC refer to Installing the DFC on page 40 or Upgrading the DFC on page 46 WARNING The microprocessor heat sink may be hot Pay careful attention not to touch the heat sink when installing the PEB cable Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing the Digital Fax Card DFC 49 To remove fax functionality from the NAM II 1 10 11 12 13 Shut down the module For more information refer to Shutting down the NAM II on page 29 Remove the power cord from the AC outlet Open the module door and remove the front cover Refer to Accessing the inside of the NAM II on page 30 Locate
69. he cables through the ends of the cable trough or through the back 8 Plug the power cord into the AC outlet If you are installing the monitor package do not plug the module in until the installation is complete Installation and Maintenance M anual Norstar Applications Module Il NAM II 22 Installing the NAM Il Installing the end caps To install the end caps l 2a Make sure the front cable trough door is open Place the bottom of the end cap into the slot in the bottom of the trough There are two end caps one for the left side and one for the right side of the cable trough Slide the end cap straight back to the end of the slot Connecting to the KSU Before you begin connecting to the KSU ensure a Norstar station port is available at the distribution block prior to booting the unit For instructions on installing a station port refer to the Norstar Installation Guide that came with the Norstar KSU To wire the NAM II to the KSU 1 2 Locate the distribution block Ensure there is one station port available at the distribution block for each DVC station port For instructions about installing a station port refer to the Norstar Installation Guide that came with the Norstar KSU Mount the teladapt jacks next to the distribution block Using twisted pair station wire connect the teladapt jacks to free station ports on the distribution block Test the port using a working Norstar telephone Co
70. he floor to the installation area should be enough to prevent water damage Electrical Checklist CAUTION A Before connecting 230 V AC to the NAM Il you must change the power supply switch to 230 V AC Failure to do this will severely damage the NAM II Refer to Changing the power supply voltage on page 98 Voltage Nominal voltage V Voltage range V Nominal current A Maximum selected V current A 115 100 to 125 90 to 137 2 5 230 200 to 240 180 to 265 1 2 5 The electrical supply must be 3rd wire ground J unswitched Note The NAM II does not require a dedicated circuit Do not connect the NAM II to an AC outlet on a circuit that is likely to be overloaded or used by large office equipment or power tools Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing the NAM Il 17 Special parts and equipment For the installation you need the following equipment a a a a a a a Oy Phillips 2 screwdriver power drill flat blade screwdriver antistatic grounding strap four 10 X 2 5 cm 10 X 1 inch round head wood screws twisted pair station wire plywood backboard 2 cm 3 4 inch thick surge protector recommended Other documentation In addition to the documentation included in the package you received the Norstar Installation Guide that came with your Norstar KSU may also be necessary If your NAM II is equipped with a
71. hows commands and options Display buttons The three buttons that appear underneath Norstar two line LCD display Display options The choices available to a user that appear on the Norstar two line display Options appearing on the display can be selected using the display or dialpad buttons Extended Data Out EDO Extended Data Out EDO is a form of Dynamic Random Access Memory RAM in which storing data to and reading data from the memory is performed at a faster rate FAX FAX works with Norstar Voice Mail and Norstar offering a caller the capability of sending a fax document to a mailbox as easily as sending a voice message Feature Code A unique three digit code used to access NAM II Features and options File A collection of related information stored on a disk under a given name for later reference and used by an operating system or application program Each application program that you use saves the data you create in files Files are identified by a file name and optional extension Norstar Applications Module II NAM II Installation and Maintenance Manual Glossary 151 File name A name that identifies a file and consists of one to eight characters Hard disk drive A data storage device that uses non removable rigid magnetic platters Hard disk drives work faster and store more data than disk drives do for diskettes Hardware The physical components of the NAM II Hz hertz A unit of measure for indic
72. ication parameters refer to the user manual that came with the RS 232 terminal The NAM II communication parameters are e 9600 baud e 8 data bits e 1 stop bit e no parity Set the terminal communication parameters to these values For instructions refer to the terminal operating manual When configuring the terminal NAM II supports carriage return Note Your terminal must be VT100 compatible and must support the VT100 National Character set If the terminal does not support the VT100 National Character set text will be incorrectly presented Using terminal emulation If you have a laptop computer equipped with a terminal emulation package you can use it in the place of an RS 232 terminal For more information about terminal emulation refer to the terminal emulation documentation that came with your PC Connecting an RS 232 terminal or laptop computer You must open the Norstar applications server s cable trough door before you can connect the RS 232 terminal or laptop computer You must use a null modem serial cable to connect the NAM II to an RS 232 terminal or laptop computer If the connector on the cable is not a 25 pin RS 232 connector refer to the operating manual of the terminal you are connecting for instructions To connect the RS 232 terminal to the NAM II 1 Pin 2 on one end is connected to pin 2 on the other end pin 3 on one end is connected to pin 3 on the other end and pin 5 on one end is connected to pin
73. imultaneous Voice Channels called B1 and B2 For example one DVC with two station ports supports four simultaneous Voice Channels Before you start Before you start the installation ensure that you e read this guide and understand the installation process e verify that all conditions are met in the checklists Packaging Checklist Make sure the package you received contains the following items T NAM II the NAM II wall mounting bracket C an AC power cord a teladapt cord for each DVC station port Installation and Maintenance M anual Norstar Applications Module Il NAM II 16 Installing the NAM II Environment Checklist The installation area must be C at least 4 m approximately 13 feet from equipment such as copiers electrical motors and other equipment that could produce electromagnetic radio frequency and electrostatic interferences within 305 m approximately 1000 feet of the Norstar KSU within 1 5 m approximately 5 feet of a three wire grounded electrical outlet clean free of traffic and excess dust dry and well ventilated between 10 and 40 Celsius approximately 50 to 104 Fahrenheit between 8 and 80 non condensing relative humidity a wall area approximately 1 m square approximately 10 sq feet a Se er Se ed a minimum of 16 cm approximately 6 inches from a corner wall or other component a minimum of 46 cm approximately 18 inches from the floor Note The distance from t
74. ine or a caller that Voice Channel cannot be used by other users until the fax function is complete Only one DFC can be installed in the NAM II The DFC connects to the DVCs through the PCM Expansion Bus PEB cable This cable must be connected from the DFC to each DVC The PEB cable connects the DFC to the DVC to share the Channels connected to Norstar The following section provides step by step instructions for the installation of a DFC and PEB cable Figure 17 Digital Fax Card and PEB cable PEB connector PEB terminator Digital Fax Card PEB cable Installation and Maintenance M anual Norstar Applications Module Il NAM II 40 Installing the Digital Fax Card DFC Precautions Before installing or upgrading a DFC you MUST take the following precautions Unplug the NAM II power cord The NAM II power supply contains high voltage If you do not unplug the power cord you may severely injure yourself Also if cards are installed or removed from the NAM II before the power cord is unplugged the cards and or the NAM II may be damaged Wear a ground strap Static electricity can damage the components on the cards and the NAM II Always wear a properly grounded antistatic strap while handling the DFC DVC or any other component of the NAM II Installing the DFC 1 Shutdown the
75. ion about cabling requirements modem settings and communication parameters Table 13 Pin connection NAM II serial port Modem pin 2 transmit connects to pin 3 receive pin 3 receive connects to pin 2 transmit pin 5 ground connects to pin 5 ground Note The NAM II RS 232 port is a standard 9 pin RS 232 connector Refer to Table 13 for the proper cable to connect the modem to the NAM II Installation and Maintenance M anual Norstar Applications Module Il NAM II 112 Preparing to use the ACCESS Server administration software Norstar Applications Module II NAM Il Installation and Maintenance Manual Using the ACCESS Server administration 1 6 software from a terminal Overview This chapter provides information on accessing the Access Server from a terminal For information on accessing the ACCESS server from a telephone set refer to Using the ACCESS Server administration software from a telephone set on page 127 The ACCESS Server Administration software is invoked by attaching a terminal or laptop computer to Serial Port A COM1 of the NAM II and then pressing Reurn When the module has a terminal attached the Server Administration software automatically runs To start the Server Administration software 1 Ensure the RS 232 terminal or laptop computer is correctly connected to Serial Port A COM1 of the NAM II Refer to Using an RS 232 terminal or laptop PC on page 108 for more informatio
