Home
EC type-examination certificate UK/0126/0136
Contents
1. When tare or preset tare values are printed they must be identified as such and net and or gross weights should be clearly identified when printed with a tare value Net weights do not require such identification when the tare value is not printed Printing below Min is not allowed 5 3 The instrument shall be fitted with a level indicator or be permanently installed 6 LOCATION OF SEALS AND VERIFICATION MARKS 6 1 The CE marking supplementary metrology marking and certificate number are located at the rear of the control cabinet Figures 3 and 4 The CE mark shall be impossible to remove without damaging it The data plate shall be impossible to remove without it being destroyed 6 2 The markings and inscriptions shall fulfil the requirements of Paragraph 9 of Annex of the Directive 2004 22 EC 6 3 Access to metrological settings is secured by a switch on the A D board Access to the switch and to the EPROMSs on the A D board is protected by a metallic cover secured by a tamper evident seal Figure 5 6 4 Access to the static calibration facility is password protected The instrument increments a calibration value audit count number each time it is re calibrated The value is recorded on a tamper evident label on the outside of the metal case protecting the A D board The current audit count number can be displayed via the About key in the Main Menu screen Details of the secure metrological parameters can be displayed via th
2. UPS backup type Pico UPS 100 Commel type LV 67H main board Devices The instrument is provided with the following devices 3 2 Initial zero setting device x 4 of Max Semi automatic zero setting device x 4 96 of Max Automatic zero setting after time interval s 15 min Zero tracking device Preset tare device oemi automatic tare device subtractive Zero indication Calibration not accessible to user Price computation PLUs TECHNICAL DATA The HI 700 TR has the following technical characteristics Maximum capacity Max lt 1500 g Scale interval e gt 19 Minimum capacity Min 2 50 g or 20 e whichever is higher Class Y 2 50 g Class X Tare T lt 50 Max Accuracy class Y a and XIII 1 Max operating rate Determined at initial verification Max conveyor speed lt 32 m min Load cell model HBM PW15 Load cell capacity 15 kg Power supply 220 250 Vac 50 60 Hz single phase Pneumatic pressure 4 6 bars Climatic environment 0 to 30 C Non condensing closed Electromagnetic environments E1 and E2 Documentation and drawings TA HI 700TR GA 1 0 HI 700 TR General arrangement IHI 07005 4 DSC ADC PCB assembly 000 026 14 Digi 700 name plate TA HI 700TR GA 8 0 Location of rating serial plate TA HI 700TR GA 2 0 and7 Sealing of A D assembly amp load cell in control box HI 700TRUM 04 700 User Manual Issue 1 HI 700TRSM 01 HI 700 Service Manual Issue 1 TA HI 700TR GA 9 0 HI 700TR Contro
3. National UK 0126 0136 Measurement Office EC type examination certificate UK 0126 0136 Issued by The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments Automatic Catchweighers Regulations 2006 51 2006 1257 and the Measuring Instruments Non Prescribed Instruments Regulations 2006 SI 2006 1270 which implement in the United Kingdom Council Directive 2004 22 EC this EC type examination certificate has been issued to Digi Europe Ltd Digi House Rookwood Way Haverhill Suffolk CB9 8DG United Kingdom in respect of an automatic catchweighing instrument designated the HI 700 TR and having the following characteristics Maximum capacity Max s 1500g Minimum capacity Min gt 509 interval e 21g Accuracy class Y a and XIII 1 The necessary data principal characteristics alterations securing functioning etc for identification purposes and conditions when applicable are set out in the descriptive annex to this certificate Issue Date 13 November 2012 Valid Until 12 November 2022 Reference No TS0101 0016 Signatory P R Dixon for Chief Executive BIS UKAS S National Measurement Office Stanton Avenue Teddington TW11 0JZ United Kingdom certirication Department for Business Tel 44 0 20 8943 7272 Fax 44 0 20 8943 7270 Web www bis gov uk nmo 0135 Innovation amp Skill
4. e Audit Query programme in the Windows operating screen 5 10 6 5 The load cell connection shall be secured as shown in Figure 6 7 ALTERNATIVES There are currently no authorised alternatives 8 ILLUSTRATIONS Figure 1 700 TR Figure 2 Operation touch screen display Figure 3 Rating plate location Figure 4 Rating plate Figure 5 A D board cover and sealing Figure 6 Load cell sealing 9 CERTIFICATE HISTORY DATE DESCRIPTION UK 0126 0136 13 November 2012 Type examination certificate first issued 6 10 1 HI 700 TR 7 10 Operation Screen Max 1 500kg 0 001 Min 0 050kg 0 750 Not Networked PLU No DEL TEST 09 11 2012 14 23 00000066 Help Exit Packs Per Minute lt Shop Name gt Min Weight 0 000 kg Dates Customer Name Max Weight 0 000 Running Totals 1 gt ___sing2 gt Pack Count 5 0 lt gt Weight kg 2 500 e e e Labeller Status Unit Price Pack Price Catch Weight Mode LabelFeed Automatic Mode Label Position Print Offset Void Pack View Totals start Lot Finish Lot Main Menu Figure 2 Operation touch screen display Figure 3 Rating plate location 8 10 HI 700 A D ASSEMBLY 568 717 SHOW SECURITY SECURI SWITCH SECURITY SWITCH FOR LEGAL METROLOGY A D board cover and sealing Load Cell Sea
