Contents

1. Do not exceed the imprinted level mark corresponding to the maximum filling height when the unit is reassembled Then mount the support disk and the atomizer unit Caution Do not overfill the reservoir watch the maximum level mark as this may affect correct operation Caution Use only fresh tap water or partly fully demineralized water Caution When using additives make sure they do not affect health con sider long term effects too Buy certified products only Do not use additives based on essential oils because the may cause damage to the plastic parts of the humidifier Setting the unit into operation e Check the unit for possible damage Caution If the unit is damaged do not set it into operation Make sure the operating voltage of the Condair 505 see type plate on unit matches the local supply voltage then connect the unit to the mains The Condair 505 starts humidification without delay Operation In daily operation the water level and the humidity must be monitored on a regular basis For monitoring the humidity we recommend to use a hygrometer e g the Condair hygrometer placed in a suitable location not too close to the humidifier Disconnect the unit from the mains as soon as the desired level of humidity is obtained Please consider the following directional temperature and humidity values for optimal humidification Room temperature Humidity 18 C 55 rh 20 C 50 rh 22 C 45 rh Note For
2. In case of loss please contact your Condair representative for immediate replacement The Condair 505 is exclusively intended for direct room humidification under strict adherence to the information and notes given in this manual Any use beyond this scope is considered to be a violation of the intended purpose and may endanger your safety or possibly cause the productto be damaged Any use otherthan the intended purpose ofthe Condair 505 is at customer s own risk and for no means the manufacturer or supplier will be liable for possible damage The Condair 505 should be installed serviced maintained and repaired only by qualified persons familiar with the equipment The Condair 505 must not be used in hazardous locations Before connecting the unit to the mains make sure the operating voltage of the Condair 505 see type plate on unit meets the local mains voltage the power cord is not damaged The Condair 505 may be connected to a grounded socket only Do not disable protection using an extension cord without ground wire The ground wire must neither be disconnected nor interrupted inside or outside the unit as this may endanger your safety The Condair 505 operates at mains voltage Never dip the unit into water and protect it from splashes Before cleaning or maintaining the Condair 505 disconnect the unit from the mains pull the plug out of the socket Make sure your hands are absolut
3. semiautomatic Condair 505 and fully automatic operation Condair 505 S use the appropriate humidifier together with the humidistat H 4 The humidistat H 4 switches the humidifier on and off depending on the selected nominal humidity The humidistat H 4 is supplied with a separate installation manual Setting the unit out of service Disconnect the humidifier from the mains Empty the water reservoir then clean the unit following the instructions given in chapter 6 19 6 1 6 2 20 Maintenance and cleaning Cleaning intervals Regular checks and periodic maintenance are indispensable prerequisites for hygienic operation Regular checks Once a week you should carry out a regular check that includes the fol lowing steps cleaning of the water reservoir checking all components being in contact with water i e filter suction piece whirl disk guiding disk atomizer ring etc Periodic maintenance The maintenance interval depends on the operating conditions We rec ommend the following intervals high ratio of dust and or hard water 1 week medium ratio of dust and or normal water 1 2 weeks low ratio of dust and or demineralized water 2 4 weeks Note please refer to chapters 6 2 and 6 3 for detailed descriptions of the dismantling assembly and cleaning procedures required by particular com ponents Dismantling and assembly E A TTD AS Dismantling e Discon
4. Condair 505 Luftbefeuchter Air humidifier Humidificateur d air Umidificatore d aria gt BETRIEBSANLEITUNG OPERATING INSTRUCTIONS MODE D EMPLOI ISTRUZIONI PER PUSO N 1108693 DE EN FR IT 1112 l condair Unit survey 11 10 9 8 7 6 5 1 Reservoir 2 Filter 4 3 Stand 7 4 Support disk 5 Level detector assembly 6 Suction piece 3 7 Whirl disk 2 8 Guiding disk 9 Atomizer ring 10 Motor housing assembly 1 11 Aerosol discharge hood 12 Type plate 13 Mains cable with ground wire 2 1 2 2 Introduction Important notes Directed scope of use Safety instructions We thank you for having purchased the Condair 505 air humidifier The Condair 505 is a compact humidifier that is easy to operate and maintain A selection of optional accessories are available to customize the humidifier to your particular requirements The Condair 505 air humidifier is designed in accordance with the latest state of the art and the present safety regulations In the event of improper use however danger can arise for the user or third parties and or impairment of the unit or other material assets Carefully read these Operating Instructions prior to setting the humidifier into operation as they contain valuable informa tion on safe and economic use of your Condair 505 Please keep this manual in a safe place where it will be at hand whenever you need it