76. ional 8 MB SIMM in memory slot 2 The microprocessor and the clock calendar battery are also located on the SBC The NAM II supports seven expansion slots for card connection and five ports for device connection Refer to Table 1 on page 6 for more information about the components of the NAM II Figure 2 through Figure 6 summarize the ports and Expansion Bus slots available Installation and Maintenance M anual Norstar Applications Module Il NAM II 8 Components of the NAM Il Note Expansion Bus slots 2 5 6 and 7 are allocated for DVCs and slot 8 for a Digital Fax Card DFC If a PCIB card or Norlink is used a DVC cannot be present anywhere on the Expansion Bus lf Automatic Call Distribution ACD is installed on the system slot 8 is reserved for the SVGA card A DFC cannot be installed on a system with ACD Digital Voice Cards DVC The DVC is an expansion card that converts and compresses analog voice signals to digital data for storage on the hard disk Each DVC provides the NAM II with four TCM Voice Channels The DVC has two ports that each provide two Voice Channels B1 and B2 and one control channel D The control channel is the NAM I s physical connection to the Norstar KSU and allows the NAM II to send instructional messages to the KSU and vice versa Channels on the DVC are enabled through a specific upgrade procedure Refer to Increasing the number of Voice Channels on page 51 for more information about enabling DVC
77. ions you can share Voice or Fax Channels between the applications The ACCESS Server allows you to allocate Voice Channels by giving an application sole ownership of a Voice Channel or by assigning the Channel to a Channel Pool where it is shared by all applications You must assign a minimum and maximum number of Channels to be used by each application running on the NAM II Setting the minimum number of Channels dedicates a specific number of Channels to that application Setting the maximum number of Channels allows you to choose the maximum number of Channels an application can use The maximum Channel setting is a combination of the dedicated and shared Channels For example if you want an application to have 4 dedicated Channels and 2 shared Channels the minimum setting would be 4 and the maximum setting would be 6 The minimum number of Channels must not be greater than the number of Channels that are enabled for the application For example if an application has 6 Channels enabled and the minimum value is set to 8 2 Channels are being dedicated to an application that cannot use them The maximum number of Channels cannot be greater than the maximum number of Channels allowed for an application For example Norstar Voice Mail can have a maximum value of 16 Channels MINUET can have a maximum value of 4 Channels and Norstar IVR applications can have a maximum of 16 Channels After you have changed the minimum or maximum number of Chann
78. ith the limits for a Class A computing device pursuant to Part 15 of the FCC rules and CSA specification C108 8 which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case users will be required at their own expense to take whatever measures necessary to correct the interference This apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations for the Canadian Department of Communications This equipment has been verified to comply with the limits for Class A computing device pursuant to FCC Subpart B and ICES 003 Canadian EMI requirements with the peripherals recommended by Nortel for use with this equipment To resolve problems with interference resulting from use of peripherals not specifically marketed by or recommended by Nortel contact the manufacturer or dealer of that peripheral for assistance Only peripherals computer input output devices terminals printers etc certified to comply with Class A limits may be attached to this computer Operation with non certified peripherals is likely to result in interference to radio and television reception CAUTION A The Norstar Applications M odule contains fragile electronic parts DO NOT DROP OR BUMP THE MODULE Installation and Maintenance M
79. kup disk and press OK Wait until the restore completes Norstar Applications Module Il NAM II 72 Installing and upgrading the hard disk drive iS 9 Press OK ITTY TOK 10 Press to Ris end this ACCESS programming session Adding a secondary hard disk drive Before you can install a secondary hard disk drive you must remove the hard disk drive bracket from the NAM II When you are adding a secondary hard disk drive installation is easier if you first loosen two screws on the first drive You must make sure you tighten all screws on the first disk drive when installation is complete You must back up the capabilities file SEKUR The SEKUR file contains all upgrade and capability information about your system including the number of voice channels and any upgrades to your system The SEKUR file must be restored if a hard disk failure occurs If this file is lost and your hard disk drive fails all upgrades made to your system will be lost Refer to Backing up the NAM II capabilities file on page 67 Adding a secondary hard disk drive 1 Remove the hard disk drive and bracket from the NAM II Refer to the figure Removing the hard disk drive on page 68 Do not remove the primary hard disk drive from the bracket 2 Fasten the secondary hard disk drive to the bracket next to the primary hard disk drive The secondary hard disk drive must be positioned with the bottom of the hard disk drive the side with the expose
80. l FAX installed Norstar Applications Module II NAM Il Installation and Maintenance Manual Troubleshooting 143 To check the Channel Status d I RETRY BACK HEST ACCESS Server ADMIN J Channel Sta BACK NEXT tus SHOW Chanf Status QUITS ALL Menu SHOW A 01 xx gt cr win CC QUITS CLR DETAIL Installation and Maintenance Manual Press Enter the default password ACCESS2 Press NEXT until the display shows Press SHOW Press SHOW to show the status of a range of Channels The first range shows Channel 1 to 8 The second range shows Channel 9 to 16 The third range shows Channel 17 to 24 The fourth range shows Channel 25 to 32 Press ALL to view all 32 Channels at once Press DETAIL for specific details about the individual Channels 01 xx represents the first 8 Channels The display Cr CC is an example of a display Each of the 8 characters on the display signifies a Channel number For example Channel number one s status is Channel two s status is r The display information is updated every two seconds The information appearing on the display will vary depending on the number of DVCs or if a BIC is installed or if other applications are installed and using Channels Refer to Table 14 on page 145 for a definition of the Channel Status symbols Note Press QUIT to return to the Channel Sta
81. l Norstar Applications Module Il NAM II 58 Installing and upgrading the Digital Voice Cards DVC s 12 13 14 15 16 17 18 19 Locate expansion slot 2 Refer to Table 3 on page 54 for more information about the different card slots Remove the slot cover screw and the metal slot cover Gently push the large ribbon cables leading to the SBC flat against the backplane This will allow for easier installation of the DVC Carefully hold the DVC along the top Insert the card by aligning it between the metal groove on one side and the slot opening on the other side Push the DVC straight back and down until it fits snugly in place Ensure the edge connector is firmly inserted into the socket Reconnect the Serial Port A and Serial Port B connectors to the SBC Reconnect the keyboard mouse connector to the SBC Refer to Figure 34 for the location of the connectors Note Ensure the keyboard mouse ribbon cable is still connected to the backplane Fasten the slot cover screw in the DVC slot cover Replace the front cover Plug the power cord into the AC outlet Removing the second third or fourth DVC This procedure is for removing the second third or fourth DVC from the NAM II These DVCs will be located in slots 5 6 and 7 respectively If you are removing the first DVC from slot 2 refer to Removing the first DVC on page 60 A DVC is removed when a failure is suspected or confirmed Note If your
82. l tools earlier in this section for equipment recommendations 1 Shutdown the NAM II For more information refer to Shutting down the NAM II on page 29 2 Remove the NAM II power cord from the AC outlet 3 Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface 4 Remove the front cover Refer to Accessing the inside of the NAM II on page 30 5 Disconnect the power supply wiring and ribbon cable from the hard disk drive If another hard disk drive is installed its wiring and cabling must also be disconnected Norstar Applications Module Il NAM Il Installation and Maintenance Manual Installing and upgrading the hard disk drive 69 6 The hard disk drives are held by a bracket attached to the module wall Undo the two nylon fasteners at the top and bottom of the bracket by grasping each fastener and gently pulling it away from the module wall The fastener moves out from the module wall but remains attached to the bracket CAUTION Ensure the hard disk drive bracket does not fall onto the module components Figure 38 Removing the hard disk drive mounting bracket 7 Lift the bracket out of the module 8 Remove the four screws that fasten the hard disk drive to the bracket Two screws are located on each side of the hard disk drive 9 Pull the hard disk drive out from the bracket Installation and Maintenance M anual Norst
83. lastic case you must ensure that the two screws in the cable trough that secure the module to the wall are in place To remove the plastic case 1 Shutdown the NAM II Note For more information refer to Shutting down the NAM II on page 29 Open the cable trough Remove the NAM II power cord from the AC outlet Remove the front door by unclipping it from its three hinges Remove the six screws mounted around the front edge of the plastic case Note The screws are deeply recessed in the plastic case Pull the plastic case towards you and away from the module Norstar Applications Module Il NAM Il Installation and Maintenance Manual Preparing for the upgrade 33 Figure 15 Removing the plastic case in LN Sg y J AALL rel liin D To replace the plastic enclosure 1 Place the plastic enclosure on the module and fasten its six screws to the module 2 Replace the door by clipping it to its hinges 3 Plug the power cord into the AC outlet 4 Close the cable trough door Installation and Maintenance Manual Norstar Applications Module Il NAM II 34 Preparing for the upgrade Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing the clock calendar battery D Overview The clock calendar battery is responsible for keeping BIOS information current if the power to the module goes down The BIOS contains information such as the unique serial nu