5. l Box Layout 3 10 3 3 Software 3 3 1 The software version number is 2 xx xx xxxx which is displayed during the power up sequence of the instrument The legal metrological code is contained within a all file HI700 dll The dll file is protected by a checksum which is also displayed during the power up sequence Any modification in the dll file will result in a change in the checksum value and an error being detected Access to the Windows operating system is prevented by password protection 3 3 2 In addition to the weight and weight price labelling modes of operation the instrument is provided with non weighed items fixed price and fixed weight and average weight modes of operation The mode of operation is set in the products PLU only available at supervisor level 3 3 3 The parameters nominal weight and tolerance limits used by the average weight mode are calculated by the system and cannot be modified An average weight label contains the nominal weight with the associated units of measurement the symbol and a fixed price Any pack that falls outside of the average weight limits is not labelled i e rejected 4 PERIPHERAL DEVICES AND INTERFACES 4 1 Interfaces The instrument may have the following interfaces USB Ethernet 4 2 Peripheral devices The instrument may be connected to any peripheral device that has been issued with a test certificate or parts certificate by a Notified Body responsible for A
6. ling Two Uptions SEAL LABEL 450 074 Thin Wire Through Conector Release Clips Seoled wlth DIGI Seol TO LOAD CELL TO LOAD CELL Load Cell Cable Cell Cable Figure 6 Load cell sealing Crown Copyright 2012 NATIONAL MEASUREMENT OFFICE Department for Business Innovation amp Skills 10 10
7. nnex B MI 006 under Directive 2004 22 EC in any Member State and bears the CE marking of conformity to the relevant directives or A peripheral device without a test certificate may be connected under the following conditions it bears the CE marking for conformity to the EMC Directive it is not capable of transmitting any data or instruction into the weighing instrument other than to release a printout checking for correct data transmission or validation it prints weighing results and other data as received from the weighing instrument without any modification or further processing and it complies with the applicable requirements of Paragraph 8 1 of Annex I 4 10 5 APPROVAL CONDITIONS The certificate is issued subject to the following conditions 5 1 Legends and inscriptions The instrument bears the following legends CE marking Supplementary metrology marking Notified body identification number Accuracy class Serial number Type designation Manufacturers mark or name Certificate number Power supply Pneumatic pressure 5 2 Printing weigh weigh price labeller Editing of the weight and price data printed on to the sealing film is performed via the Digi label format software its access is restricted to Manager or Supervisor levels The labels must bear the weight unit price and price to pay when applicable with associated units Currency units must be in accordance with the country of use
8. ocells are used for pack detection 2 1 3 The control cabinet is mounted in the base of the frame below the scale conveyor and houses the electronics and electrical control elements of the instrument The control and display unit consists of a colour LCD touch screen Figure 2 and may be mounted on the main frame or remotely if clearly visible by the user 2 1 4 The weighing system comprises a scale conveyor mounted on a load cell Packs will be automatically transported on to and off the scale conveyor using a bespoke chain conveyor powered and driven independently of the instrument The operating speed of the conveyor is fixed by the manufacturer with a maximum speed of 32 m min 2 1 5 The weight and price data determined and calculated by the HI 700 TR is transmitted via the Ethernet connection to a remote thermal printer mounted inside the tray sealing machine The transaction data is printed on the top sealing films which are then used to seal the packs The Instrument may be configured for the chain conveyor to operate with either a left to right flow direction or a right to left flow direction Other transport systems may be used 2 1 6 Load cell The load cell is an HBM PW15 capacity as per section 3 1 2 10 2 2 Electrical The HI 700 TR weigher comprises the following 2 3 LCD display type TFT G150XG01 15 850CD M2 Digi Europe A D converter type DSP A D conversion PCB TDK Lambda power supply unit LS75 and
9. s MID Annex Rev 2 01 April 2011 Descriptive Annex 1 INTRODUCTION This pattern of an automatic catchweigher designated the HI 700 TH operates as an automatic weight or weight price labeller Category Y and as an automatic checkweigher category X The instrument comprises a self indicating and price computing weighing machine with associated mechanical handling facilities tray sealing and thermal label printer It is designed to weigh packs dynamically at a constant rate of operation Pricing pack and labelling information is stored in files called PLUs selectable by the operator for the commodity being processed The transaction data is automatically printed on the top sealing films which are then used to seal the packs The instrument provides indications of price per unit weight from 0 01 to 9999 99 per kg by 0 01 intervals price to pay from 0 01 to 9999 99 by 0 01 intervals rounded to the nearest 1p with 0 5p rounded up FUNCTIONAL DESCRIPTION 2 1 Mechanical 2 1 1 The 700 TR comprises weigher tray sealing system and thermal label printer Figure 1 The weigher is mounted on single fabricated floor standing stainless steel frame on adjustable stainless steel feet 2 1 2 On the frame are mounted the scale conveyor and any additional in feed and out feed conveyors any number may be used Various conveyor sizes may also be used In feed guides may be fitted which are adjustable Phot