5. ely dry when pulling the mains plug out of the socket Never remove the plug by pulling the power cord Handle the power cord with care keep it away from sharp edges and do not jam or strain it Make sure nobody can trip over the cable fit can be assumed that safe operation is no longer possible the Condair 505 must be put out of service without delay Safe operation may be af fected in the following events the Condair 505 is damaged the Condair 505 does not operate correctly the power cord is damaged 15 3 2 16 Description of product Special version Functional description Except for the steps mentioned in this manual the user must not carry out further operations with the Condair 505 All components that are in contact with water must be thoroughly rinsed with tap water if the Condair 505 has not been in use for an extended period before filling the unit and after each deliming cycle Use only original accessories and genuine spare parts from your Condair supplier The Condair 505 may not be modified in any way without written consent from the manufacturer The special version Condair 505 S is designed for direct connection to the water supply The Condair 505 S is equipped with a float valve and a con nector for an overflow pipe Note The standard Condair 505 may be upgraded to the special version at any time please contact your Condair representative The C
6. nect the unit from the mains pull the plug out of the socket e Remove the atomizer unit and the support disk e Remove the aerosol discharge hood from the atomizer unit e Firmly hold the whirl disk while turning the suction piece anticlockwise until it comes off e Remove the whirl disk and the guiding disk e Carefully dismantle the segments of the atomizer ring Caution Cleaning and replacement of defective parts do not require further dismantling which is inadmissible and may void the warranty Assembly Proceed in the reverse order of the dismantling procedure to reassemble the unit 6 3 6 4 Cleaning Use lukewarm soapy water to clean the water reservoir support disk suction piece whirl disk guiding disk aerosol discharge hood and the segments of the atomizer ring Then thoroughly rinse all components with water If the components are heavily encrusted with lime soak them in 8 for mic acid until the lime layer is dissolved Finally clean the components as described above When cleaning make sure not to damage the outer edges of the whirl disk Defective disks reduce the efficiency of the humidifier and can cause damage to the bearing unbalance not to bend the lamellas of the atomizer ring Bent lamellas adversely affect the atomization process the inlet of the suction piece is open so that the water may pass through Use a cloth ora sponge moistened with soapy water to clean the mot
7. ondair 505 uses the atomizer principle The suction piece takes in the water from the reservoir Then the whirl disk moves the water towards the atomizer ring where it is transformed into aerosol fog The vanes of the whirl disk take in the air via the radial openings of the hous ing This air stream passes by the atomizer ring and directs the aerosol fog out of the humidifier in an upward direction The atomizer unit is driven by a maintenance free electric motor 3 3 Accessories and options The following accessories and options are available for the Condair 505 Directional cap vertical Z72 for vertical adjustment of the aerosol fog Directional cap horizontal Z73 for horizontal adjustment of the aerosol fog Deliming cap Z70 for lime free refill Water reservoir with float valve and safety overflow device for per manent water supply to the humidifier Humidistat H 4 for automatic control of the Condair 505 S 17 4 Location and installation 4 1 Notes on correct positioning Please observe the following notes for correct location of the Condair 505 Caution The Condair 505 must not be used in hazardous locations and areas that are exposed to water splashes Locate the Condair 505 in a way thatthe aerosol fog spreads freely Any obstacle hampering the spread of the aerosol fog causes turbulence and accumulation that may lead to condensation Please observe the foll
8. or hous ing Then rub the components with a wet cloth clean water several times If the components are heavily encrusted with lime rub them with a cloth soaked in an 8 formic acid solution Allow the acid to act for some time and then thoroughly clean the motor housing with water Caution Prevent the cleaning agent from getting into the electric motor Never clean the motor housing under the tap and never dip it in liquids of any kind Notes on cleaning agents Formic acid is available at pharmacies Caution Although formic acid is harmless to the skin it attacks the mu cous membranes Therefore protect the eyes and the respiratory tract from contact with the acid or its fumes Wear safety goggles and work in a well ventilated room or outdoors The use of disinfectants is allowed only when they leave no toxic residues In any case the components must be thoroughly rinsed with water after cleaning Caution Do not use solvents or other aggressive liquids for cleaning Do not use scouring equipment wire brush scouring cloth etc for cleaning because they leave scratches that encourage the growth of microorganisms Replacement of defective parts The customer must not carry out repairs other than the replacement of the following parts water reservoir support disk suction piece whirl disk guiding disk Please follow the instructions given in chapter 6 2 for the dismantling of partic