84. ls 117 Installing and removing applications 119 Changing the ACCESS Server Password 120 Backing up and restoring the capabilities file 121 Shutting down the NAM IT 121 Rebooting the NAM II 122 Server Diagnostics 124 System password control 125 Using the ACCESS Server administration software from a telephone set 127 Overview 127 Changing the printer options 127 Setting the DTMF digit duration length 128 Viewing the Alarm and Message Log 129 Norstar Applications Module II NAM Il Installation and Maintenance Manual Sharing Voice and Fax Channels between applications 130 Installing applications 132 Viewing the NAM II serial number 133 Shutting down the NAM II 134 Rebooting the NAM II 135 Scheduling a reboot of the NAM II 136 Troubleshooting 137 Chapter 18 Troubleshooting 139 Overview 139 Diagnosing problems 140 Hardware problems 140 Checking the Channel Status 142 Disabling and Re enabling Norstar Voice Mail Channels 145 Preparing the NAM II for travel 147 Glossary 149 Index 155 Installation and Maintenance M anual Norstar Applications Module Il NAM II vi Norstar Applications Module Il NAM II Installation and Maintenance Manual Regulatory information vii Regulatory information The Norstar Applications Module generates radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and found to comply w
85. lug the power cord into the AC outlet Installation and Maintenance M anual Norstar Applications Module Il NAM II 96 Adding and removing a monitor keyboard and mouse Norstar Applications Module II NAM Il Installation and Maintenance Manual Changing the power supply voltage 1 3 Overview The power supply converts AC line voltage to DC It provides 5V DC and 12V DC to the backplane and disk drives Table 8 shows the voltage requirements of the different components WARNING There is high voltage in the power supply Before you work with the power supply make sure the AC power cord is unplugged Table 8 Power supply specifications Connector Pin Volts 1 Backplane Power good 5 12 12 5 6 DC return ground 2 Backplane 1 2 DC return ground 5 4 5 6 5 3 Floppy disk drive 1 5 2 3 DC return ground 4 12 4 Secondary hard disk drive 1 12 2 3 DC return ground 4 5 5 Primary hard disk drive l 12 2 3 DC return ground 4 5 Be w N e Installation and Maintenance Manual Norstar Applications Module Il NAM II 98 Changing the power supply voltage Changing the power supply voltage The power supply is set at the factory to operate at 115 volts but the power supply can be changed to operate at 230 volts for countries where this is the standard If you are changing the power supply voltage setting to 230 volts the NAM II m
86. mber of the NAM II system The battery must be replaced with a 3 V 170 mAh lithium coin cell such as a Sanyo CR2032 WARNING If you do not replace the battery with a 3 V 170 mAh lithium coin cell battery there is a danger of explosion Removing and replacing the battery To remove the battery 1 Shutdown the NAM II For more information refer to Shutting down the NAM II on page 29 Remove the NAM II power cord from the AC outlet Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface Remove the front cover Refer to Accessing the inside of the NAM II on page 30 Remove any expansion bus cards that interfere with access to the battery Using your finger gently lift the metal clamp that is holding the battery in the socket The socket is located on the SBC For the location of the battery refer to Removing the battery on page 36 If the battery doesn t immediately fall out of the socket gently wiggle the SBC This will cause the battery to drop out of the socket into your hand Installation and Maintenance M anual Norstar Applications Module Il NAM II 36 Installing the clock calendar battery CAUTION Do not use any type of tool to remove the battery Figure 16 Removing the battery Norstar Applications Module II NAM Il Installation and Main
87. memory SIMMs make sure you ground yourself by attaching one end of the grounding strap to your wrist and the other end to the NAM II CAUTION A Do not use an electric screwdriver or any other magnetized tools near the SIM Ms The SIMMs may be disrupted Refer to Special parts and equipment on page 17 for equipment recommendations To add memory 1 Shutdown the module For more information refer to Shutting down the NAM II on page 29 2 Remove the NAM II power cord from the AC outlet 3 Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface 4 Remove the front cover Refer to Accessing the inside of the NAM II on page 30 Installation and Maintenance M anual Norstar Applications Module Il NAM II 80 Adding and replacing memory 5 Disconnect the Serial Port A and Serial Port B connectors from the SBC Disconnect the keyboard mouse connector from the SBC Refer to Figure 43 on page 80 6 Disconnect the reset and speaker two brown connectors from the side of the SBC Disconnect the three ribbon cable connectors near the top of the SBC Refer to Figure 43 7 Remove the SBC slot cover screw Refer to Figure 35 on page 59 Figure 43 Disconnecting connectors and ribbon cables from the top of the SBC Port 80 LEDs Microprocessor Reset and speaker two brown Connectors Pes Ribbon cable Connectors lt a SBC dip switches
88. mponents are located Installing the NAM II This section provides the steps necessary to install a NAM II NAM II Hardware Upgrades and Replacements This section provides the steps necessary for upgrading or replacing various NAM II components ACCESS Server administration This section explains how to use the ACCESS Server administration software for a variety of maintenance functions Troubleshooting This section provides procedures for diagnosing and solving problems concerning the NAM II Installation and Maintenance M anual Norstar Applications Module Il NAM II 2 How to use this manual Knowing the symbols This manual uses certain symbols to draw your attention to important information You should pay attention to the following Caution Symbol Alerts you to situations where there is the possibility of damaging the equipment gt Warning Symbol Alerts you to situations where there is the possibility of injuring yourself gt Note A Note alerts you to information that is particularly critical or noteworthy Alerts you to remove the NAM Il power cord from the AC outlet before performing the maintenance procedure OR Alerts you to ground yourself before performing the maintenance procedure lt lt Norstar Applications Module II NAM Il Installation and Maintenance Manual Section NAM II Components e Components of the NAM Il e NAM Il System software In
89. n 2 Press Reurn The screen shows Select the language 1 English 2 Frangais Q Quit Enter Selection Number 3 Press for English or for French then press Reum The screen shows Enter the Login Password Installation and Maintenance M anual Norstar Applications Module Il NAM II 114 Using the ACCESS Server administration software from a terminal 4 Type ADMIN and then press Reurn Note This password must be entered in capital letters with no spaces The screen shows Detailed Concise Mode Enter Q to Quit Select detailed mode y 5 Press Y to select detailed mode Press N to select concise mode and then press Reurn The screen shows the ACCESS Server Main Menu ACCESS Server Menu Application Administration Server Diagnostics System Shutdown System Reboot System Password Control Q Quit Enter Selection Number The ACCESS Server Menu is the Main Menu for the Server Administration software From this menu you can e administer the system functions of any application running on the NAM II such as the NAM II application e view what hardware configuration the NAM II contains e shutdown the NAM II e reboot the NAM II e change the Server password e access the NAM II Administration software Norstar Applications Module Il NAM Il Installation and Maintenance Manual Using the ACCESS Server administration software from a terminal 115 Administering an
90. n If a new Channel has been connected to the KSU or DVC card has been added you will have to quit the Channel Status session and re enter Channel Status in order to view the changes Norstar Applications Module Il NAM II Installation and Maintenance M anual Troubleshooting 145 Table 14 Channel Status Symbols Channel Status Symbol Definition of symbol The Channel is installed and functioning but is currently idle The Channel is ringing The Channel is either receiving a call or is attempting to make a call The Channel is connected and is on an active call The Channel is connected to the KSU butis notactivated for any applications A Channel is detected but there is a connection problem No Channel detected No card installed Disabling and Re enabling Norstar Voice Mail Channels In the course of diagnosing a system problem you may find it necessary to disable a particular NAM II Channel After the problem has been solved you will need to re enable the Channel If you attempt to disable all the Channels the system will reboot itself To disable a Channel d LP PRETRY BACK HERT ADMI N Channel Status BACK NEXT SHOW QUIT NEXT DSBL QUIT NEXT ENBL oe Installation and Maintenance M anual ACCESS Server 3 4 Chan Status Menu 5 QUIT JALL SHOW 01 08 gt ccc crr 6 QUIT NEX
91. n DTMF duration to take effect 9 Press to end this session Viewing the Alarm and Message Log The Alarm and Message Log keeps a record of system alarms and messages Alarms and messages that repeat within five minutes will not be recorded unless other alarms or messages occur in the intervening time This option allows you to view the alarms or clear the entire log file To view the Alarm and Message Log 1 Press Feature 9 1 5 Password 2 Enter the default password 2 2 J 2 3 7 7 J 2 LUTITITISIPRETRY_ ACCESS2 ACCESS Server 3 Press ADMIN A J Prt queuejmgr 4 Press NEXT QUI Tf HEST SHOW B Alarmsj amp jMsgs 5 Press SHO QUIT NEXT SHOW 1 View Log 6 Press SHOW to view the log QUI Tf NEXT SHOW Note Press NEXT then OK to clear the log Start fof flog 7 Press NEXT to scroll through the Alarms BACK NERTI 1 QUIT ALM lt Port 3 59 gt 8 Press NEXT to continue viewing the Alarms BACKI NERTI T ME 9 Press to end this session Installation and Maintenance M anual Norstar Applications Module Il NAM II 130 Using the ACCESS Server administration software from a telephone set Sharing Voice and Fax Channels between applications If you are running multiple applications on the NAM II such as Norstar Voice Mail MINUET or Norstar IVR applicat
