Avery Weigh-Tronix Model E1010 Digital Indicator

image

Contents

1. Table 1 and Figure 1 which is of stainless steel housing construction and which may be configured to form part of A weighing instrument with a single weighing range of up to 10 000 verification scale intervals or A multi interval weighing instrument with up to two partial weighing ranges each with its own verification scale interval in which case it is approved for use with up to 5000 verification scale intervals per partial weighing range Instruments may be fitted with output sockets output interfacing capability for the connection of auxiliary and or peripheral devices Instruments are powered directly by mains AC power adaptor or by an internal rechargeable battery This approval does not include the use of the indicator as an automatic weighing instrument unless specifically mentioned in a certificate of approval for such an instrument TABLE 1 Specifications Maximum number of verification scale intervals 10 000 or 5000 per range Minimum sensitivity 0 5 uV scale interval Excitation voltage 5VDC Maximum excitation current 57 5 mA 1 1 Zero Zero is automatically corrected to within 0 25e whenever the instrument comes to rest within 0 5e of zero The instrument has a semi automatic zero setting device to set the instrument to within 0 25e of zero with a nominal range of not more than 4 of the maximum capacity of the instrument 1 2 Tare A semi automatic subtractive taring device of up to the maximum
2. capacity of the instrument may be fitted A pre set taring device keyboard entered and or stored of up to the maximum capacity or of up to the Max the maximum capacity of the lower interval range for multi interval instruments may also be fitted sil S457 23 June 2005 Technical Schedule No S457 Page 2 1 3 Display Check A display check is initiated whenever power is applied 1 4 Linearisation Facility Instruments are fitted with a programmable multi point linearisation correction facility 1 5 Additional Features The indicator may also have certain additional functions including setpoints cut offs and under accept over functions Some functions can be assigned to a function key of the indicator However this approval does not include the use of the indicator as an automatic weighing instrument unless specifically mentioned in a certificate of approval for such an instrument The additional functions other than the indications of measured mass i e gross tare net totals displayed either on the indicator or on an auxiliary or peripheral device are not approved for trade use 1 6 Markings and Notices Instruments carry the following markings Manufacturer s mark or name written in full Avery Weigh Tronix Ltd Name or mark of manufacturer s agent Indication of accuracy class Maximum capacity Max kg 1 Minimum capacity Min kg 1 Verification scale interval Sahn kg 1 Maxim
3. S457 14 January 2011 Ne ig RY x d Australian Government National Measurement Institute Bradfield Road West Lindfield NSW 2070 Notification of Change Supplementary Certificate of Approval No S457 Change No 1 Issued by the Chief Metrologist under Regulation 60 of the National Measurement Regulations 1999 The following changes are made to the approval documentation for the Avery Weigh Tronix Model E1010 Digital Indicator submitted by Avery Weigh Tronix Ltd Foundry Lane Smethwick West Midlands B66 2LP UK A In Supplementary Certificate of Approval No S457 dated 23 June 2005 1 The Condition of Approval referring to the review of the approval should be amended to read This approval becomes subject to review on 1 July 2015 and then every 5 years thereafter 2 The FILING ADVICE should be amended by adding the following Notification of Change No 1 dated 14 January 2011 Signed by a person authorised by the Chief Metrologist to exercise his powers under Regulation 60 of the National Measurement Regulations 1999 S457 23 June 2005 Australian Government National Measurement Institute 12 Lyonpark Road North Ryde NSW 2113 Supplementary Certificate of Approval No S457 Issued by the Chief Metrologist under Regulation 60 of the National Measurement Regulations 1999 This is to certify that an approval for use for trade has been granted in respect of the Avery Weigh Troni
4. configuration and calibration audit trail differ from those of the model E1010 and are as follows starting from the normal weighing mode enter the user mode by holding the Zero key for approximately 5 seconds Enter the user password 111 by the following set of keystrokes press Select twice Units Select twice Units Select twice and then press the F1 key Press the Units key to enter the Audit mode Press the Print key to enter the Configuration Counter display mode Press the Print key The value displayed for a short period is the configuration counter value CFG Press the Units key to enter the Calibration Counter display mode Press the Print key The value displayed for a short period is the calibration counter value CAL Press the Zero key to return to the normal weighing mode TEST PROCEDURE Instruments should be tested in accordance with any relevant tests specified in the Uniform Test Procedures Maximum Permissible Errors at Verification Certification For single range instruments the maximum permissible errors for increasing and decreasing loads on initial verification certification for loads m expressed in verification scale intervals e are 0 5e for loads 0 lt m lt 500 1 0e for loads 500 lt m lt 2 000 and 1 5e for loads 2 000 lt m lt 10 000 For multi interval instrum
