1. BATTERY INSTALLATION WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the battery door 1 Disconnect the test leads from the meter 2 Open the battery door by lifting the rear stand and removing the two screws using a Phillips head screwdriver 3 Insert the battery into battery holder observing the correct polarity 4 Put the battery door back in place Secure with the two screws WARNING To avoid electric shock do not operate the meter until the battery door is in place and fastened securely NOTE If your meter does not work properly check the fuses and battery to make sure that they are still good and that they are properly inserted OPERATING INSTRUCTIONS 1 ALWAYS press the POWER switch to the OFF position when the meter is not in use 2 If 1 appears in the display during a measurement the value exceeds the range you have selected Change to a higher range NOTE On some low AC and DC voltage ranges with the test leads not connected to a device the display may show a random changing reading This is normal and is caused by the high input sensitivity The reading will stabilize and give a proper measurement when connected to a circuit DATA HOLD The Data Hold function allows the meter to freeze a measurement for later reference 1 Press the DATA HOLD button to freeze the reading on the indicator The indicator J will be appea
2. WARNING Risk of Electrocution The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets As a result the reading may show 0 volts when the outlet actually has voltage on it Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no voltage is present CAUTION Do not measure AC voltages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur that can damage the meter 1 Set the function switch to the highest V AC position 2 Insert the black test lead banana plug into the negative COM jack Insert red test lead banana plug into the positive V jack 3 Touch the black test probe tip to the negative side of the circuit Touch the red test probe tip to the positive side of the circuit 4 Read the voltage in the display Reset the function switch to successively lower V AC positions to obtain a higher resolution reading The display will indicate the proper decimal point and value 11 DC CURRENT MEASUREMENTS 1 Insert the black test lead banana plug into the negative COM jack 2 For current measurements up to 200mA DC set the function switch to the highest DC mA position and insert the red test lead banana plug into the mA jack 3 For current measurements up to 10A DC set the function switch to the 10A range and insert the red test lead banana plug
3. sjposition 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive V jack 3 Touch the test probe tips to the diode or semiconductor junction you wish to test Note the meter reading 4 Reverse the probe polarity by switching probe position Note this reading 5 The diode or junction can be evaluated as follows A If one reading shows a value and the other reading shows 1 the diode is good B If both readings show 1 the device is open C If both readings are very small or 0 the device is shorted NOTE The value indicated in the display during the diode check is the forward voltage CAPACITANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements Remove the batteries and unplug the line cords 1 Set the function switch to the highest CAP position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive CAP jack 3 Touch the test leads to the capacitor to be tested 4 Read the capacitance in the display and then set the function switch to the lowest CAP position that is greater than the actual or any anticipated capacitance The display will indicate the proper decimal point and value MAINTENANCE WARNING To avoid electric shock disconnect the test
4. leads from any source of voltage before removing the back cover or the battery or fuse doors WARNING To avoid electric shock do not operate your meter until the battery and fuse doors are in place and fastened securely This MultiMeter is designed to provide years of dependable service if the following care instructions are performed 1 KEEP THE METER DRY If it gets wet wipe it off 2 USE AND STORE THE METER IN NORMAL TEMPERATURES Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts 3 HANDLE THE METER GENTLY AND CAREFULLY Dropping it can damage the electronic parts or the case 4 KEEP THE METER CLEAN Wipe the case occasionally with a damp cloth DO NOT use chemicals cleaning solvents or detergents 5 USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE Remove old or weak batteries so they do not leak and damage the unit 6 IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME the batteries should be removed to prevent damage to the unit REPLACING THE BATTERY WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the battery door 1 When the battery become exhausted or drops below the operating voltage will appear in the LCD display The battery should be replaced 2 Follow instructions for installing the battery See the Battery Installation section of this manual 3 Dispose of the old ba
5. Owner s Manual Digital MultiMeter Model No 82339 CAUTION Read understand and e Safety follow Safety Rules and Operating Operation Instructions in this manual before using this product e Maintenance Espa ol Sears Roebuck and Co Hoffman Estates IL 60179 www craftsman com 061906 TABLE OF CONTENTS Warranty Safety Instructions Safety Symbols Control and Jacks Symbols and Annunciators Specifications Battery Installation Operating Instructions Data Hold Backlight Range Indicator Input Shutters DC Voltage Measurements AC Voltage Measurements DC Current Measurements AC Current Measurements Resistance Measurements Continuity Check Diode Test Capacitance Measurements Maintenance Replacing the Battery Replacing the Fuses Troubleshooting Service and Parts ONE YEAR FULL WARRANTY ONE YEAR FULL WARRANTY ON CRAFTSMAN MANUAL RANGING MULTIMETER If this CRAFTSMAN Manual Ranging MultiMeter fails to give complete satisfaction within one year from the date of purchase RETURN IT TO THE NEAREST SEARS STORE OR OTHER CRAFTSMAN OUTLET IN THE UNITED STATES and Sears will replace it free of charge If this CRAFTSMAN Manual Ranging MultiMeter is used for commercial or rental purposes this warranty applies for 90 days from the date of purchase This warranty gives you specific legal rights and you may also have other rights which vary from state to state Sears Roebuck and Co Dept 817WA Hof