92. nce M anual Components of the NAM II 7 Figure 2 Interior components Microprocessor Hard disk drive __ Single Board Computer SBC Clock calendar E Slot 4 battery HE Floppy disk drive Internal modem Slot 3 Expansion card slots Expansion card slots Figure 2 shows the location of the hardware components in the NAM II We recommend you familiarize yourself with the location of the different components before working with the system All connections located at the bottom of the NAM II are accessed from the cable trough Single Board Computer SBC The Single Board Computer SBC is the main computing device of the NAM II All tasks such as answering incoming calls playing recorded announcements and storing voice messages are controlled by the SBC The NAM II is equipped with either 8 MB or 16 MB of EDO Random Access Memory RAM This memory is located in Single In line Memory Modules SIMMs on the SBC The first 8MB SIMM is located in memory slot 1 If the NAM Ilis equipped with 16 MB of RAM there will an addit
93. ng DVC 55 Documents required 17 Door 30 Drive Secondary hard drive 72 Drive floppy 65 Drives Floppy disk 8 Hard disk 8 DTMF 128 DVC functionality 5 E Electrical supply 16 Enabling the monitor 93 Enabling the monitor keyboard and mouse 93 End caps 22 Environment 16 F Fax card Cable 42 O verview 39 Removing 46 Slot 40 47 Fax card installing 40 Fax Channel sharing 130 Fax Channels Norstar Applications Module II NAM Adding 46 Allocating 130 Fax removing functionality 48 FCC regulations vii Floor mount stand Assembling 20 Attaching to the NAM II 20 Installing the end caps 22 Floppy disk drive 8 Installing 65 Removing 65 Front cover 30 31 Removing 31 Front door 30 H Hanging the NAM Il 18 Hard disk drive 8 Adding a secondary 72 Installing a new one 70 Removing 68 Hard drive space 67 Hardware 6 7 8 11 Components 7 Digital Voice Card DVC 8 Floppy disk drive 8 Hard disk drive 8 Modem 11 Network Interface Card 11 Ports 9 Power supply 8 Printer 11 Hardware problems 140 l IBM OS 2 Warp Operating system 12 Installation overview 17 Installation requirements 16 Installation tools 17 Installing Digital Fax Card 40 Installing an application 119 132 Internal components 30 Hard disk drive 70 Internal modem 75 Connecting to an ATA 78 Installing 76 Removing 76 J Jumper positions DFC 41 Installation and Maintenance Manual K Keyboard Enabling 93 Removing 95 Keyboar
94. nnect one end of each teladapt connection cord to the appropriate DVC station ports Connect the other end to the plug at the teladapt jack Do not use a teladapt cord that is longer than 2 1 m approximately 7 ft Note If your NAM II came with RFI filters connected to the DVCs you must connect the teladapt cord to the RFI filter that is connected to the DVC station port Norstar only uses the two center pins of a teladapt plug For example if you are using a Norstar standard six wire plug only pin numbers three and four are used All wiring and cabling should be run through the bottom or sides of the cable trough Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing the NAM Il 23 CAUTION A Do not place any other components such as a power bar into the NAM II cable trough Obstructions in the cable trough restrict a cooling air flow and may cause the unit to overheat Figure 12 Connecting the KSU to the NAM II Installation and Maintenance Manual Norstar Applications Module Il NAM II 24 Installing the NAM Il Connecting the internal modem After the NAM II has been mounted and connected to the KSU the internal modem must be connected The internal modem can either be connected to an Analog Terminal Adapter ATA or to an incoming Central Office CO line The internal modem is used for NAM II maintenance only This modem can
95. not be accessed by other users Refer to Connecting the internal modem to an Analog Terminal Adapter ATA on page 78 for information on connecting the internal modem Powering up the NAM Il 1 Plug in the NAM II Wait until the self diagnostics are completed This can take up to five minutes Read the power supply warning label covering the AC power plug before powering up the NAM IL CAUTION The power supply default setting is 115 volts For more information about changing the power supply voltage setting refer to Changing the power supply voltage on page 98 Norstar Applications Module II NAM Il Installation and Maintenance Manual Section IIl NAM Il Hardware Upgrades and Replacements e Preparing for the upgrade e Installing the clock calendar battery e Installing and upgrading the Digital Fax Card DFC e Installing and upgrading the Digital Voice Cards DVC s e Installing a new floppy disk drive e Installing and upgrading the hard disk drive e Installing a new internal modem e Adding and replacing memory e Adding or removing a monitor keyboard and mouse e Changing the power supply voltage e Installing or replacing the Single Board Computer SBC Installation and Maintenance M anual Norstar Applications Module Il NAM II 26 NAM Il Hardware Upgrades and Replacements Norstar Applications Module II NAM Il Installation and Maintenance Manual Preparing for the upgrade 4 Overview Hardware upgrad
96. o recognize the addition of the components To enable the monitor keyboard and mouse l BACKI NEXT ADMIN tfqueu A Pr e TJ NEST QU QUI TI JNEXT SHOW Password 6 QUIT If JJ RETRY J Monit 7 QUIT ADD REN GS 8 Installation and Maintenance Manual Access Server Vo 3s G fMonitor Pkg 5 Press Enter the ACCESS password Note The default password is ACCESS2 2223772 Press ADMI N Press NEXT until the display shows G Monitor Pkg Press SHOW Enter the default password Jee ete eeek SVGANEEDED Press ADD Reboot the system from a Norstar telephone For more information refer to Rebooting the NAM II on page 135 While the system is rebooting the monitor will go blank Watch the screen during the reboot When a small white OS 2 box appears in the top left corner you must immediately press Alt and F at the same time The flashing white box only appears on the screen for 2 seconds Note If you were unable to press Alt and F1 while the white OS 2 box appeared cycle the power to the NAM and repeat step 9 Norstar Applications Module Il NAM II 94 Adding and removing a monitor keyboard and mouse 10 When the Recovery Choices screen appears on the monitor press on the keyboard 11 The monitor keyboard and mouse have now been
97. odem Power cable A cable that connects the Applications Module to a power source RAM Random Access Memory Computer memory that stores data temporarily RAM stores the data used by the microprocessor as it executes instructions The contents of RAM are erased each time the Applications Module is turned off or restarted ROM Read Only Memory Memory that stores data permanently ROM contains instructions that the Applications Module needs to operate The instructions stored in ROM cannot be changed and are used by the Applications Module each time it is turned on or restarted Installation and Maintenance M anual Norstar Applications Module Il NAM II 154 Glossary Serial port A port that sends and receives data one bit at a time This port can be used to connect the Applications Module to a printer external modem or mouse Serial port connectors usually have nine pins and are designated by software with the letters COM and a single digit such as COM1 Single Board Computer SBC The Single Board Computer is the main computing device of the NAM II It runs the operating system and all applications installed on the NAM I The microprocessor clock calendar battery and four Single In Line Memory Modules SIMM slots are located on the SBC SIMM Single In line Memory Module The NAM is equipped with one SIMM that provides 8MB of EDO RAM or two SIMMs that provide 16 MB of EDO RAM The memory can be increased with the additi
98. oftware to each computer Operating system The disk based software that manages the operation of the Applications Module An operating system controls the flow of information between the computer hardware such as the keyboard video display disk drives and printer IBM OS 2 is the operating system that manages the Applications Module Norstar Applications Module II NAM II Installation and Maintenance Manual Glossary 153 Option A NAM II choice that is given to a user through display prompts Parallel port A port that transfers data through multiple wires so that eight bits are transmitted simultaneously Parallel ports usually use a 25 pin interface that transmits and receives data one byte at a time using a separate data line for each bit Password A four digit to eight digit number that is entered using the dialpad A password is used to open mailboxes or perform configuration tasks PEB PCM Expansion Bus A PEB cable is used to connect the Digital Voice Cards DVCs to the Digital Fax Card DFC when the FAX option is installed Peripheral A device that is connected to and communicates with a computer A printer and mouse are peripherals Pin 1 The first pin in a multiple pin connector or chip designated as such to help you properly orient the component when attaching or installing it Port A connector on the Applications Module that allows data exchange with other devices such as a printer mouse or external m
99. old the PEB cable so it lies flat against the card edges 15 Replace the front cover and close the module door 16 Plug the power cord into the AC outlet The DVC must be connected to the distribution block Refer to Connecting a DVC to the distribution block on page 55 Installation and Maintenance M anual Norstar Applications Module Il NAM II 64 Installing and upgrading the Digital Voice Cards DVC s Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing a new floppy disk drive 8 Overview When you are replacing the floppy disk drive you must remove the front cover and the plastic case enclosing the NAM II The screws holding the floppy disk drive in place are only accessible from the outside edge of the module Installing a new floppy disk drive To remove the floppy disk drive 1 Shutdown the module For more information refer to Shutting down the NAM II on page 29 Remove the NAM II power cord from the AC outlet Remove the front cover and plastic case For more information about removing the front cover and plastic case refer to Accessing the inside of the NAM II on page 30 Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface Loosen but do not remove the two screws that fasten the floppy disk drive to the module wall Slowly lift the floppy drive up and away from the module wall Disconnect the power