5. e recorded on a destructible adhesive label attached to the instrument e g as CFG x CAL y Any subsequent alteration to the calibration or configuration will be evident as the recorded values and the current counter values will differ The current value can be displayed by using the following sequence starting from the normal weighing mode enter the user mode by holding the Esc key for approximately 5 seconds Enter the user password 111 and press the Enter key Press the Units key to enter the Audit mode Press the Print key to enter the Configuration Counter display mode Press the Print key The value displayed for a short period is the configuration counter value CFG Press the Units key to enter the Calibration Counter display mode e Press the Print key The value displayed for a short period is the calibration counter value CAL Press ESC twice to return to the normal weighing mode 2 Description of Variant 1 The Avery Weigh Tronix model E1005 Figure 2 which is similar to the pattern model E1010 and has the same specifications Table 1 but which has a plastic housing and a reduced set of functions and operator keys In particular the model E1005 does not have the capability for pre set tare keyboard entered or stored 4 S457 23 June 2005 Technical Schedule No S457 Page 4 2 1 Sealing The instructions for accessing the
6. ents with verification scale intervals of e e apply e for zero adjustment and maximum permissible errors apply e e as applicable for the load S457 23 June 2005 FIGURE S457 1 Avery Weigh Tronix Model E1010 Digital Indicator S457 23 June 2005 FIGURE S457 2 Avery Weigh Tronix Model E1005 Digital Indicator
7. reserves the right to examine any instrument or component of an instrument purporting to comply with this approval Auxiliary devices used with this instrument shall comply with the requirements of General Supplementary Certificate No S1 0 A The values of the performance criteria maximum number of scale intervals etc applicable to an instrument incorporating the pattern approved herein shall be within the limits specified herein and in any approval documentation for the other components DESCRIPTIVE ADVICE Pattern approved 17 June 2005 An Avery Weigh Tronix model E1010 digital mass indicator Variant approved 17 June 2005 1 An Avery Weigh Tronix model E1005 digital mass indicator Technical Schedule No S457 describes the pattern and variant 1 FILING ADVICE The documentation for this approval comprises Supplementary Certificate of Approval No S457 dated 23 June 2005 Technical Schedule No S457 dated 23 June 2005 incl Table 1 and Test Procedure Figures 1 and 2 dated 23 June 2005 Signed by a person authorised by the Chief Metrologist Sagl to exercise his powers under Regulation 60 of the gi at 4 y National Measurement Regulations 1999 di S457 23 June 2005 TECHNICAL SCHEDULE No S457 Pattern Avery Weigh Tronix Model E1010 Digital Indicator Submittor Avery Weigh Tronix Ltd Foundry Lane Smethwick West Midlands B66 2LP UK 1 Description of Pattern An Avery Weigh Tronix model E1010 digital mass indicator
8. um subtractive tare kg 2 Serial number of the instrument a eee Pattern approval mark for the indicator NMI S457 Pattern approval mark for other components _ 3 1 These markings are also shown near the display of the result if they are not already located there 2 This marking is required if Tis not equal to Max 3 May be located separately from the other markings In addition instruments not greater than 100 kg capacity shall carry a notice stating NOT TO BE USED FOR TRADING DIRECT WITH THE PUBLIC or similar wording Note For multi interval instruments the markings shall be as above with the exception that the Maximum capacity and Verification scale interval shall be marked for both interval ranges e g as follows Maximum capacity Max KO 1 Verification scale interval Zi Jausas kg 1 sal S457 23 June 2005 Technical Schedule No S457 Page 3 1 7 Verification Certification Provision Provision is made for the application of a verification certification mark 1 8 Sealing Provision Access to the configuration and calibration facility is password protected note that the passwords required to configure or calibrate the instrument are not the same as the user password shown in the instructions below The indicator increments a configuration and or calibration value audit trail number each time the indicator is re configured and or calibrated The value s of these counters may b
9. x Model E1010 Digital Indicator submitted by Avery Weigh Tronix Ltd Foundry Lane Smethwick West Midlands B6 62LP UK NOTE This Certificate relates to the suitability of the pattern of the instrument for use for trade only in respect of its metrological characteristics This Certificate does not constitute or imply any guarantee of compliance by the manufacturer or any other person with any requirements regarding safety CONDITIONS OF APPROVAL This approval becomes subject to review on 1 July 2010 and then every 5 years thereafter Instruments purporting to comply with this approval shall be marked with approval number NMI S457 and only by persons authorised by the submittor si S457 23 June 2005 Supplementary Certificate of Approval No S457 Page 2 Instruments incorporating a component purporting to comply with this approval shall be marked NMI S457 in addition to the approval number of the instrument It is the submittor s responsibility to ensure that all instruments marked with this approval number are constructed as described in the documentation lodged with the National Measurement Institute NMI and with the relevant Certificate of Approval and Technical Schedule Failure to comply with this Condition may attract penalties under Section 19B of the National Measurement Act and may result in cancellation or withdrawal of the approval in accordance with document NMI P 106 The National Measurement Institute