6. accuracy of the analog to digital converter NOTE Accuracy is stated at 64 F to 82 F 18 C to 28 C and less than 75 RH ambient MultiMeter conditions Diode Test Test current of approximately 1mA open circuit voltage 2 8V DC typical Continuity Check Audible signal will sound if the resistance is less than approximately 702 open circuit voltage 2 8V DC typical Input Impedance 10MQ VDC and VAC Display 2000 count LCD Overrange indication 1 is displayed Polarity Automatic no indication for positive polarity Minus sign for negative polarity Measurement Rate 0 4 seconds nominal Low Battery Indication EA is displayed if battery voltage drops below operating voltage Battery Requires one 9V NEDA 1604 or 6F22 battery sold separately Fuses mA range 200mA 250V fast blow 10A range 10A 250V fast blow SPECIFICATIONS Operating Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 10 F to 122 F 10 C to 50 C Relative Humidity lt 70 operating Operating Altitude 2000 meters 7000ft maximum Operating Humidity Max 70 up to 87 F 31 C decreasing linearly to 50 at 122 F 50 C Weight 12 340z 350g Size 7 52 x 3 23 x 1 42 191mm x 82mm x 36mm Safety For indoor use and in accordance with Overvoltage Category II Pollution Degree 2 Category II includes local level appliance portable equipment etc with transient overvoltages less than Overvoltage Category Ill
7. ce the fuse or battery 7 NEVER operate the meter unless the back cover and the battery and fuse doors are in place and fastened securely SAFETY SYMBOLS MAX 1000V O This symbol adjacent to another symbol terminal or operating device indicates that the operator must refer to an explanation in the Operating Instructions to avoid personal injury or damage to the meter This WARNING symbol indicates a potentially hazardous situation which if not avoided could result in death or serious injury This CAUTION symbol indicates a potentially hazardous situation which if not avoided may result damage to the product This symbol advises the user that the terminal s so marked must not be connected to a circuit point at which the voltage with respect to earth ground exceeds in this case 1000 VAC or VDC This symbol adjacent to one or more terminals identifies them as being associated with ranges that may in normal use be subjected to particularly hazardous voltages For maximum safety the meter and its test leads should not be handled when these terminals are energized Double Insulation CONTROLS AND JACKS 2000 count Liquid Crystal Display Power switch Function Switch mA current input jack 10A current input jack Backlight pushbutton Data Hold pushbutton Voltage resistance and capacitance positive input jack 9 Common negative input jack SYMBOLS AND ANNUNCIATORS ONDARON DY Continuity E Lo
8. er resolution reading The display will indicate the proper decimal point and value ND ND 12 RESISTANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements Remove the batteries and unplug the line cords 1 Set the function switch to the highest Q position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive Q jack 3 Touch the test probe tips across the circuit or part under test It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 4 Read the resistance in the display and then set the function switch to the lowest Q position that is greater than the actual or any anticipated resistance The display will indicate the proper decimal point and value 1 Set the function switch to the position 2 Insert the black lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive Q jack 3 Touch the test probe tips to the circuit or wire you wish to check 4 Ifthe resistance is less than approximately 70 the audible signal will sound If the circuit is open the display will indicate 1 DIODE TEST WARNING To avoid electric shock do not test any diode that has voltage on it 1 Set the function switch to
9. fman Estates IL 60179 For Customer Assistance Call 9am 5 PM EST Monday through Friday 1 888 326 1006 WARNING USE EXTREME CAUTION IN THE USE OF THIS DEVICE Improper use of this device can result in injury or death Follow all safeguards suggested in this manual in addition to the normal safety precautions used in working with electrical circuits DO NOT service this device if you are not qualified to do so SAFETY INSTRUCTIONS This meter has been designed for safe use but must be operated with caution The rules listed below must be carefully followed for safe operation 1 NEVER apply voltage or current to the meter that exceeds the specified maximum Input Limits Function Maximum Input V DC 200mV range 250V DC or AC V DC V AC 2200mV ranges 1000V DC or 700V AC mA DC AC 200mA DC AC 10A DC AC 10A DC AC Resistance Capacitance 250V DC AC Diode test Continuity 2 USE EXTREME CAUTION when working with high voltages 3 DO NOT measure voltage if the voltage on the COM input jack exceeds 1000V above earth ground 4 NEVER connect the meter leads across a voltage source while the function switch is in the current resistance or diode mode Doing so can damage the meter 5 ALWAYS discharge filter capacitors in power supplies and disconnect the power when making resistance or diode tests 6 ALWAYS turn off the power and disconnect the test leads before opening the doors to repla