100. on of more SIMMs SVGA Super Video Graphics Array The video graphics standard that supports 800X600 graphic resolution and 1024X768 to 1280X960 text resolution displaying up to 256 colors Tone dial telephone A push button telephone that emits DTMF tones Norstar Applications Module II NAM Il Installation and Maintenance Manual Index A ACCESS Server 12 ACCESS Server admin 113 122 124 128 133 Alarms 129 Allocating Voice channels 117 Application administration 115 Backing up the capabilities file 121 Changing the ACCESS password 120 Connecting a laptop computer 108 Connecting a printer 110 Connecting an RS 232 terminal 108 From a telephone set 127 Installing an application 119 Installing applications 132 Laptop 108 Printer options 127 Rebooting the NAM Il 135 Remote connection 110 Removing an application 119 Restoring the capabilities file 121 RS 232 terminal 108 Scheduled reboot 136 Shutting down the NAM 121 Shutting down the NAM Il 134 Using the NAM II monitor 110 Using with terminal 113 Voice Channel sharing 130 Voice Channels 130 Administration software ACESS Server 127 Alarms 129 Viewing log 129 Application administration 115 Applications installing 132 ATA connecting to the internal modem 78 B B1 and B2 5 Back up capabilities file 67 Backing up 121 Capabilities file 121 Backup and restore 121 Capabilities file 121 Battery Installing 37 Installation and Maintenance M anual Removing 35 Cc
101. option also allows the user to issue a different reboot option if an application does not register with ACCESS 4 A confirmation screen appears 5 Press Y if you want to proceed with the System Reboot A confirmation screen appears telling you the system is rebooting Installation and Maintenance M anual Norstar Applications Module Il NAM II 124 Using the ACCESS Server administration software from a terminal Server Diagnostics Server Diagnostics provide you with diagnostic and statistical information about the NAM II Before you can access the Server Diagnostics option the ACCESS Server Menu must appear on your monitor For more information about accessing the Server Administration software refer to Using the ACCESS Server administration software from a terminal on page 113 To view diagnostic information 1 Press to select Server Diagnostics and then press Reurn The screen shows Server Diagnostics Voice Channels lt n gt Fax Channels lt n gt Number of printers 1 Color monitor Floppy drives 1 Enter Q to Quit 2 Press Q and then press Reum to return to the ACCESS Server Main Menu Norstar Applications Module II NAM Il Installation and Maintenance Manual Using the ACCESS Server administration software from a terminal 125 System password control This option allows you to customize the NAM II system password Before you can access the System Password Control option the ACCESS Serve
102. ortsignal Parallel device number name signal name 1 Strobe Ready 2 DO IDX 3 D1 TRKO 4 D2 WP 5 D3 RD 13t 6 D4 DCHG 7 D5 No connect bd CHD 8 D6 No connect 25 to 14 9 D7 No connect 10 ACK EXFDDR 11 Busy EXFMTR 12 PE WD 13 SLCT WG 14 AUTO FD DEN 15 ERRO R HS 16 IN IT DIR 17 SLCTIN Step 18 23 Ground Ground 24 Sense Sense 25 Ground Ground Keyboard and mouse A keyboard and mouse are attached to the NAM II using two six pin connectors located at the bottom of the module Figure 6 Mouse and keyboard connector pin out diagram and table Pin number Signal name Shell I Data 6 5 2 No connect 4 3 3 Signal ground 4 5V DC 24 5 Clock 6 No connect Shell Frame ground Norstar Applications Module Il NAM Il Installation and Maintenance Manual Components of the NAM Il 11 Optional equipment Additional equipment can be added to the NAM II to enhance its functionality Additions can include a e Modem e Monitor package e Printer e Network Adapter Card Modem A modem can be attached to Serial Port A COM1 The modem is necessary if you intend to perform Administration and Maintenance from a remote location Monitor package The monitor package includes a monitor SVGA card keyboard and a mouse This package is useful for on site programming and maintenance Printer A printer can be attached to the parallel port This printer is used for printing reports and alarms Nortel
103. ou can enhance functionality by adding more Voice Channels Refer to NAM II Hardware Upgrades and Replacements on page 25 for more information about upgrading your NAM II Hardware components of the NAM II Table 1 shows the hardware components that make up the NAM II Table 1 Hardware component summary Component Description Digital Voice Cards One or two cards each with two station ports and up to four Voice Channels Floppy drive 3 5 in 1 44 MB Hard disk drive One 3 5 in half height IDE 1 2 G B Internal modem One 14400 or 28800 bps modem for maintenance of the NAM Il Single Board Computer SBC Intel Pentium 100 MHz Floppy disk controller Enhanced IDE Hard disk controller PC Expansion Bus slots 4 full size ISA compliant slots one half length ISA compliant slot one half length PCI compliant slot one full size PCI ISA compliant slot and one Single Board Computer SBC slot Ports Two RS 232 serial one parallel one keyboard one mouse Power supply 200W 115 230 V switchable 50 60 Hz Memory 8 or 16 MB 60 ns EDO Parity expandable to 32 MB RAM Cables Hard disk drive floppy drive two serial ports keyboard mouse port parallel port reset and speaker Mechanical enclosure Metal chassis plastics and optional floor mount stand 1 2 GB is the minimum hard disk drive size Norstar Applications Module Il NAM II Installation and Maintena
104. ows Install De install an application 1 Install 2 Deinstall Q Quit Enter Selection Number 2 Press the number of the function you want 3 Press Q and then press Reum to return to the ACCESS Server Administration Menu Installation and Maintenance M anual Norstar Applications Module Il NAM II 120 Using the ACCESS Server administration software from a terminal Changing the ACCESS Server Password Access to the Server software is restricted The default password is ACCESS2 2223772 You can change this password using the Server Password Control option Before you can access the Server Password Control option the ACCESS Server Administration Menu must appear on your monitor For more information about accessing the Server Administration software refer to Administering an application on page 115 To access the Server Password Control option 1 Press to select Server Password Control and then press Reurn The screen shows Server Password Modification Enter QUIT to Quit Enter the New ACCESS Password 2 Enter the New ACCESS password and then press Reurn 3 Enter the password again and then press Reurm Norstar Applications Module II NAM Il Installation and Maintenance Manual Using the ACCESS Server administration software from a terminal 121 Backing up and restoring the capabilities file The Server Administration Backup and Restore option allows you to back up the NAM II capabilitie
105. pit 123456789 Keyboard mouse Connector Norstar Applications Module Il NAM II Clock calendar battery Serial Port A Connector Serial Port B Connector VE Installation and Maintenance Manual Adding and replacing memory 81 WARNING The microprocessor heat sink may be hot Pay careful attention not to touch the heat sink while removing or installing the SBC 8 Use both hands to carefully hold the SBC along the top Lift the SBC straight up and out from the module Sometimes the SBC is tightly seated and hard to remove You may need to wiggle it out with a slight rocking motion 9 Place the SBC on a flat surface with the SIMM slots facing up Refer to Figure 44 Caution A Failure to place the SBC on a flat surface may result in serious damage to the SBC W hile the SBC is out of the NAM II be careful not to slide or catch the back of the SBC this may cause the modules to become damaged 10 Slide the SIMM at 60 degree angle edge connectors first into the slot Refer to Figure 44 Note The SIMM cannot be inserted upside down The SIMM has a notch which lines up with a post on the SIMM slot on the SBC Do not force the SIMM into its slot Installation and Maintenance M anual Norstar Applications Module Il NAM II 82 Adding and replacing memory Figure 44 Installing a SIMM on the SBC 11 12 13 14 15 16 17
106. ps 10 to 18 Press MI N to change the minimum number of Voice Channels dedicated to the application Note To change the maximum number of Voice Channels dedicated to the application proceed to step 13 Press NC to increase the minimum number of Voice Channels dedicated to the application Continue pressing NC until you reach the desired number of Voice Channels Press DEC to decrease the minimum number of Voice Channels dedicated to the application Continue pressing DEC until you reach the desired number of Voice Channels Press 0K when you have reached the desired number of Voice Channels To change the maximum number of Voice Channels used by the application press SHOW Press SHOW Press MAX to change the maximum number of Voice Channels dedicated and shared allocated to the application Norstar Applications Module Il NAM II 132 Using the ACCESS Server administration software from a telephone set E orts p X 16 Press NC to increase the maximum number of DEC INC OK Voice Channels allocated to the application Continue pressing NC until you reach the desired number of Voice Channels Press DEC to decrease the maximum number of Voice Channels allocated to the application Continue pressing DEC until you reach the desired number of Voice Channels He ort I p DEC IN gt lt 17 Press OK when you have reached the desired OK number of Voice Channels am 18 Pres