9. owing minimum clearance between the humidifier and nearby objects min clearance above the unit 1 50 m min clearance around the unit 0 30 m min clearance from cold outer walls and windows 1 00 m When using tap water or partially demineralized water the soluble mineral salts may precipitate Use fully demineralized water if non precipitating operation is required 4 2 Installation work Condair 505 S only Consult the following information for connecting the Condair 505 S to the water supply and the sewage line Water supply 1 Supply line min 4 6 mm copper tube Admissible water pressure 0 3 4 0 bar Admissible water temperature 1 40 C Water quality tap water partly orfullydemineralized water Overflow 2 Overflow line Din G 1 2 Min fall 5 Note It is mandatory to connect the overflow device to the sewage line 18 5 Operation Topping up Caution Disconnect the unit from the mains before topping up pull the plug out of the socket e Pour fresh water into the aerosol discharge hood or into the deliming cap accessory Z70 respectively Watch the level indicator water reservoir half full grey mark on level indicator is in view water reservoir full red mark on level indicator is in view If you wish to refill the Condair 505 directly from the tap remove the atomizer unit and the support disk from the reservoir Pour water into the reservoir
10. ppelschwimmer kpl Double float cpl Flotteur double cpl Galleggiante doppio cpl 22 0010 Doppelschwimmer kpl NL Double float cpl NL Flotteur double cpl NL Galleggiante doppio cpl NL 7 22 0293 Schalter kpl nur gr ne Version Switch cpl Commutateur cpl Interruttore cpl 47 Condair Ltd Printed in Switzerland Technische nderungen vorbehalten Technical modifications reserved Sous r serve de modifications techniques Con riserva di modifiche tecniche CONSULTING SALES AND SERVICE A Y SGS Reg No 40002 2 Manufacturer Condair Ltd Member of the Walter Meier Group Talstrasse 35 37 8808 Pf ffikon Switzerland Ph 41 55 416 61 11 Fax 41 55 416 62 62 info condair com www condair com
11. ular components 21 7 What if The following table presents malfunctions that might occur during humidifier ope ration explains their causes and suggests appropriate remedial action Malfunction Cause Remedy Humidifier is running but there is no aerosol fog No water in the reservoir Suction piece clogged Top up see chapter 5 Clean suction piece see chapter 6 Humidifier is not running although it is connected to the mains Excessive heat has triggered the thermal circuit breaker of the motor Motor defective Unit has been switched off by exter nal humidistat Let the motor cool down approxi mately 30 minutes then the unit will restart automatically Contact your local Condair repre sentative Check external humidistat and read just as required Overheated unit has cooled down restarts but stops again after a short while Water level in the reservoir exceeds the maximum level mark Unit heavily soiled Check water level Clean the unit see chapter 6 When running the humidifier emits a rumbling sound 22 Whirl disk mounted incorrectly Suction piece has come loose Mount whirl disk correctly Fix suction piece Please contact your Condair representative in case you cannot eliminate a particular source of trouble by yourself 8 Specifications Designation of unit Dimensions 9 x H Weight Mains connection Supply
12. voltage Humidification capacity Power consumption Acoustic capacity level Sound intensity level Drive Water reservoir Water quality Ambient temperature Ambient humidity Condair 505 360 x 230 mm 3 5 kg empty 6 5 kg ready for use via built in three core power cord 220 240 V 50 60 Hz or 100 110 V 50 60 Hz approx 500 g water hour suitable for locations up to 150 m3 40 W 50 dBA 44 dBA maintenance free electric motor with thermal circuit breaker made of polypropylene capacity 3 litres tap water partly or fully demineralized water 1 40 C 0 95 rh 23 Condair 505S 46 Pos Art Nr Ersatzteile Spare parts Pi ces de rechange Pezzi di ricambio 1 22 1491 Motor kpl 220 240V 50 60Hz Motor cpl Moteur cpl Motore cpl 22 1490 Motor kpl 100 110V 50 60Hz Motor cpl Moteur cpl Motore cpl 2 22 0006 Kondensator 1 uF 220 240V 50 60Hz Capacitor Condensateur Condensatore 22 0007 Kondensator 4 pF 100 110V 50Hz Capacitor Condensateur Condensatore 22 0008 Kondensator 3 uF 100 110V 60Hz Capacitor Condensateur Condensatore 3 22 0608 Zerst uberteil Atomizer assembly Atomiseur assy Nebulizzatore cpl 4 22 0585 Niveaueinheit Level unit Unit de niveau Unit di livello 5 22 0009 Ablaufanschluss Drain connection Raccord d coulement Collegamento di scarico 6 20 0471 Do