10. into the 10A jack 4 Remove power from the circuit under test then open up the circuit at the point where you wish to measure current 5 Touch the black test probe tip to the negative side of the circuit Touch the red test probe tip to the positive side of the circuit Apply power to the circuit Read the current in the display For mA DC measurements reset the function switch to successively lower mA DC positions to obtain a higher resolution reading The display will indicate the proper decimal point and value AC CURRENT MEASUREMENTS WARNING To avoid electric shock do not measure AC current on any circuit whose voltage exceeds 250V AC 1 Insert the black test lead banana plug into the negative COM jack 2 For current measurements up to 200mA AC set the function switch to the highest AC mA position and insert the red test lead banana plug into the mA jack 3 For current measurements up to 10A AC set the function switch to the 10A range and insert the red test lead banana plug into the 10A jack 4 Remove power from the circuit under test then open up the circuit at the point where you wish to measure current 5 Touch the black test probe tip to the negative side of the circuit Touch the red test probe tip to the positive side of the circuit Apply power to the circuit Read the current in the display For mA AC measurements reset the function switch to successively lower mA AC positions to obtain a high
11. k Multitesters and Their Use for Electrical Testing Item No 82303 at your local Sears store 2 Call our Customer Service Line 1 888 326 1006 SERVICE AND PARTS Item Number Description 82375 Fuse kit 93894 9V Battery 82378 Set of black and red Test Leads 82339 DB Replacement battery door 82339 CS Rear cover screws For replacement parts shipped directly to your home Call 9 am 5 pm eastern M F 1 888 326 1006
12. r in the display 2 Press the DATA HOLD button to return to normal operation BACKLIGHT The backlight function illuminates the display to improve readability in dimly lighted areas _ 1 Press the E button to turn the backlight on 2 In order to conserve power the backlight will automatically turn off after 5 seconds RANGE INDICATOR The number below the decimal point in the LCD display indicates the full scale value of the range selected by the function switch INPUT SHUTTERS The yellow input shutters either block or open the input jacks to insure proper test lead connections for the measurement function selected 10 DC VOLTAGE MEASUREMENTS CAUTION Do not measure DC voltages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur fhat can damage the meter 1 Set the function switch to the highest V DC position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive V jack 3 Touch the black test probe tip to the negative side of the circuit Touch the red test probe tip to the positive side of the circuit 4 Read the voltage in the display Reset the function switch to successively lower V DC positions to obtain a higher resolution reading The display will indicate the proper decimal point and value If the polarity is reversed the display will show minus before the value AC VOLTAGE MEASUREMENTS
13. ttery properly 15 WARNING To avoid electric shock do not operate your meter until the battery door is in place and fastened securely REPLACING THE FUSES WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the fuse door 1 Disconnect the test leads from the meter and any item under test 2 Remove the protective holster and then remove the three screws and lift off the back cover 3 Remove the old fuse from its holder by gently pulling it out 4 Install the new fuse into the holder 5 Always use a fuse of the proper size and value 6 Replace the rear cover and secure it with the three screws WARNING To avoid electric shock do not operate your meter until the fuse door is in place and fastened securely UL LISTED The UL mark does not indicate that this product has been evaluated for the accuracy of its readings TROUBLESHOOTING There may be times when your meter does not operate properly Here are some common problems that you may have and some easy solutions to them Meter Does Not Operate 1 Always read all the instructions in this manual before use 2 Check to be sure the battery is properly installed 3 Check to be sure the battery is good 4 If the battery is good and the meter still does not operate check to be sure that both ends of the fuse are properly installed If You Do Not Understand How the Meter Works 1 Purchase the instructional boo
14. w Battery gt Diode Data Hold AC Alternating Current or Voltage DC Direct Current or Voltage mV V millivolt volt voltage Q KQ MQ ohm kilohm megohm resistance mA A milliamp Amp current nF uF nanofarads microfarads capacitance SPECIFICATIONS Function Range Resolution Accuracy DC Voltage 200mV 0 1mV 0 5 reading 1 digit V DC 2V 1mV 20V 10mV 0 5 reading 3 digits 200V 100mV 1000V 1V 0 8 reading 3 digits AC Voltage 200mV 0 1mV 1 2 reading 5 digit V AC 2V 1mV 50 60Hz 20V 10mV 1 0 reading 5 digits 200V 100mV 700V 1V 1 2 reading 5 digits DC Current 2mA 1uA p as ADC SODA TOUA 1 0 reading 3 digits 200mA 100uA 1 5 reading 5 digits 10A 10mA 2 0 reading 10 digits AC Current 2mA 1uA 1 2 reading 5 digits AAC 200mA 100uA 2 0 reading 5 digits SO 60Hz 10A 10mA 3 0 reading 10 digits Resistance 200Q 0 1Q 1 0 reading 10 digits 2kQ 1Q 20kQ 10Q E 200kO 1009 1 0 reading 1 digit 2MQ 1kQ 20MQ 10kQ 1 0 reading 5 digits 200MQ 100kQ 5 reading 10 20 digits Capacitance 2nF 1pF 20nF 10pF 200nF 0 1nF 4 0 reading 3 digits 2uF 1nF 20uF 10nF SPECIFICATIONS NOTE Accuracy specifications consist of two elements e reading This is the accuracy of the measurement circuit e digits This is the