107. r Menu must appear on your monitor For more information about accessing the Server Administration software refer to Using the ACCESS Server administration software from a terminal on page 113 To change the System password 1 Press to select System Password Control and then press Reurn The screen shows System Password Control Enter QUIT to Quit Enter the current Login Password 2 Enter the current password 3 Press Reurn 4 Enter the new password 5 Press Reurn 6 Enter the new password again 7 Press Reurn A confirmation screen appears 8 Press Q and then press Reurn to return to the ACCESS Server Menu Installation and Maintenance M anual Norstar Applications Module Il NAM II 126 Using the ACCESS Server administration software from a terminal Norstar Applications Module II NAM Il Installation and Maintenance Manual Using the ACCESS Server administration 17 software from a telephone set Overview This chapter provides information on accessing the Access Server from a telephone set For information on accessing the ACCESS server from a terminal refer to Using the ACCESS Server administration software from a terminal on page 113 Changing the printer options The Print Queue Manager allows you to hold cancel or resume all print jobs in the queue To change the printer options 1 Press Feature 9 1 5 d 2 Enter the default password k kjJe
108. rface 4 Open the module door The door may be locked To unlock the door use a screwdriver to turn the lock in the bottom right corner of the door Turn the lock 90 counterclockwise until the screwdriver slot is vertical 5 Remove the two screws holding the front cover to the module The screws are located along the top of the front cover 6 Slide the front cover out from the module Figure 14 Removing the front cover CA tt NL NIA HLL Installation and Maintenance M anual Norstar Applications Module Il NAM II 32 Preparing for the upgrade To replace the front cover 1 2 Insert the tongues on the bottom of the front cover into the module slots Fasten the two screws holding the front cover to the module Close the module door To lock the door turn the lock 90 clockwise until the screwdriver slot is horizontal Plug the power cord into the AC outlet Opening the cable trough The cable trough provides access to the external module connections You must open the cable trough when you want to access the NAM II serial ports parallel port and the mouse and keyboard ports To open the cable trough door grasp the slot in the upper right corner of the door and pull down The door will swing down To close the front cable trough door swing the door up until the two tongues on the door fit snugly into the module Removing the plastic case Before you remove the p
109. ring to use the ACCESS Server administration software e ACCESS Server administration software from a terminal e ACCESS Server administration software from a telephone set Installation and Maintenance M anual Norstar Applications Module Il NAM II 106 ACCESS Server Administration Norstar Applications Module II NAM Il Installation and Maintenance Manual Preparing to use the ACCESS Server 15 administration software Overview The ACCESS Server software resides on the NAM II The ACCESS Server administration software is designed to communicate with the Norstar system and provide support for applications running on the NAM II The ACCESS Server provides services to a group of devices including e routing of all voice commands between applications and DVCs e provision of special features such as supporting application installation and shutting down the system e management of all shared resources of the platform such as Voice and Fax Channels that are not managed directly by the operating system You can use this software from any two line display Norstar telephone connected to your voice mail system or by connecting an RS 232 terminal or laptop computer to the NAM II This section first describes what functions are available using a terminal to access the ACCESS Server Administration software and then describes the functions available using a Norstar telephone to access the Server Administration software Table 11 shows what func
110. rive 10 Plug in the NAM II and wait for the system to boot from the disk This process can take up to five minutes While the NAM II is booting you may hear a series of beeps After the AUTO CONFIGURATION DISK has finished loading you will hear a series of musical tones Installation and Maintenance M anual Norstar Applications Module Il NAM II 74 Installing and upgrading the hard disk drive 11 After all disk activity has ceased and the light on the floppy drive goes out unplug the AC power to the NAM II while the musical tones are still playing Remove the AUTO CONFIGURATION DISK from the floppy disk drive 12 Plug in the module Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing a new Internal modem 10 Overview The internal modem is removed when a failure is suspected or confirmed The internal modem is used for maintenance of the NAM II only It cannot be accessed by users Removing the internal modem To remove the internal modem 1 2 Shutdown the module Refer to Shutting down the NAM II on page 29 Remove the NAM II power cord from the AC outlet Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface Remove the front cover Refer to Removing the front cover on page 31 for more information on accessing the module Disconnect the Serial Port A and Serial Port B connectors from the SBC Disconnect th
111. rmation 12 Locate the correct expansion slot Refer to Table 3 for more information about the different card slots Remove the slot cover screw and the metal slot cover 13 Carefully hold the DVC along the top Insert the card by aligning it between the metal groove on one side and the slot opening on the other side 14 Push the DVC straight back and down until it fits snugly in place Ensure the edge connector is firmly inserted into the socket Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing and upgrading the Digital Voice Cards DVC s 55 Figure 32 Inserting the DVC 15 Fasten the slot cover screw in the DVC slot cover 16 Replace the front cover 17 Plug the power cord into the AC outlet Connecting a DVC to the distribution block Once the DVC is installed you must connect it to the distribution block To connect the DVC 1 Open the cable trough door For more information refer to Accessing the inside of the NAM II on page 30 2 Connect the teladapt cord to the DVC port Note If you are connecting a two board DVC you must connect the RFI filter to the DVC port and then connect the teladapt cord to the RFI filter 3 Connect the teladapt cord from the DVC port number 1 to the distribution block Refer to Figure 33 4 Close the cable trough door Installation and Maintenance M anual Norstar Applications Mod
112. rocessor clock calendar battery and four Single In Line Memory Modules SIMM slots are located on the SBC The SBC is removed when a failure is suspected or confirmed Figure 52 Components of the SBC Microprocessor Reset and speaker two brown Connectors Mer cable Connectors SBC dip switches p 4 ni S09oo0009 723456789 Clock calendar battery Serial Port A Connector Serial Port B Connector Port 80 LEDs Keyboard mouse Connector AS Installation and Maintenance Manual Norstar Applications Module Il NAM II 102 Installing and replacing the Single Board Computer SBC Removing and replacing the SBC To remove and replace the SBC 1 10 11 Shutdown the NAM II For more information refer to Shutting down the NAM II on page 29 Remove the NAM II power cord from the AC outlet Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface Remove the NAM II front cover Refer to Accessing the inside of the NAM II on page 30 Locate slot 4 and remove its slot cover screw and metal slot cover Disconnect the Serial Port A and Serial Port B connectors from the SBC Disconnect the keyboard mouse connector from the SBC Refer to Figure 43 on page 80 Disconnect the reset and speaker two brown connectors from the side of the SBC Disconnect the three ribbon cable conn
113. s expansion bus slot 4 Disconnect the Teladapt cord from a DVC Channel 5 Plug the free cord end into a Norstar telephone Press 0 to determine the Channel number connected to Norstar Voice Mail If the cord and Norstar Channel are working properly a number should appear Write down the Channel number and the corresponding Teladapt jack number 6 Reconnect the Teladapt cord to the module 7 Repeat this procedure beginning at step 4 for each DVC Channel 8 Ifa teladapt jack is not working check for loose connections or broken wires Ensure the problem is not with the teladapt cord Using a cord you know works connect the telephone and the jack to the KSU If neither the wiring nor the cord is the problem the KSU needs repair If the teladapt jacks are working you must identify which of the DVC Channels are not working Continuing from step 7 9 Plug in the NAM II and give it time to complete the diagnostics 10 Establish a Norstar Maintenance session From a Norstar telephone connected to the KSU access D Maintenance and 2 Port DN Status Refer to the Norstar Installation Guide for instructions 11 Display the type and state of the Channel connected to each of the Norstar teladapt jacks Verify the Channel numbers with the ones you wrote down when you tested the jacks in step 5 Installation and Maintenance M anual Norstar Applications Module Il NAM II 142 Troubleshooting Each Channel should show PC
114. s file SEKUR This file keeps a record of the upgrades and capabilities of your NAM II system It is important to back up this file when you increase the number of Voice Channels Note Before you begin ensure you have a blank high density formatted 1 44 MB 3 5 floppy disk Label the disk SEKUR Capabilities File To access the Backup Restore option 1 Press to select Backup Restore and then press Reurn The screen shows Backup Restore Insert the floppy diskette in the drive and select the option 1 Backup 2 Restore Q Quit Enter Selection Number 2 Press if you want to perform a backup and if you are restoring this file 3 Press Q and then press Reurn to return to the ACCESS Server Administration Menu Shutting down the NAM Il This option allows the installer to gently shutdown the NAM II OS 2 Warp requires a controlled shutdown to guarantee the integrity of the file system The Shutdown screen provides you with three options Graceful Quick and Immediate The Graceful option allows an application to terminate all existing calls before shutting down The Quick option allows only 45 seconds for an application to terminate before shutdown and the Immediate option allows only 15 seconds When you are shutting down NAM II you will usually use the Graceful option However if the system is not responding to the command you can speed up the process by changing the option to a Quick shutdown After 45 s
115. s to end this session Installing applications The Install applications option allows you to install other software packages that work in conjunction with the applications already running on the NAM II To install an application 1 Press Feature 9 1 5 Password 2 Enter the default password 2 2 J 2 3 7 7 J 2 LITITITISIPRETRY_ ACCESS2 ACCESS Server 3 Press ADMIN A J Prtjqueuejmgr 4 Press NEXT until the display shows QUI TI NEST SHOW H JAppl Install 5 Press SHOW QUIT NEXT SHOW Insert floppy 6 Press I NSTL QUITS Sf ff INSTL Norstar Applications Module II NAM Il Installation and Maintenance Manual Using the ACCESS Server administration software from a telephone set 133 Viewing the NAM II serial number The serial number option allows you to view the serial number of the unit This number is useful for verification and purchasing software options To view the serial number Pass d TISITITITT RETRY Ser BACKI NEXT ver ADMIH A fPrtfque i uef mgr HEXT SHOW J Number SHOW Nn af gt lt XXXXX POSEN XXX OK Press Feature 9 1 5 ri Installation and Maintenance Manual Enter the default password 2 2 J 2 J 3J7J7J 2 ACCESS2
116. stallation and Maintenance M anual Norstar Applications Module Il NAM II 4 NAM Il Components Norstar Applications Module II NAM Il Installation and Maintenance Manual Components of the NAM Il 2 The NAM II consists of e Intel Pentium 100 MHz microprocessor e 8or 16 MB of EDO RAM e 3 5 in 1 44 MB floppy disk drive e 3 5 in 1 2 GB IDE hard disk drive e Internal modem e OS 2 Warp operating system e Norstar ACCESS Server software 1 2 GB is the minimum hard disk drive size The NAM II can be connected to the Norstar KSU through one or more station ports on the Digital Voice Card DVC The DVCs provide the Time Compression Multiplexing TCM communication used by all Norstar telephones Each port on the DVC has a teladapt connector that supports two simultaneous voice conversations known as Voice Channels through a single teladapt cable These two Voice Channels are referred to as B1 and B2 Channels Figure 1 shows the interior functionality of the NAM II Figure 1 Functional diagram of the NAM II Serial port A Serial port B Parallel port Keyboard port Mouse port HTa disk Single Board B1 ae Computer SBC Tem a Floppy disk Digital Control channel D drive Voice B1 Control channel D Installation and Maintenance M anual Norstar Applications Module Il NAM II 6 Components of the NAM Il NAM Il upgrades The NAM II can be upgraded to host a variety of hardware and software configurations Y
117. taching one end of the grounding strap to your wrist and the other end to a grounded metal surface 6 Remove the front cover Refer to Removing the front cover on page 31 7 Unpack the DVC from the shipping container and antistatic bag Inspect for damage Handle the board by its edges at all times Do not touch any card components 8 Set the dip switch on SW1 Refer to Table 2 for information about the dip switch settings Table 2 Setting SW1 base offset address DVC DVC slot Switch positions 1 2 3 4 1 2 OFF OFF OFF OFF 2 5 OFF OFF ON OFF 3 6 OFF ON OFF OFF 4 7 OFF ON ON OFF ON is indicated by an arrow on the dip switch pointing away from the board 9 Ensure the jumper on JP1 is on position 11 Installation and Maintenance M anual Norstar Applications Module Il NAM II 54 Installing and upgrading the Digital Voice Cards DVC s 10 Position the jumper on JP7 according to the settings outlined in Table 3 Note No changes to factory default settings are required for the remaining switches and jumpers Table 3 Hardware interrupt levels and order of DVC installation Order of DVC installed DVC slot JP7 JP1 JP5 JP6 First DVC 1 2 On In 11 N A N A Second DVC 2 5 O ff In 11 N A N A Third DVC 3 6 O ff In 11 N A N A Fourth DVC 4 7 O ff In 11 N A N A 11 Determine which slot the DVC is to be installed in Refer to Table 3 for more info
118. te The Graceful option allows an application to terminate all existing calls before shutting down and restarting The Quick option only allows 45 seconds for an application to terminate before shutdown and the Immediate option only allows 15 seconds Norstar Applications Module Il NAM Il Installation and Maintenance Manual Using the ACCESS Server administration software from a terminal 123 When you are rebooting NAM II you will usually use the Graceful option However if the system is not responding to the command you can speed up the process by changing the option to a Quick Reboot After 45 seconds a Quick Reboot is performed Before you can access the Reboot System Menu option the ACCESS Server Menu must appear on your monitor For more information about accessing the Server Administration software refer to Using the ACCESS Server administration software from a terminal on page 113 To reboot the NAM II 1 Start from the ACCESS Server Main Menu 2 Press to select System Reboot and then press Reurn The screen shows The system reboot procedure will check that all the applica tions running on the server and registered with ACCESS are not running before rebooting the system Options 1 Graceful 2 Quick 3 Immediate Q Quit Enter the Reboot Option 3 Press the number of the Reboot option you want Note The Graceful option allows all applications time to complete operations and close all open files This
119. tenance Manual Installing the clock calendar battery 37 To install a new battery 1 Slide the battery at a 45 degree angle under the metal clip until the battery snaps into the socket Ensure the battery is completely seated in the socket The positive side of the battery faces upward WARNING There is a danger of explosion if the battery is incorrectly replaced You must replace the battery with a 3 V 170 mAh lithium coin cell battery 2 Replace any expansion bus cards that were removed 3 Replace the front cover 4 Close the module door To lock the door turn the lock 90 clockwise until the screwdriver slot is horizontal 5 Plug the power cord into the AC outlet Installation and Maintenance M anual Norstar Applications Module Il NAM II 38 Installing the clock calendar battery Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing the Digital Fax Card DFC 6 Overview A DFC can only be added to a NAM II that is equipped with software that supports fax functionality The DFC is installed in Expansion Bus slot 8 of the NAM II A standard DFC supports two fax Channel but can support four Channels with the addition of a 2 Channel daughterboard There are no TCM connections to the DFC The DFC uses the Voice Channels on the DVCs to connect the Fax Channels to fax machines or callers Note When Norstar Voice Mail FAX is using a Voice Channel to connect to the fax mach
120. the shutdown The NAM II issues a series of tones descending in pitch when the shutdown is complete Wait for the tones before you unplug the NAM II Norstar Applications Module II NAM Il Installation and Maintenance Manual Using the ACCESS Server administration software from a telephone set 135 Rebooting the NAM Il This option allows the installer to reboot the system The Reboot option ensures all applications are terminated before a reboot is performed Four reboot options are available Graceful Quick Immediate and Scheduled The Graceful option allows an application to terminate all existing calls before shutting down and restarting The Quick option only allows 45 seconds for an application to terminate before the reboot and the Immediate option allows 15 seconds For information on setting up a scheduled reboot refer to Scheduling a reboot of the NAM IF on page 136 When you are rebooting NAM II you will usually use the Graceful option However if the system is not responding to the command you can speed up the process by changing the option to a Quick Reboot After 45 seconds a Quick Reboot is performed To reboot the NAM II 1 Press Feature 9 1 5 Password 2 Enter the default password 2 J 2_ 2_ 3 7J 7 l2 J LITITITITIPRETRY ACCESS2 ACCESS Server 3 Press NEXT until the display shows System reboot 4 Pr
121. tions the Server Administration software provides Table 11 Server Administration software functionality Terminal Server functions Telephone Set Server functions Administer the printer queue Administer the printer queue View or clear the alarm and message log Setting the DTMF digit duration length Allocate Voice Channels View or clear the alarm and message log Install or remove applications Install applications Shutdown or reboot the system Shutdown or reboot the system Change the server password Scheduling a reboot of the system Perform server diagnostics Display the BIOS serial number Change the system password Set up disk restrictions Backup or restore the capabilities file Backup or restore the capabilities file Channel Status refer to Checking the Channel Status on page 142 Installation and Maintenance M anual Norstar Applications Module Il NAM II 108 Preparing to use the ACCESS Server administration software Using an RS 232 terminal or laptop PC The RS 232 terminal is used to access the administration software This software provides menus where you can select different options that allow you to change configuration settings Some configuration tasks require a terminal Other configuration tasks can be performed using an M7310 or M7324 telephone Before you can use an RS 232 terminal it must have the same communication settings as the NAM II To determine the terminal commun
122. tus display Press CLR to reset the display to an idle status Once any new activity on the Channels begins the display will change to show the activity of the Channels Pressing CLR does not physically clear all activity from the Channels Norstar Applications Module Il NAM II 144 Troubleshooting 37 No DVC BACKI NEXT DSBL 8 Press R 7 Continue pressing NEXT to view the specific details about the remaining Channels The display 1 2235 2291 isan example of a display 1 is the number of the Channel 2235 is the DN assigned to the Channel The DN can be up to seven digits in length 2291 is the DN of the extension that is currently connected to the Channel This number can either be the line number being used or a DN The number can be up to seven digits in length If the display shows in the last three characters on the display the Channel is idle and not in use For example the display might show 11 2245 LA Note Specific details will only be available for Channels that are assigned an a orf in the Channel Status display in step 5 If the display shows x Not in sync this means that the Channel has not been connected to the KSU and there is no DN assigned to the Channel If the display shows x No DVC this means that there is no DVC installed to the corresponding Channel number Note The xX in the display will be the number of the Channel s to end this programming sessio
123. tware provides the following services e routing of all telephony voice commands between applications and DVCs e provision of special features such as system shutdown e management of shared resources such as Voice Ports NAM II uses the multi tasking IBM OS 2 Warp operating system version 3 0 or greater OS 2 Warp and ACCESS are factory installed on the NAM II s hard disk drive Norstar Applications Module II NAM Il Installation and Maintenance Manual Section Il Installing the NAM II e Mounting the NAM Il on the wall e Mounting the NAM Ilona floor mount stand e Connecting to the NAM II to the KSU Installation and Maintenance M anual Norstar Applications Module Il NAM II 14 Installing the NAM II Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing the NAM Il 3 Introduction This section is intended for the installer of the NAM II and describes how the system should be installed and prepared for operation Station ports versus Voice Channels The NAM II is connected to the Norstar KSU through station ports The station ports are located on the Digital Voice Cards DVCs within the module These DVCs allow the NAM II to communicate with the KSU using Time Compression Multiplexing TCM Time Compression Multiplexing is used by all Norstar telephones The DVCs inside the NAM II each have two station ports for connection to the KSU Each of these DVC station ports support two s
124. u can access the Print Queue Manager the ACCESS Server Administration Menu must appear on your monitor For more information about accessing the Server Administration software refer to Administering an application on page 115 To access the Print Queue Manager 1 Press to select Print Queue Manager and then press Reurn The screen shows the Application Administration Menu Print Queue Manager Hold a print job Resume printing a held job Cancel a print job Alter the priority of the jobs Hold all jobs from printing Resume printing of all the held jobs Cancel all the print jobs Q Quit Enter Selection Number 2 Press the number of the function you want 3 Press Q and then press Reum to return to the ACCESS Server Administration Menu Norstar Applications Module II NAM Il Installation and Maintenance Manual Using the ACCESS Server administration software from a terminal 117 Viewing the Alarm and Message Log The Alarm and Message Log keeps a record of all system alarms and messages This log holds up to 1000 alarms and messages Once the log is full the older alarms and messages are overwritten Priority one alarms are sent to the KSU Alarm set Before you can access the Alarm and Message Log the ACCESS Server Administration Main Menu must appear on your monitor For more information about accessing the Server Administration software refer to Administering an application on page
125. ule Il NAM II 56 Installing and upgrading the Digital Voice Cards DVC s Figure 33 Connecting the teladapt cord J A G a 7 0 On L_ I 5 Once the DVC is installed and connected to the distribution block the card s first two Voice Channels are enabled Installing the first DVC This procedure is only for the installation of the first DVC This DVC will be placed in slot 2 If you are installing any other DVCs refer to Installing the second third or fourth DVC on page 52 Before you begin to install a DVC make sure you have a teladapt cord and if necessary an upgrade password If you are installing a two board DVC you will require an RFI filter You must also make sure that you have an antistatic strap to ground yourself with Note Before you add functionality to the NAM II you must first perform a backup Refer to Backing up the NAM II capabilities file on page 67 To install the first DVC 1 Ensure there is a Norstar station port available at the distribution block and wired to the KSU For more information on connecting the KSU to the NAM II refer to Connecting to the KSU on page 22 For instructions on mounting teladapt jacks and connecting the teladapt jacks to the station ports refer to the Norstar Installation Guide 2 Ensure that Auto Set Relocation on the Norstar system is set to NO Refer to the Norstar Installation Guide that came with th
126. use 13 Plug the power cord into the AC outlet Installing the SVGA video card on the SBC This procedure is for installing an SVGA on a NAM II that has Norstar Voice Mail installed Before you begin the installation you must have a 1 8 in slot screwdriver To install the video card 1 Shutdown the module For more information refer to Shutting down the NAM II on page 29 Remove the NAM II power cord from the AC outlet Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface Remove the NAM II front cover Refer to Removing the front cover on page 31 Remove the SBC from the NAM II Refer to Removing and replacing the SBC on page 102 Place the SBC on a flat surface with the microprocessor heat sink facing up Refer to Figure 48 Installation and Maintenance M anual Norstar Applications Module Il NAM II 90 Adding and removing a monitor keyboard and mouse Figure 48 SBC components Caution A Failure to place the SBC on a flat surface may result in serious damage to the SBC W hile the SBC is out of the NAM Il be careful not to slide or catch the back of the SBC this may cause the modules to become damaged Bottom SS po00000 123456789 SBC dip switch Microprocessor heatsink 7 Remove the two screws holding the metal slot cover to the bottom end of the SBC Remo
127. ust be unplugged and removed from its wall mount To change the power supply setting 1 Shutdown the NAM II For more information refer to Shutting down the NAM II on page 29 Remove the NAM II power cord from the AC outlet Remove the module from its wall mount Access to the voltage switch is through the top rear right hand corner of the unit Note If the module is on a floor mount stand you do not need to remove it from the stand Slide the slider switch mounted on the top of the power supply so that the desired voltage label is shown 115 or 230 Replace the module on its wall mount Plug the power cord into the AC outlet Norstar Applications Module II NAM Il Installation and Maintenance Manual Changing the power supply voltage 99 Figure 51 Changing the power supply voltage power supply switch I This unit is set at the factory to use 115 volts AC Failure to change the power supply voltage setting when using 230 volts AC will damage the unit beyond repair CAUTION Installation and Maintenance M anual Norstar Applications Module Il NAM II 100 Changing the power supply voltage Norstar Applications Module II NAM Il Installation and Maintenance Manual Installing and replacing the 14 Single Board Computer SBC Overview The Single Board Computer SBC is the main computing device of the NAM IL It runs the operating system and all applications installed on the NAM II The microp
128. ust back up the capabilities file SEKUR The SEKUR file contains all upgrade and capability information about your system including the number of voice channels and any upgrades to your system The SEKUR file must be restored if a hard disk failure occurs If this file is lost and your hard disk drive fails all upgrades made to your system will be lost Note Before you begin ensure you have a blank high density formatted 1 44 MB 3 5 floppy disk Label the disk SEKUR Capabilities File To back up the NAM II capabilities file 1 Press Feature fo i jis Gai 2 Enter the ACCESS password ITITITS JIRETRY Note The default password is ACCESS2 2223772 Installation and Maintenance Manual Norstar Applications Module II NAM II 68 Installing and upgrading the hard disk drive Access Server 3 Press ADMIN BACKI NEXT f ADMIN K JPrtjqueuejmgr 4 Press NEXT until the display shows E Bckp Rstr QUIT HERTS SHOW J E Bc tr 5 Press SHOW 6 Press BCKP opy 7 Insert a formatted floppy disk and press OK 8 Wait until the backup completes 9 Press OK Once you have backed up the NAM II capabilities file make sure you store the floppy disks in a safe place Removing the hard disk drive CAUTION A Do not use an electric screwdriver near the hard disk drive Information on the disk could be lost Refer to Specia
129. ve the slot cover from the SBC 8 Unpack the video card from the shipping container and antistatic bag The video card will be equipped with two posts and the SBC is equipped with two posts for connection of the card Inspect for damage Handle the board by its edges at all times Do not touch any card components Make sure you have all six screws that came with the video card 9 Slide the video card into a position so the metal slot cover bracket fits under the bottom edge of the SBC Ensure the slot cover bracket lines up with slot cover screw holes on the SBC Refer to Figure 49 Norstar Applications Module Il NAM Il Installation and Maintenance Manual Adding and removing a monitor keyboard and mouse 91 Figure 49 Video card connection points Slot cover screw holes Female video card connectors iE INI Liin now aai monn pannaan co A fee REA p sis E h SSH es A A AANA NATTA ET T RHO EARE EAE ee UUN nananman Tt NOONAN H e DH e aaa 8000 kee oo go o nnonnannnnn LN LU LLa eLa ieee
Download Pdf Manuals
Related Search
Related Contents
Samsung Galaxy Tab 4 (10.1, LTE)‎ מדריך למשתמש aSSurer la PÉrennitÉ Des insTaLLaTions inDUsTRieLLes OMNI-408EU My Book® Live™ User Manual USER`S MANUAL - JW Davis & Company ScaMPI User`s guide manual de instruções do cadinho de solda modelo ts-1015 Sample Probe Module, SPM, User`s Manual Milwaukee 2472-21XC Use and Care Manual Copyright © All rights reserved.